This Statement of Work (SOW) details specifications for a pump package accessory for a fire engine for the U.S. Fish and Wildlife Service's North Dakota Fire Zone/Upper Souris NWR, to be installed on a 2025 Ford F550 crew cab chassis located in Devils Lake, ND. The comprehensive requirements include a 300-gallon poly tank with 8-gallon foam reserve, a BB-04 pump, 23 horsepower motor, Hannay hose reel, stainless steel piping, water-tight storage boxes, emergency lighting (LED red/white), a front bumper/grill guard with a 20,000 lb winch, and a custom Ford F550 center console with multiple electrical and communication features.

The SOW specifies detailed color requirements (Oxford White and gloss black), with a 3-year paint warranty, and mandates a complete pumping test conforming to NFPA Standard 1906. The delivery timeline allows for immediate contract award, with the vendor expected to complete the build within 120 days. The technical point of contact is Jason Wagner, and the government will drop off and pick up the truck from the vendor's facility. The final apparatus must undergo a certified pumping test, with results provided to the U.S. Fish and Wildlife Service at the time of delivery.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

North Dakota Fire Zone/Upper Souris NWR

PUMP PACKAGE ACCESSORIES FOR FIRE ENGINE

11/17/2025

The U.S. Fish and Wildlife, North Dakota Fire Zone, 221 2nd St NW Suite 2 Devils Lake, ND 58301 has a request for Standard Model 52 pump package or equivalent, with brand name or equal accessories (Troy Products). The request is for 1 pump package to be placed on existing 2025 Ford F550 crew cab chassis. Vehicle is located in Devils Lake, ND.

REQUIREMENTS:

Standard Model 52 pump package Specifications

300 gallon model 52 to include: 300 gallon poly (lower-profile) tank with 8 gallon foam reserve, control panel, BB- 04 pump with drain valve, 23 horse power minimum 4 stroke motor, 1 Hannay polished aluminum hose reel mounted on rear with 2/3hp electric rewind motor and a steel box (painted) underneath for fittings and manual guzzler primer, Stainless steel piping with Y strainer, stainless steel gas tank 5 gallon minimum, hose rack, 2 steel boxes with water tight compartments (3 each) and zolatone coating, length of the flatbed with doors that have support cables, stainless steel flush mount slam-type D-Ring auto latching hinges, automatic on/off LED cabinet lights when door opens/closes. Powder coating or zolatone inside and adjustable shelves, deck, brass foot-valve, quick change hose fittings, Elkhart brass shut off valves, all valves should be labeled. Mounted dry box 42”Wx42”Lx18”H located on top of water tank. 9 foot 6 inch Flat bed with (3) Aluminum drafting hose containers with Blaylocks integrated into the bed. W ater tight tool box mounted underneath the flatbed in front of rear tires just behind the cab with drain plug. (2) wheel chocks mounted for easy access, Blizzard Wizard foam proportioning system, Hard Line hoses 150 foot on the reel. Install provided back-up camera to vehicle specifications, protected from impact and debris. One (1) solid state back up alarm installed at the rear of apparatus, protected from impact and debris. The back-up alarm shall be wired to the reverse circuit of the transmission and shall provide minimum volume of 87 decibels, maximum volume of 112 decibels, and automatically adjust to 5 decibels above ambient noise while in operation. Spare tire holder. Warning label/fluid data that informs operators of vehicle height, weight, and proper fluids and capacities, lighted water level gauge mounted in operator cab within sight of driver. Master switch located in cab that disables all power. Access step to be installed to easily gain access to top storage box.

Front Bumper/Grill Guard

Front bumper/grill guard combination to be purchased or built by contractor and installed on the engine.

• Must include winch rated at or above 20,000 lbs

• Contractor must install winch to be fully operational

Vehicle Emergency Lighting

LED 2 color (red/white) Emergency Lights (NFPA 1906 Standards) to provide 360 degrees visible range, PA system (code 3).

• Additional LED red flashing lights placed Powder coated heavy duty grille guard with minimum 12000# winch installed and mounted to vehicle.

o Grille guard should include 2 inch receiver tube and 2 integrated external tow eyes if manufacture supplied eyes are not accessible.

• Additional LED red flashing lights placed on back of truck either imbedded into flat bed or on top rack.

• Take Down and Alley Lights-controlled by internal switch

• LED flood lights installed for rear and side cab protection. Operation of lights should be through in-cab switches and/or pump control panel.

• Light bar shall be installed utilizing a non-permanent mounting system.

• 2 front and 2 rear LED work lights installed for 360 degree and controlled independently by internal uplifter switch.

Color:

• Slip on package including steel boxes, piping, etc shall be painted with an automotive acrylic urethane or polyurethane paint and Oxford White in Color.

• Metal parts including metal tool box mounted underneath the flatbed, flatbed, etc shall be painted gloss black acrylic automotive grade enamel.

• Items that are powder coated shall have a minimum 1-2 mm flat black powder coated finish.

All paint to be warrantied for 3 years post completion and customer pick-up of build.

Additional Requirements:

Troy Products Ford F550 center console to be purchased and installed by company to accommodate aux switches for lights, sirens, etc, house PA system, mobile radio, additional ac outlets, etc.

Specifications of product must include:

• The console shall have a minimum of four {4) additional 12 volt power sources, two with double USB plugs, with covers, for recharging cell phones, or other 2 similar battery operated devices.

• Electrical Switch Panel‐ A switch panel shall be installed to operate the accessory lighting and equipment installed on the vehicle.

• Agency Radio Mounting Panel ‐Two radio panel blank filler plates or 6” radio specific mounting plates shall be installed. Bendix King KNG mobile style.

• Cup Holders ‐ A minimum of two (4) cup holders shall be installed. Location of the cup holders shall be such that spilled liquid shall not interfere with electrical equipment. 2 for front passengers and 2 for rear.

• Map Light ‐A map light shall be installed to the passenger side of the console. The map light shall be a minimum of 12" in length, flexible, 12 provide uniform light output with near zero glare. The light source shall be two (2) 3W LEDs‐ one for red and one for white.

• Mounting Panel for PA Control Head‐ One mounting panel for PA control head shall be installed.

• Accessory Pocket‐One open section of the console shall be supplied to 17 allow storage of maps.

• Pre‐Wire for district Radio(s) as required by the unit. Including mounting of provided antenna and other wiring. Bendix King KNG Mobile radio capable.

Upon completion, the apparatus shall undergo a complete pumping test that conforms to the requirements of NFPA Standard 1906 (latest edition) for the size and type of pump provided. Test results shall be certified in writing and provided to US FWS at time of pickup/delivery.

The above package needs to be fire ready and mounted on the vehicle, when ready for pickup. Item will be installed at the vendors’ facility.

One pump package for North Dakota Fire Zone in Devils Lake, ND

DELIVERABLE OR DELIVERY SCHEDULE:

Government will drop off and pickup truck from vendor.

PLACE/DELIVERY AND PERIOD OF PERFORMANCE:

Period of Performance Delivery of Engine can be immediate upon contract award. Once received vender should complete build in 120 days.

INSPECTION AND ACCEPTANCE:

Technical point of contact is Jason Wagner, Phone #: (701)213-9579.

GOVERNMENT FURNISHED EQUIPMENT OR MATERIALS/INFORMATION:

Government will drop off and pickup truck from vendor.

TECHNICAL COORDINATOR:

Point of Contact for technical assistance is Jason Wagner, Phone #: (701)213-9579.

Standard Model 52 pump package Specifications
Front Bumper/Grill Guard
Vehicle Emergency Lighting
Color:
All paint to be warrantied for 3 years post completion and customer pick-up of build. Additional Requirements:
Specifications of product must include:
DELIVERABLE OR DELIVERY SCHEDULE:
PLACE/DELIVERY AND PERIOD OF PERFORMANCE:
INSPECTION AND ACCEPTANCE:
GOVERNMENT FURNISHED EQUIPMENT OR MATERIALS/INFORMATION:
TECHNICAL COORDINATOR: