A04_SOW_Attch_2_FORA_Mx_septic_details.pdf
PDF 1 MB Posted
- Attached to
- Cape Hatters NS Fort Raleigh: SEPTIC SYSTEM Federal contract opportunity
- Solicitation number
- 140P5324R0020
About this file
This document package includes technical specifications and drawings for replacing the septic system at Fort Raleigh Maintenance in Manteo, North Carolina. The scope of work calls for installing a 1,000 gallon concrete septic tank, PVC riser and lateral lines, cleanout assemblies, and an infiltration field using chambers that meet North Carolina standards. The contractor must use tank and product manufacturers approved by the North Carolina Department of Health and Human Services. Tank installation must be water tested and approved. This work supports Solicitation 140P5324R0020 issued by the National Park Service Southeast Region for the Cape Hatteras National Seashore Fort Raleigh site. The specifications provide requirements for materials, installation, and testing of the new septic system.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| A04_SOW__Replace_Septic_System_at_Ft_Raleigh_Maintenance.doc | DOC document | |
| B08_Relevant_Prior_Experience.pdf | ||
| Sol_140P5324R0020.pdf | ||
| A03_-_Construction_Contract_Administration.docx | DOCX document | |
| A04_SOW_Attch_1_FORA_Mx_septic_layout_(1).pdf | ||
| B03_DOL_Wage_Determination__NC20240069.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RISER AND LATERAL LINE
SHALL BE SCHED 40 PVC
THREADED SLOTTED PLUG
GRADE
THREADED CAP ASSEMBLY
6" ABOVEGROUND
6"
NOTES:
1. THIS DETAIL SHOWS TYPICAL CLEAN OUT INSTALLATION. THIS DOES
NOT INDICATE SLOPE OF LATERAL LINES. INSTALL CLEANOUTS IN
LOCATIONS AND IN THE DIRECTION OF THE FLOW AS INDICATED IN
THE SCOPE OF WORK AND SITE PLANS.
NOTES:
1. TANKS SHALL BE PROVIDED BY A VENDOR APPROVED BY THE ON SITE
WATER PROTECTION BRANCH OF NC DEPT OF PUBLIC HEALTH AND
HUMNAN SERVICES (NCDHHS) TO MANUFACTURE SEPTIC TANKS.
OTHER VENDORS' TANKS SHALL OBTAIN APPROVAL ACCORDING TO
NORTH CARONLINA GENERAL STATUE CHAPTER 90A ARTICLE 5.
HTTPS://EHS.DPH.NCDHHS.GOV/OSWP/DOCS/RULES/SEWAGELAWS.PDF.
2. TANKS NOT MANUFACTURED IN NORTH CAROLINA SHALL PROVIDE
SIMILAR STATE APPROVED MANUFACTURER APPROVAL. SUBMIT WITH
PRODUCT DATA.
3. THIS DETAIL IS TYPICAL. EXACT DIMENSIONS MAY VARY.
SPECIFICATIONS IN THE SCOPE OF WORK SHALL BE FOLLOWED:
STAINLESS STEEL HANDLES, RISERS, ETC PER THE SCOPE OF WORK
4. THE CONTRACTOR SHALL FILL TANK WITH CLEAN WATER AFTER
INSTALLATION TO SHOW WATER TIGHT SEAL. WATER SHALL BE LEFT
IN TANK 24 HOURS TO CHECK FOR LEAKS.
SCALE:
TYPICAL CLEANOUT1 1" = 1'-0"
SCALE:
TYPICAL 1,000 GALLON CONCRETE SEPTIC TANK3 NOT TO SCALE
SCALE:
BASIS OF DESIGN FOR SEPTIC DRAINFIELD INFILTRATION CHAMBERS2 NTS
NOTES:
1. THIS DETAIL IS ONLY TO SHOW THE BASIS OF DESIGN. TRENCHES FOR
THE SEPTIC SYSTEM SHALL BE 36 INCHES WIDE. ACTUAL PRODUCTS
FOR THE INFILTRATION CHAMBERS SHALL BE AT THE DISCRETION OF
THE CONTRACTOR. PRODUCTS SHALL MEET THE REQUIREMENTS OF
NORTH CAROLINA ADMINISTRATIVE CODE FOR SEPTIC SYSTEM
PRODUCTS AS APPROVED BY NCDHHS.
HTTPS://EHS.DPH.NCDHHS.GOV/OSWP/APPROVEDPRODUCTS.HTM
AutoCAD SHX Text Sheet
AutoCAD SHX Text Scale
AutoCAD SHX Text Project
AutoCAD SHX Text Date
AutoCAD SHX Text Revision/Issue
AutoCAD SHX Text Project Name and Address
AutoCAD SHX Text Firm Name and Address
AutoCAD SHX Text No.
AutoCAD SHX Text Date
AutoCAD SHX Text General Notes
AutoCAD SHX Text
REPLACE SEPTIC SYSTEM
AutoCAD SHX Text
AT FT RALEIGH MAINTENANCE
AutoCAD SHX Text
1403 PEAR PAD RD
AutoCAD SHX Text
MANTEO, NC 27954
AutoCAD SHX Text
PMIS 329246
AutoCAD SHX Text 1/9/2024
AutoCAD SHX Text As Noted
AutoCAD SHX Text C3
| Sheets and Views |
| FORA Mx septict-VIP Details |
File details come from the government source that posted it. Updated .