A04_SOW_Attch_2_FORA_Mx_septic_details.pdf

PDF 1 MB Posted

Attached to
Cape Hatters NS Fort Raleigh: SEPTIC SYSTEM
Solicitation number
140P5324R0020
Issued by

About this file

This document package includes technical specifications and drawings for replacing the septic system at Fort Raleigh Maintenance in Manteo, North Carolina. The scope of work calls for installing a 1,000 gallon concrete septic tank, PVC riser and lateral lines, cleanout assemblies, and an infiltration field using chambers that meet North Carolina standards. The contractor must use tank and product manufacturers approved by the North Carolina Department of Health and Human Services. Tank installation must be water tested and approved. This work supports Solicitation 140P5324R0020 issued by the National Park Service Southeast Region for the Cape Hatteras National Seashore Fort Raleigh site. The specifications provide requirements for materials, installation, and testing of the new septic system.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RISER AND LATERAL LINE

SHALL BE SCHED 40 PVC

THREADED SLOTTED PLUG

GRADE

THREADED CAP ASSEMBLY

6" ABOVEGROUND

6"

NOTES:

1. THIS DETAIL SHOWS TYPICAL CLEAN OUT INSTALLATION. THIS DOES

NOT INDICATE SLOPE OF LATERAL LINES. INSTALL CLEANOUTS IN

LOCATIONS AND IN THE DIRECTION OF THE FLOW AS INDICATED IN

THE SCOPE OF WORK AND SITE PLANS.

NOTES:

1. TANKS SHALL BE PROVIDED BY A VENDOR APPROVED BY THE ON SITE

WATER PROTECTION BRANCH OF NC DEPT OF PUBLIC HEALTH AND

HUMNAN SERVICES (NCDHHS) TO MANUFACTURE SEPTIC TANKS.

OTHER VENDORS' TANKS SHALL OBTAIN APPROVAL ACCORDING TO

NORTH CARONLINA GENERAL STATUE CHAPTER 90A ARTICLE 5.

HTTPS://EHS.DPH.NCDHHS.GOV/OSWP/DOCS/RULES/SEWAGELAWS.PDF.

2. TANKS NOT MANUFACTURED IN NORTH CAROLINA SHALL PROVIDE

SIMILAR STATE APPROVED MANUFACTURER APPROVAL. SUBMIT WITH

PRODUCT DATA.

3. THIS DETAIL IS TYPICAL. EXACT DIMENSIONS MAY VARY.

SPECIFICATIONS IN THE SCOPE OF WORK SHALL BE FOLLOWED:

STAINLESS STEEL HANDLES, RISERS, ETC PER THE SCOPE OF WORK

4. THE CONTRACTOR SHALL FILL TANK WITH CLEAN WATER AFTER

INSTALLATION TO SHOW WATER TIGHT SEAL. WATER SHALL BE LEFT

IN TANK 24 HOURS TO CHECK FOR LEAKS.

SCALE:

TYPICAL CLEANOUT1 1" = 1'-0"

SCALE:

TYPICAL 1,000 GALLON CONCRETE SEPTIC TANK3 NOT TO SCALE

SCALE:

BASIS OF DESIGN FOR SEPTIC DRAINFIELD INFILTRATION CHAMBERS2 NTS

NOTES:

1. THIS DETAIL IS ONLY TO SHOW THE BASIS OF DESIGN. TRENCHES FOR

THE SEPTIC SYSTEM SHALL BE 36 INCHES WIDE. ACTUAL PRODUCTS

FOR THE INFILTRATION CHAMBERS SHALL BE AT THE DISCRETION OF

THE CONTRACTOR. PRODUCTS SHALL MEET THE REQUIREMENTS OF

NORTH CAROLINA ADMINISTRATIVE CODE FOR SEPTIC SYSTEM

PRODUCTS AS APPROVED BY NCDHHS.

HTTPS://EHS.DPH.NCDHHS.GOV/OSWP/APPROVEDPRODUCTS.HTM

AutoCAD SHX Text Sheet

AutoCAD SHX Text Scale

AutoCAD SHX Text Project

AutoCAD SHX Text Date

AutoCAD SHX Text Revision/Issue

AutoCAD SHX Text Project Name and Address

AutoCAD SHX Text Firm Name and Address

AutoCAD SHX Text No.

AutoCAD SHX Text Date

AutoCAD SHX Text General Notes

AutoCAD SHX Text

REPLACE SEPTIC SYSTEM

AutoCAD SHX Text

AT FT RALEIGH MAINTENANCE

AutoCAD SHX Text

1403 PEAR PAD RD

AutoCAD SHX Text

MANTEO, NC 27954

AutoCAD SHX Text

PMIS 329246

AutoCAD SHX Text 1/9/2024

AutoCAD SHX Text As Noted

AutoCAD SHX Text C3

Sheets and Views
FORA Mx septict-VIP Details

File details come from the government source that posted it. Updated .