Upholstery Fabric sample standard

(1) Upholstery Fabric Material for Army Family Housing furniture

Acceptable

Variable range

Width 54 ~ 60 inches (137~152.4cm) (+/‐) 1 inch

Length 1 yard(36 inches) (+/‐) 1 inch

Weight 550 grams per yard (+/‐) 15 %

Main Color Charcoal grey

Patten Horizontal stripes pattern

Water proof

발수성능기준KS K ISO 4920 or KS K 0590 : 2008

시험편을 금속틀에 끼워 물 250ml를 부어 25‐30초 사이에

시험편과의 15.2cm 의거리에서 뿌리고 젖은 쪽을 밑으로 하여

물방울을 털어낸후 발수도 판정표와 비교하여 판정함 등급 4 이상

합격 Water repellency standard

Put the test piece in a metal frame, pour 250ml of water, spray it at a distance of 15.2cm from the test piece in 25‐30 seconds. After that, shake off the water droplets with the wet side down, and compare the water repellency rating table to pass grade 4 or higher.

Flame resistant

방염성능기준 [시행 2017. 7. 26.] [소방청고시 제2017‐1호 제4조(방염성능의 기준)

6. 소파∙의자의 방염성능기준은 다음 각 목에 적합하여야 한다.

가. 담배법에 의한 시험은 1시간 이내에 발화 및 연기가 발생하지

않아야 할 것 Flame‐retardant performance standards.

The flame‐retardant performance standards of sofas and chairs shall comply with the following items.

The test will be in accordance of

Fire Department Notice No. 2017‐1, article 4, the Tobacco test and ignition and smoke should not occur within 1 hour.

(2) Upholstery Fabric Material for GFOQ entertainment area furniture

Acceptable

Variable range

Width 54 ~ 60 inches (137~152.4cm) (+/‐) 1 inch

Length 1 yard(36 inches) (+/‐) 1 inch

Weight 350 grams per yard (+/‐) 15 %

Main Color Brown

Patten Sandglass Pattern

Water proof

발수성능기준KS K ISO 4920 or KS K 0590 : 2008

시험편을 금속틀에 끼워 물 250ml를 부어 25‐30초 사이에

시험편과의 15.2cm 의거리에서 뿌리고 젖은 쪽을 밑으로 하여

물방울을 털어낸후 발수도 판정표와 비교하여 판정함 등급 4 이상

합격 Water repellency standard

Put the test piece in a metal frame, pour 250ml of water, spray it at a distance of 15.2cm from the test piece in 25‐30 seconds. After that, shake off the water droplets with the wet side down, and compare the water repellency rating table to pass grade 4 or higher.

Flame resistant

방염성능기준 [시행 2017. 7. 26.] [소방청고시 제2017‐1호 제4조(방염성능의 기준)

6. 소파∙의자의 방염성능기준은 다음 각 목에 적합하여야 한다.

가. 담배법에 의한 시험은 1시간 이내에 발화 및 연기가 발생하지

않아야 할 것 Flame‐retardant performance standards.

The flame‐retardant performance standards of sofas and chairs shall comply with the following items.

The test will be in accordance of

Fire Department Notice No. 2017‐1, article 4, the Tobacco test and ignition and smoke should not occur within 1 hour.

(3) Upholstery Fabric Material for GFOQ outdoor furniture

Acceptable

Variable range

Width 54 ~ 60 inches (137~152.4cm) (+/‐) 1 inch

Length 1 yard(36 inches) (+/‐) 1 inch

Weight 300 grams per yard (+/‐) 15 %

Main Color Cream Brown

Patten Reticulated pattern

Water proof

발수성능기준KS K ISO 4920 or KS K 0590 : 2008

시험편을 금속틀에 끼워 물 250ml를 부어 25‐30초 사이에

시험편과의 15.2cm 의거리에서 뿌리고 젖은 쪽을 밑으로 하여

물방울을 털어낸후 발수도 판정표와 비교하여 판정함 등급 4 이상

합격 Water repellency standard

Put the test piece in a metal frame, pour 250ml of water, spray it at a distance of 15.2cm from the test piece in 25‐30 seconds. After that, shake off the water droplets with the wet side down, and compare the water repellency rating table to pass grade 4 or higher.

Flame resistant

방염성능기준 [시행 2017. 7. 26.] [소방청고시 제2017‐1호 제4조(방염성능의 기준)

6. 소파∙의자의 방염성능기준은 다음 각 목에 적합하여야 한다.

가. 담배법에 의한 시험은 1시간 이내에 발화 및 연기가 발생하지

않아야 할 것 Flame‐retardant performance standards.

The flame‐retardant performance standards of sofas and chairs shall comply with the following items.

The test will be in accordance of

Fire Department Notice No. 2017‐1, article 4, the Tobacco test and ignition and smoke should not occur within 1 hour.