A02 - Apendix A SLAPS COMPOND.pdf

PDF 675 KB Posted

Attached to
FUSRAP SITE / JANITORIAL SUPPORT Federal contract opportunity
Solicitation number
W912P920R0061
Issued by
Department of the Army Corps of Engineers Engineering District St Louis

About this file

This document includes an appendix and federal contract opportunity related to general site support services for two modular project offices and a modular laboratory building at a Corps of Engineers FUSRAP St. Louis Airport Project Sites compound. The appendix provides details on building layouts, HVAC equipment, doors and windows, fire ratings, and draftstopping and penetration requirements.

The federal contract opportunity solicitation requests proposals for furnishing all necessary labor, equipment, materials and supplies to satisfactorily perform general maintenance and janitorial services at the three buildings. Required services include minor building construction repairs, general servicing, cleaning services, and maintaining the buildings in a sanitary condition. The contractor must provide 2.5 full-time equivalents, including two full-time carpenter maintenance personnel for site support and a part-time janitorial employee. The solicitation was issued by the Department of the Army Corps of Engineers Engineering District St. Louis for the FUSRAP Site/Janitorial Support contract.

View the file

Other files for this federal contract opportunity

Other files attached to FUSRAP SITE / JANITORIAL SUPPORT, newest first.
File Type Posted
Solicitation.pdf PDF
A02 - Bid Schedule.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

APPENDIX A

N b3cocvlj Text Box Mod Building 110 James S. McDonnell Blvd. Hazelwood, MO

A

G

B

C

D

E

F

DRAFTSTOP LOCATION

3 TON BARD

T36S1DB09VPXXXE HEAT

PUMP w/ 9 KW AUX. HEAT

STRIPS, 1100 CFM @ .3 IWC

ESP, 208v,3 Ø EQUIPPED w/

COMMERCIAL VENTILATOR

FRESH AIR INTAKE (TYPICAL)

8"X16" OVERHEAD

GALVANIZED STEEL

RETURN DUCT w/ 24"X24"

RETURN GRILLS, STUBBED

INTO PLENUM LINED with

1/2" GYPSUM. (TYPICAL)

30"x48" 30"x48"

60" Ø"

60" Ø"

1 1

B

T2

B

T2

B

T2

B

T2

B

T2

B

T2

C

T3

B

T2

B

T2

B

T3

B

T3

B

T3

B

T2

B

T2

B

T2

ICE

MAKER

1 72x80

DOOR SCHEDULE

# DESCRIPTION QTYSIZE HARDWARE

36x80 1

CLOSER & PANIC

HARDWARE, EXT LEVER

PRIVACY LEVER SET

2 72x80 1 CLOSER & PANIC

HARDWARE, EXT LEVER

36x80 3

PASSAGE LEVER SET

48x80 1 PASSAGE LEVER SET

SOLID CORE IMPERIAL OAK - 45 MIN RATED

w/ REDIFRAME

SOLID CORE IMPERIAL OAK - 20 MIN RATED

w/ REDIFRAME

18 GA INSULATED STEEL W/ 6X30 VIEW

BLOCK W/ STEEL FRAME & MULLION

18 GA INSULATED STEEL W/ 22X30 VIEW BLOCK

W/ STEEL FRAME & MULLION

SOLID CORE IMPERIAL OAK - 20 MIN RATED -

22X30 WIRE GLASS VIEW BLOCK w/ REDIFRAME

36x80 9 PASSAGE LEVER SETSOLID CORE IMPERIAL OAK - 20 MIN RATED - 22X30 WIRE GLASS VIEW BLOCK w/ REDIFRAME

36x80 1 CLOSER & PANIC

HARDWARE, EXT LEVER

18 GA INSULATED STEEL W/ 6X30 VIEW

BLOCK W/ STEEL FRAME & MULLION

1 48x24

WINDOW SCHEDULE

# DESCRIPTION QTYSIZE

4HORIZONTAL SLIDER METAL FRAME / CLEAR LOW-E INSULATED 56" AFF

W/ 1" VINYL BLINDS

36x80 2 PASSAGE LEVER SETHOLLOW CORE STEEL DOOR - 20 MIN RATED -

22X30 WIRE GLASS VIEW BLOCK w/ REDIFRAME

36x80 26 KEYED LEVER SETSOLID CORE IMPERIAL OAK w/

REDIFRAME

& CLOSER

& CLOSER

& CLOSER

36x80 410 PASSAGE LEVER SETSOLID CORE IMPERIAL OAK w/ REDIFRAME

1 HOUR FIRE RATED WALL

& CLOSER

& CLOSER

DRAFTSTOPPING NOTES:

1. SEE FLOOR PLAN FOR REQUIRED DRAFTSTOPPING LOCATIONS

2. DRAFTSTOPPING SHALL EXTEND CONTINUOUSLY FOR THE FULL

LENGTH OF MATELINES AND TRUSSES WHERE INDICATED

3. DRAFTSTOPPING SHALL EXTEND CONTINUOUSLY FULL HEIGHT FROM

ROOF SHEATHING TO FINISH CEILING MATERIAL.

4. DRAFTSTOPPING MATERIAL SHALL BE MINIMUM 12 INCH GYPSUM

BOARD, 3/8 INCH PLYWOOD OR 7

16 INCH OSB.

5. ALL DRAFTSTOPPING EDGES SHALL BE TIGHTLY FIT, INCLUDING THE

ANNULAR SPACE AROUND MECHANICAL AND ELECTRICAL

PENETRATIONS, SO AS TO PREVENT THE PASSAGE OF AIR.

PENETRATION OF FIRE RESISTANT WALLS AND CEILINGS:

1. COMBUSTIBLE CABLES AND WIRES, COMBUSTIBLE PIPES, TUBES AND

CONDUIT SHALL MEET TESTING REQUIREMENTS OF ASTM E119 AS PART OF

THE FIRE RESISTANT ASSEMBLY OR SHALL HAVE THROUGH-PENETRATION

FIRESTOP SYSTEMS LISTED AND TESTED AS PER ASTM EB14 AND BE TESTED

AT A POSITIVE PRESSURE DIFFERENTIAL BETWEEN THE EXPOSED AND

UNEXPOSED SURFACES OF NOT LESS THAN 0.01 INCH OF WATER AND HAVE

AN 'F' RATING OF AT LEAST 1 HOUR BUT NOT LESS THAN THE RATING OF THE

ASSEMBLY.

2. CABLES AND WIRE WITHOUT COMBUSTIBLE INSULATIONS AND

NON-COMBUSTIBLE PIPES, TUBES AND CONDUITS SHALL BE PROTECTED AS

DESCRIBED ABOVE OR SHALL HAVE THE ANNULAR SPACE FILLED WITH A

MATERIAL MEETING THE REQUIREMENT OF ASTM E119 TESTED UNDER A

POSITIVE PRESSURE DIFFERENTIAL OF 0.01 INCH OF WATER FOR A TIME

PERIOD EQUIVALENT TO THE RATING OF THE ASSEMBLY.

3. ELECTRICAL BOXES SHALL BE METAL OR LISTED FOR USE IN FIRE RESISTANT

ASSEMBLIES AND SHALL NOT EXCEED 16 SQUARE INCHES. BOXES ON

OPPOSITE SIDES OF FIRE RESISTANT WALLS SHALL BE SEPARATED BY A

MINIMUM HORIZONTAL DISTANCE OF 24 INCHES.

4. DUCTS PENETRATING FIRE RESISTANT CEILINGS SHALL HAVE AN

ACCESSIBLE LISTED FIRE DAMPER LOCATED AT THE CEILING LINE.

5. ALL FIRE RATED DOORS SHALL HAVE LISTED DOOR, FRAME AND HARDWARE

NO LESS THAN THE TIME RATING SPECIFIED ON THE FLOOR PLAN. IN

ADDITION FIRE RATED DOORS SHALL BE EQUIPPED WITH SELF CLOSING

DEVICES UNLESS OTHERWISE NOTED.

6. ALL DUCT PENETRATIONS OF 1 HOUR RATED CORRIDORS MUST BE EQUIPPED

WITH COMBINATION SMOKE AND FIRE DAMPERS. EXCEPTION: SMOKE

DAMPERS ARE NOT REQUIRED IN CORRIDOR PENETRATION WHERE THE

DUCT IS CONSTRUCTED OF STEEL NOT LESS THAN 0.019 INCH IN THICKNESS

AND THERE ARE NO OPENINGS SERVING THE CORRIDOR.

7. WOOD STUD WALLS: 1 HOUR PER UL# U305 OR GYPSUM ASSOCIATION

WP3520 / WP3605 - 1 LAYER OF 58" TYPE-X GYPSUM EACH SIDE OF WALL

ONE HOUR FIRE RATING DETAIL

8'-0" MAX. FOR 2X4 SPF#2 @ 16" O.C.

14'-0" MAX. FOR 2X6 SPF#2 @ 16" O.C.

SEE NOTES

SIDE OF 2X4 @ 16" O.C.

GYPSUM BOARD EACH

1 LAYER 5/8" TYPE `X'

5/8" TYPE `X' GYPSUM BOARD

BE USED IN LIEU OF 3)

2X4 CEILING ASSEMBLIES, 2 NAILS MAY

FROM RIM TO EACH CEILING JOIST. (AT

JOIST TO EACH STUD (16" O.C.) AND

3-.131 X 3 1/2" GUN NAILS FROM RIM

SUSPENDED CEILING APPROX

2"x FRAMING MEMBERS, SEE BELOW

7'-6" CEILING HEIGHT

UL#U305 OR GA WP3520 /

WP3605 IN ACCORDANCE

W/ IBC 708.4 EXCEPTION #3

UL#U305 OR GA

WP3520 / WP3605

FLOOR PLAN PAGE: 3 / 11

SOUTHEAST MODULAR MFG.

ELLAVILLE, LLC

1619 STATE ROAD 26 WEST* ELLAVILLE, GA 31806

SMM-20118 A-G 84'X60' (81'-8"x60'-0" ACTUAL) BUSINESS

DATE:

SCALE:

CODES:

02-28-19

16"=1'-0"

MO

REVISION: 6-7-19

DESTINATION: HAZELWOOD, MO

THIRD PARTY:

HWC

HILBORN, WERNER, CARTER & ASSOCIATES

1627 SOUTH MYRTLE AVE.

CLEARWATER, FL 33756

ENGINEER:

JAMES ALLEN CHAPMAN, P.E.

159 BARNES RD, AMERICUS, GA

HWC#: 2724-0021

smithj stamp1 smithj stamp1 b3cocvlj Highlight b3cocvlj Highlight b3cocvlj Highlight b3cocvlj Highlight b3cocvlj Highlight b3cocvlj Line b3cocvlj Rectangle b3cocvlj Underline b3cocvlj Text Box

RESTRICTED AREA

b3cocvlj Text Box Mod Building 112 James S. McDonnell Blvd Hazelwood, MO

April 15, 2019

VALID

APPROVEDA

04 15 2019

Mod Building 114 James S. McDonnell Blvd Hazelwood, MO smithj stamp1

APPENDIX A
McDonnell Layout DOC102419 (003)
110 Mod Bldg Office Layout a (002)
112 USACE FUSRAP Modular Laboratory Building Layout (003)
114 USACE Modular Building Layout (002)