A.1 Part 1-B Design Plans 2 of 2.pdf
PDF 26 MB Posted
- Attached to
- Operation of UNH Water Treatment Plant
- Solicitation number
- 212026943
- Issued by
- Strafford County, New Hampshire
About this file
Summary of Design Plans for UNH Water Treatment Plant
This is a set of 90% design submittal documents for the Water Treatment Plant Replacement project at the University of New Hampshire in Durham, New Hampshire, prepared by Woodard & Curran engineering firm. The project, identified as UNH Project ID #2008-0038, encompasses comprehensive mechanical, plumbing, fire protection, electrical, and instrumentation/controls design drawings for a complete water treatment facility renovation. The design includes detailed plans for process sections, gatehouse demolition and reconstruction, oyster pump station mechanical systems, Lamprey River/Spruce Hole well raw water pump stations, and all associated mechanical schedules and details. The drawings are presented at 90% completion level and include multiple sheets at various scales, incorporating specifications for HVAC ductwork and piping systems, sanitary and storm drainage, plumbing fixtures and schedules, fire alarm systems with addressable detection and notification devices, electrical power distribution, lighting, controls, and SCADA panel configurations for automated system operation.
The design documents detail extensive mechanical and electrical infrastructure including boiler systems with hot water supply and return piping, multiple air handling units with associated ductwork distribution, chilled water systems, and complete plumbing installations with fixtures specified for laboratory use, personnel facilities, and emergency safety equipment such as eyewash and shower stations. Fire protection systems include wet and dry-pipe sprinkler coverage with appropriate alarm valves and monitoring. Electrical systems incorporate power distribution panels, lighting design for multiple building levels and pipe gallery areas, and integrated instrumentation with SCADA control panels for the main treatment facility, Oyster River supply operations, chemical feed control, and raw water handling. All design work reflects compliance with current codes including NFPA standards, the National Electrical Code, and applicable New Hampshire building and fire codes, with provisions for future operational staffing and management of the water treatment facility.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W
OO
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
M-104
ME
CH
AN
IC
AL
P
RO
CE
SS
S
EC
TI
ON
S
22x34 SHEET 1:1
PART 1B 90% DESIGN SUBMITTAL
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
M-105
ME
CH
AN
IC
AL
P
RO
CE
SS
SE
CT
IO
NS
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
M-106
ME
CH
AN
IC
AL
P
RO
CE
SS
S
EC
TI
ON
S
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
M-201
GA
TE
H
OU
SE
D
EM
OL
IT
IO
N
PL
AN
S
AN
D
CR
OS
S
SE
CT
IO
NS
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
M-202
GA
TE
H
OU
SE
P
LA
NS
A
ND
CR
OS
S
SE
CT
IO
NS
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
M-301
OY
ST
ER
P
UM
P
ST
AT
IO
N
ME
CH
AN
IC
AL
P
LA
N
CR
OS
S
SE
CT
IO
N
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
M-302
OY
ST
ER
P
UM
P
ST
AT
IO
N
ME
CH
AN
IC
AL
CR
OS
S
SE
CT
IO
NS
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
M-401
L A
M P
R E
Y
R
I V
E R
S
P R
U C
E
H
O L
E
W
E L
L
R A
W
W
A T
E R
P
U M
P
S
T A
T I O
N
D
E M
O L
I T
I O
N
P L
A N
S
A
N D
C
O
S
C
T I O
N S
PART 1B 90% DESIGN SUBMITTAL
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
M-402
L A
M P
R E
Y
R
I V
E R
S
P R
U C
E
H
O L
E
W
E L
L
R A
W
W
A T
M
P
S
T A
T I O
N
P
L A
N S
A N
D
C
R O
C
T I O
N S
PART 1B 90% DESIGN SUBMITTAL
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
M-501
ME
CH
AN
IC
AL
S
CH
ED
UL
ES
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
M-502
ME
CH
AN
IC
AL
S
CH
ED
UL
ES
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
M-503
ME
CH
AN
IC
AL
S
CH
ED
UL
ES
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
M-504
ME
CH
AN
IC
AL
D
ET
AI
LS
I
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
M-505
ME
CH
AN
IC
AL
D
ET
AI
LS
II
22x34 SHEET
TIGHT SHUT-OFF VALVE
FD (3 HR) FIRE DAMPER (3 HOUR RATED)
S2 4
SUPPLY DIFFUSER ( TYPE 2 )
400 CFM EA
DIFFUSER DESCRIPTION
QUANTITY
FIRE DAMPER (1 1/2 HOUR RATED)
( SEE REG., GRILLES & DIFF SCHEDULE )
BD
DN
10'-0" FL
10.0 gpm
V
ACOUSTICALLY LINED DUCT
LENGTH, 10,000 BTU/HR) WITHOUT DAMPER
RADIATION I.D. ( TYPE A, 10'-0" FINNED1
10'-0" FL/D
10.0 GPM LENGTH, 10,000 BTU/HR) WITH DAMPER
A M10.1
ACV 2 - WAY
ACV 3 - WAY
BALANCE VALVE
BACKDRAFT DAMPER
CAP - PIPE
CHECK VALVE
COMBINATION BALANCING, FLOW MEASURING &
DUCT SECTION - SUPPLY/OUTDOOR AIR
DUCT SECTION - RETURN AIR
DUCT TURNING VANES
FLEXIBLE DUCT
ISOLATION VALVE
GLOBE VALVE
LOCKSHIELD GATE VALVE
LOUVER
MOTORIZED DAMPER
PETCOCK FOR GAUGE CONNECTION
PIPE ANCHOR
PIPE GUIDE
PITCH DOWN
PRESSURE GAUGE
PRESSURE REDUCING VALVE
PRESSURE RELIEF VALVE
RADIATION I.D. ( TYPE A, 10'-0" FINNED
REDUCER - CONCENTRIC
REDUCER - ECCENTRIC
RETURN AIR
SECTION I.D. ( SECTION A SHOWN ON DWG. M10.1)
SMOKE DAMPER
STRAINER
SUPPLY AIR
TAKE - OFF FROM BOTTOM OF PIPE
TAKE - OFF FROM TOP OF PIPE
TEMPERATURE SENSOR
UNION
VOLUME DAMPER
DUCT DIAMETER
S (SUPPLY) R (RETURN)
E (EXHAUST) T (TRANSFER)
DESCRIPTIONSYMBOL
S
M
F
DUCT MOUNTED SMOKE DETECTOR
TS
DESCRIPTIONSYMBOL
NEW EQUIPMENT
SD
NEW SUPPLY PIPING
NEW RETURN PIPING
NEW DUCTWORK
PIPE DOWN
PIPE UP
DUCT SECTION - EXHAUST AIR
DIFFERENTIAL PRESSURE SENSORDPS
STATIC PRESSURE SENSORSPS
W
OO
DA
RD
CU
RR
AN
U
N H
P R
O
JE
C T
ID
-0
W
AT
ER
T R
EA
TM
EN
T
PL
AN
T R
EP
LA
C
EM
EN
T
U N
IV
ER
SI
TY
O F
N
EW
H
AM
PS
H
IR
E
D U
R H
AM
, N
EW
H
AM
PS
H
IR
E
R E
P R
O D
U C
T
IO
N O
R M
O D
IF
IC
A T
IO
N
W
IT
H O
U T
W R
IT
T
E N
P E
R M
IS
S
IO
N
IS
P
R O
H
IB
IT
E
D
T H
IS
D
O C
U M
E N
T
IS
T H
E P
R O
P E
R T
Y O
F W
O O
D A
R D
C
U R
R A
N
IN
C A
N D
IT
S
C L
IE
N T
B
A
C
D
B
A
C
D
2 3 4 5 61
2 3 4 5 61
W
OO
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B Y:
D
AT
E D
ES
C
R
IP
TI
O
N R
EV D
R
AW
N
B Y:
JOB NO.:
SCALE:
DATE:
SHEET: OF
1/8" = 1'-0"
M J
BP
H
M J
16621
MAY 5, 2017
H100.1
LE
GE
N D
G
EN
E R
AL
N
OT
E S
PART 1B 90% DESIGN SUBMITTAL
210128
ABBREV DESCRIPTION
LPCR LOW PRESSURE CONDENSATE
RETURN (LESS THAN 15 PSI)
LPS LOW PRESSURE STEAM(LESS THAN
15 PSI)
LRA LOCKED ROTOR AMPS
LSGV LOCK & SHIELD GATE VALVE
LWT LEAVING WATER TEMPERATURE
M MOTORIZED DAMPER
MAX MAXIMUM
MBH 1000 BRITISH THERMAL UNITS
MCA MINIMUM CIRCUIT AMPS
MIN MINIMUM
MOPD MAXIMUM OVERCURRENT
PROTECTIVE DEVICE
MPCR MEDIUM PRESSURE CONDENSATE
RETURN(16-30 PSIG)
MPS MEDIUM PRESSURE STEAM (16-30
PSIG)
NA NOT APPLICABLE
NC NOISE CRITERIA
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NTS NOT TO SCALE
OA OUTSIDE AIR
OC ON CENTER
OED OPEN END DUCT
OS&Y OUTSIDE SCREW & YOKE GATE
VALVE
PD PRESSURE DROP
PRD PRESSURE RELIEF DAMPER
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
RET RETURN
RET RETURN
RL RIFRIGERANT LIQUID
RLA RATED LOAD AMPERES
RPM REVOLUTIONS PER MINUTE
RS REFRIGERANT SUCTION
S SMOKE DAMPER
S/F SMOKE AND FIRE COMBINATION
DAMPER
SP STATIC PRESSURE
SS STAINLESS STEEL
SUP SUPPLY
TEMP TEMPERATURE
TT THERMOSTATIC TRAP
TYP TYPICAL
V VOLUME DAMPER
VFD VARIABLE FREQUENCY DRIVE
W/ WITH
W/O WITHOUT
WC WATER COLUMN
WG WATER GAUGE
WPD WATER PRESSURE DROP
WWMS WELDED WIRE MESH SCREEN
Z ZONE DAMPER
PREFIX OF X EXISTING
ABBREV DESCRIPTION
ACV AUTOMATIC CONTROL VALVE
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
ALD ACOUSTICAL LINED DUCT
AMS AIRFLOW MEASURING STATION
APD AIR PRESSURE DROP
ATC AUTOMATIC TEMPERATURE
CONTROL
B BAROMETRIC DAMPER
BD BACKDRAFT DAMPER
BPD BYPASS DAMPER
BTU BRITISH THERMAL UNITS
CBD COUNTERBALANCED BACKDRAFT
DAMPER
CFM CUBIC FEET PER MINUTE
CHWR CHILLED WATER RETURN
CHWS CHILLED WATER SUPPLY
CO CLEANOUT
CTE CONNECT TO EXISTING
CWR CONDENSER WATER RETURN
CWS CONDENSER WATER SUPPLY
DCW DOMESTIC COLD WATER
DEG.F DEGREES FAHRENHEIT
DHW DOMESTIC HOT WATER
DIA DIAMETER
DN DOWN
EAT ENTERING AIR TEMPERATURE
ESP EXTERNAL STATIC PRESSURE
EWT ENTERING WATER TEMPERATURE
EXG EXISTING
EXH EXHAUST
F&T FLOAT & THERMOSTATIC TRAP
FD FIRE DAMPER
FL FINNED LENGTH OF RADIATION
FM FLOW METER
FOR FUEL OIL RETURN
FOS FUEL OIL SUPPLY
FPF FINS PER FOOT
FPI FINS PER/INCH
FPM FEET PER MINUTE
FT FEET
FT-HD FEET OF HEAD
FT-WG FEET WATER GAUGE
FTR FIN TUBE RADIATOR
GAL GALLONS
GPM GALLONS PER MINUTE
HP HORSEPOWER
HPCR HIGH PRESSURE CONDENSATE
RETURN (OVER 30 PSIG)
HPS HIGH PRESSURE STEAM (OVER
30PSIG)
HRR HEAT RECOVERY RETURN
HRS HEAT RECOVERY SUPPLY
HWR HOT WATER RETURN
HWS HOT WATER SUPPLY
IN INCHES
LAT LEAVING AIR TEMPERATURE
REF.
W
UP
REF.
V
V
V V
VV
V
V
V
V
V
V
V
VV
M
M
V
VV
V
TSTS
TS
TS
TS TS
TS
TS
V
V V
A
D
B C
LABORATORY
535 SF
RECORDS
106B
181 SF
IT ROOM
128 SF
DRY STO
88 SF
LAB STO
106A
124 SF
BREAK ROOM
223 SF
STAFF OFFICE
333 SF
SUPERVISOR
127 SF
CONFERENCE ROOM
375 SF
MENS TOILET
168 SF
CORRIDOR
100CRA
952 SF
ELEC ROOM
120E
427 SF
MECH ROOM
120G
355 SF
CONTROL ROOM
120B
254 SF
UNISEX CHANGING
73 SF
UNISEX CHANGING
72 SF
TOILET
106 SF
LAB STO
130A
114 SF
TRAINING LAB
536 SF
WATER TREATMENT
6099 SF
CHEMICAL STORAGE
120A
1027 SFMAINTENANCE AREA
692 SF
WOMENS TOILET
169 SF
JAN
EVAPORATING UNIT
S3
S3
1S3
S3
S3
S3
S3
E2
E2
E2
E2
E2
E2
E2
A.H.
CUH
CUH
BOILERS
PUMPS
E1
R2
R2
R5
R3
R7
R5
"ø
12"ø
12"ø
"ø
18"x16"
"x
18"x12"
8"ø
8" ø
10"ø
8"ø8"ø
10"ø
16"x14"10"ø
8" ø
20" X 12" UP
18" X 12" UP
6"ø
20"x12"
6"ø 6"ø
12"x12" 10"ø
10"ø
10"ø
10"ø 10"ø
10" X 16" UP
6"ø
6"ø 30" X 18" UP
8"ø
18" X 18"
INTAKE LOUVER
24" X 18"
INTAKE LOUVER
E6
1 E5
UP TO EXHAUST FAN ON ROOF
GAS FIRED UH
GAS FIRED UH
EF
14"x12"
UP TO ATTIC
S5
16"x10"
6"x6"
S3
DN
DN
6"ø
S3
TO AHU-1
TO AHU-2 TO AHU-3
20"x12"
8"ø
"ø
18"x14" 18"x16"
16"x14"
"x
" 16" X 14" UP
20"x16"
20" X 16" UP
"ø
"ø
6"ø 20" X 18" UP
18" X 16" UP
20"x18"
"x
8"ø
12"ø 12"x14"
10"ø
10"ø
W
OO
DA
RD
CU
RR
AN
U
N H
P R
O
JE
C T
ID
-0
W
AT
ER
T R
EA
TM
EN
T
PL
AN
T R
EP
LA
C
EM
EN
T
U N
IV
ER
SI
TY
O F
N
EW
H
AM
PS
H
IR
E
D U
R H
AM
, N
EW
H
AM
PS
H
IR
E
R E
P R
O D
U C
T
IO
N O
R M
O D
IF
IC
A T
IO
N
W
IT
H O
U T
W R
IT
T
E N
P E
R M
IS
S
IO
N
IS
P
R O
H
IB
IT
E
D
T H
IS
D
O C
U M
E N
T
IS
T H
E P
R O
P E
R T
Y O
F W
O O
D A
R D
C
U R
R A
N
IN
C A
N D
IT
S
C L
IE
N T
B
A
C
D
B
A
C
D
2 3 4 5 61
2 3 4 5 61
W
OO
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B Y:
D
AT
E D
ES
C
R
IP
TI
O
N R
EV D
R
AW
N
B Y:
JOB NO.:
SCALE:
DATE:
SHEET: OF
1/8" = 1'-0"
M J
BP
H
M J
16621
MAY 5, 2017
H110.1
GR
OU
N D F
L O
OR
D
UC
TW
OR
K
PART 1B 90% DESIGN SUBMITTAL
210129
SCALE: 1/8" = 1'-0"
1 DUCTWORK - GROUND FLOOR
MUA-1
EF-1
ACCESS HATCH
16"x10"
16" X 10" DN
MECH ATTIC
M20G
UP
16"x10"
EF-2
EF-3
AHU-1
AHU-2
AHU-3
"x
18"x16"
"x
"x
22"x20"
14"x16"
20" x 16"
14" x 16"
16" x 16"
20" x 18"
18"x18"
SIZE 6/12
.433 IN STATIC
12"ø 14"ø 18"ø 20"x12"
18"x12"
6"ø
S10
R10
STAIR
M00STD
W
OO
DA
RD
CU
RR
AN
U
N H
P R
O
JE
C T
ID
-0
W
AT
ER
T R
EA
TM
EN
T
PL
AN
T R
EP
LA
C
EM
EN
T
U N
IV
ER
SI
TY
O F
N
EW
H
AM
PS
H
IR
E
D U
R H
AM
, N
EW
H
AM
PS
H
IR
E
R E
P R
O D
U C
T
IO
N O
R M
O D
IF
IC
A T
IO
N
W
IT
H O
U T
W R
IT
T
E N
P E
R M
IS
S
IO
N
IS
P
R O
H
IB
IT
E
D
T H
IS
D
O C
U M
E N
T
IS
T H
E P
R O
P E
R T
Y O
F W
O O
D A
R D
C
U R
R A
N
IN
C A
N D
IT
S
C L
IE
N T
B
A
C
D
B
A
C
D
2 3 4 5 61
2 3 4 5 61
W
OO
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B Y:
D
AT
E D
ES
C
R
IP
TI
O
N R
EV D
R
AW
N
B Y:
JOB NO.:
SCALE:
DATE:
SHEET: OF
1/4" = 1'-0"
M J
BP
H
M J
16621
MAY 5, 2017
H110.2
D U
CT
W
OR
K
- P
A R T
P L
AN
S
PART 1B 90% DESIGN SUBMITTAL
210130
SCALE: 1/4" = 1'-0"
1 DUCTWORK - ATTIC
SCALE: 1/4" = 1'-0"
2 DUCTWORK - TRAINING LAB MEZZ.
W
UP
REF.
TSTS
TS
TS
TS TS
TS
TS
A
D
B C
DN
UP
UP
SEE TRAINING LAB MEZZ.
FLOOR PLAN FOR CONTINUATION
B-1 B-2
UH-1 UH-2
CUH-01
CUH-02
CUH-03
EU-1
RS & RL
UH
LABORATORY
LAB STO
106A
DRY STO
IT ROOM
RECORDS
106B
WOMENS TOILET
MENS TOILET
CONFERENCE ROOM
CORRIDOR
100CRA
VEST
100VSA
MECH ROOM
120G
ELEC ROOM
120E
BREAK ROOM
STAFF OFFICE
UNISEX CHANGING
UNISEX CHANGING
TOILET
LAB STO
130A
TRAINING LAB
JAN
1 1/4"
1 1/4"
MP-40-80
MP-30-80
GAS FIRED UH
GAS FIRED UH
RS & RL
1" 1"
MP-30-80
MP-30-80
MP-40-80
MP-40-80
MP-40-80
TO CUH-02
TO CUH-03
TO CUH-01
TO VAV-10
TO UH-2
TO UH-1
TO EU-1
PUMPS
EX-1
AS-1
CU-1 CU-2 CU-3
W
OO
DA
RD
CU
RR
AN
U
N H
P R
O
JE
C T
ID
-0
W
AT
ER
T R
EA
TM
EN
T
PL
AN
T R
EP
LA
C
EM
EN
T
U N
IV
ER
SI
TY
O F
N
EW
H
AM
PS
H
IR
E
D U
R H
AM
, N
EW
H
AM
PS
H
IR
E
R E
P R
O D
U C
T
IO
N O
R M
O D
IF
IC
A T
IO
N
W
IT
H O
U T
W R
IT
T
E N
P E
R M
IS
S
IO
N
IS
P
R O
H
IB
IT
E
D
T H
IS
D
O C
U M
E N
T
IS
T H
E P
R O
P E
R T
Y O
F W
O O
D A
R D
C
U R
R A
N
IN
C A
N D
IT
S
C L
IE
N T
B
A
C
D
B
A
C
D
2 3 4 5 61
2 3 4 5 61
W
OO
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B Y:
D
AT
E D
ES
C
R
IP
TI
O
N R
EV D
R
AW
N
B Y:
JOB NO.:
SCALE:
DATE:
SHEET: OF
1/8" = 1'-0"
M J
BP
H
M J
16621
MAY 5, 2017
H120.1
GR
OU
ND
F
LO
O R
P
IP
IN
G
PART 1B 90% DESIGN SUBMITTAL
210131
1 PIPING - GROUND FLOOR
MUA-1
AHU-1
AHU-2
AHU-3
HWS & R
RS & RL
HWS & R
RS & RL
RS & RL
HWS & R
DN TO FT
DN
DN
DN
(TYP.)
RS & RL
W
OO
DA
RD
CU
RR
AN
U
N H
P R
O
JE
C T
ID
-0
W
AT
ER
T R
EA
TM
EN
T
PL
AN
T R
EP
LA
C
EM
EN
T
U N
IV
ER
SI
TY
O F
N
EW
H
AM
PS
H
IR
E
D U
R H
AM
, N
EW
H
AM
PS
H
IR
E
R E
P R
O D
U C
T
IO
N O
R M
O D
IF
IC
A T
IO
N
W
IT
H O
U T
W R
IT
T
E N
P E
R M
IS
S
IO
N
IS
P
R O
H
IB
IT
E
D
T H
IS
D
O C
U M
E N
T
IS
T H
E P
R O
P E
R T
Y O
F W
O O
D A
R D
C
U R
R A
N
IN
C A
N D
IT
S
C L
IE
N T
B
A
C
D
B
A
C
D
2 3 4 5 61
2 3 4 5 61
W
OO
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B Y:
D
AT
E D
ES
C
R
IP
TI
O
N R
EV D
R
AW
N
B Y:
JOB NO.:
SCALE:
DATE:
SHEET: OF
1/4" = 1'-0"
M J
BP
H
M J
16621
MAY 5, 2017
H120.2
PI
P I
NG
P
AR
T
PL
A N
S
PART 1B 90% DESIGN SUBMITTAL
210132
SCALE: 1/4" = 1'-0"
1 PIPING - ATTIC
SCALE: 1/4" = 1'-0"
2 PIPING - TRAINING LAB MEZZ.
PROBE-TYPE
LWCO
EX
PA
N
SI
O
TA
K
-E T-
1"
LOCKABLE VALVE
3/4"
2-1/2" HOT WATER SUPPLY
TO P-1 & P-2
COLD WATER
MAKEUP (SEE
PLUMBING)
1" FAST FILL
VIBRATION ISOLATOR
AUTOMATIC AIR VENT.
PIPE 3/8" TO FLOOR
DRAIN WITH AIR GAP.
AI
SE
PA
R
AT
O
R
AS
-1
3/4"
ONE-SHOT CHEMICAL
FEEDER (SEE DETAIL)
CHECK VALVE
ACV
P-4
P-3
LINE SIZE ACV
FLOW MEASURING
BOILER B-1
BOILER B-2
AIR VENT
THERMOMETER
THERMOMETER
CHECK VALVE
PRV (60
PSI)
2"
2" 2"
2-1/2" HOT
WATER RETURN
CLOSE SPACE TEE
PRESSURE GAUGE
HOUSE KEEPING PAD
THERMOMETER
THERMOMETER
2"
2"
W
OO
DA
RD
CU
RR
AN
U
N H
P R
O
JE
C T
ID
-0
W
AT
ER
T R
EA
TM
EN
T
PL
AN
T R
EP
LA
C
EM
EN
T
U N
IV
ER
SI
TY
O F
N
EW
H
AM
PS
H
IR
E
D U
R H
AM
, N
EW
H
AM
PS
H
IR
E
R E
P R
O D
U C
T
IO
N O
R M
O D
IF
IC
A T
IO
N
W
IT
H O
U T
W R
IT
T
E N
P E
R M
IS
S
IO
N
IS
P
R O
H
IB
IT
E
D
T H
IS
D
O C
U M
E N
T
IS
T H
E P
R O
P E
R T
Y O
F W
O O
D A
R D
C
U R
R A
N
IN
C A
N D
IT
S
C L
IE
N T
B
A
C
D
B
A
C
D
2 3 4 5 61
2 3 4 5 61
W
OO
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B Y:
D
AT
E D
ES
C
R
IP
TI
O
N R
EV D
R
AW
N
B Y:
JOB NO.:
SCALE:
DATE:
SHEET: OF
1/4" = 1'-0"
M J
BP
H
M J
16621
MAY 5, 2017
H130.1
DE
TA
IL S
PART 1B 90% DESIGN SUBMITTAL
210133
NO SCALE
1 TYPICAL CONDENSING BOILER PIPING
PLUGGED TEE
FOR DRAIN
PITCH UP
PITCH UP
PITCH UP
PIPING FOR 1-ROW ELEMENT
PIPING FOR 2-ROW ELEMENT
PITCH UP
PITCH UP
2ND TIER OF
FINNED ELEMENT
WHERE APPLICABLE
1/2"
PITCH UP
1/2"
HWR MAIN,
(TYP.) HWS MAIN,
(TYP.)
AUTOMATIC CONTROL
VALVE (TYP.)
UP-FEED
DOWN-FEED
18"
4"
4 3/8"
2 1/16"
DAMPER
CONTROL
DEVICE
ENCLOSURE
LOUVER OPENING
ELEMENT
FIN TUBE SUPPORT
SUPPORT W/BALL
BEARING CRADELS
ADJUSTABLE
DAMPER
SECURING
SCREWS
WALL
FINISHED
FLOOR
5 5/16"
TYPE
TYPE
RETURN PIPE
AS REQUIRED PER
PLANS SUPPORT PIPE
AS RECOMMENDED
BY UNIT MFR.
FULL
BACKPLATE
A
B
ENCLOSURE
16 GAUGE STEEL
W
OO
DA
RD
CU
RR
AN
U
N H
P R
O
JE
C T
ID
-0
W
AT
ER
T R
EA
TM
EN
T
PL
AN
T R
EP
LA
C
EM
EN
T
U N
IV
ER
SI
TY
O F
N
EW
H
AM
PS
H
IR
E
D U
R H
AM
, N
EW
H
AM
PS
H
IR
E
R E
P R
O D
U C
T
IO
N O
R M
O D
IF
IC
A T
IO
N
W
IT
H O
U T
W R
IT
T
E N
P E
R M
IS
S
IO
N
IS
P
R O
H
IB
IT
E
D
T H
IS
D
O C
U M
E N
T
IS
T H
E P
R O
P E
R T
Y O
F W
O O
D A
R D
C
U R
R A
N
IN
C A
N D
IT
S
C L
IE
N T
B
A
C
D
B
A
C
D
2 3 4 5 61
2 3 4 5 61
W
OO
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B Y:
D
AT
E D
ES
C
R
IP
TI
O
N R
EV D
R
AW
N
B Y:
JOB NO.:
SCALE:
DATE:
SHEET: OF
1/8" = 1'-0"
M J
BP
H
M J
16621
MAY 5, 2017
H130.2
DE
TA
IL S
PART 1B 90% DESIGN SUBMITTAL
210134
NO SCALE
1 HOT WATER RADIATION
2 FINTUBE RADIATION-SINGLE ELEMENT WALL MOUNTED
DA
RD
CU
RR
AN
U
N H
P R
O
JE
C T
ID
-0
W
AT
ER
T R
EA
TM
EN
T
PL
AN
T R
EP
LA
C
EM
EN
T
U N
IV
ER
SI
TY
O F
N
EW
H
AM
PS
H
IR
E
D U
R H
AM
, N
EW
H
AM
PS
H
IR
E
R E
P R
O D
U C
T
IO
N O
R M
O D
IF
IC
A T
IO
N
W
IT
H O
U T
W R
IT
T
E N
P E
R M
IS
S
IO
N
IS
P
R O
H
IB
IT
E
D
T H
IS
D
O C
U M
E N
T
IS
T H
E P
R O
P E
R T
Y O
F W
O O
D A
R D
C
U R
R A
N
IN
C A
N D
IT
S
C L
IE
N T
B
A
C
D
B
A
C
D
2 3 4 5 61
2 3 4 5 61
W
OO
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B Y:
D
AT
E D
ES
C
R
IP
TI
O
N R
EV D
R
AW
N
B Y:
JOB NO.:
SCALE:
DATE:
SHEET: OF
M J
BP
H
M J
16621
MAY 5, 2017
H140.1
SC
H E
DU
LE
S
PART 1B 90% DESIGN SUBMITTAL
210135
REGISTERS, GRILLES & DIFFUSERS SCHEDULE
TAG MANUFACTURER MODEL TYPE
NECK
SIZE (IN)
DIRECTION
OF BLOW MAX NC MAX SP DAMPER BORDER NOTES
E1 PRICE 80 SERIES GRID CORE 6 x 6 N/A 20 0.09 in-wg NONE SURFACE
MOUNT
E2 PRICE 80 SERIES GRID CORE 8 x 8 N/A 20 0.09 in-wg NONE SURFACE
MOUNT
E5 PRICE 80 SERIES GRID CORE 12 x 12 N/A 20 0.09 in-wg NONE SURFACE
MOUNT
E6 PRICE 80 SERIES GRID CORE 14 x 14 N/A 20 0.09 in-wg NONE SURFACE
MOUNT
R2 PRICE 80 SERIES GRID CORE 8 x 8 N/A 20 0.09 in-wg NONE SURFACE
MOUNT
R3 PRICE 80 SERIES GRID CORE 10 x 10 N/A 20 0.00 in-wg NONE SURFACE
MOUNT
R5 PRICE 80 SERIES GRID CORE 12 x 12 N/A 20 0.09 in-wg NONE SURFACE
MOUNT
R7 PRICE 80 SERIES GRID CORE 16 x 16 N/A 20 0.09 in-wg NONE SURFACE
MOUNT
R10 PRICE 22 WALL GRILLE 36" x 20" SEE PLANS 35 0.15 in-wg NONE SURFACE
MOUNT
S3 PRICE SMD SERIES CEILING
DIFFUSER
12 x 12 4-WAY 23 0.11 in-wg NONE SURFACE
MOUNT
S5 PRICE SMD SERIES CEILING
DIFFUSER
18 x 18 4-WAY 23 0.10 in-wg NONE SURFACE
MOUNT
S10 PRICE HCD DRUM
LOUVER
6" X 12" N/A 20 0.09 in-wg NONE SURFACE
MOUNT
FCVENT PIPING ABOVE FINISHED FLOORV
SANITARY PIPING BELOW FINISHED FLOOR
LEGEND
CHECK VALVE
EWC-X ELECTRIC WATER COOLER
SA "X"
VTR
SHOCK ARRESTOR (P.D.I RATING)
VENT THROUGH ROOF
SHUT-OFF VALVE
CAP
DN DOWN
AFF ABOVE FINISHED FLOOR
BFF BELOW FINISHED FLOOR
TYP. TYPICAL
TRANSITION
CIRCULATING PUMP
THERMOMETER
AP ACCESS PANEL
DCP-X DOMESTIC CIRCULATING PUMP
EEWS-X EMERGENCY EYEWASH & SHOWER
ET-X EXPANSION TANK
FD-X FLOOR DRAIN
FS-X FLOOR SINK
HB-X HOSE BIBB
L-X LAVATORY
MB-X MOP BASIN
SK-X SINK
SH-X SHOWER
UR-X URINAL
WC-X WATER CLOSET
WH-X WALL HYDRANT
FCO FLOOR CLEANOUT
SANITARY PIPING ABOVE FINISHED FLOORS
STORM DRAIN PIPING ABOVE FINISHED FLOORSD
COLD WATER PIPING ABOVE FINISHED FLOORCW
HOT WATER PIPING ABOVE FINISHED FLOORHW
HOT WATER RETURN PIPING ABOVE FINISHED FLOORHWR
VENT PIPING BELOW FINISHED FLOOR
STORM DRAIN PIPING BELOW FINISHED FLOOR
S
V
SD
FREEZE PROOF WALL HYDRANT
FLOOR CLEANOUT
FLOOR DRAIN
PIPE DROP
PIPE RISE
THERMOSTATIC FLOW CONTROL
LSK-X LABORATORY SINK
W
OO
DA
RD
CU
RR
AN
U
N H
P R
O
JE
C T
ID
-0
W
AT
ER
T R
EA
TM
EN
T
PL
AN
T R
EP
LA
C
EM
EN
T
U N
IV
ER
SI
TY
O F
N
EW
H
AM
PS
H
IR
E
D U
R H
AM
, N
EW
H
AM
PS
H
IR
E
R E
P R
O D
U C
T
IO
N O
R M
O D
IF
IC
A T
IO
N
W
IT
H O
U T
W R
IT
T
E N
P E
R M
IS
S
IO
N
IS
P
R O
H
IB
IT
E
D
T H
IS
D
O C
U M
E N
T
IS
T H
E P
R O
P E
R T
Y O
F W
O O
D A
R D
C
U R
R A
N
IN
C A
N D
IT
S
C L
IE
N T
B
A
C
D
B
A
C
D
2 3 4 5 61
2 3 4 5 61
W
OO
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
C H
E C
K E
D B
Y:
D
E S
IG
N
E D
B Y:
D A
TE
D
E S
C R
IP
TI
O N
R E
V
D R
A W
N B
Y:
JOB NO.:
SCALE:
DATE:
SHEET: OF
1/8" = 1'-0"
R O
M
M
AM
C G
16621
MAY 5, 2017
P100.1
L E
GE
N D , G
EN
ER
AL
N
OT
E S
PART 1B 90% DESIGN SUBMITTAL
210136
GENERAL NOTES
1 DRAWINGS ARE DIAGRAMMATIC ONLY AND REPRESENT THE GENERAL SCOPE OF THE WORK.
REVIEW THE GENERAL NOTES, SPECIFICATIONS AND PLANS FOR ADDITIONAL REQUIREMENTS
THAT MAY NOT BE SPECIFICALLY CALLED OUT IN THIS PORTION OF THE CONSTRUCTION
DOCUMENTS. NOTIFY THE ARCHITECT OF ANY CONFLICTS OR
DISCREPANCIES PRIOR TO SUBMISSION OF BID.
2 VERIFY LOCATION AND DEPTH OF UTILITIES AT ALL POINTS OF CONNECTION INDICATED ON
DRAWINGS BEFORE START OF PROJECT.
3 COORDINATE ALL WORK WITH OTHER TRADES AND CONTRACTORS. COORDINATE PIPING
INSTALLATION WITH STRUCTURAL GRADE BEAMS, FOOTINGS, COLUMN PIERS, ETC. SLEEVE
PIPING THROUGH GRADE BEAMS, FOOTING, ETC. WHERE REQUIRED AND AS NOTED ON
PLANS. COORDINATE SLEEVE INSTALLATIONS WITH THE ARCHITECT, STRUCTURAL ENGINEER,
STRUCTURAL CONTRACTOR AND GENERAL CONTRACTOR BEFORE CONCRETE IS INSTALLED.
PIPING INVERTS AND SLOPE SHALL BE CLOSELY COORDINATED TO AVOID CONFLICTS WITH
ALL OTHER TRADES BELOW SLAB WORK.
4 COORDINATE PIPE ROUTING AWAY FROM ELECTRICAL PANELS. DO NOT ROUTE PIPING OVER
ELECTRICAL PANELS.
5 PIPING IN FINISHED AREAS SHALL BE ROUTED CONCEALED; EXPOSED PIPING, WHERE
NECESSARY, SHALL BE ROUTED AS HIGH AS POSSIBLE AND TIGHT TO WALLS.
6 REFER TO INSTALLATION SCHEDULE DATA FOR THE SIZE OF PIPING CONNECTIONS AND
MOUNTING HEIGHTS OF EACH FIXTURE.
7 ALL PLUMBING FIXTURE SHUT-OFF AND/OR BALANCING VALVES INSTALLED IN PIPE CHASES
SHALL BE ACCESSIBLE FROM JUST ABOVE THE CEILING LINE OR ACCESS DOORS PROVIDED
LOW IN CHASE WALL.
8 SANITARY WASTE PIPING 4" & LARGER SHALL BE INSTALLED WITH A PITCH OF 1/4" PER 1'-0".
9 ALL UNDERSLAB PIPING SHALL BE INSTALLED TO PROVIDE NO LESS THAN 2" OF COVER
BETWEEN THE PIPING AND THE FLOOR SLAB.
10 VENT AND WATER PIPING SHALL PITCH TO DRAIN.
11 PROVIDE FIXTURE STOPS ON ANY WATER SUPPLY IMMEDIATELY ADJACENT TO PLUMBING
FIXTURES.
12 CLEAN FAUCET AERATORS AND PIPE STRAINERS PRIOR TO TURNING BUILDING OVER TO THE
OWNER.
13 PROVIDE TRAP PRIMERS WHERE REQUIRED BY LOCAL AUTHORITIES.
14 VALVES SHALL BE LINE SIZE UNLESS OTHERWISE NOTED.
15 STORM DRAIN PIPING SHALL BE INSTALLED WITH A PITCH OF 1/8" PER 1'-0".
16 THE TERM "PROVIDE" SHALL MEAN "TO FURNISH, INSTALL AND CONNECT COMPLETELY".
17 ENTIRE PLUMBING INSTALLATION SHALL BE IN COMPLIANCE WITH ALL CURRENT LOCAL, STATE
AND FEDERAL
CODES AND STANDARDS.
18 OSHA RULES, REGULATIONS AND REQUIREMENTS, AND ANY STATE AND LOCAL
REQUIREMENTS FOR SAFETY SHALL BE FOLLOWED BY THE CONTRACTOR
19 FINISHED FLOOR ELEVATION 62.0'
W
UP
REF.
A
D
B C
LABORATORY
LAB STO
130A
CONFERENCE ROOM
CONTROL ROOM
120B
BREAK ROOM
UNISEX
CHANGING
UNISEX
CHANGING
JAN
TRAINING LAB
IT ROOM
STAFF OFFICE
DRY STO
SUPERVISOR
MENS TOILET
WOMENS TOILET
LAB STO
106A
TRAINING VEST
VS102
ELEC ROOM
120E
MECH ROOM
120G
CHEMICAL STORAGE
120A
CORRIDOR
100CRA
WATER TREATMENT
RECORDS
106B
TOILET
WC-1
FCO
SH-1 SH-2
FCO
S-
S- 2"
S- 4"
EWC-1
MB-1
WC-1
WC-2
L-1 L-1
UR-1 WC-1
FCO
4" S UP
2" W UP
2" V UP
2" W UP
2" V UP
2" W UP
2" W UP
2" V UP
S- 4"
2" W UP
2" W UP
2" W UP
4" S UP
4" S INV EL. 52.54'
SEE CIVIL DRAWINGS
FOR CONTINUATION
EEWS-1
SK-1
EEWS-1
2" V UP
2" W UP
S-
S- 2" V- 2"
2" W UP
SEE ISLAND
VENT DETAIL
2" V UP
EEWS-2
EEWS-2
EEWS-2
EEWS-2
FD-1
FS-1
4" S UP
2" V UP
FCO
S- 4"
S-
S- 4"S- 4"
FCO
S-
S-
4" S UP
2" V UP
FCO
4" S UP
2" W UP
2" V UP
FD-2
FD-2
FD-3
3" W UP
2" V UP
L-1
S- 4"
FD-3
2" V UP
3" S UP
S-
6" SD UP
6" SD UP
2" V UP
2" W UP
SD- 6"
1/4" / 12"
1/ 4"
2" W UP
1/4" / 12"
S- 4"
2" W UP
1/ 4"
1/4" / 12"
1/4" / 12"
INV. EL 60.30'
S-
2" V UP
4" S UP
FCO
FS-1
LSK-2
LSK-3
LSK-1
LSK-1
LSK-2
FCO
SD- 6"
1/8" / 12"
8" SD INV EL. 58.00'
10460 SQ. FT
SEE CIVIL DRAWINGS
FOR CONTINUATION
8" SD DN
FCO
MAINTENANCE AREA
W
OO
DA
RD
CU
RR
AN
U
N H
P R
O
JE
C T
ID
-0
W
AT
ER
T R
EA
TM
EN
T
PL
AN
T R
EP
LA
C
EM
EN
T
U N
IV
ER
SI
TY
O F
N
EW
H
AM
PS
H
IR
E
D U
R H
AM
, N
EW
H
AM
PS
H
IR
E
R E
P R
O D
U C
T
IO
N O
R M
O D
IF
IC
A T
IO
N
W
IT
H O
U T
W R
IT
T
E N
P E
R M
IS
S
IO
N
IS
P
R O
H
IB
IT
E
D
T H
IS
D
O C
U M
E N
T
IS
T H
E P
R O
P E
R T
Y O
F W
O O
D A
R D
C
U R
R A
N
IN
C A
N D
IT
S
C L
IE
N T
B
A
C
D
B
A
C
D
2 3 4 5 61
2 3 4 5 61
W
OO
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
C H
E C
K E
D B
Y:
D
E S
IG
N
E D
B Y:
D A
TE
D
E S
C R
IP
TI
O N
R E
V
D R
A W
N B
Y:
JOB NO.:
SCALE:
DATE:
SHEET: OF
1/8" = 1'-0"
R O
M
M
AM
C G
16621
MAY 5, 2017
P110.1
BE
LO
W S
L A B
D R
AI
N A
GE
PART 1B 90% DESIGN SUBMITTAL
210137
SCALE: 1/8" = 1'-0"
1 BELOW SLAB DRAINAGE
2 BELOW SLAB DRAINAGE MAINTENANCE AREA
W
UP
REF.
A
D
B C
LABORATORY
LAB STO
130A
CONFERENCE ROOM
CONTROL ROOM
120B
BREAK ROOM
UNISEX
CHANGING
UNISEX
CHANGING
JAN
TRAINING LAB
IT ROOM
STAFF OFFICE
DRY STO
SUPERVISOR
MENS TOILET
104WOMENS TOILET
LAB STO
106A
TRAINING VEST
VS102
ELEC ROOM
120EMECH ROOM
120G
CHEMICAL STORAGE
120A
CORRIDOR
100CRA
WATER TREATMENT
RECORDS
106B
TOILET
SK-1
EWC-1
MB-1
WC-1 WC-2 L-1 L-1 UR-1 WC-1
EEWS-1
WC-1
SH-1 SH-2
EEWS-1
OB-1
FCO
FCO
4" S DN
2" W IN CHASE
1-1/2" V DN
2" V DN
2" W DN
2" W &
1-1/2" V DN
2" W DN
2" V DN
2" W DN
2" V DN
4" S DN
2" W IN CHASE
1-1/2" V DN
FCO2" W &
1-1/2" V DN
4" S DN
2" V DN
2" V ABOVE
4" S IN CHASE
2" V DN
2" V DN
2" V ABOVE
4" S IN CHASE
2" V DN
V- 2"
V-
V- 2"
6" SD DN
PROVIDE CO 18" AFF
2" W &
1-1/2" V DN
LSK-2
LSK-1
LSK-1
LSK-32" W DN
2" ISLAND
VENT DN
6" SD DN
PROVIDE CO
18" AFF
2" W &
1-1/2" V DN
6" SD UP
1-1/2" W FROM BFP
TO FLOOR SINK
3/4" W TO
FLOOR SINK
EEWS-2
EEWS-2
EEWS-2
EEWS-2
FD-1
2" W IN CHASE
1-1/2" V DN
L-1
LSK-2
2" V DN
2" W &
1-1/2" V DN
2" V DN
OFFSET 2" V
UNDER MEZZANINE
2" V UP IN ATTIC
3" VTR
FCO
FS-1
V- 2"
4" S DN
2" V DN
FCO2" V UP TO
ATTIC 3" VTR
V- 3"
V- 3"V- 2"
FD-3
FD-3
2" V DN
2" W &
1-1/2" V DN
2" V DN
3" V UP
4" VTR
2" PUMPED
WASTE DN
2" W DN
FCO
MAINTENANCE AREA
SP-1
SUMP PUMP
IN PIT
2'x2'x2' PIT
2" PUMPED WASTE UP
W
OO
DA
RD
CU
RR
AN
U
N H
P R
O
JE
C T
ID
-0
W
AT
ER
T R
EA
TM
EN
T
PL
AN
T R
EP
LA
C
EM
EN
T
U N
IV
ER
SI
TY
O F
N
EW
H
AM
PS
H
IR
E
D U
R H
AM
, N
EW
H
AM
PS
H
IR
E
R E
P R
O D
U C
T
IO
N O
R M
O D
IF
IC
A T
IO
N
W
IT
H O
U T
W R
IT
T
E N
P E
R M
IS
S
IO
N
IS
P
R O
H
IB
IT
E
D
T H
IS
D
O C
U M
E N
T
IS
T H
E P
R O
P E
R T
Y O
F W
O O
D A
R D
C
U R
R A
N
IN
C A
N D
IT
S
C L
IE
N T
B
A
C
D
B
A
C
D
2 3 4 5 61
2 3 4 5 61
W
OO
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
C H
E C
K E
D B
Y:
D
E S
IG
N
E D
B Y:
D A
TE
D
E S
C R
IP
TI
O N
R E
V
D R
A W
N B
Y:
JOB NO.:
SCALE:
DATE:
SHEET: OF
1/8" = 1'-0"
R O
M
M
AM
C G
16621
MAY 5, 2017
P110.2
FI
R S
T
FL
OO
R
PL
A N
D R A
IN
A G
E
PART 1B 90% DESIGN SUBMITTAL
210138
SCALE: 1/8" = 1'-0"
2 FIRST FLOOR DRAINAGE
SCALE: 1/8" = 1'-0"
1 FIRST FLOOR DRAINAGE MAINTENANCE AREA
3 LOWER LEVEL DRAINAGE
A
D
B C
RD-1
7222 SF
6" SD DN
4" VTR
6" SD DN
RD-1
3239 SF
3" VTR
3" VTR
W
OO
DA
RD
CU
RR
AN
U
N H
P R
O
JE
C T
ID
-0
W
AT
ER
T R
EA
TM
EN
T
PL
AN
T R
EP
LA
C
EM
EN
T
U N
IV
ER
SI
TY
O F
N
EW
H
AM
PS
H
IR
E
D U
R H
AM
, N
EW
H
AM
PS
H
IR
E
R E
P R
O D
U C
T
IO
N O
R M
O D
IF
IC
A T
IO
N
W
IT
H O
U T
W R
IT
T
E N
P E
R M
IS
S
IO
N
IS
P
R O
H
IB
IT
E
D
T H
IS
D
O C
U M
E N
T
IS
T H
E P
R O
P E
R T
Y O
F W
O O
D A
R D
C
U R
R A
N
IN
C A
N D
IT
S
C L
IE
N T
B
A
C
D
B
A
C
D
2 3 4 5 61
2 3 4 5 61
W
OO
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
C H
E C
K E
D B
Y:
D
E S
IG
N
E D
B Y:
D A
TE
D
E S
C R
IP
TI
O N
R E
V
D R
A W
N B
Y:
JOB NO.:
SCALE:
DATE:
SHEET: OF
1/8" = 1'-0"
R O
M
M
AM
C G
16621
MAY 5, 2017
P110.3
RO
O F
P L A
N
PART 1B 90% DESIGN SUBMITTAL
210139
1 ROOF PLAN
W
UP
REF.
FCFC
A
D
B C
LABORATORY
LAB STO
130A
CONFERENCE ROOM
CONTROL ROOM
120B
BREAK ROOM
UNISEX CHANGING
122UNISEX CHANGING
JAN
VEST
100VSA
TRAINING LAB
IT ROOM
STAFF OFFICE
DRY STO
SUPERVISOR
MENS TOILET
WOMENS TOILET
MAINTENANCE AREA
LAB STO
106A
TRAINING VEST
VS102 ELEC ROOM
120E
MECH ROOM
120G
CHEMICAL STORAGE
120A
CORRIDOR
100CRA
WATER TREATMENT
RECORDS
106B
TOILET
CW- 1 1/2"
HWR- 1/2"
HW- 1"
WC-1
SH-1 SH-2
EWC-1
SK-1
MB-1
WC-1 WC-2 L-1 L-1 UR-1 WC-1
OB-1
EEWS-1
EEWS-1
1" 80° HW DN
1/2" HW &
1-1/2" CW DN
1/2" HW &
CW DN
1/2" HW &
CW DN
1/2" CW DN 1/2" HW &
CW DN
2" CW DN
1/2" HW DN
1/2" HW &
2" CW DN
L-1
LSK-1
LSK-2
LSK-3
LSK-1
CW- 2"
HWR- 1/2"
HW- 1"
C W
- 2
H W
R
- 1
/2
H W
- 1
/4
LF-1
LF-1
LF-1
L-2
(TYP OF 6)
SA-"B"
SA-"B"
AD
AD
CW- 1"CW- 1"
C W
- 3 /4
C W
- 3 /4
C W
- 3 /4
C W
- 3 /4
C W
- 3 /4
WH-1
85° HWR- 1/2"
85° HW- 1 1/2"
85° HWR- 1/2"
85° HW- 1 1/2"
° H
W R
- 1 /2
° H W
- 1
/2
C W
- 1
2" CW DN TO 36" AFF
PROVIDE ISOLATION
VALVE FOR EQUIPMENT
CONNECTION
2" CW DN TO 36" AFF
PROVIDE ISOLATION
VALVE FOR EQUIPMENT
CONNECTION
2" CW DN TO 36" AFF
PROVIDE ISOLATION
VALVE FOR EQUIPMENT
CONNECTION
3/4" CW DN TO
HOSE REEL
3/4" CW DN TO
HOSE REEL
3/4" CW DN TO
HOSE REEL
3/4" CW DN TO
HOSE REEL
3/4" CW DN TO
HOSE REEL
HWR- 1/2"
HW- 1/2"
CW- 1/2"
85° HWR- 1/2"
85° HW- 1 1/2"
HWR- 1/2"
CW- 1/2"
HW- 1/2"
1/2" HW &
CW DN
1" 80° HW DN
1" 80° HW DN
1" 80° HW DN
1-1/4" 80° HW DN
85° HW- 1 1/2"
85° HWR- 1/2"
HW- 1"
CW- 2"
EEWS-2
EEWS-2
EEWS-2
EEWS-2
3/4" CW DN
1" CW DN TO 36" AFF
PROVIDE ISOLATION
VALVE FOR FUTURE USE
3/4" CW DN TO
HOSE REEL
2" CW DN TO 36" AFF
PROVIDE ISOLATION
VALVE FOR METER TESTING
2" CW DN BELOW
MEZZANINE WALKWAY
CW- 2"
1/2" HW &
CW DN
4" CW SEE CIVIL
FOR CONTINUATION
WM-1
BFP-1
BFP-2
BFP-3
BFP-4
BFP-5
TV-1
DCP-1
ET-1
TV-2
DCP-2
WHTR-1
LF-1
LSK-2
1/2" HW &
CW DN
1/2" HW DN
1/2" HW &
CW DN
G
- 3
GAS DN SEE CIVIL
FOR CONTINUATION
C W
- 2
1" CW UNDERGROUND TO
OYSTER RIVER PUMP HOUSE
SEE DRAWING P320.1 FOR
PUMP HOUSE PLAN
3/4" CW DN
WH-1
1-1/4" 80° HW DN
85° HW- 1"
3/4" HW DN TO
HOSE REEL
G
- 1
/4
G- 1 1/4" G- 1 1/2"
G- 1"
2" CW
1" HW
1-1/2" 85° HW
1/2" 85° HWR
2" CW &
2" G
1" G DN WITH VALVE,
UNION & DIRT LEG
1" G DN WITH VALVE,
UNION & DIRT LEG
1" G DN WITH VALVE,
UNION & DIRT LEG
1" G DN WITH VALVE,
UNION & DIRT LEG
1" G DN WITH VALVE,
UNION & DIRT LEG
FLOW SWITCH TYPICAL
FOR EACH EYEWASH
FSW-1
FSW-1
FSW-1
FSW-1
FSW-1
MAINTENANCE AREA
3/4" CW DN
WH-1
G
- 1
/2
G- 1/2"
1/2" G DN WITH VALVE,
UNION & DIRT LEG
1/2" G DN WITH VALVE,
UNION & DIRT LEG
W
OO
DA
RD
CU
RR
AN
U
N H
P R
O
JE
C T
ID
-0
W
AT
ER
T R
EA
TM
EN
T
PL
AN
T R
EP
LA
C
EM
EN
T
U N
IV
ER
SI
TY
O F
N
EW
H
AM
PS
H
IR
E
D U
R H
AM
, N
EW
H
AM
PS
H
IR
E
R E
P R
O D
U C
T
IO
N O
R M
O D
IF
IC
A T
IO
N
W
IT
H O
U T
W R
IT
T
E N
P E
R M
IS
S
IO
N
IS
P
R O
H
IB
IT
E
D
T H
IS
D
O C
U M
E N
T
IS
T H
E P
R O
P E
R T
Y O
F W
O O
D A
R D
C
U R
R A
N
IN
C A
N D
IT
S
C L
IE
N T
B
A
C
D
B
A
C
D
2 3 4 5 61
2 3 4 5 61
W
OO
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
C H
E C
K E
D B
Y:
D
E S
IG
N
E D
B Y:
D A
TE
D
E S
C R
IP
TI
O N
R E
V
D R
A W
N B
Y:
JOB NO.:
SCALE:
DATE:
SHEET: OF
1/8" = 1'-0"
R O
M
M
AM
C G
16621
MAY 5, 2017
P120.1
FI
RS
T F L
OO
R
PL
AN
S
UP
PL
Y
PART 1B 90% DESIGN SUBMITTAL
210140
SCALE: 1/8" = 1'-0"
1 FIRST FLOOR SUPPLY
2 FIRST FLOOR SUPPLY MAINTENANCE AREA
12"
18"
23"
"70
"78
SPRAY
HANDLE
SLIDE
BAR
SHOWERHEAD
SHOWER
VALVE
SHOWER
ENTRANCE
60" FLEXIBLE
HOSE
WATER SUPPLY
CONNECTION TO
SPRAY HOSE
SHOWER BASE
RELOCATE GRAB BARS
IN SHOWERS TO 34" AFF
DIVERTER
18"
ROOF DRAIN FURNISHED
AND INSTALLED BY
PLUMBING CONTRACTOR
TYPICAL COUPLING
CONNECTOR STORM DRAIN
PIPING
INSULATION
INSTALL HANGER
WITHIN 18" OF THE ELBOW
LAB SINK
CABINET
2" W IN
CABINET
RUN 2" V AS HIGH AS
POSSIBLE IN CABINET
PROVIDE
CLEANOUT 18" AFF
CONNECT 2" VENT
TO 2" WASTE
BELOW FLOOR
2" V BELOW
FLOOR PITCH
BACK TO 2" W
2" V UP IN WALL
PROVIDE WCO
18" AFF
CONNECT 2" V TO
VENT SYSTEM
ABOVE FLOOR
CONTINUE 2" W TO
SANITARY MAIN
FINISHED
FLOOR
UNION
(TYP)
ET-1
HI/LOW MIXING
VALVE. SET TO
DELIVER 120°F
1" CW
120° 1-1/4" HW
2" CW
FINISHED FLOOR
1-1/4" BALL VALVE
TEST CONNECTION
WITH THREADED
HOSE CONNECTION
3/4" CW
120° 1/2" HWR
3" BOILER HWS
SEE MECHANICAL DRAWINGS
FOR CONTINUATION
3" BOILER HWR
SEE MECHANICAL DRAWINGS
FOR CONTINUATION
THERMOMETER PROVIDED WITH
TURBOMAX WATER HEATER
(TYP)
2" DOMESTIC COLD WATER
CONNECTION
2" BOILER RETURN
WATER CONNECTION
SEE MECHANICAL DRAWINGS
FOR CONTINUATION
DRAIN (TYP)
85° 1/2" HWR 1" CW
1-1/2" HW
80° 1-1/2" HW
AQUASTAT
NOTE:
85° HW AQUASTAT TO BE LOCATED
IN CHEMICAL STORAGE AREA
W
OO
DA
RD
CU
RR
AN
U
N H
P R
O
JE
C T
ID
-0
W
AT
ER
T R
EA
TM
EN
T
PL
AN
T R
EP
LA
C
EM
EN
T
U N
IV
ER
SI
TY
O F
N
EW
H
AM
PS
H
IR
E
D U
R H
AM
, N
EW
H
AM
PS
H
IR
E
R E
P R
O D
U C
T
IO
N O
R M
O D
IF
IC
A T
IO
N
W
IT
H O
U T
W R
IT
T
E N
P E
R M
IS
S
IO
N
IS
P
R O
H
IB
IT
E
D
T H
IS
D
O C
U M
E N
T
IS
T H
E P
R O
P E
R T
Y O
F W
O O
D A
R D
C
U R
R A
N
IN
C A
N D
IT
S
C L
IE
N T
B
A
C
D
B
A
C
D
2 3 4 5 61
2 3 4 5 61
W
OO
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
C H
E C
K E
D B
Y:
D
E S
IG
N
E D
B Y:
D A
TE
D
E S
C R
IP
TI
O N
R E
V
D R
A W
N B
Y:
JOB NO.:
SCALE:
DATE:
SHEET: OF
As indicated
R O
M
M
AM
C G
16621
MAY 5, 2017
P130.1
DE
TA
IL S
PART 1B 90% DESIGN SUBMITTAL
210141
NO SCALE
2 ADA SHOWER
NO SCALE
3 ROOF DRAIN
NO SCALE
5 ISLAND VENT DETAIL
1 WATER HEATER PIPING DETAIL
DA
RD
CU
RR
AN
U
N H
P R
O
JE
C T
ID
-0
W
AT
ER
T R
EA
TM
EN
T
PL
AN
T R
EP
LA
C
EM
EN
T
U N
IV
ER
SI
TY
O F
N
EW
H
AM
PS
H
IR
E
D U
R H
AM
, N
EW
H
AM
PS
H
IR
E
R E
P R
O D
U C
T
IO
N O
R M
O D
IF
IC
A T
IO
N
W
IT
H O
U T
W R
IT
T
E N
P E
R M
IS
S
IO
N
IS
P
R O
H
IB
IT
E
D
T H
IS
D
O C
U M
E N
T
IS
T H
E P
R O
P E
R T
Y O
F W
O O
D A
R D
C
U R
R A
N
IN
C A
N D
IT
S
C L
IE
N T
B
A
C
D
B
A
C
D
2 3 4 5 61
2 3 4 5 61
W
OO
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
C H
E C
K E
D B
Y:
D
E S
IG
N
E D
B Y:
D A
TE
D
E S
C R
IP
TI
O N
R E
V
D R
A W
N B
Y:
JOB NO.:
SCALE:
DATE:
SHEET: OF
R O
M
M
AM
C G
16621
MAY 5, 2017
P130.2
DE
TA
IL S
PART 1B 90% DESIGN SUBMITTAL
210142
SCALE:
1 DOMESTIC WATER ENTRANCE
SCALE:
TYPICAL LAB EMERGENCY EYE/FACE
WASH DETAIL2
SCALE:
4 WATER TREATMENT TEST FAUCETS
SCALE:
5 Hose Reel
SCALE:
TYPICAL CHEMICAL EMERGENCY
EYE/FACE WASH DETAIL3
DA
RD
CU
RR
AN
U
N H
P R
O
JE
C T
ID
-0
W
AT
ER
T R
EA
TM
EN
T
PL
AN
T R
EP
LA
C
EM
EN
T
U N
IV
ER
SI
TY
O F
N
EW
H
AM
PS
H
IR
E
D U
R H
AM
, N
EW
H
AM
PS
H
IR
E
R E
P R
O D
U C
T
IO
N O
R M
O D
IF
IC
A T
IO
N
W
IT
H O
U T
W R
IT
T
E N
P E
R M
IS
S
IO
N
IS
P
R O
H
IB
IT
E
D
T H
IS
D
O C
U M
E N
T
IS
T H
E P
R O
P E
R T
Y O
F W
O O
D A
R D
C
U R
R A
N
IN
C A
N D
IT
S
C L
IE
N T
B
A
C
D
B
A
C
D
2 3 4 5 61
2 3 4 5 61
W
OO
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
C H
E C
K E
D B
Y:
D
E S
IG
N
E D
B Y:
D A
TE
D
E S
C R
IP
TI
O N
R E
V
D R
A W
N B
Y:
JOB NO.:
SCALE:
DATE:
SHEET: OF
R O
M
M
AM
C G
16621
MAY 5, 2017
P140.1
SC
H E
DU
LE
S
PART 1B 90% DESIGN SUBMITTAL
210143
PLUMBING FIXTURE INSTALLATION SCHEDULE
FURNISHED & INSTALLED BY PLUMBING CONTRACTOR
TAG DESCRIPTION
BRANCH SIZE
BASIS OF DESIGN FIXTURE SPECIFICATIONS
REFER TO THE SPECIFICATIONS FOR APPROVED
EQUALS AND DETAILED DESCRIPTIONS
BASIS OF DESIGN SUPPLY FITTING FIXTURE
SPECIFICATIONS
REFER TO THE SPECIFICATIONS FOR APPROVED
EQUALS AND DETAILED DESCRIPTIONS MOUNTING HEIGHTW V CW HW TW
WC-1 WATER CLOSET WALL MOUNTED ADA
COMPLIANT
4" 2" 1" - - KOHLER KINGSTON MODEL K-4325, PROVIDE KOHLER STRONGHOLD MODEL K-4731-C-0
TOILET SEAT
TOTO ECOPOWER 1.28 GPF MODEL TET1LA32#CP 16 1/2"
WC-2 WATER CLOSET WALL MOUNTED 4" 2" 1" - - KOHLER KINGSTON MODEL K-4325, PROVIDE KOHLER STRONGHOLD MODEL K-4731-C-0
TOILET SEAT
TOTO ECOPOWER 1.28 GPF MODEL TET1LA32#CP 15"
UR-1 ADA COMPLIANT WALL MOUNTED URINAL 2" 1 1/2" 3/4" - - KOHLER BARDON MODEL K-4991-ET TOTO ECOPOWER 0.5 GPF MODEL TEU1LA12#CP 17" L-1 ADA COMPLIANT UNDER-MOUNT LAVATORY 2" 1 1/2" 1/2" 1/2" - KOHLER CAXTON VITREOUS CHINA UNDER-MOUNT LAVATORY MODEL K-2210, PROVIDE
SIOUX CHIEF 206-096 TRAP EASE TRAP PRIMER
SYMMONS SENSOR FAUCET MODEL S-6080-ACM-12V-0.5 33"
LF-1 SINK FAUCET - - 1/2" - - CHICAGO FAUCET MECHANICAL FAUCET MODEL
930-GN8BVB317XKCP
DECK MOUNTED
LF-2 SINK FAUCET - - 1/2" - - CHICAGO FAUCET MECHANICAL FAUCET MODEL 928-317XKCP DECK MOUNTED
LSK-1 LAB SINK 2" 1 1/2" - - - DURCON LABORATORY FIXTURES MODEL A55 SEE LF-1 34"
LSK-2 LAB SINK 2" 1 1/2" - - - DURCON LABORATORY FIXTURES MODEL D54 SEE LF-1 34"
LSK-3 LAB SINK 2" 1 1/2" - - - DURCON LABORATORY FIXTURES CUSTOM SINK 6'-0" L X 7 5/8" W X 6" D (8) SEE LF-2 34" SK-1 UNDERCOUNTER MOUNT SINK 2" 1 1/2" 1/2" 1/2" - JUST MANUFACTURING UNDER-MOUNT SINK MODEL UDN-ADA-1632-A CHICAGO FAUCET MANUAL FAUCET MODEL 2304-E35ABCP MOUNT TO COUNTER SH-1 SHOWER 2" 1 1/2" 1/2" 1/2" - AQUARIUS BATHWARE G3636-BF-3P-CENTURY STONE SOLID SURFACE WHITE SYMMONS TEMPTROL SHOWER VALVE
MODELC-96-300-B30-V-CHKS-1.5
SEE DETAIL
SH-2 SHOWER 2" 1 1/2" 1/2" 1/2" - AQUARIUS BATHWARE G3636-BF-3P-CENTURY STONE SOLID SURFACE WHITE SYMMONS TEMPTROL SHOWER VALVE
MODELC-96-300-B30-V-CHKS-1.5
SEE DETAIL
EWC-1 ELECTRONIC WATER COOLER WITH
BOTTLE FILLER
2" 1 1/2" 1/2" - - ELKAY EZH2O BOTTLE FILLING STATION MODEL LZSTLR8WSLP - 31 13/16" TO RIM OF ADA FOUNTAIN
MB-1 MOP BASIN 2" 1 1/2" 1/2" 1/2" - FIAT MOLDED STONE MSB3624 CHICAGO FAUCETS MODEL 540-LD897SWXFXKCP, MOUNT FAUCET AT
36" AFF
36"
EEWS-1 RECESSED EYEWASH & SHOWER 2" 1 1/2" - - 1" GUARDIAN EQUIPMENT RECESSED EYEWASH & SHOWER MODEL GBF2170 TV-2 36" EEWS-2 EYE/FACE WASH WITH SHOWER 2" - - - 2" GUARDIAN SAFETY STATION EYE/FACE WASH WITH SHOWER ALL PVC CONTRUCTION MODEL
G1998-FC20
- FLOOR MOUNTED
OB-1 WASHING MACHINE OUTLETBOX 2" 1 1/2" 1/2" 1/2" - SIOUX CHIEF DISHWASHER OUTLET BOX MODEL 696-1010MF SUPPLY BOX & 696-3F DRAIN
BOX
- 48"
HR-1 COLD WATER HOSE REEL - - - - - REELCRAFT MODEL 83075-OLP - MOUNT TO BOTTOM OF TRUSS HR-2 COLD WATER HOSE REEL - - - 3/4" - REELCRAFT MODEL 83075-OLP - MOUNT TO BOTTOM OF PRCAST
CONCRETE
WH-1 WALL HYDRANT 3/4" WATTS MODEL HY-725 36"
AD SHOCK ARRESTOR ACCESS PANEL - - - - - 8"x 8" ACCESS PANEL 42"
SP-1 SUMP PUMP 2" - - - - LITTLE GIANT MODEL 10EC-CIA-SFS MOUNT IN PIT
EXPANSION TANK SCHEDULE
BASIS OF DESIGN EXPANSION TANK SPECIFICATIONS REFER TO THE SPECIFICATIONS FOR APPROVED EQUALS AND DETAILED DESCRIPTIONS
TAG MANUFACTURER MODEL
VOLUME
(GALLONS)
MAXIMUM ACCEPTANCE
VOLUME
(GALLONS)
MAXIMUM OPERATING
PRESSURE
(PSI)
MAXIMUM OPERATING
TEMPERATURE
(DEG. F) NOTES
ET-1 AMTROL ST-12-C 6.4 0.9 150.00 200
WATER HEATER SCHEDULE
BASIS OF DESIGN WATER HEATER SPECIFICATIONS REFER TO THE SPECIFICATIONS FOR APPROVED EQUALS AND DETAILED DESCRIPTIONS
TAG MANUFACTURER MODEL FUEL TYPE
RECOVERY
(GPH)
BRANCH SIZE
NOTESCW HW
WHTR-1 LOCHINVAR SQUIRE MODEL ST080 INDIRECT 340 1 1/2" 1"
CIRCULATING PUMP SCHEDULE
BASIS OF DESIGN PUMP SPECIFICATION REFER TO THE SPECIFICATIONS FOR APPROVED EQUALS AND DETAILED DESCRIPTIONS
TAG MANUFACTURER MODEL LOCATION GPM
HEAD
(FT)
CONNECTION
SIZE
ELECTRICAL
NOTESVOLTS PHASE WATTS
DCP-1 GRUNDFOS ALPHA
15-55SF
MECHANICAL
ROOM
8 GPM 20.00 3/4" 120 V 1 45.00
DCP-2 GRUNDFOS ALPHA
15-55SF
MECHANICAL
ROOM
8 GPM 20.00 3/4" 120 V 1 45.00
TEMPERING VALVE SCHEDULE
BASIS OF DESIGN TEMPERING VALVE SPECIFICATIONS REFER TO THE SPECIFICATIONS FOR APPROVED EQUALS AND DETAILED DESCRIPTIONS
TAG MANUFACTURER MODEL CW HW TW
MAX. OPERATING
PRESSURE
MAX.
OPERATING
TEMPERATURE MAX. GPM MIN. GPM
TEMPERATURE
SETTING NOTES
TV-1 POWERS LFMM432HL 3/4" 3/4" 1" 125.00 200 °F 41 0.50 120°F
TV-2 POWERS ES-P-ETV400-1-5 3/4" 3/4" 1" 125.00 180 °F 48 3.00 85°F
PIPING ACCESSORY SCHEDULE
BASIS OF DESIGN PIPE ACCESSORIES SPECIFICATIONS REFER TO THE SPECIFICATIONS FOR APPROVED EQUALS AND DETAILED DESCRIPTIONS
TAG DESCRIPTION MANUFACTURER MODEL PIPE CONNECTION SIZE LOCATION
BFP-1 BACKFLOW PREVENTOR WATTS LF909M1-QT-S 1 1/2" MECHANICAL ROOM
BFP-2 BACKFLOW PREVENTOR WATTS LF909M1-QT-S 1 1/2" MECHANICAL ROOM
BFP-3 BACKFLOW PREVENTOR WATTS LF909M1-QT-S 2" MECHANICAL ROOM
BFP-4 BACKFLOW PREVENTOR WATTS LF909M1-QT-S 2" MECHANICAL ROOM
BFP-5 BACKFLOW PREVENTOR WATTS LF909M1-QT-S 1" MECHANICAL ROOM
FSW-1 FLOW SWITCH GUARDIAN EQUIPMENT AP275-615C1D2 1 1/4" -
WM-1 WATER METER BY UTILITY - 2 1/2" MECHANICAL ROOM
DRAIN SCHEDULE
BASIS OF DESIGN DRAIN SPECIFICATIONS REFER TO THE SPECIFICATIONS FOR APPROVED EQUALS AND DETAILED DESCRIPTIONS
TAG DESCRIPTION
BRANCH SIZE SPECIFICATIONS
BASIS OF DESIGN NOTESW V
FD-1 FLOOR DRAIN 4" 2" WATTS HEAVY DUTY STAINLESS STEEL FLOOR DRAIN MODEL FD-1204-M8-6
FD-2 FLOOR DRAIN 2" 1 1/2" WATTS ROUNDMEDIUM DUTY MODEL FD-102-A6-6
FD-3 FLOOR DRAIN 3" 2" WATTS ROUND MEDIUM DUTY MODEL FD-103-A10-6
FS-1 FLOOR SINK 4" 2" WATTS FLOOR SINK MODEL FS-780-4-F-150-HD
RD-1 ROOF DRAIN 6" - WATTS MODEL RD-100-F-K80-6
REF:
A1
NOTES
FIRE ALARM RED
BLUE
SIGNAL (NURSE CALL, PA)
AUDIO VISUAL
480V
277V
120V
208V
PURPLE
WHITE
BROWN
ORANGE
BLACK
COLOR CODE CHART
JUNCTION BOX IDENTIFICATION
REF:
A3
LEGEND
F FIRE ALARM MANUAL PULL STATION - MOUNTED C/L UP 48"
FIRE ALARM ADRESSABLE OUTPUT MODULE
1.
a.
2.
b.
c.
WHERE INDICATED.
PROVIDE NEW FIRE ALARM STROBES
SYSTEM NOTES
FIRE ALARM
ASSOCIATED WITH FIRE PROTECTION SYSTEMS.
AND LOCATIONS OF ALL FIRE ALARM DEVICES
REFER TO ELECTRICAL DRAWINGS FOR QUANTITIES
d.
e.
f.
WHERE INDICATED.
PROVIDE NEW FIRE ALARM PULLSTATIONS
1.
2.
3.
4.
5.
6.
GENERAL NOTES
U.L. LISTED AND LABELED.
WHERE APPLICABLE, PROVIDE ONLY MATERIALS THAT ARE
THAT COMPLY WITH ANSI, IEEE, IES, AND NEMA STANDARDS.
AND CITY AGENCIES. PROVIDE MATERIALS AND EQUIPMENT
REGULATIONS OF THE PERTINENT FEDERAL, STATE, COUNTY,
CODE (NEC), OSHA REGULATIONS, AS WELL AS APPLICABLE
THE LATEST EDITION OF NFPA 70, NATIONAL ELECTRICAL
ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH
OF THE SEPARATION.
FIRE SEALANT MATERIAL TO MAINTAIN THE RATING
AND PARTITIONS SHALL BE SEALED WITH UL APPROVED
ALL PENETRATIONS THROUGH FIRE-RATED FLOORS, WALLS
TO THE APPROVAL OF THE OWNER.
THE PROPOSED SUBSTITUTIONS SHALL BE SUBJECT
DESIRED QUALITY. ACCEPTANCE OR REJECTION OF
DESIGNATIONS ARE TO ESTABLISH STANDARDS OR
MANUFACTURER, TYPE OR CATALOG NUMBER, SUCH
WHERE MATERIAL IS CALLED OUT IN THE LEGEND BY
ALL FIRE ALARM DRAWINGS FOR THIS PROJECT.
AND DETAILS ARE TO BE CONSIDERED APPLICABLE TO
ALL GENERAL NOTES, SYMBOLS, LISTS, ABBREVIATIONS
KNOCKOUT LOCATIONS WILL NOT BE ACCEPTED.
MOUNTED CONDUIT AND JUNCTION BOXES WITH
WIREMOLD WIREMANAGEMENT SYSTEM. SURFACE
INSTALLED IN A FINISHED WIREMOLD TYPE BOX AND
MOUNTED DEVICES ARE APPROVED THEY SHALL BE
APPROVED BY OWNER AND ARCHITECT. WHEN SURFACE
DEVICES SHALL ONLY BE USED WHEN SPECIFICALLY
NEW DEVICES SHALL BE RECESSED. SURFACE MOUNTED
g. MAKE ALL CONNECTIONS AS REQUIRED.
SITUATION OCCURS.
ENGINEER FOR CLARIFICAION WHEN SUCH A
STRINGENT SHALL PREVAIL. CONTACT THE
DRAWINGS AND THE SPECIFICATIONS, THE MOST
WHERE A DISCREPANCY OCCURS BETWEEN THE
h. PROVIDE ALL REQUIRED PROGRAMMING.
S
AND OPERATIONAL SYSTEM.
DEVICES AND ACCESSORIES FOR A COMPLETE
THE NEW DEVICES INDICATED. PROVIDE ALL
ALARM CONTROL PANEL TO ACCOMMODATE
PROVIDE A NEW NOTIFIER NFS26340 VOICE FIRE
i.
AIM
AOM
FIRE ALARM ADRESSABLE INPUT MODULE
CONNECTION TO UNH DISPATCH.
PROVIDE KELTRON LSNET-922 NETWORK
S
FIRE ALARM SPEAKER/LIGHT UNIT - CANDLE POWER (CD) PER NFPA 72 OR AS NOTED - 15/75 WHERE NOT OTHERWISE INDICATED ON PLANS - CEILING MOUNTED
FIRE ALARM STROBE LIGHT UNIT - CANDLE POWER (CD) PER NFPA 72 OR AS NOTED - 15/75 WHERE NOT OTHERWISE INDICATED ON PLANS - CEILING MOUNTED
FIRE ALARM SPEAKER/LIGHT UNIT - CANDLE POWER (CD) PER NFPA 72 OR AS NOTED - 15/75 WHERE NOT OTHERWISE INDICATED ON PLANS - WALL MOUNTED
FIRE ALARM STROBE LIGHT UNIT - CANDLE POWER (CD) PER NFPA 72 OR AS NOTED - 15/75 WHERE NOT OTHERWISE INDICATED ON PLANS - WALL MOUNTED
R
KB
FIRE ALARM EXTERIOR KNOX BOX
FIRE ALARM L E G E N D
FACP FIRE ALARM CONTROL PANEL
HD
FIRE ALARM ADRESSABLE HEAT DETECTION TAPE
S
B FIRE ALARM LINEAR BEAM DETECTOR - WALL MOUNTED
APPLICABLE CODES AND STANDARDS
NFPA 70, NATIOANL ELECTRICAL CODE [2014 EDITION]
NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE [2013 EDITION]
NFPA 1, UNIFORM FIRE CODE [2009 EDITION] AS AMENDED BY THE NEW HAMPSHIRE STATE FIRE CODE
NFPA 101, LIFE SAFETY CODE [2015 EDITION] AS AMENDED BY THE NEW HAMPSHIRE STATE FIRE CODE
Saf-C 6000, NEW HAMPSHIRE STATE FIRE CODE
IBC, INTERNATIONAL BUILDING CODE [2009 EDITION] AS AMENDED BY THE NEW HAMPSHIRE STATE BUILDING CODE
FIRE ALARM COMBINATION 135 DEGREE/RATE OF RISE HEAT DETECTOR - CEILING MOUNTED
FIRE ALARM PHOTOELECTRIC SMOKE DETECTOR - CEILING MOUNTED
FIRE ALARM PHOTOELECTRIC DUCT SMOKE DETECTOR - CEILING MOUNTED
FIRE ALARM EXTERIOR WEATHERPROOF BEACON
REF:
A2
HVAC AIR DIFFUSER
SMOKE DETECTOR
>3'-0"
FIRE
CEILING
FROM
OR 6"
80"-96"
FIRE
48"
SPEAKER/STROBE
STATION
PULL
MANUAL
FACP
DISPLAY
60"
MOUNTING HEIGHT DETAIL
j.
AND ANNUNCIATION DEVICES.
PUMP STATION FOR INITIATION DEVICES
PROVIDE CONNECTIONS TO OYSTER RIVER
FIRE ALARM SYSTEM REMOTE ANNUNCIATOR - MOUNTED C/L UP 48"FANN
k. PROVIDE REMOTE ANNUNCIATOR AS INDICATED.
WHERE INDICATED.
PROVIDE NEW FIRE ALARM SPEAKER/STROBES
WHERE INDICATED.
PROVIDE NEW FIRE ALARM HEAT DETECTORS
MODULES WHERE INDICATED.
PROVIDE NEW FIRE ADDRESSABLE INPUT
WHERE INDICATED.
PROVIDE NEW FIRE ALARM SMOKE DETECTORS
l.
m.
PROVIDE ROTATING BEACON AS INDICATED.
PROVIDE SECURITY KEY BOX AS INDICATED.
R E
P R
O D
U C
T
IO
M
D
IF
IC
A T
IT
H O
T
IT
T
R M
IS
S
IO
IS
O H
IB
IT
E D
T H
C U
M E
N
O P
E R
Y
F
O D
A
R R
A N
IN
C
A N
D
L
IE
N T
C H
E C
K
B
D E
S
IG
N
D A
T E
D E
S C
R
IP
T
IO
N R
E V
D R
A
W O
O D
A R
D C
U R
R A
N C
O M
M
IT
M E
N T I N
T E
G R
IT
Y D
R
IV
E R
E S
U L T S
B
A
C
D
B
A
C
D
2 3 4 5 61
JOB NO.:
SCALE:
DATE:
SHEET: OF
2 3 4 5 61
S h a tt u c k R o a d S u it e
A n d o v e r, M a s s a c h u s e tt s
.7 .6 w w w .w o o d a rd c u rr a n .c o m
O D
A R
D C
U R
R A
N
D U
R H
A M
N
M P
S H
IR
E
U N
IV
E R
S
M P
S H
IR
E
16621
1/8" = 1'-0"
PART 1B 90% DESIGN SUBMITTAL
MAY 5, 2017
J W
T
B S
O
A P
G R
E P
L A
C E
M E
N T
W A
T
E A
T M
E
A N
T
U
O J E
C T
ID
FA-100.1
A N
D N
O T E S
F
IR
E A
L A
R M L
E G
E N
D D
E T
A
IL
D W
UP
UPDN
MAINTENANCE AREA
TRAINING LAB
LAB STO
130A
TRAINING VEST
VS102
BREAK ROOM
LABORATORY
MENS TOILET
WOMENS TOILET
VEST
100VSA
CONFERENCE ROOM
SUPERVISOR
STAFF OFFICE
JAN
LAB STO
106A
CONTROL ROOM
120B
CHANGING
UNISEX
CHANGING
UNISEX
CHEMICAL STORAGE
120A
CORRIDOR
100CRA
WATER TREATMENT
RECORDS
106B
TOILET
MECH ROOM
120G
ELEC ROOM
120E
IT ROOM
DRY STO
F
S S15cd
15cd
15cd
15cd
15cd
15cd
15cd 15cd
15cd
S
30cd
S 30cd S
15cd
15cd
30cd
KBR
15cd
S
15cd
S
15cd
S 15cd
S
S
S
15cd
15cd S
S
15cd
S 30cd
F
F
F
F
TS
TS
FS
FS
FS
FS
F
F
75cd
AIM AIM AIM
AIM AIM AIM
75cdS 75cdS
HD HD
HD HD HD
15cd
S15cd
15cd
S
75cdS
75cd
S
75cd
S
75cd
75cdS
75cdS 75cdS 75cdS
S75cd
HD
FF
F
AIM
FIRE EXTINGUISHER
AIM
FIRE EXTINGUISHER
AIM
FIRE EXTINGUISHER
AIM
FIRE EXTINGUISHER
AIM
FIRE EXTINGUISHER
AIM
FIRE EXTINGUISHER
F A
N N
F A
C P
R E
P R
O D
U C
T
D
IF
IC
A T
H O
IT
T
R M
IS
S
IO
O H
IB
IT
E D
T
C U
M E
N
O P
E R
O D
A
R R
A N
IN
C
A N
D
IE
N T
C H
E C
K
D E
S
IG
N
D A
T E
D E
S C
R
IP
T
IO
N R
E V
D R
A
W O
O D
A R
D C
U R
R A
N C
O M
M
IT
M E
N T I N
T E
G R
IT
Y D
R
IV
E R
E S
U L T S
B
A
C
D
B
A
C
D
2 3 4 5 61
JOB NO.:
SCALE:
DATE:
SHEET: OF
2 3 4 5 61
S h a tt u c k R o a d S u it e
A n d o v e r, M a s s a c h u s e tt s
.7 .6 w w w .w o o d a rd c u rr a n .c
O D
A R
D C
U R
R A
N
D U
R H
A M
N
M P
S H
IR
E
U N
IV
E R
S
M P
S H
IR
E
16621
1/8" = 1'-0"
PART 1B 90% DESIGN SUBMITTAL
MAY 5, 2017
J W
T
B S
O
A P
G R
E P
L A
C E
M E
N T
W A
T
E A
T M
E
A N
T
U
O J E
C T
ID
MAINTENANCE AREA
F
HD
HD
S
75cd
MAINTENANCE AREA PART PLAN
SCALE: 1/8" = 1'-0"
FA-110.1
PIPE GALLERY PART PLAN
SCALE: 1/8" = 1'-0"
P
IP
E G
A L L E
R Y P
A R
T P
L A
N
F
IR
E A
L A
R M F
IR
S T F
L O
O R P
L A
N A
DN
TANK MEZZ
M20A
MECH ATTIC
M20G
HATCH
S
F
30cd
30cd
F
F
S
S
110cd
110cd
UNISTRUT MOUNTED
UNISTRUT MOUNTED
UNISTRUT MOUNTED
UNISTRUT MOUNTED
F
S
15cd
S
S B
S B
S B
S B
R E
P R
O D
U C
T
D
IF
IC
A T
H O
IT
T
R M
IS
S
IO
O H
IB
IT
E D
T
C U
M E
N
O P
E R
O D
A
R R
A N
IN
C
A N
D
IE
N T
C H
E C
K
D E
S
IG
N
D A
T E
D E
S C
R
IP
T
IO
N R
E V
D R
A
W O
O D
A R
D C
U R
R A
N C
O M
M
IT
M E
N T I N
T E
G R
IT
Y D
R
IV
E R
E S
U L T S
B
A
C
D
B
A
C
D
2 3 4 5 61
JOB NO.:
SCALE:
DATE:
SHEET: OF
2 3 4 5 61
S h a tt u c k R o a d S u it e
A n d o v e r, M a s s a c h u s e tt s
.7 .6 w w w .w o o d a rd c u rr a n .c
O D
A R
D C
U R
R A
N
D U
R H
A M
N
M P
S H
IR
E
U N
IV
E R
S
M P
S H
IR
E
16621
1/8" = 1'-0"
PART 1B 90% DESIGN SUBMITTAL
MAY 5, 2017
J W
T
B S
O
A P
G R
E P
L A
C E
M E
N T
W A
T
E A
T M
E
A N
T
U
O J E
C T
ID
FA-110.2
F
IR
E A
L A
R M M
E Z Z
A N
IN
E P
L A
KB R
75cd
HD
(1) FIRE ALARM INITIATION CIRCUIT AND (1) FIRE ALARM ANNUNCIATION CIRCUIT.
1" PVC UNDERGROUND DUCTBANK CONDUIT TO WATER TREATMENT PLANT WITH
R E
P R
O D
U C
T
D
IF
IC
A T
H O
IT
T
R M
IS
S
IO
O H
IB
IT
E D
T
C U
M E
N
O P
E R
O D
A
R R
A N
IN
C
A N
D
IE
N T
C H
E C
K
D E
S
IG
N
D A
T E
D E
S C
R
IP
T
IO
N R
E V
D R
A
W O
O D
A R
D C
U R
R A
N C
O M
M
IT
M E
N T I N
T E
G R
IT
Y D
R
IV
E R
E S
U L T S
B
A
C
D
B
A
C
D
2 3 4 5 61
JOB NO.:
SCALE:
DATE:
SHEET: OF
2 3 4 5 61
S h a tt u c k R o a d S u it e
A n d o v e r, M a s s a c h u s e tt s
.7 .6 w w w .w o o d a rd c u rr a n .c
O D
A R
D C
U R
R A
N
D U
R H
A M
N
M P
S H
IR
E
U N
IV
E R
S
M P
S H
IR
E
16621
1/8" = 1'-0"
PART 1B 90% DESIGN SUBMITTAL
MAY 5, 2017
J W
T
B S
O
A P
G R
E P
L A
C E
M E
N T
W A
T
E A
T M
E
A N
T
U
O J E
C T
ID
FA-310.1
F
IR
S T F
L O
O R P
L A
N
F
IR
E A
L A
R M O
Y S T E
R R
IV
E R P
U M
P S
T A T
IO
TWO 3/4" DIAMETER
RODS
CAST IN PLACE PIPE
SLEEVE WITH
MINERAL WOOL
INSULATION AND
WATERPROOF
CEMENT
5 BOLT FLANGE
THRUST BLOCK
TO SYSTEM
RISER
2" RIGID
INSULATION
FINISH GRADE
FOUNDATION
WALL
MECHANICAL
SLEEVE - SEAL
AT FLOOR
PENETRATION
6" WATER LINE
FINISH GRADE
8"x18"x1-1/2"
CONCRETE
SPLASH BLOCK
FOR DRAIN. SET
FLUSH WITH
GRADE.
BRONZE 45° ELBOW, LOCATED
2' ABOVE GRADE, EQUIPPED
WITH A SMOOTH BORE
CORROSION-RESISTANT
OUTLET GIVING FLOW
EQUIVALENT TO THE
SMALLEST SPRINKLER ORIFICE
IN THE SYSTEM
TEST VALVE IN
READILY
ACCESSIBLE
LOCATION
ESCUTCHEON
(WALL PLATE)
1" DROP FROM
END OF REMOTE
BRANCH LINE
SILICON SEALANT - BOTH
SIDES
FIBERGLASS
INSULATION
AROUND
PROTRUDING
PIPE
FINISHED
CEILING
PENDENT TYPE
SPRINKLER HEAD WITH
RECESSED ESCUTCHEON,
UL/ FM APPROVED.
REFERENCE FIRE
PROTECTION
SPECIFICATIONS FOR
ADDITIONAL
INFORMATION.
REFERENCE
SPRINKLER
MANUFACTURER
FOR REQUIRED
CEILING
OPENING
1" MIN
1 3/4" MAX
STANDARD ORIFICE
SPRINKLER HEAD
1"x1/2" REDUCTION
NOTE: ALL DROPS TO SPRINKLER HEADS
SHALL COME OFF OF THE TOP OF THE
BRANCH LINES, EXCEPT WHERE
STRUCTURAL, ARCHITECTURAL, OR
MECHANICAL EQUIPMENT CONDITIONS
PRECLUDE CONVENTIONAL INSTALLATION.
1" PIPING
TYPICAL
BRANCH LINE
REDUCING TEE
FINISH GRADE
4" FIRE
DEPARTMENT
CONNECTION
(FDC). LOCATE
NOT LESS THAN
18" AND NOT
MORE THAN 4'
ABOVE GRADE
LEVEL
WET-PIPE
SYSTEM TO
ADMIN WING
DRY-PIPE PIPING
TO ATTIC
SYSTEM
6" WATER
ENTRANCE
6" DOUBLE
CHECK VALVE
WET-PIPE
SYSTEM TO
CHEM FEED
ROOM
ELECTRIC BELL
ON EXTERIOR
WALL
OS&Y GATE
VALVE WITH
TAMPER SWITCH
(TYPICAL)
ALARM VALVE
W/ TRIM
4" BACK CHECK
VALVE
DRY VALVE
W/ TRIM
RISER MOUNTED
AIR COMPRESSOR
W
OO
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
FP-1
FI
RE
P
RO
TE
CT
IO
N
NO
TE
S
22x34 SHEET
ACT1
8' - 6"
ACT1
9' - 0"
ACT1
8' - 6"
GPDW-2
9' - 6"
ACT1
9' - 0"
ACT1
9' - 0"
ACT1
9' - 0"
ACT1
9' - 0"
ACT1
9' - 0"
ACT1
9' - 0"
ACT1
9' - 6"
ACT1
9' - 0"
ACT1
9' - 0"
ACT1
9' - 0"
ACT1
9' - 0"
ACT1
9' - 6"
ACT1
9' - 0"
GPDW-1
10' - 7 3/4"
ACT1
8' - 6"
CLG1
9' - 0"
GPDW-1
10' - 7 3/4"
GPDW-1
10' - 8"
GPDW-2
9' - 6"
ACT1
8' - 0"
ACT1
8' - 6"
ACT1
8' - 6"
ACT1
9' - 0"
W
OO
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
FP-2
FI
RS
T
FL
OO
R
PL
AN
22x34 SHEET
DN
TANK MEZZ
M20A
MECH ATTIC
M20G
W
OO
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
FP-3
AT
TI
C
PL
AN
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
E-001
EL
EC
TR
IC
AL
S
YS
TE
M
LE
GE
ND
LA
YO
UT
22x34 SHEET
F
D
W
U
P
U
P
D
N
R
E
F
M
A
I
N
T
E
N
A
N
E
A
T
R
A
I
N
I
G
B
L
O
A
T
R
A
I
N
I
V
S
T
V
S
B
R
E
K
O
M
L
A
B
O
R
A
T
O
R
Y
M
E
I
L
E
T
W
O
M
E
I
L
E
T
V
E
S
T
V
S
A
C
O
N
F
E
R
E
N
O
M
S
U
P
E
R
V
I
S
O
R
S
T
A
F
I
C
E
J
A
N
L
O
A
C
O
N
T
R
O
M
B
U
N
I
S
E
X
C
H
A
N
G
I
N
G
U
N
I
S
E
X
C
H
A
N
G
I
N
G
C
H
E
M
I
C
O
R
A
G
E
A
C
O
R
R
I
D
O
R
C
R
A
W
A
T
E
A
T
M
E
N
T
R
E
C
O
R
D
S
B
T
O
I
L
E
T
M
E
O
M
G
E
L
O
M
E
I
O
M
D
O
R
E
F
D
W
U
P
L
A
B
O
R
A
T
O
R
Y
M
E
I
L
E
T
W
O
M
E
I
L
E
T
V
E
S
T
V
S
A
C
O
N
F
E
R
E
N
O
M
J
A
N
L
O
A
C
O
N
T
R
O
M
B
C
H
E
M
I
C
O
R
A
G
E
A
C
O
R
R
I
D
O
R
C
R
A
R
E
C
O
R
D
S
B
M
E
O
M
G
E
L
O
M
E
O
M
D
O
BAR SCALE
CHECK GRAPHIC SCALE BEFORE USING
E-005
EL
EC
TR
IC
AL
S
IT
E
PL
AN
22x34 SHEET 1:1
PART 1B 90% DESIGN SUBMITTAL
BAR SCALE
CHECK GRAPHIC SCALE BEFORE USING
W
OO
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co
F
D
W
U
P
U
P
D
N
R
E
F
M
A
I
N
T
E
N
A
N
E
A
T
R
A
I
N
I
B
L
O
A
T
R
A
I
N
I
V
S
T
V
S
B
R
E
K
O
M
L
A
B
O
R
A
T
O
R
Y
M
E
I
L
E
T
W
O
M
E
I
L
E
T
V
E
S
T
V
S
A
C
O
N
F
E
R
E
N
O
M
S
U
P
E
R
V
I
S
O
R
S
T
A
F
I
C
E
J
A
N
L
O
A
C
O
N
T
R
O
M
B
U
N
I
S
E
X
C
H
A
N
G
I
N
G
U
N
I
S
E
X
C
H
A
N
G
I
N
G
C
H
E
M
I
C
O
R
A
G
E
A
C
O
R
R
I
D
O
R
C
R
A
W
A
T
E
A
T
M
E
N
T
R
E
C
O
R
D
S
B
T
O
I
L
E
T
M
E
O
M
G
E
L
O
M
E
O
M
D
O
W
OO
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
BAR SCALE
CHECK GRAPHIC SCALE BEFORE USING
E-006
GR
OU
ND
IN
G
PL
AN
22x34 SHEET ɸ ɸ ɸ ɸ ɸ
W
OO
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
E-010
W
AT
ER
T
RE
AT
ME
NT
P
LA
NT
ON
E-
LIN
E
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
E-100
W
AT
ER
T
RE
AT
ME
NT
P
LA
NT
P
IP
E
GA
LL
ER
Y
PO
W
ER
P
LA
N
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
E-101
W
AT
ER
T
RE
AT
ME
NT
P
LA
NT
F
IR
ST
F
LO
OR
PO
W
ER
P
LA
N
SH
EE
T
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
E-102
W
AT
ER
T
RE
AT
ME
NT
P
LA
NT
F
IR
ST
F
LO
OR
PO
W
ER
P
LA
N
SH
EE
T
22x34 SHEET
BREAK ROOM
MENS TOILET
WOMENS TOILET
VEST
100VSA
CONFERENCE ROOM
SUPERVISOR
STAFF OFFICE
JAN
CORRIDOR
100CRA
W
OO
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
E-103
W
AT
ER
T
RE
AT
ME
NT
P
LA
NT
F
IR
ST
F
LO
OR
PO
W
ER
P
LA
N
SH
EE
T
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
E-104
W
AT
ER
T
RE
AT
ME
NT
P
LA
NT
ME
ZZ
AN
IN
E
LE
VE
L P
OW
ER
P
LA
N
SH
EE
T
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
E-105
W
AT
ER
T
RE
AT
ME
NT
P
LA
NT
ME
ZZ
AN
IN
E
LE
VE
L P
OW
ER
P
LA
N
SH
EE
T
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
E-110
EL
EC
TR
IC
AL
P
IP
E
GA
LL
ER
Y
CO
NT
RO
LS
P
LA
N
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
E-111
W
AT
ER
T
RE
AT
ME
NT
P
LA
NT
F
IR
ST
F
LO
OR
CO
NT
RO
LS
P
LA
N
SH
EE
T
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
E-112
W
AT
ER
T
RE
AT
ME
NT
P
LA
NT
F
IR
ST
F
LO
OR
CO
NT
RO
LS
P
LA
N
SH
EE
T
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
E-113
EL
EC
TR
IC
AL
M
EZ
ZA
NI
NE
LE
VE
L
CO
NT
RO
LS
P
LA
N
SH
EE
T
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
E-120
W
AT
ER
T
RE
AT
ME
NT
P
LA
NT
P
IP
E
GA
LL
ER
Y
LIG
HT
IN
G
PL
AN
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
E-121
W
AT
ER
T
RE
AT
ME
NT
P
LA
N
FI
RS
T
FL
OO
R
LIG
HT
IN
G
PL
AN
S
HE
ET
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
E-122
W
AT
ER
T
RE
AT
ME
NT
P
LA
N
FI
RS
T
FL
OO
R
LIG
HT
IN
G
PL
AN
S
HE
ET
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
E-123
W
AT
ER
T
RE
AT
ME
NT
P
LA
NT
F
IR
ST
F
LO
OR
LIG
HT
IN
G
PL
AN
S
HE
ET
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
E-124
W
AT
ER
T
RE
AT
ME
NT
P
LA
NT
ME
ZZ
AN
IN
E
LE
VE
L L
IG
HT
IN
G
PL
AN
22x34 SHEET
DA
RD
CU
RR
AN
CO
MM
IT
ME
NT
IN
TE
GR
IT
Y
DR
IV
E
RE
SU
LT
S
S ha ttu ck R oa d, S ui te
An do ve r, Ma ss ac hu se tts
6.7
.63 w ww
.w oo da rd cu rra n.
co m
E-130
W
AT
ER
T
RE
AT
ME
NT
P
LA
NT
P
IP
E
GA
LL
ER
Y
PO
W
ER
P
LA
N
22x34…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .