A.02 SOW_Att 3_Conceptual Floor Plans.pdf

PDF 1 MB Posted

Attached to
Birzai Fire and Rescue Station Reno, Lithuania
Solicitation number
W912GB25R0035
Issued by

About this file

The document is a set of conceptual floor plans for the renovation of a Fire and Rescue Station in Birzai, Lithuania, containing detailed architectural drawings for four levels: basement, first floor, second floor, and attic. The plans outline specific renovation requirements for each floor, including:

Basement Plan: Requires new thermal insulation and waterproofing of exterior walls, and new exterior drainage around the building perimeter. First Floor Plan: Involves converting an existing room to a new communications (COM) room, blocking an existing door, demolishing existing stairs, and providing a new interior door and steps. The plan also calls for all new windows, exterior doors, vehicle overhead doors, and EIFS (Exterior Insulation and Finish System) for all exterior walls. Second Floor and Attic Plans: Specify providing all new windows, repairing existing balconies, installing new EIFS for exterior walls, and adding new roof and attic thermal insulation, with a note to maintain the existing annex bituminous roofing.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BASEMENT PLAN – RENOVATION OF FIRE AND RESCUE STATION ‐ BIRZAI, LITHUANIA – RFP, SEC. 011010, SOW, ATT. 3

‐ PROVIDE NEW THERMAIL INSULATION

AND WATERPROOFING OF BASEMENT

EXTERIOR WALLS

‐ PROVIDE NEW EXTERIOR DRAINAGE

AROUND BUILDING PERIMETER

NOTES

17.52

7.00

5.90

6.72 4.90

FIRST FLOOR PLAN – RENOVATION OF FIRE AND RESCUE STATION ‐ BIRZAI, LITHUANIA – RFP, SEC. 011010, SOW, ATT. 3

CONVERT EXISTING

ROOM TO NEW

COM ROOM

BLOCK EXISTING DOOR

AND DEMO EXIST. STAIRS

PROVIDE NEW INT. DOOR,

DOOR OPENING, AND STEPS

LEGEND

‐ PROVIDE ALL NEW WINDOWS,

EXTERIOR DOORS, AND VEHICLE

OVERHEAD DOORS

‐ PROVIDE NEW EIFS FOR

ALL EXTERIOR WALLS

NOTES

MOVE EXIST. COM BOX

TO NEW COM ROOM

6.33

9.50

6.72 5.90 4.90

7.00 9.40

7.00

5.90

6.72 4.90

7. 15 6.75

MAIN BUILDING ANNEX

SECOND FLOOR PLAN – RENOVATION OF FIRE AND RESCUE STATION ‐ BIRZAI, LITHUANIA – RFP, SEC. 011010, SOW, ATT. 3

‐ PROVIDE ALL NEW WINDOWS AND

REPAIR EXIST. BALCONIES

‐ PROVIDE NEW EIFS FOR

ALL EXTERIOR WALLS

NOTES

6.72 5.90 4.90

7.00 9.40

7.00

5.90

6.72 4.90

BALC.

BALC.

ATTIC PLAN – RENOVATION OF FIRE AND RESCUE STATION ‐ BIRZAI, LITHUANIA – RFP, SEC. 011010, SOW, ATT. 3

‐ PROVIDE ALL NEW WINDOWS AND

REPAIR EXIST. BALCONIES

‐ PROVIDE NEW EIFS FOR

ALL EXTERIOR WALLS

NOTES

‐ PROVIDE NEW ROOF AND

ATTIC THERMAL INSULATION

‐ EXISTING ANNEX BITUMINOUS

ROOFING MUST REMAIN

6.00 7.00

1.003.40 3.60

7.00