A.02 SOW_Att 3_Conceptual Floor Plans.pdf

PDF 1 MB Posted

Attached to
Birzai Fire and Rescue Station Reno, Lithuania
Solicitation number
IEU-25-0024
Issued by

About this file

This file contains architectural floor plans showing the basement, first floor, second floor and attic layouts for the renovation of a Fire and Rescue Station in Birzai, Lithuania. The plans are labeled as attachments to an RFP, Section 011010, SOW, Att. 3.

The renovation work includes several major components across all floors: new thermal insulation and waterproofing of basement exterior walls, new exterior drainage around the building perimeter, new EIFS (Exterior Insulation Finishing System) for all exterior walls, replacement of all windows and exterior doors including vehicle overhead doors, repair of existing balconies, and new roof and attic thermal insulation. The first floor plans show specific interior modifications including converting an existing room to a new communications room, blocking an existing door and demolishing existing stairs, and providing a new interior door, door opening and steps. The building consists of a main section and an annex, with dimensions clearly marked on each floor plan. The existing annex bituminous roofing must remain in place according to the attic plan notes.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BASEMENT PLAN – RENOVATION OF FIRE AND RESCUE STATION ‐ BIRZAI, LITHUANIA – RFP, SEC. 011010, SOW, ATT. 3

‐ PROVIDE NEW THERMAIL INSULATION

AND WATERPROOFING OF BASEMENT

EXTERIOR WALLS

‐ PROVIDE NEW EXTERIOR DRAINAGE

AROUND BUILDING PERIMETER

NOTES

17.52

7.00

5.90

6.72 4.90

FIRST FLOOR PLAN – RENOVATION OF FIRE AND RESCUE STATION ‐ BIRZAI, LITHUANIA – RFP, SEC. 011010, SOW, ATT. 3

CONVERT EXISTING

ROOM TO NEW

COM ROOM

BLOCK EXISTING DOOR

AND DEMO EXIST. STAIRS

PROVIDE NEW INT. DOOR,

DOOR OPENING, AND STEPS

LEGEND

‐ PROVIDE ALL NEW WINDOWS,

EXTERIOR DOORS, AND VEHICLE

OVERHEAD DOORS

‐ PROVIDE NEW EIFS FOR

ALL EXTERIOR WALLS

NOTES

MOVE EXIST. COM BOX

TO NEW COM ROOM

6.33

9.50

6.72 5.90 4.90

7.00 9.40

7.00

5.90

6.72 4.90

7. 15 6.75

MAIN BUILDING ANNEX

SECOND FLOOR PLAN – RENOVATION OF FIRE AND RESCUE STATION ‐ BIRZAI, LITHUANIA – RFP, SEC. 011010, SOW, ATT. 3

‐ PROVIDE ALL NEW WINDOWS AND

REPAIR EXIST. BALCONIES

‐ PROVIDE NEW EIFS FOR

ALL EXTERIOR WALLS

NOTES

6.72 5.90 4.90

7.00 9.40

7.00

5.90

6.72 4.90

BALC.

BALC.

ATTIC PLAN – RENOVATION OF FIRE AND RESCUE STATION ‐ BIRZAI, LITHUANIA – RFP, SEC. 011010, SOW, ATT. 3

‐ PROVIDE ALL NEW WINDOWS AND

REPAIR EXIST. BALCONIES

‐ PROVIDE NEW EIFS FOR

ALL EXTERIOR WALLS

NOTES

‐ PROVIDE NEW ROOF AND

ATTIC THERMAL INSULATION

‐ EXISTING ANNEX BITUMINOUS

ROOFING MUST REMAIN

6.00 7.00

1.003.40 3.60

7.00