A.02.17_Att 4_Structural Calculation guidline.pdf

PDF 129 KB Posted

Attached to
IEU-23-0003 Tsirguliina School Renovation Federal contract opportunity
Solicitation number
IEU-23-0003
Issued by
Department of the Army European Command

About this file

This document contains guidelines for the preparation of structural calculations for construction projects within the US Army Corps of Engineers Europe District area of responsibility. The guidelines standardize the format and required elements for structural calculations to ensure they are reviewable, executable, and meet a standard quality level. Calculations must include a cover sheet, table of contents, preliminary remarks, overview drawings, load assumptions, detailed calculations and sketches, connection force tables, and be signed by the designer. Calculations are required to verify the load bearing capacity, stability, and deflection of all structural components and connections using the stated codes and literature. Printed output from digital calculations must clearly show input parameters and highlight essential results.

A separate federal contract opportunity notice announces a potential pre-solicitation for design and construction services to renovate the Tsirguliina School in Estonia. Interested offerors should monitor the website for a formal solicitation to be issued within 30 days with full project details. The solicitation will seek a single design-build firm fixed price contract between $1-5 million USD to complete 100% design and construction within one to two years. Interested parties should submit a response form with company information to the named contracting officer. All offerors must be registered in the System for Award Management to be eligible for award.

View the file

Other files for this federal contract opportunity

Other files attached to IEU-23-0003 Tsirguliina School Renovation, newest first.
File Type Posted
B.08.02 Att 11 Commitment Letters.docx DOCX document
B.08.02 Att 8_BLA Template.docx DOCX document
B.08.02 Att 7_01 22 00 Pay Terms Bid Schedule.docx DOCX document
A.02.17 SOW Tsirguliina School Renovation.pdf PDF
A.02.17_Att 1_Proj Location Map.pdf PDF
B.07.01 Att 6_Site Visit Registration Spreadsheet.xlsx XLSX spreadsheet
B.08.02 Att 10_PPQ.pdf PDF
B.08.02 Att 8_BLA Template.docx DOCX document
A.02.17_Att 2_Conceptual Site Plan.pdf PDF
A.02.17_Att 3_Roof Areas.pdf PDF
A.03.16 Att 5_Specs Binder IAF-23-0003 Tsirguliina.pdf PDF
B.08.02 Att 9_BLG Template.docx DOCX document
Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DEPARTMENT OF THE ARMY

U.S. ARMY CORPS OF ENGINEERS

EUROPE DISTRICT

CMR 410, BOX 1

APO AE 09096-0001

CENAU-EC-E July 2016

ENGINEERING GUIDELINE 01/2016

SUBJECT: PREPARATION OF STRUCTURAL CALCULATIONS

I. BACKGROUND

The intent of the Guideline is to provide a standard format to be used for all structural calculations prepared for construction projects within the USACE NAU Area of Responsibility.

The application of this guideline for all Structural Calculation Submittals will guarantee a reviewable and executable structural submittal at a standard quality level.

II. ENGLISH VERSION

A. For all structural calculations, the following requirements apply:

Each calculation must be self-contained and complete.

It must enable further use by third-parties.

It must be clearly and fully structured.

It must be readable and reviewable.

It must be able to be copied and scanned.

Stress and deflection of the loadbearing system is to be verified in a complete, clearly presented and reviewable way for all construction components and connections.

It must contain all information required for the connection design.

Print-outs of digitally supported calculations must be complete, comprehensible and reproducible. They shall clearly define input data such as the magnitude and location of all loads, member sizes, support locations and fixity, and the units of measure.

The essential results of the calculations shall be highlighted (e.g. the internal forces used for follow on calculations)

B. Structural calculations are to be structured as follows:

1. Cover sheet

2. Table of contents

3. Preliminary remarks

4. Overview drawings, position plans,

5. Load assumptions/approaches

6. Calculations and verification, construction sketches

7. Bearing reaction (connection force table)

8. Signed final sheet

9. Attachments

CENAU-EC-E ENGINEERING GUIDELINE 01/2016

C. The following paragraphs provide more detailed descriptions on the outline of the subsequent items:

1. Cover sheet

Project name

Project number

Ordering party / responsible construction agent

Designer

Date

2. Table of contents

3. Preliminary remarks

Short description of the building/structure (dimensions, use, structural systems for the transfer of vertical and horizontal loads, special characteristics of the supporting structure), deflection limits, positioning of expansion joints etc.

Information on the location (e.g. wind load zones, snow load zones, elevation above MSL, special geographic location (e.g. on a mountain top), seismic zone,…

Materials used

Information on subgrade conditions

Standoff distances and applicable explosive weight for blast pressures and impulse loads

Codes and literature used

Computer software used, under indication of the version number and the name of the company

Listing of the drawings that belong to the structural assessment

4. Overview drawings, position plans

Drawings that enable the review of the feasibility of the structure and the bracing elements, the location of the designed element positions in the overall supporting structure as well as all structural drawings/sketches:

Well viewable depiction of the structural stability systems

Axis and row denominations as well as height marks (height above datum)

Global coordinate system

System dimensions

Position numbers

Joint layout

5. Load assumptions/approaches

Information on load assumptions/approaches such as self-weight, snow loads, wind loads, seismic loads, live loads etc.

CENAU-EC-E ENGINEERING GUIDELINE 01/2016

6. Calculations, verification and structural sketches

Calculations for all internal forces and deflections as well as the verification of load-bearing capacity, usability, fatigue, position stability etc. The layout shall look as follows for each item:

Indication of the position number and name of the supporting structure components (e.g. eaves purlin, gable wall strut etc.)

System drawing with dimensioning, load-bearing situation and information on bracing quality

List of loads and load combinations

Calculations of structural capacity, if applicable insert computerized/digital print-outs

Assessment of structural capacities

Verifications

Information on cambering

Structural sketches on all verified details

Verification of all connections to include the structural sketches or reference to connection force tables

7. Bearing reaction (connection force tables), delegated design components

If the transfer of loads is interrupted at some point of the design (e.g. designer calculates the structural system and provides loads to another to design the foundations), then the forces to be transferred must be presented in such a way that third parties can conduct corresponding design or review/verification of these loads at all times. These loads shall be presented in foundation load tables and connection force tables for all connections that are not a part of the detailed structural design. Forces for f = 1.0 from each load condition are to be indicated with reference to the global coordinate system.

For delegated design components the design shall provide applicable load and deflection criteria.

8. Final page

Designer’s name plus stamp and signature.

9. Attachment e.g. computerized/digital print-outs