864252603 Attachments.docx
DOCX document 23 KB Posted
- Solicitation number
- 116-864252603
- Issued by
- Richmond County, North Carolina
About this file
This is an attachments packet for a solicitation issued by Randolph Community College in North Carolina for a refurbished 3D mammography imaging system. The College seeks a Hologic Selenia Dimensions-equivalent platform or approved alternative manufactured in 2014 or newer to support its Radiography program. The system must include digital breast tomosynthesis (3D imaging), 2D full-field digital mammography (FFDM), C-View technology, and Computer-Aided Detection (CAD) functionality with ImageChecker and Citra capabilities. The equipment must be fully refurbished to Original Equipment Manufacturer (OEM) standards and integrate with the College's existing IQ-View Picture Archiving and Communication System (PACS). Vendors must provide certified installation, radiation safety validation, all required accessories, software licenses, and documentation. The solicitation requires submission of five mandatory attachments: a Refurbishment Certification Form documenting all refurbishment steps and quality control results, an Installer and Technician Credential Form verifying OEM training and mammography installation experience, a Service Provider Disclosure Form identifying the warranty service provider and technician qualifications, a System Equivalency Evaluation Matrix for vendors offering alternative systems, and a Manufacturing Date Verification Form confirming the equipment meets the 2014-or-newer requirement.
Vendors must provide a minimum 12-month warranty with 48-72 hour on-site service response capability and demonstrate technical competency through detailed documentation of refurbishment processes, component replacement, electrical safety testing, detector performance validation, and final quality control and calibration results. Only vendors capable of meeting all technical specifications and submitting a complete Attachment Packet (A-E) with required certifications and supporting documentation will be considered for award. The file does not specify pricing terms, bid response dates, or contract award dates.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 864252603 Refurbished Mammography Equipment.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Randolph Community College Mammography Equipment Solicitation Attachment Packet (A–E) Solicitation Title: Refurbished Mammography Equipment Solicitation Number: 864252603 Issuing Agency: Randolph Community College Division: College Services / Purchasing
Table of Contents Attachment A – Refurbishment Certification Form Attachment B – Installer & Technician Credential Form Attachment C – Service Provider Disclosure Form Attachment D – System Equivalency Evaluation Matrix Attachment E – Manufacturing Date Verification Form
ATTACHMENT A – REFURBISHMENT CERTIFICATION FORM
Vendor Name: __________________________________________ Equipment Make/Model Offered: __________________________________________ Serial Number(s): __________________________________________ A. Refurbishment Steps Completed (Vendor shall check each completed item) [ ] Full electrical inspection and reconditioning [ ] Replacement of worn electrical components [ ] Replacement or refurbishment of detector components [ ] X-ray generator calibration [ ] Detector calibration [ ] Mechanical component restoration [ ] Cosmetic restoration (covers, panels, shielding surfaces) [ ] System-level quality control testing [ ] OEM-equivalent tomosynthesis and CAD performance verification B. Required Documentation Attached (Vendor must attach all items) [ ] Refurbishment checklist [ ] Component replacement list [ ] Electrical safety testing report [ ] Final QC and calibration results [ ] Detector performance documentation (uniformity, bad pixel map, flat-field) Certification I hereby certify that the equipment offered meets or exceeds the refurbishment requirements of this solicitation.
Authorized Representative Name: ___________________________________ Title: ___________________________________ Signature: ___________________________________ Date: ___________________________________
ATTACHMENT B – INSTALLER & TECHNICIAN CREDENTIAL FORM
A. Installer Personnel Information Paste the table below into Word and then Convert Text to Table (Tabs).
| Installer Name |
| Training/Certification |
| Type of Certificate |
| Issuing Entity |
| Expiration Date |
| Years of Mammography Installation Experience |
(Add rows as needed) B. Documentation Attached [ ] OEM training credentials [ ] Equivalent manufacturer-recognized training [ ] Electrician licenses (if applicable) [ ] Proof of mammography installation experience Certification I certify that the installers listed meet all qualifications required in Sections 3.9 and 3.12 of the solicitation.
ATTACHMENT C – SERVICE PROVIDER DISCLOSURE FORM
A. Primary Warranty Service Provider Company Name: __________________________________________ Location: __________________________________________ Distance from RCC: __________ miles Average On-Site Response Time: __________ hours B. Technician Credentials Attached [ ] OEM or factory training certificates [ ] Service technician resumes or experience summaries [ ] Documentation of specialization in mammography systems C. Subcontractor Disclosure If subcontractors will be used for any installation, repair, or maintenance activities, complete the table below.
| Subcontractor Name |
| Role or Service Provided |
| Certification Attached (Y/N) |
| Response Time (Hours) |
Certification I certify that the above information is accurate and complete.
ATTACHMENT D – SYSTEM EQUIVALENCY EVALUATION MATRIX
(To be completed only when offering an “or equal” system)
| Specification Category |
| IFB Requirement |
| Vendor Response |
| Meets Requirement? (Y/N) |
| Notes |
| System Type |
| Hologic Selenia Dimensions 3D equivalent, 2014 or newer |
| Tomosynthesis |
| Required |
| 2D FFDM Imaging |
| Required |
| C-View |
| Required |
| CAD |
| Required (ImageChecker + Citra) |
| Detector Type |
| Selenium TFT |
| Detector Size |
| 24 × 29 cm |
| Pixel Size |
| 0.070 mm |
| Spatial Resolution |
| 7.1 lp/mm |
| Generator |
| Constant potential HF |
| Tube |
| Tungsten bi-angular |
| Filters |
| Rhodium/Silver/Aluminum |
| Workstation Specs |
| CPU, RAM, GPU, OS |
| DICOM Services |
| MWL, MPPS, RDSR |
| PACS Compatibility |
| IQ-View |
| Required Accessories |
| All listed in specifications |
| Displays |
| 17” tech monitor; 21.3” 2MP clinical display |
| UPS |
| Minimum 5-minute backup |
| Refurbishment Documentation |
| All required documentation included |
| Installation Requirements |
| Installer qualifications met per Section 3.9 |
Certification I certify that this matrix accurately reflects the system offered.
Signature: ___________________________________ Date: ___________________________________
ATTACHMENT E – MANUFACTURING DATE VERIFICATION FORM
Vendor Name: __________________________________________ Equipment Offered: __________________________________________ A. Proof of Original Manufacturing Date Vendor must attach one or more of the following:
[ ] OEM-issued manufacture date statement [ ] FDA 2579 form [ ] OEM configuration/build report [ ] System log showing original build date B. Mixed-Component Disclosure Does the system contain components from multiple manufacturing years?
[ ] NO
[ ] YES — If yes, list each component and its manufacturing year below:
| Component Name |
| Year Manufactured |
| Replaced During Refurbishment? (Y/N) |
C. Certification I certify that the equipment offered meets the solicitation requirement of being 2014 or newer.