842312padot109577.pdf
PDF 690 KB Posted
- Attached to
- I-80 Bridge Piers Rehab
- Solicitation number
- 109577
- Issued by
- Northampton County, Pennsylvania
About this file
This is a Proposal Report for Project 109577, a Pennsylvania Department of Transportation (PennDOT) bridge rehabilitation project in Northumberland County. The project involves rehabilitation of State Route 80 bridges over State Route 254, including pier repair or construction, moment slab barrier construction, full-depth reconstruction of SR 254, guide rail installation, and miscellaneous construction work in Turbot Township. The scope encompasses work on both the eastbound and westbound directions of SR 80, as well as approximately 1.4 miles of SR 254. The bid package contains approximately 150 line items with quantities ranging from single units (lump sum mobilization, equipment package) to thousands of units (linear feet of pavement markings, concrete reinforcement bars, and temporary erosion control products). The project is scheduled for bid opening on October 22, 2026, with an anticipated Notice to Proceed on December 7, 2026, and required completion by October 17, 2028. No pre-bid meeting is specified in the documents. Prequalification is required for bidders.
The estimated project cost range is $5,000,000 to $7,499,999.99, representing a federally-funded construction project under FHWA oversight with 68% structure work. The contract requires compliance with multiple federal provisions including Buy America and Build America, Buy America Act requirements, as well as state provisions including Pennsylvania's Right-to-Know Law, Worker Protection and Investment Certification, and prevailing wage rates for heavy construction. Road User Liquidated Damages (RULD) will be assessed for lane closures, with varying hourly rates depending on time of day and direction (SR 80 EB or WB). Construction is restricted to specific periods, including no work during designated holidays, tree cutting restrictions from May 15 to July 31 to protect Indiana Bat habitat, and nighttime lane closure work between 6 p.m. and 5 a.m. Sunday through Friday. The project includes specialized work such as micropile installation, fiber-reinforced polymer wrapping of existing columns, infiltration testing for stormwater management, and comprehensive erosion and sediment control measures.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROPOSAL Report - Project 109577
September 2, 2026 12:41:50 PM Page 1 of 65
PROPOSAL REPORT
Project: 109577 Bid
Package: 1
Current Let: 10/22/2026 11:00:00 AM
Version: Current Addendum
Count: 0
District: 03 County: Northumberland
SR/SEC/
Group ID: 80/172/BRIDGE PRES SUBST
Description
I-80 Bridge Piers Rehab
September 2, 2026 12:41:50 PM Page 2 of 65
TABLE OF CONTENTS
BID PACKAGE SUMMARY
PROJECT ITEMS AND QUANTITIES
SPECIAL PROVISIONS
G50B - a00050 APPLICABLE DESIGNATED SPECIAL PROVISIONS (FEDERAL) G113B - a00113 CONTRACT PROVISIONS - RIGHT-TO-KNOW LAW C164A - a00164 CHANGES TO SPECIFICATIONS: SECTION 106 C171A - a00171 CHANGES TO SPECIFICATIONS: SECTIONS 313, 314, 360, 410, 412, and 413 C172A - a00172 CHANGES TO SPECIFICATIONS: SECTIONS 107, 871, 872, 875, and 876 G311A - a00311 ROAD USER LIQUIDATED DAMAGES (RULD) G1601A - a01601 E.E.O. COVERED AREA G2302A - a02302 Worker Protection and Investment N10550B - a10550 HEAVY CONSTRUCTION WAGE RATES S6012B - b06012 - SECTION 601.3(f) BACKFILLING TRENCH G30020E - r300020 EMERGENCY RESPONSE PROVISIONS G30240D - r300280 ADVANCE NOTICE OF TRAFFIC RESTRICTIONS G30260B - r300290 ASBESTOS ABATEMENT AND DEMOLITION/RENOVATION NOTIFICATION G30330B - r300330 PERMANENT SIGNS G30434D - r300434 CONSTRUCTION RESTRICTIONS S30061A - s0305160 SECTION 516 CONCRETE PAVEMENT PATCHING S30070D - s0306010 SECTION 601 PIPE CULVERTS S30073C - s0306011 SECTION 601.3(c) LAYING PIPE S30093E - s0306270 SECTION 627 TEMPORARY BARRIER S30094E - s0306280 SECTION 628 RESET TEMPORARY BARRIER S30931A - s0309311 SECTION 931 POST MOUNTED SIGNS, TYPE B S30935A - s0309351 SECTION 935 POST MOUNTED SIGNS, TYPE F S30117E - s0309620 SECTION 962 WATERBORNE PAVEMENT MARKINGS S30963A - s0309630 SECTION 963 PAVEMENT MARKING REMOVAL S30128E - s0310011 SECTION 1001 CEMENT CONCRETE STRUCTURES S30170G - s0311090 SECTION 1109 GUIDE RAIL AND METAL MEDIAN BARRIER I30010C - t0302010 ITEM 0201-0001 - CLEARING AND GRUBBING I30040E - t0302050 ITEM 0205-0364/0365 - SELECTED BORROW EXCAVATION ROCK, CLASS R-4/5
I6091L - t03060909 ITEM 0609-0009 EQUIPMENT PACKAGE I30310D - t0309010 ITEM 0901-0001 - MAINTENANCE AND PROTECTION OF TRAFFIC DURING
CONSTRUCTION
00 - t0310030 ITEM 5003-0000 - DOWEL HOLES, VARIABLE DEPTH, EPOXY ADHESIVE I30570H - t0310185 ITEM 1018-0050 - REMOVAL OF PORTION OF EXISTING BRIDGE I30595A - t0310190 ITEM 5019-0040 - PROTECTIVE COATING FOR REINFORCED CONCRETE
SURFACES (SUBSTRUCTURE) ETC
September 2, 2026 12:41:50 PM Page 3 of 65
00 - t0310510 ITEM 5051-0000 - DOWNSPOUTING, REMOVE AND REPLACE I19992A - t0319999 ITEM 1999-9999 - TRAINEES 00 - t0390001 ITEM 9000-0001 TEMPORARY STREAM DIVERSION 00 - t0390002 ITEM 9000-0002 FIBER REINFORCED POLYMER (FRP) WRAP OF EXISTING
COLUMNS
I31731A - t0390006 ITEM 9000-0006 - SELF-CONSOLIDATING CEMENT CONCRETE 00 - t0390051 ITEM 9000-0051 - WEIGHTED SEDIMENT FILTER TUBE, 9.5” DIAMETER 00 - t0390052 ITEM 9000-0052 18” TEMPORARY PIPE 00 - t0390100 ITEM 9000-0100 – MOMENT SLAB (AT-GRADE) WITH VERTICAL WALL BARRIER ... 56 00 - t0390101 ITEM 9000-0101 – MOMENT SLAB (AT-GRADE) WITH TOE WALL, ETC 00 - t0390102 ITEM 9000-0102 – SPECIAL CUSTOM INLET AND BOX WITH BICYCLE SAFE
GRATE
00 - t0390103 ITEM 9000-0103 – WOOD MAT FOR WETLAND CROSSING I32000A - t0390200 ITEM 9000-2000 HAZARDOUS MATERIAL/ASBESTOS INSPECTION AND
TESTING
I68C - t0390510 ITEM 9000-5101 ELECTRONIC TICKETING (E-TICKETING) FOR
CONSTRUCTION AGGREGATE
I70C - t0390513 ITEM 9000-5103 ELECTRONIC TICKETING (E-TICKETING) FOR
CONSTRUCTION CONCRETE
I2032D - t039203 ITEM 9203-0101 - TEMPORARY EXCAVATION SUPPORT AND PROTECTION
SYSTEM
September 2, 2026 12:41:50 PM Page 4 of 65
BID PACKAGE SUMMARY
Project: 109577 Bid Package: 1
Project Type: Standard Posted:
Federal Project Status: PENNDOT Oversight NHS State Type of Work: BRIDGE
Prequalification Required: Yes Pre-Bid Meeting: None
408 Version: 2026-1
Scheduled Let: 10/22/2026 11:00:00 AM Project Cost Range: $5,000,000.00 - $7,499,999.99 Anticipated NTP: 12/07/2026 Structure Work: 68.00%
Required Completion: 10/17/2028 DBE: 0% Wage Rates: Yes
Description:
The description and location of the project are as follows: rehabilitation of SR 80 bridges over SR 254, repair or construct piers, construct moment slab barriers, full-depth reconstruction of the SR 0254, guide rail, and other miscellaneous construction, as indicated on the approved drawings included in the bid package for STATE ROUTE 80, SECTION 172, in NORTHUMBERLAND COUNTY TURBOT TOWNSHIP from approximately 0.21 mile east SR 80 EB off ramp to SR 254 at segment 2144 offset 2386 to approximately 0.17 mile west of the SR 80 EB on ramp at segment 2150 offset 2344, approximately 0.20 mile west SR 80 WB off ramp to SR 254 at segment 2155 offset 0164 to approximately 0.22 mile east of the SR 80 WB on ramp at segment 2151 offset 0295, and for STATE ROUTE 254, from approximately 1 mile east of the intersection with School House Rd at segment 0090 offset 73 to approximately 0.30 mile west of intersection with Follmer Rd at segment 0140 offset 0142.
Additional Information:
This is an ECMS project. All Addenda will be electronically posted.The location of the public bid opening is the Commonwealth Keystone Building, 7th Floor, Contract Awards Room, 400 North Street, Harrisburg. Allow sufficient time before the bid opening to contact Contract Awards and be escorted to the 7th Floor Contract Awards Room. Contract Awards can be reached at 717-395-9754.
Due to recent changes in the Keystone Building, there is no longer a reception on the 5th Floor to greet and check-in visitors.
September 2, 2026 12:41:50 PM Page 5 of 65
PROJECT ITEMS AND QUANTITIES
Alt Item Work Class Code Unit Of
Measure Quantity Unit Price PDP Spec
Prov Add Action
0201-0001 A Lump Sum 1.0000 N Std
CLEARING AND GRUBBING
0203-0001 C Cubic Yard 566.0000 N
CLASS 1 EXCAVATION
0203-0006 G4 Linear Foot 40.0000 N
SAW CUTTING
0204-0001 C1, H Cubic Yard 10.0000 N
CLASS 2 EXCAVATION
0204-0100 C1, S1, T1 Cubic Yard 3,345.0000 N
CLASS 3 EXCAVATION
0204-0150 C1, H, S Cubic Yard 4.0000 N
CLASS 4 EXCAVATION
0205-0281 C1 Cubic Yard 90.0000 N
SELECTED BORROW EXCAVATION, COARSE AGGREGATE, NO. 1
0205-0364 C1 Ton 13.0000 N Std
SELECTED BORROW EXCAVATION ROCK, CLASS R-4
0205-0365 C1 Ton 496.0000 N Std
SELECTED BORROW EXCAVATION ROCK, CLASS R-5
0212-0001 C3, H, M2 Linear Foot 787.0000 N
GEOTEXTILE, CLASS 1
0212-0014 C3, H, M2 Square Yard 832.0000 N
GEOTEXTILE, CLASS 4, TYPE A
0350-0121 C, E Ton 331.0000 N
SUBBASE (NO. 2A)
0516-2056 G1 Square Yard 499.0000 N
CONCRETE PAVEMENT PATCHING, TYPE C, 12" DEPTH
0601-7014 H Linear Foot 118.0000 N
18" REINFORCED CONCRETE PIPE, TYPE A, 15' - 2' FILL, 100 YEAR DESIGN LIFE
0605-2620 K Each 1.0000 N
TYPE D-W ENDWALL
0605-2731 K Set 3.0000 N
TYPE M CONCRETE TOP UNIT AND BICYCLE SAFE GRATE
0605-2850 K Each 2.0000 N
STANDARD INLET BOX, HEIGHT < /= 10'
September 2, 2026 12:41:50 PM Page 6 of 65
0605-2866 K Each 1.0000 N
TYPE 7 INLET BOX, HEIGHT < /= 10'
0608-0001 X Lump Sum 1.0000 N
MOBILIZATION
0609-0004 X Lump Sum 1.0000 N
INSPECTOR'S FIELD OFFICE AND INSPECTION FACILITIES, TYPE C
0609-0009 X Lump Sum 1.0000 N Std
EQUIPMENT PACKAGE
0610-7001 H2 Linear Foot 787.0000 N
4" PAVEMENT BASE DRAIN
0619-0459 J1, J3 Each 2.0000 N
PERMANENT IMPACT ATTENUATING DEVICE, TYPE II, TEST LEVEL 3, TANGENT (MASH)
0620-0503 C1, J Linear Foot 688.0000 N
REMOVE EXISTING GUIDE RAIL (CONTRACTOR'S PROPERTY)
0620-1600 J Linear Foot 448.0000 N
TYPE 31-S GUIDE RAIL
0620-2010 J Each 4.0000 N
THRIE-BEAM GUIDE RAIL TO CONCRETE BRIDGE BARRIER TRANSITION WITHOUT CURB
0627-3090 J1 Linear Foot 580.0000 N
TEMPORARY BARRIER, TEST LEVEL 3, BARRIER DEFLECTION DISTANCE < /=9'
0628-3090 J1 Linear Foot 400.0000 N
RESET TEMPORARY BARRIER, TEST LEVEL 3, BARRIER DEFLECTION DISTANCE < /=9'
0680-0121 K2, S1 Square Yard 266.0000 N
MEMBRANE WATERPROOFING SYSTEM INSTALLED ON OTHER SURFACES
0686-0060 X Lump Sum 1.0000 N
CONSTRUCTION SURVEYING, TYPE D, MODIFIED
0689-0003 X Lump Sum 1.0000 N
CPM SCHEDULE
0696-0610 J1 Each 2.0000 N
TEMPORARY IMPACT ATTENUATING DEVICE, TYPE V (STANDARD), TEST LEVEL 3
0697-0610 J1 Each 2.0000 N
RESET TEMPORARY IMPACT ATTENUATING DEVICE, TYPE V (STANDARD), TEST LEVEL 3
0698-0001 S2 Each 960.0000 N
POST-INSTALLED CONCRETE ANCHORS, PERMANENT
0802-0001 C1, M Cubic Yard 140.0000 N
TOPSOIL FURNISHED AND PLACED
0804-0037 M3 Pound 35.0000 N
SEEDING AND SOIL SUPPLEMENTS - FORMULA C CONSERVATION MIX
September 2, 2026 12:41:50 PM Page 7 of 65
0804-0038 M3 Pound 93.0000 N
SEEDING AND SOIL SUPPLEMENTS - FORMULA L CLEAR ZONE MIX
0804-0043 M3 Pound 6.0000 N
SEEDING - FORMULA T TEMPORARY GRASS MIX
0804-0044 M3 Pound 6.0000 N
SEEDING AND SOIL SUPPLEMENTS - FORMULA W WETLAND CONSERVATION MIX
0804-0051 ZZ Acre 1.0000 N
MOWING
0804-0060 X Dollar 200.0000 $1.00 Y
SOIL TESTING
0805-0022 M3 Ton 1.0000 N
MULCHING - STRAW
0805-0050 M3 Square Yard 466.0000 N
MULCH CONTROL NETTING
0806-0113 M2 Square Yard 4,659.0000 N
TEMPORARY SHORT-TERM, ROLLED EROSION CONTROL PRODUCT, TYPE 2D
0806-0140 M2 Square Yard 175.0000 N
PERMANENT ROLLED EROSION CONTROL PRODUCT, TYPE 5A
0811-0003 J2, M Linear Foot 52.0000 N
TEMPORARY PROTECTIVE FENCE
0849-0010 C1 Each 1.0000 N
ROCK CONSTRUCTION ENTRANCE
0855-0003 M2 Each 3.0000 N
PUMPED WATER FILTER BAG
0855-0004 M2 Each 3.0000 N
REPLACEMENT PUMPED WATER FILTER BAG
0860-0000 M2 Each 1.0000 N
INLET FILTER BAG FOR TYPE M INLET
0867-0012 M2 Linear Foot 1,542.0000 N
COMPOST FILTER SOCK, 12" DIAMETER
0867-0022 M2 Linear Foot 161.0000 N
COMPOST FILTER SOCK, 24" DIAMETER
0901-0001 Q Lump Sum 1.0000 N Std
MAINTENANCE AND PROTECTION OF TRAFFIC DURING CONSTRUCTION
0901-0240 Q, R Square Foot 100.0000 N
ADDITIONAL TRAFFIC CONTROL SIGNS
0901-0320 O Linear Foot 23,938.0000 N
September 2, 2026 12:41:50 PM Page 8 of 65
4" STANDARD PAVEMENT MARKINGS, PAINT & BEADS, YELLOW
0901-0330 O Linear Foot 13,629.0000 N
4" STANDARD PAVEMENT MARKINGS, PAINT & BEADS, WHITE
0901-0331 O Linear Foot 3,347.0000 N
6" STANDARD PAVEMENT MARKINGS, PAINT & BEADS, WHITE
0901-0334 O Linear Foot 621.0000 N
24" STANDARD PAVEMENT MARKINGS, PAINT & BEADS, WHITE
0931-0001 R Square Foot 53.0000 N
POST MOUNTED SIGNS, TYPE B
0935-0001 R Square Foot 28.0000 N
POST MOUNTED SIGNS, TYPE F
0960-0021 O2 Linear Foot 150.0000 N
24" WHITE HOT THERMOPLASTIC PAVEMENT MARKINGS
0960-0230 O2 Each 2.0000 N
WHITE HOT THERMOPLASTIC LEGEND, "WRONG WAY ARROW", 23' - 0"
0962-1000 O Linear Foot 9,410.0000 N
4" WHITE WATERBORNE PAVEMENT MARKINGS
0962-1001 O Linear Foot 1,672.0000 N
6" WHITE WATERBORNE PAVEMENT MARKINGS
0962-1005 O Linear Foot 16,268.0000 N
4" YELLOW WATERBORNE PAVEMENT MARKINGS
0963-0001 O2, O3 Square Foot 117.0000 N
PAVEMENT MARKING REMOVAL
0963-0004 O2, O3 Linear Foot 22,384.0000 N
4" PAVEMENT MARKING REMOVAL
0963-0006 O2, O3 Linear Foot 3,346.0000 N
6" PAVEMENT MARKING REMOVAL
1001-0611 T7 Linear Foot 66.0000 N
6" STRUCTURE FOUNDATION DRAIN
1001-1120 S2 Cubic Yard 955.0000 N
CLASS A CEMENT CONCRETE
1002-0052 S7 Pound 114,362.0000 N
REINFORCEMENT BARS, EPOXY COATED
5003-0000 S2 Each 194.0000 N Proj
DOWEL HOLES, VARIABLE DEPTH (EPOXY ADHESIVE)
1007-0200 X Each 6.0000 N
MICROPILES VERIFICATION LOAD TEST
September 2, 2026 12:41:50 PM Page 9 of 65
1007-0220 X Lump Sum 1.0000 N
MICROPILES MOBILIZATION
1007-0230 K1 Cubic Foot 2,344.0000 N
MICROPILES GROUT
1007-0350 C6, U Linear Foot 2,742.0000 N
MICROPILES 9 5/8" DIAMETER, PLAIN STEEL
1018-0050 T1 Lump Sum 1.0000 N Std
REMOVAL OF PORTION OF EXISTING BRIDGE
5019-0040 K2 Square Yard 1,761.0000 N Std
PROTECTIVE COATING FOR REINFORCED CONCRETE SURFACES (PENETRATING SEALERS, REINFORCED
CONCRETE SUBSTRUCTURE SURFACES) (100% SILANE)
1050-0040 T3 Pound 49,372.0000 N
FABRICATED STRUCTURAL STEEL, GALVANIZED
1050-0089 T8 Each 2,127.0000 N
SHEAR CONNECTORS
5051-0000 T7 Linear Foot 40.0000 N Proj
DOWNSPOUTING
1072-0200 X Lump Sum 1.0000 N
WASTE MANAGEMENT
1072-0300 V2 Lump Sum 1.0000 N
WORKER HEALTH AND SAFETY
1999-9999 Z Hour 1,000.0000 N Std
TRAINEES
9000-0001 C1, H Linear Foot 646.0000 N Proj
TEMPORARY STREAM DIVERSION
9000-0002 X Square Foot 4,027.0000 N Proj
FIBER REINFORCED POLYMER (FRP) WRAP OF EXISTING COLUMNS
9000-0006 S2 Cubic Yard 130.0000 N Std
SELF-CONSOLIDATING CEMENT CONCRETE
9000-0051 M2 Linear Foot 36.0000 N Proj
WEIGHTED SEDIMENT FILTER TUBE, 9.5" DIAMETER
9000-0052 H Linear Foot 30.0000 N Proj
18" TEMPORARY PIPE
9000-0100 J1 Linear Foot 113.0000 N Proj
MOMENT SLAB (AT-GRADE) WITH VERTICAL WALL BARRIER
9000-0101 J1 Linear Foot 111.0000 N Proj
MOMENT SLAB (AT-GRADE) WITH TOE WALL AND CAST IN PLACE VERTICAL WALL BARRIER
9000-0102 K Each 1.0000 N Proj
SPECIAL CUSTOM INLET AND BOX WITH BICYCLE SAFE GRATE
September 2, 2026 12:41:50 PM Page 10 of 65
9000-0103 C1, M Square Foot 4,757.0000 N Proj
WOOD MAT FOR WETLAND CROSSING
9000-2000 B1, C1 Dollar 10,000.0000 $1.00 Y Std
HAZARDOUS MATERIAL/ASBESTOS INSPECTION AND TESTING
9000-5101 X Lump Sum 1.0000 N Std
ELECTRONIC TICKETING (E-TICKETING) FOR CONSTRUCTION AGGREGATE
9000-5103 X Lump Sum 1.0000 N Std
ELECTRONIC TICKETING (E-TICKETING) FOR CONSTRUCTION CONCRETE
9203-0101 C1, S5 Lump Sum 1.0000 N Std
TEMPORARY EXCAVATION SUPPORT AND PROTECTION SYSTEM
September 2, 2026 12:41:50 PM Page 11 of 65
SPECIAL PROVISIONS
Special Provision: G50B - a00050 APPLICABLE DESIGNATED SPECIAL PROVISIONS (FEDERAL) Addendum:
Action:
Item(s) Associated:
Header:
APPLICABLE DESIGNATED SPECIAL PROVISIONS (FEDERAL)
Provision Body:
APPLICABLE DESIGNATED SPECIAL PROVISIONS. The following Designated Special Provisions are found in Appendix C and apply to this bid proposal.
DSP7. Disadvantaged Business Enterprise (DBE) Requirements for Federally-funded Construction Projects.
DSP8. F.A.R. - Required Contract Provisions Federal-Aid Construction Contracts FHWA-1273 (Revised October 23, 2023). Also attached to the Proposal/Contract.
DSP9. Special Supplement - Anti-Pollution Measures - August 26, 1999.
DSP12. Executive Order 11246, with Appendix A and B.
DSP13. Buy America.
DSP15. Commonwealth Standard Terms and Conditions.
DSP16. Lobbying Certification Form. (Form is located in ECMS File Cabinet and must be completed and uploaded to the Contractor Checklist in ECMS).
DSP17. Federal Audit Clause.
DSP19. The United States Department of Transportation (USDOT) Standard Title VI/Non-Discrimination Assurances.
DSP20. FAR 52.240-1 Prohibition on Unmanned Aircraft Systems Manufactured or Assembled by American Security Drone Act- Covered Foreign Entities.
Project Specific Details:
Special Provision: G113B - a00113 CONTRACT PROVISIONS - RIGHT-TO-KNOW LAW Addendum:
CONTRACT PROVISIONS - RIGHT TO KNOW LAW
Provision Body:
September 2, 2026 12:41:50 PM Page 12 of 65
I. Contract Provisions – Right to Know Law 8-K-1532
a. The Pennsylvania Right-to-Know Law (RTKL), 65 P.S. §§ 67.101-3104, applies to this Contract.
b. If the Department needs assistance in any matter arising out of the RTKL related to this Contract, the Department will notify the Contractor using the legal contact information provided in this Contract. The Contractor, at any time, may designate a different contact for such purpose upon reasonable prior written notice to the Department.
c. Upon written notification from the Department that it requires assistance in responding to a request under the RTKL for information related to this Contract that may be in the Contractor’s possession, constituting, or alleged to constitute, a public record in accordance with the RTKL (“Requested Information”), the Contractor will:
1. Provide the Department, within 10 calendar days after receipt of written notification, access to, and copies of, any document or information in the Contractor’s possession arising out of this Contract that the Department reasonably believes is Requested Information and may be a public record under the RTKL; and
2. Provide such other assistance as the Department may reasonably request, in order to comply with the RTKL with respect to this Contract.
d. If the Contractor considers the Requested Information to include a request for a Trade Secret or Confidential Proprietary Information, as those terms are defined by the RTKL, or other information that the Contractor considers exempt from production under the RTKL, notify the Department and provide, within 7 calendar days of receiving the written notification, a written statement signed by a representative of the Contractor explaining why the requested material is exempt from public disclosure under the RTKL.
e. The Department will rely upon the written statement from the Contractor in denying a RTKL request for the Requested Information unless the Department determines that the Requested Information is clearly not protected from disclosure under the RTKL. Should the Department determine that the Requested Information is clearly not exempt from disclosure, provide the Requested Information within 7 calendar days of receipt of written notification of the Department’s determination.
f. Failing to provide the Requested Information within the time period required by these provisions, indemnify and hold the Department harmless for any damages, penalties, costs, detriment or harm that the Department may incur as a result of this failure, including any statutory damages assessed against the Department.
g. The Department will reimburse the Contractor for any costs associated with complying with these provisions only to the extent allowed under the fee schedule established by the Office of Open Records or as otherwise provided by the RTKL if the fee schedule is inapplicable.
h. The Contractor may file a legal challenge to any Department decision to release a record to the public with the Office of Open Records, or in the Pennsylvania Courts, however, indemnify the Department for any legal expenses incurred by the Department as a result of such a challenge and hold the Department harmless for any damages, penalties, costs, detriment or harm that the Department may incur as a result of the failure, including any statutory damages assessed against the Department, regardless of the outcome of such legal challenge. As between the parties, agree to waive all rights or remedies that may be available as a result of the Department’s disclosure of Requested information pursuant to the RTKL.
i. The Contractor’s duties relating to the RTKL are continuing duties that survive the expiration of this Contract and continue as long as the Requested Information remains in the Contractor's possession.
Special Provision: C164A - a00164 CHANGES TO SPECIFICATIONS: SECTION 106
September 2, 2026 12:41:50 PM Page 13 of 65
Header:
CHANGES TO SPECIFICATIONS: SECTION 106
Provision Body:
SECTION 106—CONTROL OF MATERIAL
106.10(a) Buy America Provisions. Revise last paragraph to read as follows:
Products manufactured of foreign steel or iron materials may be used, provided the cumulative cost of such products as they are delivered to the project does not exceed 0.1% of the total contract amount, or $2,500, whichever is greater.
Add 106.11 BUILD AMERICA, BUY AMERICA ACT PROVISIONS.
106.11 BUILD AMERICA, BUY AMERICA ACT PROVISIONS—
(a) Build America, Buy America Act. The Federal Bipartisan Infrastructure Law (Public Law 117-58) includes the Build America, Buy America Act that requires all iron, steel, manufactured products, and construction materials used to be produced in the United States.
The term produced in the United States defined as:
1. Iron or Steel Products. All manufacturing processes from the initial melting stage through the application of coatings occurred in the United States according to Section 106.10(a).
2. Manufactured Product. Final assembly of all manufactured products permanently incorporated into the project must be manufactured in the United States.
2.a A manufactured product, not predominantly steel or iron, is defined as an article, material, or supply that has been processed into a specific form and shape, or combined with other articles, materials, or supplies to create a product with different properties than the individual articles, materials, or supplies.
2.b Predominantly steel or iron is defined as greater than or equal to 50 percent of the total cost of the manufactured product.
2.c Manufactured products that are predominantly steel or iron must comply with Buy America provisions according to Section 106.10(a).
2.d If an article, material, or supply meets this definition but could also be classified as an excluded material or other product category, that article, material, or supply is not a manufactured product.
2.e Mixtures of excluded materials delivered to a work site without final form for incorporation into a project are also not manufactured products.
2.f Manufactured products where the final assembly did not occur in the United States may be used, provided the cumulative cost of such manufactured products is no more than the lesser of $1 million or 5% of total applicable costs for the project.
3. Construction Materials.
3.a All manufacturing processes for construction materials occurred in the United States.
3.b Construction materials includes an article, material, or supply that is or consists primarily of:
non-ferrous metals, plastic and polymer-based products including polyvinylchloride, composite building materials, and polymers used in fiber optic cables, glass including optic glass, lumber, or drywall
September 2, 2026 12:41:50 PM Page 14 of 65
Items that consist of two or more of the listed materials that have been combined together through a manufacturing process, and items that include at least one of the listed materials combined with a material that is not listed through a manufacturing process, should be treated as manufactured products, rather than as construction materials.
3.c Limitation with Respect to Aggregates. Shall not include cement and cementitious materials, aggregates such as stone, sand, or gravel, or aggregate binding agents or additives.
3.d Construction materials where all manufacturing processes did not occur in the United States may be used, provided the cumulative cost of such construction materials is no more than the lesser of $1 million of 5% of total applicable costs for the project.
Special Provision: C171A - a00171 CHANGES TO SPECIFICATIONS: SECTIONS 313, 314, 360, 410, 412, and 413
Addendum:
CHANGES TO SPECIFICATIONS: SECTIONS 313, 314, 360, 410, 412, and 413
Provision Body:
SECTION 313—SUPERPAVE ASPHALT MIXTURE DESIGN, STANDARD CONSTRUCTION, BASE COURSE
Section 313.3(m) Tests for Depth. Revise to read as follows:
(m) Tests for Depth.
(m) Tests for Depth. Replace with the following:
Control the loose depth of each layer to construct the base course to the compacted depth indicated and within the specified tolerance. On the top lift and in the presence of the Inspector, drill full-depth cores at one random location selected by the Inspector according to PTM No. 1 in each 3,000 square yards of completed base course and at other locations the Inspector suspects are deficient. After the Inspector completes depth measurements, backfill, compact, and seal core holes with the mixture used to construct the course.
The Inspector will measure the full-depth cores according to PTM No. 737. Pavement deficient in depth by 1/2 inch or more and that cannot be satisfactorily corrected is defective. Immediately delineate the limits of pavement deficient in depth from the core location by proceeding longitudinally, forward and backward, obtaining additional pavement cores every 50 feet until the depth is less than 1/2 inch deficient of the design depth. The defective course will be the full width of the affected lane.
SECTION 314—SUPERPAVE ASPHALT MIXTURE DESIGN, STANDARD CONSTRUCTION, ASPHALT RICH BASE COURSE
Section 314.3(m) Tests for Depth. Revise to read as follows:
(m) Tests for Depth.
(m) Tests for Depth. Replace with the following:
Control the loose depth of each layer to construct the ARBC to the compacted depth indicated and within the specified tolerance. In the presence of the Inspector, drill full-depth cores at one random location selected by the Inspector according to PTM No. 1 in each 3,000 square yards of completed ARBC and at other locations the Inspector suspects are deficient. After the Inspector completes depth measurements, backfill, compact, and seal core holes with ARBC.
September 2, 2026 12:41:50 PM Page 15 of 65
The Inspector will measure the full-depth cores according to PTM No. 737. Pavement deficient in depth by 1/2 inch or more and that cannot be satisfactorily corrected is defective. Immediately delineate the limits of pavement deficient in depth from the core location by proceeding longitudinally, forward and backward, obtaining additional pavement cores every 50 feet until the depth is less than 1/2 inch deficient of the design depth. The defective course will be the full width of the affected lane.
SECTION 360—ASPHALT TREATED PERMEABLE BASE COURSE
Section 360.2(e)3. Production. Revise to read as follows:
3. Production. During the first day of production, take at least three asphalt content and gradation tests to verify the mixture conforms to the JMF. After the first day, perform tests for asphalt content and aggregate gradation according to the QC Plan and PTM No. 1. Produce ATPBC conforming to the gradation requirements in Table A and with an asphalt content within 0.8% of the JMF (n=1). Ensure the aggregate is uniformly coated with asphalt and no runoff of excess asphalt is observed.
Section 360.3(m). Tests for Depth. Revise to read as follows:
(m) Tests for Depth: Binder and Wearing Courses. Replace with the following:
Carefully dig or drill one random 6-inch diameter test hole selected by the Representative according to PTM No. 1 to the full depth of the ATPBC for each 3,000 square yards, or less, of completed base course. The Representative may require additional test holes in areas the Representative suspects are deficient in depth. The Representative will measure the depth of the base course. Using material acceptable to the Representative, backfill the test holes and compact the material to fill the test hole flush with the completed base course.
ATPBC deficient in depth by 1/2 inch or more is defective. Immediately delineate the limits of ATPBC deficient in depth from the location by proceeding longitudinally, forward and backward, obtaining additional test holes every 50 feet until the depth is less than 1/2 inch deficient of the indicated depth. The defective course will be the full width of the affected lane.
SECTION 410—SUPERPAVE MIXTURE DESIGN, STANDARD AND RPS CONSTRUCTION OF PLANT-MIXED ASPHALT FINE-
GRADED COURSES
Section 410.3. CONSTRUCTION. Revise to read as follows:
410.3 CONSTRUCTION—Section 413.3 using the test procedures, limits, and tolerances for a 9.5 mm nominal maximum aggregate size mixture except where procedures, limits and tolerances are specifically indicated for a 9.5 mm fine-graded nominal maximum aggregate size mixture and as modified as follows:
Revise Table G to include 9.5 mm Fine Grade Wearing Course as follows:
TABLE G
Mixture Minimum Indicated Compacted Depths
Mixture Minimum Depth
9.5 mm Fine Grade Wearing Course 1 inch SECTION 412—SUPERPAVE MIXTURE DESIGN, CONSTRUCTION OF PLANT-MIXED 6.3 MM ASPHALT OVERLAY COURSES
Section 412.3(a)2. Preplacement Meeting. Revise to read as follows:
2. Preplacement Meeting. At least 2 weeks before placing asphalt paving mixtures, schedule an asphalt preplacement meeting with the Representative to review at a minimum the specification, paving operation QC Plan, sequence of paving operations, asphalt mixture temperature checks, mixture acceptance, density acceptance and the care and custody of asphalt acceptance samples.
Section 412.3(h)1.a. Placing. Revise to read as follows:
1.a Placing. Unless otherwise allowed, deliver, place, and compact 6.3 mm paving mixtures during daylight hours. Ensure the mixture does not contain lumps of cold material. Deliver and place 6.3 mm paving mixtures at the laying temperatures specified in Table B.
Material placed outside the temperature limits as specified in Table B is defective.
September 2, 2026 12:41:50 PM Page 16 of 65
Utilize a Material Transfer Vehicle (MTV) as specified in Section 108.05(c)5 for 6.3 mm paving mixtures unless otherwise approved by the Representative.
Section 412.4(a)4.b. Dispute Resolution. Revise TABLE H to read as follows:
TABLE H
Dispute Resolution Retest Cost Table
Test Method
Mixture Acceptance Retest Cost if Retest Results Indicate
100% Pay Factor(s) for Full Lots (n > 3)* or Single Sample (n=1) Requirements in Table B were met for Partial Lots (n < 3)**
Mixture Acceptance Retest Cost if Retest Results Indicate
< 100% Pay Factor(s) for Full Lots (n > 3)* or Single Sample (n=1) Requirements in Table B were not met for Partial Lots (n < 3)**
PTM No.
702/739 $900 $3,500
PTM No. 757 $500 $2,000
* For full lots (n ≥ 3) where the original test results indicated a defective lot, only the pay factor(s) where original test results indicated a defective lot for asphalt content or percent passing the 75 μm (No. 200) sieve will be utilized to determine the retest cost.
** For partial lots (n < 3) where the original test results indicated a pay parameter (asphalt content, percent passing the 75 µm (No. 200) sieve, or both) did not meet the Single Sample (n = 1) requirements in Table B, only the pay parameter(s) that did not meet the Single Sample (n =1) requirements will be utilized to determine the retest cost.
SECTION 413—SUPERPAVE MIXTURE DESIGN, STANDARD AND RPS CONSTRUCTION OF PLANT-MIXED ASPHALT
COURSES WITH PERCENT WITHIN LIMITS AND LTS TESTING (PWS-LTS)
Section 413.2(e)1. Recycled Asphalt Material. Revise to read as follows:
1. Virgin Material Mixtures. Size, uniformly grade, and combine aggregate fractions, asphalt binder, and either WMA Technology additive(s) or modifier(s) in proportions to produce a JMF that conforms to the material, gradation, and volumetric Superpave Asphalt Mixture Design requirements according to Bulletin 27, Chapter 2A. Produce an asphalt mixture for the specified nominal maximum aggregate size and design ESALs except as procedurally modified by the WMA Technology Manufacturer Technical Representative (Technical Representative) to address laboratory procedures when preparing, compacting and testing asphalt mixtures to achieve a uniform blend. Special additive(s) or modifier(s) need not be used if mixture temperature, workability, and compaction can be achieved solely through plant mechanical modification to produce foamed asphalt. Do not incorporate the WMA Technology additive, modifier or process during the volumetric asphalt mixture design process, so that the JMF volumetrics and material percentages are based on a mixture with no WMA Technology. Only use the WMA Technology additive, modifier or process to evaluate results from moisture susceptibility testing during the mix design process. Develop an asphalt mixture JMF, then incorporate the WMA Technology additive, modifier, or process into that JMF during production. Create an asphalt JMF cover sheet (Form TR-448A) for approval containing the WMA Technology used, additive dosage rate or percent water added for foaming, material code, and the TSR data from the moisture susceptibility testing.
Submit a copy of each completed JMF, signed by a certified Asphalt Level 2 plant technician, to the DME/DMM at least 3 weeks before the planned start of mixture production. Include a list of all material sources and the asphalt mixture producer in the JMF.
Provide the calibration factors (Cf and 200 Cf) according to PTM No. 757 with the JMF. Do not start mixture production until after the DME/DMM reviews the JMF.
Submit a new JMF with a change in material sources or if a new JMF is necessary to produce a mixture conforming to this specification.
No additional revisions were made to Section 413.2(e)1.
Section 413.2(e)1.d.5. Volumetric Analysis of Compacted Specimens. Revise TABLE A as follows:
September 2, 2026 12:41:50 PM Page 17 of 65
TABLE A
Job-Mix Formula Composition Tolerance Requirements of the Completed Mix
Single Sample (n=1) Multiple
Samples (n > 3)
Gradation Passing 12.5 mm (1/2 inch) and Larger Sieves +8% +6% Passing 9.5 mm (3/8 inch) to 150 µm (No. 100) Sieves (Inclusive) +6% +4%
Passing 75 µm (No. 200) Sieve +3.0% +2.0% Asphalt Content
19.0 mm Asphalt mixtures and smaller +0.7% +0.4%
25.0 mm Asphalt mixtures and larger +0.8% +0.5%
Temperature of Mixture (F)
Class of Material Type of Material
Chemical, Organic, Foaming Additives
Minimum*
Mechanical Foaming Equipment/Process
Minimum* Maximum*
PG 58S-28 Asphalt Binder 215 230 310 PG 64S-22 Asphalt Binder 220 240 320 PG 64E-22 Asphalt Binder 240 260 330
All other Binders Asphalt Binder
The higher of 215 or the minimum temp.
specified in Bulletin 25 minus 45F
The higher of 230 or the minimum temp.
specified in Bulletin 25 minus 30F
As specified in Bulletin
* Outline in the Producer QC Plan and follow more restrictive temperature requirements provided by the WMA technology manufacturer or Technical Representative(s) for production and placement of the mixture. Determine the SGC compaction temperature for the production QC which yields the same target air voids as the designed JMF. Include the SGC compaction temperature in the Producer QC Plan. Compact the completed mixture in the SGC for QC volumetric analysis at the SGC compaction temperature according to the guidelines provided by the Technical Representative.
Section 413.2(i)2. Certification Acceptance. Revise to read as follows:
2. Certification Acceptance. Acceptance by certification is appropriate for the following mixtures, conditions, or applications:
Scratch courses, leveling courses less than 2-inch depth and driveway adjustments.
Mixtures used by Department maintenance forces.
Mixtures purchased by local or municipal governments.
Mixtures placed in quantities not exceeding 500 tons in a continuous placement operation unless otherwise directed by the Representative.
Mixtures used for parking lots.
All 4.75 mm NMAS asphalt mixtures.
Other mixtures, conditions, or applications as approved by the Representative.
2.a General. Obtain certification from the mixture Producer. Use all QC tests during mixture production as acceptance tests. Certify mixtures using Form CS-4171B. Include, or attach, the QC test results on the form. Provide the form to the Inspector-in-Charge within 1 working day after completing the QC tests. Certify mixtures as specified in Section 106.03(b)3 and the requirements below.
September 2, 2026 12:41:50 PM Page 18 of 65
2.b Certification of Mixture. Certify each mixture daily if QC test results conform to the single sample and multiple sample JMF production tolerances of Table A. The acceptance values will be:
Asphalt Content.
Percent Passing the 2.36 mm (No. 8) sieve (not applicable for 4.75 mm NMAS asphalt mixtures).
Percent Passing the 75 µm (No. 200) sieve.
If using printed ticket results in place of laboratory test results for asphalt content, certify that at least 90% of each day’s printed ticket results for asphalt content are within 0.2 percentage points of the JMF.
If the mixture does not conform to the above requirements, do not certify the mixture. Instead, provide all QC test results to the Inspector-in-Charge. If using printed ticket results for asphalt content, provide the percentage of daily printed ticket results within 0.2 percentage points of the JMF to the Inspector-in-Charge. Payment will be determined according to Table H based on the QC test results.
If a day’s production is interrupted by corrective action, material produced after the corrective action may be certified if QC test results conform to production tolerances.
2.c Maintaining Approval to Certify Mixtures. The Department may suspend a plant’s approval to certify mixtures if QC is not performed according to the Producer QC Plan, mixtures are not produced according to Bulletin 27, a mixture cannot be certified on 2 consecutive production days, or as described below.
The Department may take IA samples of the completed mixture at the plant. In the presence of the Department, test the IA samples for asphalt content and gradation according to the test methods indicated in the Producer QC Plan. Take immediate corrective actions if the mixture does not conform to Table A.
The Department may take QA samples of the completed mixture at the plant or on the roadway directly from the uncompacted mixture placed by the paving equipment specified in Section 413.3(e). The Department will test QA samples according to PTM No. 757 or PTM No. 702, Modified Method D, if previously identified problematic aggregates are used in the mixture, for conformance to Table A. If the results of the QA samples do not comply with Table A, review the Producer QC Plan and the QC test results that followed the QA samples for conformance to Table A. If QC results do not conform to Table A, perform the corrective actions necessary to provide a mixture conforming to Table A.
After completing corrective actions or the sample review, the Department will perform an on-site evaluation of the Producer’s plant operation and QC and then take a sample of the completed mixture at the plant. In the presence of the Representative, test the sample.
If the sample does not comply with Table A, the Department will suspend certification. Immediately suspend shipping mixtures accepted by certification to the project.
After testing verifies that the produced mixture conforms to Tables A and B and with the Representative present, conduct JMF verification according to the Producer QC Plan. After successfully completing JMF verification, resume both certification and shipping mixtures accepted by certification to the project.
Section 413.3(a)2. Preplacement Meeting. Revise to read as follows:
2. Preplacement Meeting. At least 2 weeks before placing asphalt paving mixtures, schedule an asphalt preplacement meeting with the Representative to review at a minimum the specification, paving operation QC Plan, sequence of paving operations, asphalt mixture temperature checks, mixture acceptance, density acceptance and the care and custody of asphalt acceptance samples.
Section 413.3(d). Hauling Equipment. Revise to read as follows:
(d) Hauling Equipment. Haul the mixtures in tightly sealed vehicles that do not contain petroleum oils, solvents, or other materials that adversely affect asphalt mixture. Provide covers of sufficient size and quality to protect the entire load under all conditions.
Maintain the proper and uniform placement temperature as specified in Section 413.3(h)1. Provide insulation on all sides of the truck body, a double-walled truck body, or a heated truck body when the air temperature is below 50F from October 1 to April 30. Provide a 3/8-inch diameter hole near the center and approximately two-thirds the distance down from the top of the vehicular box, on both sides, to allow for asphalt mixture temperature checks. If trucks cannot be provided with these holes, provide the Representative with two infrared temperature devices along with documentation that the devices were verified annually through an independent verification service or with a blackbody calibration block before paving for asphalt mixture temperature checks.
Section 413.3(f). Rollers. Revise to read as follows:
September 2, 2026 12:41:50 PM Page 19 of 65
(f) Rollers. Use steel wheel, pneumatic tire, vibratory, or oscillating rollers as specified in Sections 108.05(c)3.a, 3.b, 3.c, 3.e, 3.f, 3.h, or (c)4. Operate rollers according to manufacturer's recommendations. Use vibratory and oscillating rollers with separate controls for frequency and amplitude.
Section 413.3(h)1.a. Placing. Revise to read as follows:
1.a Placing. Unless otherwise allowed or indicated, deliver, place, and compact asphalt paving mixtures during daylight hours.
Ensure the mixture does not contain lumps of cold material. Deliver and place mixtures at the laying temperatures specified in Table A for the type and class of material used. Do not incorporate any material delivered outside the temperature limits as specified in Table A. Material placed outside the temperature limits as specified in Table A is defective.
Utilize a Material Transfer Vehicle (MTV) as specified in Section 108.05(c)5 for RPS pavements unless otherwise approved by the Representative.
Section 413.3(h)1.e. Safety Edge. Revise to read as follows:
1.e. Safety Edge. Construct the Safety Edge as the standard edge treatment on the outside edge of asphalt pavements and shoulders. Use the Safety Edge for both wearing and binder courses with a depth of 1.5 inches or greater. Do not place the Safety Edge at total depths greater than 5 inches. The Safety Edge is not required where curb or sidewalk are encountered or where the face of guiderail is directly over the edge of pavements. Do not place the Safety Edge for base, leveling, or scratch courses.
Construct the Safety Edge with the same material used to construct the roadway course being placed or, if specified, the paved shoulders. Attach a device to the paver to confine material at the end gate and extrude the asphalt material in a wedge shape. Use an adjustable device that allows the operator to vary the slope extruded at the paver to account for the angle becoming steeper during compaction (roll up). Before construction, the Safety Edge device must be approved by the Representative(s).
Compact the roadway or paved shoulder as required by the specifications. Do not delay rolling of the mat adjacent to the Safety Edge. After compaction of the mat is complete, provide a Safety Edge meeting the final shape requirements as shown on the Standard Drawings. The completed angle of the Safety Edge must be 26 degrees to 40 degrees measured from the pavement cross slope extended. At the beginning of each day’s paving, measure the angle of the Safety Edge from the pavement cross slope extended. Perform measurements after final compaction is complete. If the angle of the Safety Edge does not meet the slope requirements, stop paving, and provide corrective action. Do not resume production paving until final shape requirements of Safety Edge are achieved.
Allow automatic transition to intersections, driveways, guiderail sections, and obstructions.
Use the device to constrain the asphalt head, reducing the area and increasing the density of the extruded profile. A single plate strike-off method is not allowed. Do not place the Safety Edge on organic material.
Section 413.3(h)2.a.1. Partially Completed Lots (n=2 or less). Revise to read as follows:
2.a.1 Partially Completed Lots (n=2 or less). When process conditions change to an extent that a partially completed lot cannot be combined with the most recently completed lot, samples will be independently evaluated on the partially completed lot. For asphalt content and percent passing the 75 μm (No. 200) sieve, mixture acceptance samples will be evaluated individually as specified in Section 413.2(e), Table A (n=1) criteria. For density, mat density acceptance samples will be evaluated individually using the criteria in Table E.
If samples tested for asphalt content and percent passing the 75 μm (No. 200) sieve meet the n=1 criteria of Table A, and samples tested for density meet the criteria in Table E, payment will be 100% of the contract unit price. If samples tested for asphalt content and percent passing the 75 μm (No. 200) sieve do not meet the n=1 criteria of Table A, the material will be considered defective. If samples tested for density are no more than 2.0% below the minimum or no more than 2.0% above the maximum limits of Table E, payment will be 90% of the contract unit price. If samples for density are more than 2.0% below the minimum or more than 2.0% above the maximum limits of Table E, the pavement will be considered defective.
Unless otherwise directed in writing by the District Executive, remove and replace defective work.
No additional revisions were made to Section 413.3(h)2.a.1.
Section 413.3(h)2.c.1. LTS Testing. Revise to read as follows:
2.c.1 LTS Testing. The LTS will test the mixture acceptance samples according to PTM No. 757 or PTM No. 702, Modified Method D and PTM No. 739, if previously identified problematic aggregates are used in the mixture, to determine asphalt content and the percent passing the 75 μm (No. 200) sieve. The LTS will use the calibration factors (Cf and 200 Cf) provided with the JMF for PTM
September 2, 2026 12:41:50 PM Page 20 of 65
No. 757. For individual increment test results outside of the single sample (n=1) tolerances in Table A, the LTS will analyze the test results for extreme values according to PTM No. 4 at the 5% significance level. If discarding an extreme value reduces a lot to less than three remaining test results, the Department will accept the lot as specified in Section 413.3(h)2.a.1. The Department will accept lots with three or more test results as specified in Section 413.4(a)4 or Section 413.4(b).
If the asphalt content or the percent passing the 75 μm (No. 200) sieve is not within the single sample (n=1) or multiple sample (n≥3) tolerances in Table A for two consecutive lots or a total of three lots, stop all production of the JMF. Determine the cause of the problem and provide a proposed solution to the Department.
Do not resume production of the JMF until the Representative reviews the proposed solution and authorizes production to continue.
The LTS will test Gmm verification samples as specified in Section 413.3(j)4.d.
Section 413.3(j)4.a. General. Revise to read as follows:
4.a General. Pavement cores are required for accepting the density of RPS construction. Pavement cores are required for standard construction of extended-season paving, unless waived by the Representative as specified in Section 413.3(b)1. Pavement cores are appropriate for accepting the density of standard construction if all the following materials, conditions, or applications exist:
Materials placed at indicated compacted depths greater than or equal to the minimum depths specified in Table G.
Materials placed on stable and uniform bases.
TABLE G
Mixture Minimum Indicated Compacted Depths
Mixture Minimum Depth
9.5 mm Wearing Course 1 1/2 in.
12.5 mm Wearing Course 2 in.
19 mm Binder Course 2 1/2 in.
25 mm Binder Course 3 in.
Section 413.3(m). Tests for Depth: Binder and Wearing Courses. Revise to read as follows:
(m) Tests for Depth: Binder and Wearing Courses. Construct the pavement to the depth indicated and within the specified tolerances.
For courses with a designed course depth and density acceptance by non-movement or optimum rolling pattern, the Inspector will calculate the weight per square yard for verification of yield. If yield results indicate insufficient course depth, drill one 6-inch diameter core for each 500 tons of material placed to determine the extent of the deficient depth as defined below. Core locations will be determined according to PTM No. 1.
For courses with density acceptance by lots, the inspector will measure the depth of each sublot according to PTM No. 737 using the density acceptance samples. After the Inspector completes depth measurements, backfill, compact, and seal core holes with the mixture used to construct the course. Deficient depth core(s) resulting in defective work should not be submitted for density acceptance testing. Once the defective work has been removed and replaced, obtain a new density acceptance sample for the sublot(s) as specified in Section 413.3(j)4.c.
Pavement deficient in depth by more than 1/8 inch in three or more adjacent acceptance core locations is defective. The extent of the defective work is the entirety of all sublots represented by the adjacent deficient acceptance core samples. The defective course will be the full width of the affected lane.
Pavement deficient in depth by more than 1/4 inch at a single acceptance core location is defective. Immediately delineate the limits of pavement deficient in depth from the acceptance core location by proceeding longitudinally, forward and backward, obtaining additional pavement cores every 50 feet until the depth is within 1/4 inch of the design depth. The defective course will be the full width of the affected lane.
Section 413.3(o). Defective Work. Revise to read as follows:
September 2, 2026 12:41:50 PM Page 21 of 65
(o) Defective Work. As specified in Section 105.12 and as follows:
Department acceptance and QA testing will not relieve the Contractor of responsibility for material or work that the Representative determines is defective before the Department issues the acceptance certificate. Remove and replace or repair defective work as directed.
The BOCM, CQAD will review Representative determinations of defective material or work.
Remove and replace pavement defective for temperature as specified in Section 413.3(h)1.a. for pattern segregation as specified in Section 413.3(h)3, for flushing as specified in Section 413.3(h)4, surface tolerance as specified in Section 413.3(l) or Section 313.3(l) and depth as specified in Section 413.3(m), or Section 313.3(m). Remove and replace pavement defective for percent within limits or Payment Factor Percentages as specified in Tables H and I.
Special Provision: C172A - a00172 CHANGES TO SPECIFICATIONS: SECTIONS 107, 871, 872, 875, and 876
Addendum:
CHANGES TO SPECIFICATIONS: SECTIONS 107, 871, 872, 875, and 876
Provision Body:
SECTION 107—LEGAL RELATIONS AND RESPONSIBILITY TO THE PUBLIC
Section 107.28 EROSION AND SEDIMENT POLLUTION CONTROL PLANS AND PERMITS. Revise to read as follows:
107.28 EROSION AND SEDIMENT POLLUTION CONTROL PLANS AND PERMITS—Install and maintain erosion and sediment (E&S) pollution control devices as indicated or submit an alternate plan for accomplishing equal or better temporary and permanent erosion and water pollution control. If an alternate plan is submitted, do not start work until the plan is approved by the County Conservation District and the Department. If a National Pollutant Discharge Elimination System (NPDES) Permit is involved, do not start work until the plan is approved by the DEP or the authorized County Conservation District and the Department. Concrete clean out areas, either contractor designed or indicated within the contract documents, are incidental to the contract items.
When a general or individual NPDES Permit is involved:
At the preconstruction conference, submit a Preparedness, Prevention and Contingency…