This document is a Questions and Answers file for federal contract opportunity SATPC0043099 concerning relief valves.
The solicitation requires an Anderson Greenwood (Emerson) Type 81 relief valve, OEM part number 81S W8A16A-6 (CAGE code 01343). The exact OEM part is mandatory and cannot be substituted with equivalent valves, as it is the only approved part per engineering drawing. For LH2 service, initial cleaning must be performed per KSC-C-123J, Level 300A, by an approved vendor, with subsequent cleaning to be accomplished at KSC using flow-through only methodology. The requirement need date is November 25, 2026; however, quotes with later delivery dates will be considered technically acceptable, though offerors are encouraged to obtain the earliest possible estimated delivery date. Delivery is to Kennedy Space Center, Florida 32899-0001, USA.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SATPC0043099: Relief valves we have received the following questions:
Can you confirm the manufacturer of OEM P/N 81S W8A16A-6? We read it as an Anderson Greenwood (Emerson) Type 81 relief valve.
o Yes, the manufacturer is Anderson Greenwood, CAGE code 01343.
Will an equivalent relief valve meeting the listed size, materials, set pressure and ASME requirements be considered, or is the exact OEM part required?
o Exact OEM Part required and cannot be substituted because it is the only approved part per engineering drawing.
Is a cleaning level or cleanliness certificate required for the LH2 service (for example a KSC or ASTM G93 cleaning specification)?
o Cleaning requirements are as follows: INITIAL CLEANING PER KSC-C-
123J, LEVEL 300A, BY APPROVED VENDOR, SUBSEQUENT CLEANING TO
BE ACCOMPLISHED AT KSC. FLOW THRU ONLY.
If manufacturer lead time runs past the 11/25/2026 need date, will a quote with a later delivery date still be considered technically acceptable?
o Yes, later dates can be accepted, this is just a need date based on schedule/work to be performed. Please try to obtain the earliest possible
EDD.
Please confirm the delivery address and receiving point at KSC.
o City: KENNEDY SPACE CENTER o State/Province: FL o Zip/Postal Code: 32899-0001 o Country: USA