SATPC0043014 Tab 04 4 SOW Updated 2.pdf

PDF 172 KB Posted

Attached to
FLOWMETER, CALIBRATION, AND SIGNAL CONDITIONERS NEEDED FOR PANEL MODIFICATION FOR ESR
Solicitation number
80NSSC26946800Q
Issued by

About this file

This is a Statement of Work for NASA Kennedy Space Center outlining parts procurement requirements for two specific projects related to Orion scrubber purge capability and cabin air supply monitoring.

The work consists of ordering 18 total items across two product categories. Six units of turbine flow meters (OEM Part # FT-08AER1-GEA-2) are required, each a 1/2" turbine flowmeter with 10 ACFM maximum capacity, rated to 300 degrees Fahrenheit, featuring 316 stainless steel housing with 430F stainless steel rotor, and 440C stainless steel ball bearings with magnetic pickoff and 2-pin MS connection. These meters must be calibrated per drawing 79K03436 KSC at Reynolds 1 gas specification, with CEESI calibration in air at 293 PSIA across 10 calibration points ranging from 31-206 SCFM. Additionally, six signal conditioner units (OEM Part # TWA-A-9-00-IS) are required, each a two-wire 4-20mA flowmeter transmitter with FTI RF pickoff input, explosion-proof enclosure rated for Class 1, Divisions 1 & 2, Groups A, B, C & D, and FM intrinsically safe certification. Both products are classified as EAR99 for export control purposes. Work will be performed at Kennedy Space Center facilities including the Vehicle Assembly Building, Mobile Launcher, and Multi-payload Processing Facility, with a performance period of 10/25/2026. The NASA point of contact is Juliane Brudnicki, AST Logistics Engineering Management, at 321.861.2508 or juliane.m.brudnicki@nasa.gov.

View the file

Other files

File Type Posted
SATPC0043014 Tab 04 4 Spec Sheet.pdf PDF
SATPC0043014 Tab 10 Open Market RFQ.pdf PDF
SATPC0043014 Tab 04 4 SOW.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

1. Objective/Requirements Parts need to be ordered to fulfill the following:

GP00688 will re-establish the Orion scrubber purge capability at MPPF using existing ML2 BAIR hardware.

GP00694 integrating two redundant flowmeters into the Cabin Air Supply Panel to enable direct SCFM measurement and provide real-time data to the firing room.

2. Characteristics, Scope, and Specs

Quantity OEM Part # Product Description

FT-08AER1-

GEA-2

TURBINE FLOW METER

FT-08 = 1/2" TURBINE FLOWMETER, 10 ACFM MAX,

300 DEG F

AE = AN (OR MS) EXTERNAL STRAIGHT THREADS,

37 DEG FLARE

R1 = 1 PRESSURE, REYNOLDS NUMBER

CALIBRATION IN AIR

G = GAS SERVICE

E = 316 SS HOUSING / 430F SS ROTOR

A = 440C SS BALL BEARINGS

-2= MAGNETIC PICKOFF, 2 PIN MS CONNECTION

MEDIA: AIR

SEE "LATEST REV" 79K03436 KSC DRAWING

6 90-88669-610

FOR FLOWMETERS

CALIBRATION: 90-88669-610 REYNOLDS 1 GAS 2-8

TO 16 BB

ECCN/ITAR: ECCN: EAR99

CEESI CALIBRATION

CALIBRATION WILL BE IN “AIR” @ 293 PSIA

10 POINTS 31 - 206 SCFM @ 293 PSIA

STD CONDITIONS: 14.7 PSIA & 60° F

6 TWA-A-9-00-IS

SIGNAL CONDITIONER

ECCN/ITAR: ECCN: EAR99

TWA = TWO WIRE 4-20MA FLOWMETER

TRANSMITTER

C = FTI RF PICKOFF INPUT

9 = ENCLOSURE, EXPLOSION PROOF: CLASS 1, DIV.

1 & 2, GP. A, B, C & D

IS = FM INTRINSICALLY SAFE

3. Place of Performance

Kennedy Space Center

Work will be performed at the Vehicle Assembly Building (VAB) on the Mobile Launcher (ML), and Multi-payload Processing Facility (MPPF)

4. Period of Performance 10/25/2026

Juliane Brudnicki AST, Logistics Engineering Management John F. Kennedy Space Center K6-1547 (Logistics Facility), Room 3520EI o: 321.861.2508 juliane.m.brudnicki@nasa.gov mailto:juliane.m.brudnicki@nasa.gov https://gcc02.safelinks.protection.outlook.com/?url=https%3A%2F%2Fwww.nasa.gov%2F&data=05%7C02%7Cjuliane.m.brudnicki%40nasa.gov%7Ccdc586e1e6d24278c40508df1ef1cbac%7C7005d45845be48ae8140d43da96dd17b%7C0%7C0%7C639263696272072171%7CUnknown%7CTWFpbGZsb3d8eyJFbXB0eU1hcGkiOnRydWUsIlYiOiIwLjAuMDAwMCIsIlAiOiJXaW4zMiIsIkFOIjoiTWFpbCIsIldUIjoyfQ%3D%3D%7C0%7C%7C%7C&sdata=xWlfPnRVg8%2BD1jCf8kqqytucZSU5PQr3Ra4od4FWEnQ%3D&reserved=0