SATPC0042587 TAB 04 SOW.pdf
PDF 325 KB Posted
- Solicitation number
- 80NSSC26942448Q
About this file
This document is a procurement requirements list for spare parts to support the Converter Compressor Facility (CCF) at Kennedy Space Center, specifically for high-pressure nitrogen and helium pipelines used in vehicle and launch processing operations.
The procurement includes thirteen line items of ultrasonic flowmeter equipment and accessories manufactured by Flexim. Primary components include: one FLUXUS G601 Basic transmitter with integrated accessories (part DE6-G601GP-NNNNN-2PG3-NN.CS2); six clamp-on transducers with various specifications—one P-type shear wave at 2 MHz (TRD-GSP-NNNN-NNNL-004), one M-type shear wave at 1 MHz (TRD-GSM-NNNN-NNNL-004), and two gas measurement P-type transducers at 2 MHz (TRD-GSP-NF2 N-NNTI-004); two FLUXUS G731 transmitters with explosion protection rated for FM Class I, II, and III Division 2 (DE7-G731GP-F2NNN-2ST4-MR.CS2.MN4.TT2.IS2/FVA); and supporting equipment including ladder chain brackets, portable chain mounting kits, wall thickness probes, pipe damping material, mountings, fasteners, and temperature probes. All items must be purchased new. Delivery is to NASA Kennedy Space Center, BOSS Warehouse Building M6-0744, Attention Andrew Cline, Orlando, Florida 32899. Included subparts and accessories are listed under decimal line item numbers and are bundled with their corresponding primary line items.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SATPC0042587 TAB 06 BNJ_Redacted.pdf | ||
| SATPC0042587 Tab 12 RFQ Open Market Template APR 2026.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Procurement of CCF (Converter Compressor Facility) Spare Parts – Flexim
1.0 Background
Spare parts are required to be purchased to have on hand in the event of component failure, to minimize outages and provide continued support to the high-pressure nitrogen and helium pipelines. This purchase is for spare parts to support this effort. Specifically, multiple permanent ultrasonic flowmeters are required in addition to a portable ultrasonic flowmeter to measure high-pressure inert gases. The procurement also includes several items that are considered included subparts from the vendor and are identified below.
2.0 Requirements
The following are spare items that need to be purchased to support propellant and life support operations at Kennedy Space Center for vehicle and launch processing. Items must be purchased new. Line items with a dot (.) correspond to the above listed line item and are included with the preceding line item.
Item No. Part Number Description Quantity
DE6-G601GP-NNNNN-2PG3-
NN.CS2
Transmitter, FLUXUS G601 Preferred version: G601 Basic
1.1
• 60076G-44
• 600712-0
• 600137-1
• 610622-1
• 670622-3
• 990744-23
• 992020-1
• 610622-3
-Operating instruction -Carrying case -Transmitter-Fixation -Power supply units -Power cable -Data transmission kit -Measuring tape -Output adapter
1 (each) These are included in line item #1
2 TRD-GSP-NNNN-NNNL-004
Clamp-On Transducer
GDP1NZ7
Transducer calibration with aperture calibration 6 measuring points, including calibration certificate Shear wave, P-type (2 MHz)
2.1
• 990739-6
• 990739-1
-Coupling foils -Coupling compound
1 (each) These are included in line item #2
3 TRD-GSM-NNNN-NNNL-004
Clamp-On Transducer, GDP1NZ7 Transducer calibration with aperture calibration 6 measuring points, including calibration certificate Shear wave, M-type (1 MHz)
3.1
• 990739-6
• 990739-1
-Coupling foils -Coupling compound
1 (each) These are included in line item #3
4 US-601.CM.MB Ladder chain brackets for GLM/GLP 1
5 US-601.CM.MQl
Portable Chain Mounting Kit for M & Q transducers, Suitable for Pipe sizes of up to 24" in outer diameter two tensioners included
6 600522-0
Wall thickness probe for F/6601, -4 ... +392 °F, short-term max. +932 °F, integrated transducer detection and automatic activation of the measurement
7 US-DMPKIT.1
Pipe damping material for gas measurement, self-adhesive for permanent installation
DE7-G731GP-F2NNN-2ST4-
MR.CS2.MN4.TT2.IS2/FVA
Transmitter, G731 G731 [G) FLUXUS for the measurement of: gases [731) Type: 731 [GP] General purpose [F2] explosion protection:
FM Class I, II, Ill Div. 2 [NI Non-intrinsically safe [NN] No additional certificate [2) Measuring channels : 2 [STI Housing: stainless steel [4] Power supply: 11...32 V DC [MR) Modbus RTU Outputs [CS2) 2 x current output, switchable, active/passive, 0/4 ... 20 mA [MN4) 4 x digital output (open collector) 8.2 V NAMUR (DIN EN 60947-5-6), status, pulse, frequency 0.002 ... 10 kHz Inputs [TT2) 2 x temperature input Ptl00/1000 [IS2) 2 x active/passive current input [FVA) Advanced Meter Verification !Full functionality only with FluxDiagfull version
8.1
• 731761-00
• 721110-4
• 801037-9
• 990760-10
-Operating instruction -Transmitter-Fixation (option) -Data transmission kit -Supplements
2 (each) These are included in line item #8
9 TRD-GSP-NF2 N-NNTl-004
Clamp-on transducer, Transducer cal ibration with aperture calibration 6 measuring points, including calibration certificate (factory calibration, no accredited report) [GI For the measurement of: gases [SI Typ: Shear wave [Pl Transducer frequency P-2 MHz Inner pipe diameter (recommended): 0.79 ... 2.0 in inner pipe diameter (extended): 0.59 ... 2.4 in
[N] Normal temperature [F2] explosion protection: FM Class I, II, Ill Div. 2 [NN] No additional certificate [Tl] Connection system: stripped cable ends [004] Cable length: 13 ft
9.1
• 990739-6
• 990739-22
-Coupling foils -Coupling Compound
2 (each) These are included in line item #9
10 MOU-VLP-DS-SSSKl
Mounting:
[VL] Variofix L For transducer frequency P - 2 MHz [DI Measurement arrangement: diagonal or reflection [SI Inner rail length: 9.20 in [SI Fixation: tension straps [SSKl] 0.5'' - 2.5"
11 US-MOU.SKl Fastener for Ptl00/1000:
Strap kit for pipe sizes 0.5"-2.5"
12 770413-1
Temperature probe (clamp-on):
Clamp-On temperature sensor consisting of: 1 ea . 1000-ohm clamp-on platinum RTD, 4-wire, DIN IEC 751 class A, measuring range-22 to 392 °F, 30 ft cable, prepared for junction box and direct connection
13 US-DMPKIT.l Pipe damping material for gas measurement, self-adhesive for permanent installation
Ship to:
ATTN: Andrew Cline
NASA/ Kennedy Space Center
BOSS Warehouse – Bldg. M6-0744
Kennedy Space Center
ORLANDO FL 32899
File details come from the government source that posted it. Updated .