SATPC0042587 TAB 04 SOW.pdf

PDF 325 KB Posted

Attached to
CCF (Converter Compressor Facility) Transmitter and Spare Parts – Flexim Brand Name
Solicitation number
80NSSC26942448Q
Issued by

About this file

This document is a procurement requirements list for spare parts to support the Converter Compressor Facility (CCF) at Kennedy Space Center, specifically for high-pressure nitrogen and helium pipelines used in vehicle and launch processing operations.

The procurement includes thirteen line items of ultrasonic flowmeter equipment and accessories manufactured by Flexim. Primary components include: one FLUXUS G601 Basic transmitter with integrated accessories (part DE6-G601GP-NNNNN-2PG3-NN.CS2); six clamp-on transducers with various specifications—one P-type shear wave at 2 MHz (TRD-GSP-NNNN-NNNL-004), one M-type shear wave at 1 MHz (TRD-GSM-NNNN-NNNL-004), and two gas measurement P-type transducers at 2 MHz (TRD-GSP-NF2 N-NNTI-004); two FLUXUS G731 transmitters with explosion protection rated for FM Class I, II, and III Division 2 (DE7-G731GP-F2NNN-2ST4-MR.CS2.MN4.TT2.IS2/FVA); and supporting equipment including ladder chain brackets, portable chain mounting kits, wall thickness probes, pipe damping material, mountings, fasteners, and temperature probes. All items must be purchased new. Delivery is to NASA Kennedy Space Center, BOSS Warehouse Building M6-0744, Attention Andrew Cline, Orlando, Florida 32899. Included subparts and accessories are listed under decimal line item numbers and are bundled with their corresponding primary line items.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Procurement of CCF (Converter Compressor Facility) Spare Parts – Flexim

1.0 Background

Spare parts are required to be purchased to have on hand in the event of component failure, to minimize outages and provide continued support to the high-pressure nitrogen and helium pipelines. This purchase is for spare parts to support this effort. Specifically, multiple permanent ultrasonic flowmeters are required in addition to a portable ultrasonic flowmeter to measure high-pressure inert gases. The procurement also includes several items that are considered included subparts from the vendor and are identified below.

2.0 Requirements

The following are spare items that need to be purchased to support propellant and life support operations at Kennedy Space Center for vehicle and launch processing. Items must be purchased new. Line items with a dot (.) correspond to the above listed line item and are included with the preceding line item.

Item No. Part Number Description Quantity

DE6-G601GP-NNNNN-2PG3-

NN.CS2

Transmitter, FLUXUS G601 Preferred version: G601 Basic

1.1

• 60076G-44

• 600712-0

• 600137-1

• 610622-1

• 670622-3

• 990744-23

• 992020-1

• 610622-3

-Operating instruction -Carrying case -Transmitter-Fixation -Power supply units -Power cable -Data transmission kit -Measuring tape -Output adapter

1 (each) These are included in line item #1

2 TRD-GSP-NNNN-NNNL-004

Clamp-On Transducer

GDP1NZ7

Transducer calibration with aperture calibration 6 measuring points, including calibration certificate Shear wave, P-type (2 MHz)

2.1

• 990739-6

• 990739-1

-Coupling foils -Coupling compound

1 (each) These are included in line item #2

3 TRD-GSM-NNNN-NNNL-004

Clamp-On Transducer, GDP1NZ7 Transducer calibration with aperture calibration 6 measuring points, including calibration certificate Shear wave, M-type (1 MHz)

3.1

• 990739-6

• 990739-1

-Coupling foils -Coupling compound

1 (each) These are included in line item #3

4 US-601.CM.MB Ladder chain brackets for GLM/GLP 1

5 US-601.CM.MQl

Portable Chain Mounting Kit for M & Q transducers, Suitable for Pipe sizes of up to 24" in outer diameter two tensioners included

6 600522-0

Wall thickness probe for F/6601, -4 ... +392 °F, short-term max. +932 °F, integrated transducer detection and automatic activation of the measurement

7 US-DMPKIT.1

Pipe damping material for gas measurement, self-adhesive for permanent installation

DE7-G731GP-F2NNN-2ST4-

MR.CS2.MN4.TT2.IS2/FVA

Transmitter, G731 G731 [G) FLUXUS for the measurement of: gases [731) Type: 731 [GP] General purpose [F2] explosion protection:

FM Class I, II, Ill Div. 2 [NI Non-intrinsically safe [NN] No additional certificate [2) Measuring channels : 2 [STI Housing: stainless steel [4] Power supply: 11...32 V DC [MR) Modbus RTU Outputs [CS2) 2 x current output, switchable, active/passive, 0/4 ... 20 mA [MN4) 4 x digital output (open collector) 8.2 V NAMUR (DIN EN 60947-5-6), status, pulse, frequency 0.002 ... 10 kHz Inputs [TT2) 2 x temperature input Ptl00/1000 [IS2) 2 x active/passive current input [FVA) Advanced Meter Verification !Full functionality only with FluxDiagfull version

8.1

• 731761-00

• 721110-4

• 801037-9

• 990760-10

-Operating instruction -Transmitter-Fixation (option) -Data transmission kit -Supplements

2 (each) These are included in line item #8

9 TRD-GSP-NF2 N-NNTl-004

Clamp-on transducer, Transducer cal ibration with aperture calibration 6 measuring points, including calibration certificate (factory calibration, no accredited report) [GI For the measurement of: gases [SI Typ: Shear wave [Pl Transducer frequency P-2 MHz Inner pipe diameter (recommended): 0.79 ... 2.0 in inner pipe diameter (extended): 0.59 ... 2.4 in

[N] Normal temperature [F2] explosion protection: FM Class I, II, Ill Div. 2 [NN] No additional certificate [Tl] Connection system: stripped cable ends [004] Cable length: 13 ft

9.1

• 990739-6

• 990739-22

-Coupling foils -Coupling Compound

2 (each) These are included in line item #9

10 MOU-VLP-DS-SSSKl

Mounting:

[VL] Variofix L For transducer frequency P - 2 MHz [DI Measurement arrangement: diagonal or reflection [SI Inner rail length: 9.20 in [SI Fixation: tension straps [SSKl] 0.5'' - 2.5"

11 US-MOU.SKl Fastener for Ptl00/1000:

Strap kit for pipe sizes 0.5"-2.5"

12 770413-1

Temperature probe (clamp-on):

Clamp-On temperature sensor consisting of: 1 ea . 1000-ohm clamp-on platinum RTD, 4-wire, DIN IEC 751 class A, measuring range-22 to 392 °F, 30 ft cable, prepared for junction box and direct connection

13 US-DMPKIT.l Pipe damping material for gas measurement, self-adhesive for permanent installation

Ship to:

ATTN: Andrew Cline

NASA/ Kennedy Space Center

BOSS Warehouse – Bldg. M6-0744

Kennedy Space Center

ORLANDO FL 32899