SATPC0032524 Q and A.pdf

PDF 49 KB Posted

Attached to
Ultrasonic Cleaning System Federal contract opportunity
Solicitation number
80NSSC23844421Q
Issued by
National Aeronautics and Space Administration Shared Services Center

About this file

This document contains questions and answers related to Federal Solicitation 80NSSC23844421Q from the National Aeronautics and Space Administration Shared Services Center for an ultrasonic cleaning system. The questions and answers provide specifications for three ultrasonic cleaning tanks such as desired dimensions of 50" left to right, 36" front to back, and 28" in depth. Logistical details are also addressed, including a minimum 10ft wide by 10ft tall doorway for tank access, ventilation duct installation, and control enclosure placement between 6ft and 30ft from tanks. Materials handling requirements specify use of an overhead crane for heavy items and baskets for personnel transfers between tanks.

View the file

Other files for this federal contract opportunity

Other files attached to Ultrasonic Cleaning System, newest first.
File Type Posted
SATPC0032524 Tab 10 Open Market RFQ.pdf PDF
SATPC0032524 Tab 04 4 SOW (Redacted).pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Is onsite setup and training required for this equipment? No, as long as instruction manuals are includes.

Is there a site visit scheduled? No What cleaning spec is being utilized here? Internal What is the minimum size of a doorway /ingress the tanks must pass through to get to the final location? 10ft wide x 10 ft tall roll up door Are common utility connections for all 3 tanks desired or do you want to have to water/air/drain to each tank? Each tank Is a ground drain available? No How are parts transferred from tank to tank? Heavy items an overhead crane, baskets when personnel are physically doing the transfer Are baskets needed? Yes Are piezo electric transducers acceptable? No. They can have similar performance and are much more cost effective.

Is there a reason the government wants magnetostrictive ? Primarily the maintenance-free reliability and the history of use at another NASA facility.

What is the maximum weight load expected? Up to 500 lbs in a basket, heavier items will be supported by an overhead crane.

What is the maximum part size? Requested the working dimensions of tanks are Left to Right: 50”, Front to Back: 36”, Depth: 28” How will the ventilation duct be connected at the end user facility? Desire ventilation duct located to the rear of the cleaning chamber, will be connect by others to a wall mounted exhaust fan.

Is a powered exhaust system required? No.

Is there a limit to the overall size of the system? Yes, each tank’s overall maximum dimensions are listed in SOW.

How far will the control enclosure be from the tanks? Closest tank approx.. 6ft and farthest tank approx.

30 ft away. Can they all be attached to the same frame? No.