RFQ Questions and answers:
1. Question: Actuator Stroke indicates 1800 mm Minimum in the statement of work (SOW) on page 5 specifications. Is this important to NASA?
Answer: Yes, 1800mm is an important requirement for NASA.
2. Question: Page 6 of the SOW shows a notational sketch of the top interface. Is the vendor to supply this top interface as part of the quote?
Answer: Yes. NASA requires the top interface to match our standard bolt pattern interface and ID clearance for test article payloads.
3. Question: Page 5 of the SOW indicates 50 cm/sec actuator rate. Is this the minimum required rate?
Answer: The minimum requirement is 30 cm/sec.