8-08 Attachment 6.7. Asbestos Abatement Scope of Work - 1809 W Avenue M.pdf

PDF 138 KB Posted

Attached to
Asbestos Abatement & Demolition of 1102 S Main Street and 1809 W Avenue M
Solicitation number
Bid #37-01-26
Issued by
Bell County, Texas

About this file

This is a Scope of Work document prepared by Austin Environmental, Inc. for the City of Temple, Texas, dated November 19, 2025, addressing asbestos abatement services at the former Transmission Shop located at 1809 W Avenue M. The project involves the removal of Category 2 nonfriable asbestos-containing materials (ACM) from six contaminated window caulking and glazing installations. The scope of work encompasses engineering controls including submission of a ten working day Texas Department of State Health Services demolition notification prior to abatement, compliance with National Emission Standard for Hazardous Air Pollutants (NESHAP) regulations under 40 CFR part 61, subpart M, and adherence to Occupational Safety and Health Administration (OSHA) standards for Class II asbestos operations under 29 CFR 1926.1101.

The work requires deployment of properly trained and accredited asbestos workers and NESHAP-trained competent personnel utilizing wet removal procedures, regulated work areas with barrier tape, appropriate signage, personal protective equipment including protective suits and HEPA respirators, polyethylene sheeting, and Phase Contrast Microscopy (PCM) air monitoring. The contractor must ensure proper waste disposal at an approved asbestos landfill and provide comprehensive project documentation to the City including worker accreditations, respiratory fit testing records, asbestos waste shipment manifests, and DSHS demolition notifications. Air monitoring will include upwind, downwind, and personal sampling analyzed in compliance with NIOSH 7400 Counting Rule A methodology. Austin Environmental, Inc. holds Individual Asbestos Consultant License No. 10-5523 and can be contacted at (979) 229-4385 for additional asbestos-related services.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AUSTIN ENVIRONMENTAL, INC.

AUSTIN, TX. (512) 587-8036

P.O. Box 143263

Austin, Texas 78714

(512) 587-8036

November 19, 2025

City of Temple Jeff Scharp 3210 E. Ave., H, Bldg., C Temple, Texas

RE: Scope of Work-Former Transmission Shop, 1809 W. Ave. M, Temple-

Asbestos Window Caulking/Glazing Project, Asbestos Work Practices for the Removal of Category 2 Nonfriable Asbestos Containing Materials (ACM)

Mr. Scharp:

The scope of work for the six (6) asbestos contaminated window caulking/glazing for the former Transmission Shop includes the following:

The asbestos work practices and procedures should be performed using the following engineering controls;

1. A ten (10) working day Texas Department of State Health Services (DSHS) demolition notification will be submitted prior to asbestos abatement /structural demolition.

2. Compliance with the asbestos National Emission Standard for Hazardous Air

Pollutants (NESHAP) 40 CFR part 61, subpart M.

3. Compliance with the Occupational Safety and Health Administration (OSHA) 29

CFR 1926.1101 Class II asbestos operation.

4. Properly trained/accredited asbestos worker, NESHAP trained competent person.

5. Proper asbestos work practices including, no visible emissions, hygiene facility, wet removal/disposal, regulated work area, barrier tape, asbestos / caution signs, personal protection equipment (PPE) (protective suits/ half face HEPA respirators), poly sheeting, PCM air monitoring and proper waste disposal in a approved asbestos landfill.

AUSTIN, TX. (512) 587-8036

November 19, 2025

6. Project documentation provided to the City of Temple include; accredited asbestos contractor/supervisor, asbestos worker accreditation, NESHAP trained / competent person, respiratory fit testing, asbestos worker acknowledgement, asbestos waste shipment records (manifests) and DSHS demolition notification.

7. Asbestos air monitoring will be performed by Austin Environmental Inc., to include upwind, downwind and personal air monitoring. Asbestos air samples will be analyzed by Phase Contrast Microscopy (PCM) in compliance with NIOSH

7400 Counting Rule A method.

Should you need any further asbestos-related services; please don’t hesitate to contact us at (979) 229-4385.

Respectfully submitted, Individual Asbestos Consultant License No. 10-5523

File details come from the government source that posted it. Updated .