The contractor shall furnish and install new electronic lock entry doors integrated with the existing Rectrac access control system and compatible with the SmartNet Access Control System software. At Southside Fitness Center, the contractor must remove and dispose of two existing single doors and install two new Aluprof MB-79N aluminum doors (approximately 875mm x 2065mm each) with RAL 8016 mahogany brown matte finish, thermal insulation, EN1125-compliant panic/emergency exit hardware, outward opening capability, and DC electric locks. At both Northside Fitness Center and Vogelweh Fitness Center, the contractor must remove and dispose of existing double doors and install one new Aluprof MB-79N aluminum double door (approximately 2190mm x 2245mm) each with identical specifications. All doors must integrate with existing swipe card readers and the Rectrac system, with the contractor responsible for all measurements, professional installation per applicable building codes and safety regulations, and disposal of old materials. Deliverables include fully functional installed doors at all three locations, five keys per lock with associated documentation, and proper debris removal. The work is located at Southside Fitness Center and Northside Fitness Center at Ramstein Air Base, Germany, and Vogelweh Fitness Center at Vogelweh/Kapaun, Germany, with an estimated delivery and installation timeframe of 6-8 weeks from order/payment.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statement of Work (SOW) 786 FSS Replacement of 24/7 Access Doors
1.0 General
This Statement of Work (SOW) defines the requirements for the purchase and installation of new electronic lock entry doors at three fitness centers on Ramstein Air Base and Kapaun: Southside Fitness Center, Northside Fitness Center, and Vogelweh Fitness Center (Kapaun). The new doors will be integrated with the existing 24/7 access control system (Rectrac) and will be compatible with SmartNet Access Control System software that will be installed per AFSVC later this year.
2.0 Scope of Work
The contractor shall provide all necessary materials, labor, and equipment to perform the following work:
2.1 Southside Fitness Center
• Remove and dispose of the two existing single main entrance doors (far left and far right).
• Furnish and install two (2) new Aluprof MB-79N aluminum doors, or equivalent, with the following specifications:
• Color: RAL 8016 Mahogany brown matt.
• Dimensions: approximately 875mm x 2065mm each.
• Thermal insulation.
• Panic/emergency exit hardware (EN1125 compliant).
• Outward opening.
• Install a DC electric lock compatible with the existing Rectrac access control system and Smartnet access control system.
• Integrate the new doors and locks with the existing swipe card readers and
Rectrac system to ensure full functionality.
• Perform all necessary finishing work, including the installation of aluminum trim.
2.2 Northside Fitness Center
• Remove and dispose of the existing double main entrance door.
• Furnish and install one (1) new Aluprof MB-79N aluminum double door, or equivalent, with the following specifications:
• Color: RAL 8016 Mahogany brown matt.
• Dimensions: approximately 2190mm x 2245mm.
• Thermal insulation.
• Panic/emergency exit hardware (EN1125 compliant).
• Outward opening.
• I Install a DC electric lock compatible with the existing Rectrac access control system and Smartnet access control system.
• Integrate the new doors and locks with the existing swipe card readers and Rectrac system to ensure full functionality.
2.3 Vogelweh Fitness Center
• Remove and dispose of the existing double main entrance door.
• Furnish and install one (1) new Aluprof MB-79N aluminum double door, or equivalent, with the following specifications:
• Color: RAL 8016 Mahogany brown matt.
• Dimensions: approximately 2190mm x 2245mm.
• Thermal insulation.
• Panic/emergency exit hardware (EN1125 compliant).
• Outward opening.
• Install a DC electric lock compatible with the existing Rectrac access control system and Smartnet access control system.
• Integrate the new doors and locks with the existing swipe card readers and Rectrac system to ensure full functionality.
3.0 Technical Requirements
• All doors and hardware must be new and of commercial-grade quality, suitable for high-traffic entrances.
• The electronic locking mechanisms must be capable of continuous operation and integrate seamlessly with the existing Rectrac access control system and future Smartnet Access Control System. The existing swipe card readers will be reused if functional or replaced if necessary.
• All installation work shall be performed in a professional manner and in accordance with all applicable building codes and safety regulations.
• The contractor is responsible for all measurements and for ensuring the new doors fit the existing openings correctly.
4.0 Deliverables
• Fully functional and installed electronic entry doors at all three locations as specified in this SOW.
• All keys (5 per lock) and any associated documentation for the new hardware.
• Proper disposal of all old materials and debris from the work sites.
5.0 Place of Performance
• Southside Fitness Center, Ramstein Air Base, Germany
• Northside Fitness Center, Ramstein Air Base, Germany
• Vogelweh Fitness Center, Vogelweh/Kapaun, Germany
6.0 Period of Performance