Sol_75N98027Q00089.pdf
PDF 594 KB Posted
- Solicitation number
- 75N98027Q00089
About this file
This is a Request for Quotation (RFQ) issued by the National Institutes of Health (NIH), Office of Logistics and Acquisition Operations, with solicitation number 75N98027Q00089/PCA-NIA-01610. The acquisition is for a 10 mm 1H/31P microimaging coil for 14 Tesla MRI, specifically the MicWB40 Selective Imaging 31P/1H double resonance RF insert (Bruker Biospin, Inc. product code PI2591_DX/HP). The RFQ is a combined synopsis/solicitation for commercial items prepared under FAR Subpart 12.6 and conducted under streamlined acquisition authority (FAR 12.603), with an estimated value not expected to exceed the simplified acquisition threshold. The associated NAICS code is 339112, and the small business size standard is "Other than Small Business." This is not a small business set-aside, and the Government intends to award using full and open competition. The coil must have a 10 mm nominal inner diameter, interface mechanically with existing Bruker MICWB40 microimaging probehead equipment, include dual RF circuits tunable to 600 MHz (1H) and 243 MHz (31P) frequencies at 14T, support simultaneous excitation and reception of both nuclear spins, include independent tuning controls, feature a slotted shield for minimal electromagnetic coupling, operate across a temperature range from +4°C to +37°C, and include a removable fixture to lock 10 mm NMR tubes. The delivery location is NIH/NIA at 251 Bayview Blvd STE 100, BRC Building, Baltimore MD 21224, with delivery required as multiple (the exact quantity and delivery schedule details appear on the form). Quotations must be submitted electronically to johnsonjr@mail.nih.gov by December 1, 2026, at 2:00 PM EST, referencing the solicitation number. Responses must include unit and total price, shipping and handling costs, delivery timeframe, delivery terms, F.O.B. point, product/catalog numbers, and product description, along with Unique Entity Identifier (UEI), Taxpayer Identification Number (TIN), and business size certification. All offerors must be actively registered in the System for Award Management (SAM) at www.sam.gov. Evaluation factors include price, technical capability, past performance, and delivery schedule. The point of contact is John Johnson, Program Specialist, at johnsonjr@mail.nih.gov or 667-312-5580.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sol_75N98027Q00089_Amd_0001.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REQUEST FOR QUOTATION
(THIS IS NOT AN ORDER)
THIS RFQ IS IS NOT A SMALL BUSINESS SET-ASIDE
15. DATE OF QUOTATION
16. SIGNER
a. NAME (Type or print)
c. TITLE (Type or print)
b. TELEPHONE
AREA CODE
NUMBER
STANDARD FORM 18 (REV. 6/1995)
Prescribed by GSA-FAR (48 CFR) 53.215-1(a)
AUTHORIZED FOR LOCAL REPRODUCTION
Previous edition not usable
8. TO:
b. COMPANYa. NAME
c. STREET ADDRESS
d. CITY e. STATE f. ZIP CODE
9. DESTINATION
a. NAME OF CONSIGNEE
b. STREET ADDRESS
d. STATE e. ZIP CODE
7. DELIVERY
FOB DESTINATION
OTHER
(See Schedule)
10. PLEASE FURNISH QUOTATIONS TO THE
ISSUING OFFICE IN BLOCK 5a ON OR BEFORE CLOSE OF BUSINESS (Date)
IMPORTANT: This is a request for information and quotations furnished are not offers. If you are unable to quote, please so indicate on this form and return it to the address in Block 5a. This request does not commit the Government to pay any costs incurred in the preparation of the submission of this quotation or to contract for supplies or service. Supplies are of domestic origin unless otherwise indicated by quoter. Any representations and/or certifications attached to this Request for Quotation must be completed by the quoter.
11. SCHEDULE (Include applicable Federal, State and local taxes)
ITEM NUMBER
(a)
SUPPLIES/SERVICES
(b)
QUANTITY
(c)
UNIT
(d)
UNIT PRICE
(e)
AMOUNT
(f)
12. DISCOUNT FOR PROMPT PAYMENT
a. 10 CALENDAR DAYS (%) b. 20 CALENDAR DAYS (%) c. 30 CALENDAR DAYS (%) d. CALENDAR DAYS
NUMBER PERCENTAGE
NOTE: Additional provisions and representations are are not attached.
13. NAME AND ADDRESS OF QUOTER
a. NAME OF QUOTER
b. STREET ADDRESS
c. COUNTY
d. CITY e. STATE f. ZIP CODE
14. SIGNATURE OF PERSON AUTHORIZED TO
SIGN QUOTATION
PAGE OF PAGES
1. REQUEST NUMBER 2. DATE ISSUED 3. REQUISITION/PURCHASE REQUEST NUMBER 4. CERT. FOR NAT. DEF.
UNDER BDSA REG. 2
AND/OR DMS REG. 1
RATING
5a. ISSUED BY 6. DELIVER BY (Date)
NAME TELEPHONE NUMBER
AREA CODE NUMBER
c. CITY
5b. FOR INFORMATION CALL (NO COLLECT CALLS)
National Institutes of Health OD - Office of Logistics and Acquisition Operations 6100 Executive Blvd., Room 6B05 Bethesda, MD 20892-7511
75N98027Q00089
JOHN JOHNSON
+10
000-000000
11/16/2026
12/01/2026 1400 ES
Multiple
The purpose of this COMBINED
SYNOPSIS/SOLICITATION (Brand Name or
Only) is to acquire a 10 mm 1H/31P microimaging coil for 14 Tesla MRI.
The following FAR clauses and Provisions are applicable to this award.
FAR 52.204-13 System for Award
Management Maintenance (Oct 2018)
FAR 52.204-18 Commercial and Government
Entity Code Maintenance (Aug 2020)
HHSAR 352.222-70, Contractor Cooperation in Equal Employment Opportunity
Investigations (Dec 2015)
FAR 52.212-4 Contract Terms and
Continued...
1 13
CONTINUATION SHEET
REFERENCE NO. OF DOCUMENT BEING CONTINUED PAGES
NAME OF OFFEROR OR CONTRACTOR
SUPPLIES/SERVICES
(B)
UNIT
(D)
UNIT PRICE
(E)
AMOUNT
(F)
OPTIONAL FORM 336 (4-86)
Sponsored by GSA FAR (48 CFR) 53.110
ITEM NO.
(A)
QUANTITY
(C)
NSN 7540-01-152-8067
75N98027Q00089
Conditions -In addition to all the applicable commercial Products and Commercial Services
(Nov 2023)
FAR 52.212-5 Contract Terms and Conditions
Required to Implement Statutes or Executive
Orders/Commercial Products and Commercial
Services (Jan 2025)
FAR 52.217-8 Option to Extend Services (Nov
1999)
FAR 52.252-2 CLAUSES INCORPORATED BY REFERENCE
COMBINED SYNOPSIS / SOLICITATION/ (Brand Name or Equal)
Title: 10 mm 1H/31P microimaging coil
(i) This is a combined synopsis/solicitation for commercial items prepared in accordance with FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested, and a separate written solicitation will not be issued.
(ii) The solicitation number is 75N98027Q00089/PCA-NIA-01610. This solicitation is issued as a small business competitive combined synopsis/solicitation for commercial products or commercial services. The Government intends to award a contract or purchase order resulting from this solicitation using full and open competition.
This acquisition is conducted under the authority of FAR 12.603, Streamlined Solicitation for Commercial Products or Commercial Services, and is not expected to exceed the simplified acquisition threshold.
The National Institutes of Health (NIH), Office of the Director, Office of Acquisitions, seeks to award a firm fixed-price award to the responsible offeror whose proposal represents the best value to the Government.
(iii) The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular March 2026.
(iv) The associated NAICS code is 339112, and the small business size standard is “Other than Small Business”
(v) Description of Requirement:
GENERAL REQUIREMENTS:
Organoids are laboratory-grown aggregates of cells that mimic the properties of tissues in live animals and humans, providing a simple, inexpensive platform for basic research that is more realistic than cells grown in traditional, two-dimensional culture. In NIA, we are using brain cell organoids to investigate the structural and bioenergetic effects of normal aging and age-associated neurodegenerative diseases. Proton magnetic resonance imaging (1H MRI) and phosphorus-31 nuclear magnetic resonance spectroscopy (31P NMR) provide a non-destructive means of evaluating microstructure and mitochondrial function in organoids that can be applied longitudinally, following changes that occur with maturation. Unfortunately, with our current apparatus, we are unable to perform 1H MRI and 31P NMR experiments concurrently, since we are forced to switch configuration repeatedly between the 1H-only radio-frequency (RF) coil on our microimaging probehead and a high-resolution NMR probehead equipped with a 31P RF coil. Each change between 1H MRI and 31P NMR requires removing the perfusion apparatus from the magnet and not only wastes time but also jeopardizes the stability of the organoids. By purchasing a dual-tuned, 1H/31P RF coil for our microimaging probehead, we will circumvent these problems and allow frequent monitoring of cell viability by 31P NMR during long, complex microimaging experiments.
Description: MicWB40 Selective Imaging 31P/1H double resonance 10mm RF insert designed for separate 1H and 31P, or double frequency experiments., Bruker Biospin, Inc. product code PI2591_DX/HP (MicWB40-INS-DR-31P/1H-10mm).
SALIENT CHARACTERISTICS:
Nominal inner diameter of 10 mm to accommodate samples in standard 10 mm OD glass NMR tubes (needed for compatibility with home-built organoid perfusion system, which uses these tubes).
Interfaces mechanically with existing Bruker MICWB40 microimaging probehead, sliding onto and matching the screw holes on the probehead while engaging the probehead’s coaxial connector and tuning rods.
The position of the radio-frequency (RF) coil center must align with the center of a Bruker Micro2.5 gradient system when attached to the MICWB40 probehead and inserted into this gradient system. This is necessary to ensure that the visible region of the sample is inside the linear region of the gradient system, avoiding imaging artifacts associated with nonlinear gradients.
Includes two RF circuits, one tunable to the nominal proton (1H) NMR frequency of 600 MHz and one tunable to the nominal phosphorus-31 (31P) NMR frequency of 243 MHz at a magnetic field strength of 14 Tesla (14T) while containing a tube of normal saline solution (154 mM NaCl in water).
The two RF circuits shall have independent tuning and matching controls, accessible via the microimaging probehead’s tuning rods. This is necessary to match the dielectric loading of tissue samples, which is needed to optimize signal-to-noise ratio in 1H MR images and 31P NMR spectra.
The coil shall be capable of simultaneous excitation and reception of 1H and 31P nuclear spins in a
14T NMR spectrometer.
The coil shall be equipped with a slotted shield to minimize electromagnetic coupling to surrounding metal while minimizing eddy currents in echo-planar (EPI) MRI experiments. This is necessary to accommodate multidimensional relaxometry experiments that use EPI to minimize acquisition time.
The coil shall interface with the MICWB40 microimaging probe’s variable temperature gas supply dewar, permitting operation over at least a temperature range from +4 C to +37 C. This is required for scanning fixed, in vitro specimens and live, perfused organoids, respectively.
The coil shall have a fixture to lock 10 mm NMR tubes at a given height to align the sample with the center of the radio-frequency coil. This fixture must be removable to permit unimpeded loading of the perfusion apparatus and other 10 mm tubes from the top of the MRI magnet.
Quantity: 1
(vi) Delivery Location:
NIH/NIA
251 Bayview Blvd STE 100 BRC Bldg.
Baltimore MD 21224
(vii) [Reserved, if needed]
(viii) FAR 52.204-7, System for Award Management, applies to this acquisition.
(ix) The provision at FAR 52.212-1, Instructions to Offerors—Commercial Items, applies to this acquisition. Add any agency-specific instructions as required.
(x) The provision at FAR 52.212-2, Evaluation—Commercial Items, applies to this acquisition.
(a) The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation represents the best value to the Government, price and other factors considered.
(b) Evaluation Factors:
• Price
• Technical capability
• Past performance
• Delivery schedule
(c) A written notice of award or acceptance of an offer, issued within the time specified in the offer, shall result in a binding contract without further action by either party. The Government reserves the right to accept any offer before the expiration date.
(xi) FAR 52.212-4, Contract Terms and Conditions—Commercial Items, applies to this acquisition.
(xii) Additional contract requirements or terms and conditions, as determined necessary by the Contracting Officer and consistent with customary commercial practices:
(None)
(xiii) The Defense Priorities and Allocations System (DPAS) is (not applicable).
(xiv) Submission Requirements:
Responses must include sufficient information to demonstrate the offeror’s capability to provide the required product or service. Quotes shall include, at a minimum:
• Unit and total price
• Shipping and handling costs
• Delivery timeframe after award
• Delivery terms
• F.O.B. point (destination or origin)
• Product or catalog numbers (if applicable)
• Product/service description
Additional evaluation considerations may include past performance, warranty, lifecycle cost, maintenance availability, and environmental or energy efficiency.
Responses must include the Unique Entity Identifier (UEI), Taxpayer Identification Number (TIN), and business size certification. All offerors must be actively registered in the System for Award Management (SAM) at www.sam.gov.
http://www.sam.gov/
All responses must be received by (December 1, 2026, 2PM, EST) and must reference solicitation number 75N98027Q00089/PCA-NIA-01610. Responses may be submitted electronically to johnsonjr@mail.nih.gov.
(xv) Point of Contact:
John Johnson, Program Specialist, johnsonjr@mail.nih.gov 667-312-5580.
mailto:johnsonjr@mail.nih.gov mailto:johnsonjr@mail.nih.gov
PURCHASE DESCRIPTION
1. Statement of Need and Purpose: The purpose of this acquisition is to procure two wireless fiber photometry systems. The Neuroimaging Research Branch’s Biobehavioral Imaging & Molecular Neuropsychopharmacology Section has been performing optogenetics and fiber photometry experiments in rodents. In a new effort, the lab will extend these measures to non-tethered behaving rodents. The fiber photometry systems should be wireless and able to drive up to two LED light sources and collect fiber photometry from 1 photosensors per wireless headstage.
2. Background Information and Objective:
The goal of the Biobehavioral Imaging and Molecular Neuropsychopharmacology Section is to better understand the neurobiological antecedents of illicit drug use and abuse, the neuronal consequences of short and long-term drug use and the potential reversibility of these neuroadaptations. The acquisition of these fiber photometry systems will allow the lab to perform fiber photometry in rodents using novel designer reporters developed in collaboration with the NIDA IRP’s Genetic Engineering and Viral Vector Core. In further collaborative efforts, these methods are also focused on manipulating and measuring, simultaneously behavior and neuronal activity in rodents with cell-type specificity and combined this with simultaneous PET imaging.
3. Generic Name of Product: Wireless Fiber Photometry Systems
4. Purchase Description:
• 2 Base Stations for wireless fiber photometry system
• 2 Wireless Photometry Headstages - ferrule 2.5 mm - 1 integrated photodetector and 2 integrated LEDs. With battery A (40mAh).
• 2 Wireless Photometry Headstages - ferrule 2.5 mm - 1 integrated photodetector and 2 integrated LEDs. With battery A (40mAh).
• 1 Battery Charger for wireless fiber photometry
• 2 Non-functional Headstages for wireless fiber photometry, to fit ferrule 2.5 mm
• 10 Mono Fiberoptic Cannulae
• 1 Mid performance workstation
• 1 Neuroscience Console
4. Salient characteristics
• Must be wireless, head mounted units with 40 mAh batteries.
• Must have 2.5 mm ferrule size with integrated 1 photodetector and two LEDs
• Wavelength should be 400-410, 460-480, 500-540, 555-570, 590-650.
• Must be compatible with Doric photometry software
5. Quantity: Two wireless fiber photometry systems
Version 11-30-2016-1
FAR Part 11—Describing Agency Needs
6. Delivery Date: Delivery should be within 10 weeks upon contract award.
7. Period of Performance: One-year warranty for system repairs to include the cost of parts and labor.
8. Option(s): None
1. Statement of Need and Purpose:
The purpose of this acquisition is to procure, deliver, de-install obsolete hardware, and fully install a equivalent modern replacement, medical-grade surgical lighting—the Baxter/Hill-Rom Helux Pro Surgical Light for the NIA CRU procedure suite. This system will restore full operational readiness, ensure strict adherence to clinical safety and regulatory standards, and enhance procedural documentation capabilities.The NIA CRU requires replacement of the failing surgical lighting fixture to maintain continuity of clinical operations. Medical procedure guidelines, clinical biosafety mandates, and Institutional Review Board (IRB) approved protocol safety guidelines dictate that invasive biopsy procedures cannot be conducted without adequate, shadow-free, high-intensity surgical illumination.
Specific operational needs include: Critical clinical continuity: Biopsy procedures cannot be performed without a reliable surgical light. Any suspension of these procedures immediately halts specimen collection across multi-year intramural protocols, delaying translational research milestones and participant visits. Procedural precision & patient safety: Core biopsies require fine-field visualization to accurately isolate muscle fascia, avoid vascular structures and peripheral nerve branches, ensure adequate local anesthetic infiltration, and achieve rapid hemostasis.
High-Definition imaging and procedure archiving: A high-definition (4K) integrated optical system is necessary to record and display procedures in real time for clinical oversight, quality control, standardization across study coordinators and proceduralists, and educational review.
Manufacturer serviceability and long-term reliability: The CRU requires an active-production system backed by multi-year OEM warranty coverage and comprehensive service agreements (Protection+) to eliminate unexpected equipment downtime.
2. Background Information and Objective:
The National Institute on Aging (NIA), Intramural Research Program (IRP), operates the Clinical Research Unit (CRU) located at the MedStar Harbor Hospital campus in Baltimore, Maryland.
The CRU serves as the primary dedicated clinical facility supporting human longitudinal and translational aging research protocols, including the Baltimore Longitudinal Study of Aging (BLSA), the Genetic and Epigenetic Signatures of Translational Aging Laboratory Testing (GESTALT) study, and specialized clinical trials investigating age-related functional decline and metabolic disorders.
A cornerstone of these intramural clinical protocols involves invasive outpatient biopsy procedures—specifically percutaneous skeletal muscle biopsies, subcutaneous adipose tissue biopsies, and dermal skin punch biopsies. These procedures provide vital biospecimens for cellular, molecular, and physiological characterization of human aging.
The existing ceiling-mounted surgical lighting system currently deployed in the CRU procedure suite has reached the end of its useful service life (End-of-Life / EOL). The legacy unit is experiencing persistent operational failures. Critical replacement parts are no longer manufactured or supported by the original equipment manufacturer (OEM), rendering the existing unit non-serviceable. Because medical-grade illumination is a non-negotiable safety and operational prerequisite for procedural asepsis, precise anatomical depth perception, tissue differentiation, and hemostasis, the current state presents an unacceptable clinical risk and threatens immediate disruption to approved NIA protocol timelines.
3. Generic Name of Product:
Surgical light
4. Purchase Description:
Baxter/Hill-Rom Helux Pro Surgical Light (replacement/upgrade)
5. Salient characteristics
• Medical-Grade LED Lighthead: High-intensity, shadow-free LED surgical lighting designed for outpatient minor surgical and invasive biopsy procedures.
• Tissue Discrimination & Color Fidelity: High Color Rendering Index (CRI≥95) with optimized deep-red rendering (R9≥90) for precise differentiation between muscle fascia, adipose tissue, dermal planes, and microvascular structures.
• Thermal Management: Cool-beam LED technology with minimal radiant heat dissipation into the surgical field to prevent tissue desiccation and patient discomfort.
• Mechanical Positioning: Ceiling-mounted single-arm suspension featuring 360° continuous rotation and drift-free counterbalance positioning.
6. Quantity: 1 EA
7. Delivery Date: As soon as possible
8. Period of Performance: N/A –
9. Option(s): N/A
• Integrated In-Lighthead 4K Camera: Center-mounted, sterile-field optical 4K camera fully integrated into the lighthead housing without external dangling cables.
• Optical Zoom & Focus: Remote or sterile-handle controllable zoom and motorized autofocus capable of deep-cavity and surface procedural visualization.
• Dual-Channel High-Definition Recording: Dedicated video management unit capable of simultaneous dual-channel recording of procedure video and ancillary data feeds for research compliance and quality control.
• DICOM-Compliant Surgical Display: 55-inch wall-mounted, medical-grade 4K/UHD monitor supporting DICOM imaging standards for team-wide, uninhibited visualization.
• Centralized Video Routing Core: Rack-mounted processing engine (115V) supporting low-latency routing of 4K60 video signals across long runs via fiber-optic HDMI.
• Touchscreen Room Controller: Wall-mounted 21-inch clinical touchscreen interface providing integrated control over lighthead intensity, camera movement/recording, and video signal switching.
• Safe De-installation: Certified removal and disposal/return of existing legacy, non-serviceable ceiling-mounted surgical lighting without structural damage.
• Turnkey Facility Integration: Standardized single-point ceiling mounting kit, structural verification, and in-wall/conduit standard and fiber-optic cabling packages.
• OEM Warranty & Comprehensive Service Support: Minimum 1-year standard OEM warranty backed by multi-year (3-year lighthead / 4-year integrated system) comprehensive technical maintenance, hardware replacement, and software support agreements.
1. Statement of Need and Purpose: This request covers the purchase of a proton-phosphorus microimaging coil for our 14 Tesla NMR spectrometer. This coil is needed for the combined bioenergetic and structural study of perfused brain organoids, a model system for research on Parkinson’s disease and other age-related neurodegenerative conditions.
2. Background Information and Objective: Organoids are laboratory-grown aggregates of cells that mimic the properties of tissues in live animals and humans, providing a simple, inexpensive platform for basic research that is more realistic than cells grown in traditional, two-dimensional culture. In NIA, we are using brain cell organoids to investigate the structural and bioenergetic effects of normal aging and age-associated neurodegenerative diseases. Proton magnetic resonance imaging (1H MRI) and phosphorus-31 nuclear magnetic resonance spectroscopy (31P NMR) provide a non-destructive means of evaluating microstructure and mitochondrial function in organoids that can be applied longitudinally, following changes that occur with maturation.
Unfortunately, with our current apparatus, we are unable to perform 1H MRI and 31P NMR experiments concurrently, since we are forced to switch configuration repeatedly between the 1H-only radio-frequency (RF) coil on our microimaging probehead and a high-resolution NMR probehead equipped with a 31P RF coil. Each change between 1H MRI and 31P NMR requires removing the perfusion apparatus from the magnet and not only wastes time but also jeopardizes the stability of the organoids. By purchasing a dual-tuned, 1H/31P RF coil for our microimaging probehead, we will circumvent these problems and allow frequent monitoring of cell viability by 31P NMR during long, complex microimaging experiments.
3. Generic Name of Product: 10 mm 1H/31P microimaging coil for 14 Tesla MRI
4. Purchase Description: MicWB40 Selective Imaging 31P/1H double resonance 10mm RF insert designed for separate 1H and 31P, or double frequency experiments., Bruker Biospin, Inc. product code PI2591_DX/HP (MicWB40-INS-DR-31P/1H-10mm).
5. Salient characteristics:
a. Nominal inner diameter of 10 mm to accommodate samples in standard 10 mm OD glass NMR tubes (needed for compatibility with home-built organoid perfusion system, which uses these tubes).
b. Interfaces mechanically with existing Bruker MICWB40 microimaging probehead, sliding onto and matching the screw holes on the probehead while engaging the probehead’s coaxial connector and tuning rods.
c. The position of the radio-frequency (RF) coil center must align with the center of a Bruker Micro2.5 gradient system when attached to the MICWB40 probehead and inserted into this gradient system. This is necessary to ensure that the visible region of the sample is inside the linear region of the gradient system, avoiding imaging artifacts associated with nonlinear gradients.
d. Includes two RF circuits, one tunable to the nominal proton (1H) NMR frequency of 600 MHz and one tunable to the nominal phosphorus-31 (31P) NMR frequency of 243 MHz at a magnetic field strength of 14 Tesla (14T) while containing a tube of normal saline solution (154 mM NaCl in water).
e. The two RF circuits shall have independent tuning and matching controls, accessible via the microimaging probehead’s tuning rods. This is necessary to match the dielectric loading of tissue samples, which is needed to optimize signal-to-noise ratio in 1H MR images and 31P NMR spectra.
f. The coil shall be capable of simultaneous excitation and reception of 1H and 31P nuclear spins in a 14T NMR spectrometer.
g. The coil shall be equipped with a slotted shield to minimize electromagnetic coupling to surrounding metal while minimizing eddy currents in echo-planar (EPI) MRI experiments.
This is necessary to accommodate multidimensional relaxometry experiments that use EPI to minimize acquisition time.
h. The coil shall interface with the MICWB40 microimaging probe’s variable temperature gas supply dewar, permitting operation over at least a temperature range from +4 C to +37 C. This is required for scanning fixed, in vitro specimens and live, perfused organoids, respectively.
i. The coil shall have a fixture to lock 10 mm NMR tubes at a given height to align the sample with the center of the radio-frequency coil. This fixture must be removable to permit unimpeded loading of the perfusion apparatus and other 10 mm tubes from the top of the MRI magnet.
4. Quantity: 1
5. Delivery Date: Approximately 8 months ARO
6. Period of Performance: Purchase includes warranty for at least one year.
7. Option(s): N/A
| Request for quotations |
| Request number |
| Date issued |
| Requisition/purchase request number |
| CERT. FOR NAT. DEF. UNDER BDSA REG. 2 AND/OR DMS REG. 1 |
| Issued by |
| For information call |
| Name |
| Telephone number |
| Area code |
| number |
| Deliver by (date) |
| Delivery |
| To: |
| Name |
| Company |
| Street address |
| City |
| State |
| Zip code |
| Destination |
| Name of consignee |
| Street address |
| City |
| State |
| Zip code |
| Please furnish quotations to the issuing office in block 5a on or before close of business |
| Schedule |
| Discount for prompt payment |
| 10 calendar days (%) |
| 20 calendar days (%) |
| 30 calendar days (%) |
| Calendar days |
| Number |
| Percentage |
| Name and address of quoter |
| Name of quoter |
| Street address |
| County |
| City |
| State |
| Zip code |
| Signature of person authorized to sign quotation |
| Date of quotation |
| Signer |
| Name |
| Telephone |
| Area code |
| Number |
Title
| AUTHORIZED FOR LOCAL REPRODUCTION Previous edition not usable |
| Standard form 18 (Rev. 6/1995) |
| 75N98027Q00038SB.pdf |
| COMBINED SYNOPSIS / SOLICITATION/ (Brand Name or Equal) |
| (v) Description of Requirement: |
| SALIENT CHARACTERISTICS: |
| (vi) Delivery Location: |
| (b) Evaluation Factors: |
| (xiv) Submission Requirements: |
| (xv) Point of Contact: |
Purchase description for 10 mm 14T 1H 31P microimaging coil.pdf
File details come from the government source that posted it. Updated .