Amendment 2 (Supporting).pdf

PDF 7 MB Posted

Attached to
Installation of Voice Over IP System, Sacred Oaks, Healing Center, Davis, California
Solicitation number
75H70320Q00002
Issued by

View the file

Other files

File Type Posted
Amend 0004.pdf PDF
Amendment 0003.pdf PDF
SF30 (Amendment 0002) (07.28.20).pdf PDF
Amendment 0001.pdf PDF
75H70320Q00002.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Request for Quotation 75H703.20.Q.00002, Amendment 0002

Subject modifications incorporates the following attachments:

1. Contractor Questions and Government Responses;

2. 275116_Public_Address_Systems_Public_Address_System_ 16675865

3. SacredOaks-VoIP=PWS (07.28.20 1406). This version superseded the previously issues PWS in its entirety.

Contractor(s) must acknowledge receipt of thie Amendment by completing Blocks 8, 15A, 15B, & 15C. Return this and any other Amendment(s) signed, along with your package.

rrosas Highlight

225 E. Germann Road Suite 201 Gilbert, AZ 85297 602-956-0112 - Phone 602-956-2272 - Fax

SPEC SECTION NO:

SUBMITTAL NO:

JOB: 17908 REVISION NO:

Northern California Youth Regional Treatment Center SENT DATE:

Davis, CA

SPEC SECTION TITLE:

SUBMITTAL TITLE:

CONTRACTOR: Contractor's Stamp M. Greenberg Construction, Inc.

Scott Taylor M. GREENBERG CONSTRUCTION, INC.

REVIEWED BY:

DATE:

ARCHITECT: Architect's Stamp JSRa

ENGINEER: Engineer's Stamp

SUBMITTAL

275116

2/1/2019

Public Address Systems Public Address System

2/1/2019

No Exceptions Taken.

REVIEWED

RESUBMIT PER COMMENTS

NOT REVIEWED / NOT A REQUIRED SUBMITTAL

REFER TO COMMENT SHEET

This review performed by Bernhard TME, LLC, is only for general conformance with the design concept of the project and general compliance with the information provided in the contract documents. Corrections or comments made on the submittal and/or shop drawings during this review do not relieve the

Contractor from compliance with the requirements of the plans, specifications, and other contract documents. Review of a specific item shall not indicate a review of an assembly of which the item is a component. Contractor is responsible for the following: all quantities; configuration of components;

dimensions to be confirmed and correlated at the jobsite; information that pertains solely to the fabrication process or to the means, methods, techniques, sequences, and procedures of construction; coordination of the work with that of all other trades; and, for performing all work in a safe and satisfactory manner.

DATE: BY:

February 12, 2019

REVIEW IS FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT AND CONTRACT

DOCUMENTS. MARKINGS OR COMMENTS SHALL NOT BE CONSTRUED AS RELIEVING THE

CONTRACTOR FROM COMPLIANCE WITH THE CONTRACT PLANS AND SPECIFICATION,

NOR DEPARTURE THEREFROM. THE CONTRACTOR REMAINS RESPONSIBLE FOR DETAILS

AND ACCURACY, FOR CONFIRMING AND CORRELATING ALL QUANTITIES ALL QUANTITIES

AND DIMENSIONS, FOR SELECTING FABRICATION PROCESSES, FOR TECHNIQUES OF

CONSTRUCTION AND ASSEMBLY, FOR COORDINATION OF HIS WORK AND THAT OF ALL

OTHER TRADES, AND FOR PERFORMING HIS WORK IN A SAFE AND SATISFACTORY

MANNER.

SHOP DRAWING / SUBMITTAL REVIEW

NO EXCEPTIONS TAKEN REVISE AND RESUBMIT

APPROVED AS NOTED NOT APPROVED

JOHNSON, SMITTHIPONG & ROSAMOND ASSOCIATES, INC.

5210 E. WILLIAMS CIRCLE #600 TUCSON, AZ 85711 PH: (520) 547-7904

BY: DATE: _rharrington 02/12/2019

Northern CA Youth

Regional Treatment Center

PUBLIC ADDRESS SYSTEM

Submittal No. 001.1

Spec Section 275116-1

3D Job# 3D-18-151

Project Manager: Tony Turturici

3D Technology Services

11365 Sunrise Gold Circle

Rancho Cordova, CA 95742 www.3ddatacom.com

P: (916) 859-9111

F: (916) 859-9110

3D Technology Services -11365 Sunrise Gold Circle -Rancho Cordova, CA 95742

Project:

Northern California Youth Regional Treatment Center (NCYRTC) 33100 County Road 31 Davis, CA 95616

Architect of Record:

Johnson Smitthipong & Rosamond 5210 E. Williams Circle #600 Tucson, AZ 85711

Electrical Engineer of Record:

Bernhard TME Engineering LLC.

2920 North Swan Road Suite #207 Tucson, AZ 85712

General Contractor:

M. Greenberg Construction, Inc.

225 E. Germann Road Suite #201 Gilbert, AZ 85297

Electrical Contractor:

3D Technology Services 11365 Sunrise Gold Circle Ranch Cordova, CA 95742

11. All cabling shall be provided and installed in strict accordance with NEC 725 and all other NEC requirements.

12. It shall be the responsibility of the Contractor to maintain minimum separation of Class 2 conductors from electric light, electric power, Class 1, and other circuits in strict accordance with the requirements of NEC 725.

13. It shall be the sole responsibility of the Contractor to eliminate crosstalk or any other disturbance to any voice or data system in the facility.

14. All audio amplifiers and other audio sources shall be UL listed for Class 2 operation at 25V and shall be durably and permanently marked for Class 2 operation.

15. All public address conductors shall be suitable for the specific application, UL listed for Class 2 circuits, and selected in strict compliance with NEC requirements.

16. All public address conductors shall be plenum rated.

17. All public address conductors shall be selected in strict accordance with the audio amplifier manufacturer’s written instructions.

1.3 ACTION SUBMITTALS

A. Product Data: For each type of product indicated. Include rated capacities, operating characteristics, and furnished specialties and accessories. Reference each product to a location on Drawings.

1. Submittals shall be marked to show specific model numbers and configurations.

2. Submittal shall include a complete bill-of-material that accurately identifies quantities of all devices and components.

3. Submittal shall include technical data on conductors for all field circuits.

B. Shop Drawings: Include plans, elevations, sections, details, and attachments to other work.

1. Diagrams for cable management system.

2. System labeling schedules, including electronic copy of labeling schedules that are part of the cable and asset identification system of the software specified in Parts 2 and 3.

3. Sufficient information, clearly presented, shall be included to determine compliance with plans and specifications.

4. Include manufacturer's name(s), model numbers, ratings, power requirements, equipment layout, device arrangement, complete wiring point-to-point diagrams, and conduit layouts.

5. Provide power supply load calculations.

6. Provide standby power calculations.

7. Amplifier, load, and wire loss calculations for each and every audio circuit.

8. Show layout, configurations, and terminations.

9. Cable Administration Drawings: As specified in "Identification" Article.

C. Other Action Submittals:

1. Project planning documents as specified in Part 3.

2. Manuals

a. Submit simultaneously with the shop drawings, complete operating and maintenance manuals listing the manufacturer's name(s), including technical data sheets.

Attached

Attached Attached

Corporate Office:

Rancho Cordova, CA 95742-6512 916-859-9111 www.3ddatacom.com

CSLB# 757157

DIR# 1000000172

Project: Northern CA Youth Regional Treatment Center

Public Address System

Section-275116 Bogen control panel & amplifiers (1). Tab#1 Section-275116 Hard cap cut-in ceiling speakers (13). Tab#1 Section-275116 2X2 lay-in drop ceiling speakers (36). Tab#1 Section-275116 Volume Control Devices (4). Tab#1 Section-275116 Belden 16-2 Wire. Tab#2 Section-275116 Belden 18-2 Wire. Tab#2 Section-275116 Floor Plan Layout. Tab#3

11365 Sunrise Gold Circle-Rancho Cordova, CA 95742-P: (916) 859-9111-F: (916) 859-9110

Project: Northern California Youth Regional Treatment Center Davis, CA 95616 3D Technology Job# 3D-18-151

Northern California Youth Regional

Treatment Center

Public Address System

SECTION: 275116-1

Tab 1

Field Devices

Corporate Office:

Rancho Cordova, CA 95742-6512 916-859-9111 www.3ddatacom.com

CSLB# 757157

DIR# 1000000172

Project: Northern CA Youth Regional Treatment Center

ATLAS SOUND

Bogen PCM2000 Amplifier

Commercial Attenuators AT Series

DT22 Drop Tile Speaker Package

SD72 Series - 8" Preassembled Speaker Package

The PCMSYS3 is a pre-assembled and tested 3-zone PCM2000 system with a PCMPS2 power supply. Use it right out of the box for 1 to 3 zone applications or expand it with other PCM modules. Provides all the same great features found in the PCM2000 zone paging system.

Paging Features:

• Provides 1 to 3 paging zones

• Expandable up to 99 zones*

• Up to 32 programmable paging zone groups

• Emergency All-Zone Override

Paging input

• Two-way Communications*

• 250W power handling capacity

• Code Calling

• Background Music distribution

• Works with systems that are central- or self-amplified

• Drives up to 40 self-amplified speakers per zone module

• Night Ringer, 90V and contact closure

• Real-time Clock & Master Clock Synchronization*

• Time Triggered Signaling Tones*

Installation Features:

• Operates with 70V and self-amplified (24V) paging systems

• Universal Telephone Interface allows simple connection to loop and ground start trunks, paging ports, and to analog 90V station lines

• RJ11 jacks & terminal blocks

• Relay driver outputs

• Two C-form relay contacts

• Setup tone

• Program system features via DTMF

• Wall-mountable

• Rack-mount adapters (optional)

• FCC Part 68 registered

• UL60950 listed

50 Spring St., Ramsey, NJ 07446 USA Tel: 201-934-8500 • Fax: 201-934-9832 www.bogen.com 54-9292-01B 1301 Specifications subject to change.

RPK84

Rack Mount

Kit

RPK88

Rack Mount Kit

PCMTIM PCMCPU

PCMZPM PCMTBM

Telephone Interface Module

Central Processor Module

3-Zone Paging Module

Talk Back Module (optional)

PCM2000 Modules

RACK MOUNT ACCESSORIES

Ready-To-Go, right out of the box.

Contains:

1 PCMTIM - Telephone Interface module 1 PCMCPU - Central Processor module 1 PCMZPM - 3-Zone Paging module 1 PCMPS2 - System Power Supply

Expansion:

• Add PCMZPM modules for up to 9 zones.

• Add PCMTBM module for talk back and realtime clock/tone applications.

• Add satellite assemblies for up to 99 zones.

* Requires additional PCM modules beyond PCMSYS3 contents www.bogen.com/documentindex

FREE DESIGN

GUIDE

Download online at:

PCM2000

CONFIGURATION

GUIDE

To download complete PCM2000 Specifications, visit our website at:

www.bogen.com/products/telephonepaging

1601 JACK MCKAY BLVD. ENNIS, TEXAS 75119 U.S.A.

TELEPHONE: (800) 876-3333

FAX (800) 765-3435 AtlasSound.com 1/5

A tl as

S ou nd L

.P . A ll ri gh ts r es er ve d.

A tl as

S ou nd a nd S tr at eg y

S er ie s ar e tr ad em ar ks o f A tl as

S ou nd L

.P

A ll ot he r tr ad em ar ks a re t he p ro pe rt y of t he ir r es pe ct iv e ow ne rs

A

TS

R ev

D

0/

Commercial Attenuators AT Series, E408 Series

Features

• Models Feature a Range of Attenuation Steps (1.5dB or 3dB Steps) as Well as Continuous to Meet Application and Budget Requirements

• Wall Plates are Stainless Steel with Stamped and Filled or Screen Printed Dial Scale, and a Skirted Black Knob (White and Ivory Plastic Plates with Matching Skirted Knobs Also Available in Decora Style-D Series Only)

• Popular Rack Mount Attenuator Versions are Available on the AT and E408 Series for Mounting on to Blank Panels in Equipment Cabinets

• All AT Models Mount into Most 1-Gang E.O. Boxes. (23⁄4" Deep)

• AT and E408 Series are UL Listed

Genenal Description

AT Series Industry Standard Auto Transformer. High-quality auto transformer series provides the advantages of excellent frequency response, low insertion loss and reliable performance for volume control application in 25V/70.7V systems. Attenuation is accomplished in ten make before break steps plus positive Off position. (No stop between maximum and Off position to prevent switch damage). Contacts are silver plated for noise-free operation. Features a removable terminal block. Includes stainless steel plate, with stamped and filled or screen printed dial scale and a skirted black knob. (White and ivory plastic plates with matching skirted knobs also available in Decora style-see AT model description chart).

E408 Auto Transformer with Precision Level Control. Specially designed for attenuation in masking and sound reinforcement systems where fine tuning of level control is required. Employs a ten-position, non-shorting rotary switch without stop. Attenuation rate is 1.5dB per step. (All other specifications are the same as the AT Series including the UL listing).

PA Series Priority Paging Option. Priority paging feature by-passes the effect of the attenuator to provide program level selection of individual emergency and paging signals at the amplifier. Option is available on all AT attenuators. The SPDT relay is operated with 24VDC at 10mA. Includes protective relay cover to ensure lasting trouble-free performance. Terminations to the relay and attenuator are made via a removable terminal block. (All other specifications except for dimensions are the same as selected AT models).

RM Series Rack Mount Option. For attenuation convenience of rack-mounted equipment in cabinets and consoles, the AT, E408 Series attenuators are available without mounting plate for rack panel installation. Attractive matte black polycarbonate dial scale overlay with adhesive backing replaces the mounting plate. Includes skirted black knob. Overlay size is 29 square (51mm). (To order, simply add RM after the selected attenuator model number. Example: AT10-RM or AT10- PARM.) (Dial scale overlays to retrofit existing installations are available, see Model HX23.)

AT10 / AT35 / AT100 Series

AT10 / AT35 / AT100 Series Face Plate Options Attenuators are available in Classic Stainless or Decora(Decora available in Ivory or White)

E408-100

RM Series

HX21-B HX22-W

Replacement Knobs

FAX (800) 765-3435 AtlasSound.com 2/5

A tl as

S ou nd L

.P . A ll ri gh ts r es er ve d.

A tl as

S ou nd a nd S tr at eg y

S er ie s ar e tr ad em ar ks o f A tl as

S ou nd L

.P

A ll ot he r tr ad em ar ks a re t he p ro pe rt y of t he ir r es pe ct iv e ow ne rs

A

TS

R ev

D

0/

Specfications

AT10-(PA)

Power Rating * 10 Watts

UL Listing

Attenuation Per Step 3dB

Total Attenuation 33dB**

Insertion Loss .4dB

Plate Size 1 gang

Resistance None

AT35-(PA)

Power Rating * 35 Watts

UL Listing

Attenuation Per Step 3dB

Total Attenuation 27dB

Insertion Loss .6dB

Plate Size 1 gang

Resistance None

AT100-(PA)

Power Rating * 100 Watts

UL Listing

Attenuation Per Step 3dB

Total Attenuation 27dB

Insertion Loss .6dB

Plate Size 1 gang

Resistance None

E408-100

Power Rating * 100 Watts

UL Listing

Attenuation Per Step 1.5dB

Total Attenuation 15dB

Insertion Loss .6dB

Plate Size 1 gang

Resistance None

* Continuous ** These units have two steps of 6dB before off position.

Note: Attenuation curve is steeper for a 25-volt line

Architect and Engineer Specifications

AT Series Attenuator(s) shall be Atlas Sound AT Series Model ____________ auto transformer or approved equal. The power rating shall be __________ and attenuation range shall be _________dB. Attenuation per step for AT-____ shall be 8 steps of 3dB and 6dB each for the last two positions. Attenuator shall be a step type control with a positive off position. There shall be no stop between the maximum and off positions (AT Series only). Switch shall have silver plated contacts to eliminate noise and contact loss. All terminations must be made via a removable terminal block. Unit(s) shall be supplied with one of the following single gang face plates to be noted by model number suffix: Standard stain less steel faceplate (with dial scale to indicate attenuator position), Decora style plastic face plate-Ivory color, Decora style plastic face plate-White color. All models are designed to mount in a standard E.O. box.

E408 UL Listed attenuator shall be Atlas Sound Model E408-100 auto transformer or approved equal. The power rating shall be 100W. The at tenu ation per step shall be 1.5dB. Unit shall be a step type control with a positive off position. There shall be no stop between the maximum and off positions. Switch shall have silver plated contacts to elimi nate noise and contact loss. The attenuator shall be mounted to a standard gang stainless steel wall plate which mounts to a standard E.O. box.

RM Option Attenuator shall be Atlas Sound Model ____________ [(AT, E408 (-RM)] or ap proved equal. Face plate shall be replaced by an adhesive matte black poly car bon ate dial scale escutcheon for attachment to a rack mount panel. Escutcheon size shall be 2" SQ.

PA Option Specified AT Series attenuators include a priority relay. Relay shall be an SPDT, 24 VDC type securely mounted to the attenuator assembly wired at the factory. Relay shall include a protective cover.

AT10 (dc) (-PA) (-RM) AT35 (dc) (-PA) (-RM) AT100 (dc) (-PA) (-RM)

(-PA)

Priority

Announce Circuit Option

(-RM)

Rack

Mount Option

Faceplate Options:

d = D - Decora Style Faceplate

Ivory and White inserts, trim ring and knobs icluded.

If there is not the above 1 letter suffix, the attenuator is shipped with the standard stainless steel faceplate or is the RM version without a faceplate.

FAX (800) 765-3435 AtlasSound.com 3/5

A tl as

S ou nd L

.P . A ll ri gh ts r es er ve d.

A tl as

S ou nd a nd S tr at eg y

S er ie s ar e tr ad em ar ks o f A tl as

S ou nd L

.P

A ll ot he r tr ad em ar ks a re t he p ro pe rt y of t he ir r es pe ct iv e ow ne rs

A

TS

R ev

D

0/

AT Series

Dimensional Specifications Plate Mounted Attenuators

MODEL A B C D E

AT10 41⁄2" 21⁄8" 23⁄4" 23⁄4" 13⁄4"

AT10-PA 41⁄2" 21⁄8" 23⁄4" 23⁄4" 13⁄4"

AT35 41⁄2" 21⁄8" 23⁄4" 23⁄4" 13⁄4"

AT35-PA 41⁄2" 21⁄8" 23⁄4" 23⁄4" 13⁄4"

AT100 41⁄2" 21⁄2" 23⁄4" 23⁄4" 13⁄4"

AT100-PA 41⁄2" 21⁄2" 23⁄4" 23⁄4" 13⁄4"

E408-100 41⁄2" 25⁄8" 23⁄4" 23⁄4" 13⁄4"

A

C E

B

D

FAX (800) 765-3435 AtlasSound.com 4/5

A tl as

S ou nd L

.P . A ll ri gh ts r es er ve d.

A tl as

S ou nd a nd S tr at eg y

S er ie s ar e tr ad em ar ks o f A tl as

S ou nd L

.P

A ll ot he r tr ad em ar ks a re t he p ro pe rt y of t he ir r es pe ct iv e ow ne rs

A

TS

R ev

D

0/

WIRING - AT Series

Each terminal will hold up to 2-16AWG stranded wire.

For larger wires or home run situations, a small length of wire and a wire nut are recommended.

Attach wire according to label on terminal black as shown below (Non- PA Models will not have the "VDC+" and "VDC-" terminals).

* Install the unit with the terminal block on top. This will ensure that the off position is on the bottom.

70.7V AMP-

PS

+ 24VDC

Speaker with 70.7V

Transformer

-PA

Models

Only S P K

S P K

V D C

A M P

V D C

A M P

FAX (800) 765-3435 AtlasSound.com 5/5

A tl as

S ou nd L

.P . A ll ri gh ts r es er ve d.

A tl as

S ou nd a nd S tr at eg y

S er ie s ar e tr ad em ar ks o f A tl as

S ou nd L

.P

A ll ot he r tr ad em ar ks a re t he p ro pe rt y of t he ir r es pe ct iv e ow ne rs

A

TS

R ev

D

0/

Wiring - (-Pa) Priority Attenuators

Relay Specifications

COIL VOLTAGE: 24VDC

COIL CURRENT: 10MA

CONTACTS: SPDT-2AMP Rating Relay Has a Protective Cover

Power Switching Req. For - Pa Attenuators

FAX (800) 765-3435 AtlasSound.com 1/2

A tl as

S ou nd L

.P . A ll ri gh ts r es er ve d.

A tl as

S ou nd a nd S tr at eg y

S er ie s ar e tr ad em ar ks o f A tl as

S ou nd L

.P

A ll ot he r tr ad em ar ks a re t he p ro pe rt y of t he ir r es pe ct iv e ow ne rs

A

TS

R ev

A

/1

DT22

2' x 2' Drop Tile Speaker Package

DT22

Features

• All In One, Pre-Assembled Unit Drops Into Ceiling Grids to Reduce

Installation Time and Costs

• Solid White Panel with Punched Speaker Grille Blends in with Most

Acoustic Ceiling Tiles

• Standard 8" Speaker with Built-In 25V / 70.7V Transformer

• UL1480 / UL2043

Application

Installer friendly Atlas Sound DT22 provides clear paging and background music in a labor saving package. Ideal for use in shopping malls, department stores, and anywhere large quantities of loudspeakers are to be utilized.

General Description

The Atlas Sound DT22 2' x 2' drop in speaker system simplifies loudspeaker installation by providing an all in one speaker package in acoustic ceiling grids. The system includes the speaker / transformer, enclosure, and grille. Enjoy clear, crisp paging and background music from the installation friendly DT22 without compromising building cosmetics.

Specifications

Frequency Response 100Hz - 5kHz

Dispersion 105°– 2kHz Octave Band (-6dB)

Sensitivity (1W/1m) 96dB

Speaker 8" Dual Cone

Magnet Weight 10oz (283g)

Length 23.9" (607mm)

Width 23.9" (607mm)

Depth 4.53" (115mm)

Weight 11.3 lbs (5.125kg)

Color White

Architect and Engineer Specifications The loudspeaker, transformer, baffle and enclosure shall be the Atlas Sound 2' x 2' drop in speaker system Model DT22. The loudspeaker shall be an 8" dual cone type with an integral 25V / 70.7V matching transformer. Power taps to include .25, .5, 1, 2, & 4 Watt for 25V and 70.7V systems. The assembly to include a speaker enclosure mounted to a 2' x 2' white metal panel.

FAX (800) 765-3435 AtlasSound.com 2/2

A tl as

S ou nd L

.P . A ll ri gh ts r es er ve d.

A tl as

S ou nd a nd S tr at eg y

S er ie s ar e tr ad em ar ks o f A tl as

S ou nd L

.P

A ll ot he r tr ad em ar ks a re t he p ro pe rt y of t he ir r es pe ct iv e ow ne rs

A

TS

R ev

A

/1

DT22 Frequency Response

Frequency (Hz)

Frequency (Hz) Octave Smoothing = 30.0%

O h m s

DT22 Impedance

FAX (800) 765-3435 AtlasSound.com 1/3

A tl as

S ou nd L

.P . A ll ri gh ts r es er ve d.

A tl as

S ou nd a nd S tr at eg y

S er ie s ar e tr ad em ar ks o f A tl as

S ou nd L

.P

A ll ot he r tr ad em ar ks a re t he p ro pe rt y of t he ir r es pe ct iv e ow ne rs

A

TS

R ev

B

/1

SD72 Series 8" Preassembled Speaker Package

SD72

Features

• 10 oz Dual Cone Speaker Provides Familiar Response & Performance

• Quality 5 Watt Dual Voltage Transformer

• Individually Packaged for Stocking & Ordering Convenience

Applications

The SD72 is an aggressively priced, high quality speaker/transformer package suitable for almost any paging or background application including retail stores, restaurants, schools, and other institutional facilities.

General Description

The speaker used in the SD72 is the next generation of high performance cone loudspeakers, very similar to the preceding C-Series speakers. The similarity in the sonic qualities ensures that contractors and designers who have worked with the Atlas Sound C-Series in the past will know exactly what to expect when they use the SD72. Model SD72 is a dual cone, 25 Watts 8" (205mm) loudspeaker with a 10 oz. (260g) ceramic magnet. It includes a curvelinear, treated paper cone for lower harmonic distortion. The loudspeaker is also equipped with a full 1" diameter copper voice coil with a black anodized aluminum former for better power dissipation. Model SD72 operates within a frequency response range of 55Hz – 8kHz (±5dB) with a sensitivity of 97dB and a dispersion angle of 105˚. Package includes factory installed 25V/70.7V line matching transformer with tap selections ranging from .25 to 5 Watts. It mounts a wide variety of Atlas Sound round and square baffles and enclosures to meet functional and aesthetic application requirements.

Architect and Engineer Specifications

Unit shall be Atlas Sound 8" loudspeaker Model SD72 utilizing line matching transformer. It shall have a (10oz.) ceramic magnet and a seamless cone. Frequency response range shall be 55Hz–8kHz (±5dB).

Sensitivity shall be 97dB 1W/1M. Voice coil shall be black anodized aluminum to help dissipate heat, have an impedance of 8Ω and a diameter of 1" (25mm). Transformer primary voltage shall be 25V/70.7V with a frequency response range of 100Hz–10kHz (±1.5dB). Insertion loss shall not exceed 1.5dB.

All models feature standard mounting holes to accommodate the majority of Atlas Sound 8" baffles. All mounting screws are included in the package.

Model SD72 SD72W SD72WV

Size 8" (205mm) 8" (205mm) 8" (205mm)

Power Taps .25, .5, 1, 2, & 5 Watts

Sensitivity 97dB Average

Frequency Response

55Hz-19kHz (±5dB)

Dispersion 105° (2kHz Octave Band, -6dB Points

Diameter 81⁄8" (205mm) 123⁄4" (206mm) 123⁄4" (206mm)

Depth 27⁄8" (73mm)

Specifications

FAX (800) 765-3435 AtlasSound.com 2/3

A tl as

S ou nd L

.P . A ll ri gh ts r es er ve d.

A tl as

S ou nd a nd S tr at eg y

S er ie s ar e tr ad em ar ks o f A tl as

S ou nd L

.P

A ll ot he r tr ad em ar ks a re t he p ro pe rt y of t he ir r es pe ct iv e ow ne rs

A

TS

R ev

B

/1

SD72 Polars (Normalized to Zero on Axis) (-6dB)

Frequency (Hz)

M ag n it u d e (d

B

SD72 Harmonic Distortion

FAX (800) 765-3435 AtlasSound.com 3/3

A tl as

S ou nd L

.P . A ll ri gh ts r es er ve d.

A tl as

S ou nd a nd S tr at eg y

S er ie s ar e tr ad em ar ks o f A tl as

S ou nd L

.P

A ll ot he r tr ad em ar ks a re t he p ro pe rt y of t he ir r es pe ct iv e ow ne rs

A

TS

R ev

B

/1

Frequency (Hz) Octave Smoothing = 30.0%

O h m s

SD72 Impedance

Davis, CA 95616 3D Technology Job# 3D-18-151

Northern California Youth Regional

Treatment Center

Public Address System

SECTION: 275116-1

Tab 2

Field Wiring

Part Number: 5200UE

Security & Sound, 2 Conductor 16 AWG, BC, CMR

Product Description Security & Commercial Audio Cable, Riser-CMR, 2-16 AWG stranded bare copper conductors with polyolefin insulation, PVC jacket with ripcord

Technical Specifications MetricTDS: 5200UE

Product Overview

Environmental Space: Indoor - Riser

Suitable Applications: Data Circuits, Monitor/Detection, Control Circuits, Initiating Circuits, Notification Circuits

Physical Characteristics (Overall)

Conductor

AWG Stranding Material No. of Conductors

16 19x29 BC - Bare Copper 2

Conductor Count: 2

Conductor Size: 16 AWG

Insulation

Material Nominal Wall Thickness

PP - Polypropylene 0.008 in

Color Chart

Number Color

1 Black

2 Red

Outer Shield Material

Material

Unshielded

Outer Jacket Material

Material Nominal Diameter Nominal Wall Thickness Ripcord

PVC - Polyvinyl Chloride 0.184 in 0.017 in Yes

Construction and Dimensions

Cabling

Lay Direction Twists

Left Hand 3 twist/ft

Electrical Characteristics

Conductor DCR

Nominal Conductor DCR

4.2 Ohm/1000ft

Capacitance

Nom. Capacitance Conductor to Conductor

23 pF/ft

Inductance

Nominal Inductance

0.14 µH/ft

Current

Element Max. Recommended Current [A]

10C Temperature Rise Per conductor @ 25°C ambient: 6.25 A

Voltage

UL Voltage Rating

300 V RMS

Temperature Range

UL Temp Rating: 75°C

Operating Temp Range: -20°C To +75°C

Mechanical Characteristics

Bulk Cable Weight: 24 lbs/1000ft

Max Recommended Pulling Tension: 59 lbs

Min Bend Radius/Minor Axis: 2.0 in

Standards

NEC Articles: 800

NEC/(UL) Specification: CMR

CEC/C(UL) Specification: CMG

CPR Euroclass: Eca

Applicable Environmental and Other Programs

EU Directive 2000/53/EC (ELV): Yes

EU Directive 2003/96/EC (BFR): Yes

EU Directive 2011/65/EU (ROHS II): Yes

EU Directive 2012/19/EU (WEEE): Yes

EU Directive 2015/863/EU: Yes

EU Directive Compliance: EU Directive 2003/11/EC (BFR)

EU CE Mark: Yes

EU RoHS Compliance Date (yyyy-mm-dd): 2005-04-01

CA Prop 65 (CJ for Wire & Cable): Yes

MII Order #39 (China RoHS): Yes

Suitability

Suitability - Indoor: Yes

Flammability, LS0H, Toxicity Testing

C(UL) Flammability: FT4

UL Flammability: UL1666 Vertical Riser

UL voltage rating: 300 V RMS

Plenum/Non-Plenum

Plenum (Y/N): N

Plenum Number: 6200UH

Part Number

Variants

Item # Color Footnote

5200UE 0101000 Black

5200UE 010U1000 Black

5200UE 010Z1000 Black

5200UE 010Z1000 Black

5200UE 0061000 Blue, Light

5200UE 0061000 Blue, Light

5200UE 001U1000 Brown

5200UE 001Z1000 Brown

5200UE 001Z1000 Brown

5200UE.00152 Chrome

5200UE.00305 Chrome

5200UE.00153 Chrome

5200UE 0081000 Gray C

5200UE 008500 Gray

5200UE 008U1000 Gray

5200UE 008U500 Gray

5200UE 008Z1000 Gray

5200UE 008Z1000 Gray

5200UE 0051000 Green, Dark

5200UE 0051000 Green, Dark

5200UE 0031000 Orange

5200UE 0031000 Orange

5200UE 0021000 Red C

5200UE 0021000 Red C

5200UE 002Z1000 Red

5200UE 002Z1000 Red

5200UE 0071000 Violet

5200UE 0071000 Violet

5200UE 009U1000 White

5200UE 0091000 White

5200UE 0091000 White

5200UE 009Z1000 White

5200UE 009Z1000 White

5200UE 0041000 Yellow

5200UE 0041000 Yellow

Footnote: C - CRATE REEL PUT-UP.

© 2019 Belden, Inc

All Rights Reserved.

Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability.

Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.

All sales of Belden products are subject to Belden's standard terms and conditions of sale.

Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.

Part Number: 5300UE

Security & Sound, 2 Conductor 18 AWG, BC, Unshielded, CMR

Product Description Security & Commercial Audio Cable, Riser-CMR, 2-18 AWG stranded bare copper conductors with polyolefin insulation, PVC jacket with ripcord

Technical Specifications MetricTDS: 5300UE

Product Overview

Environmental Space: Indoor - Riser

Suitable Applications: Monitor/Detection, Control Circuits, Initiating Circuits, Notification Circuits

Physical Characteristics (Overall)

Conductor

AWG Stranding Material No. of Conductors

18 7x26 BC - Bare Copper 2

Conductor Count: 2

Conductor Size: 18 AWG

Insulation

Material Nominal Wall Thickness

PP - Polypropylene 0.008 in

Color Chart

Number Color

1 Black

2 Red

Outer Shield Material

Material

Unshielded

Outer Jacket Material

Material Nominal Diameter Nominal Wall Thickness Ripcord

PVC - Polyvinyl Chloride 0.158 in 0.017 in Yes

Construction and Dimensions

Cabling

Twists

3.4 twist/ft

Electrical Characteristics

Conductor DCR

Nominal Conductor DCR

6.5 Ohm/1000ft

Capacitance

Nom. Capacitance Conductor to Conductor

21.5 pF/ft

Inductance

Nominal Inductance

0.145 µH/ft

Current

Max. Recommended Current [A]

Per conductor @ 25°C: 5 A

Voltage

UL Voltage Rating

300 V RMS

Temperature Range

UL Temp Rating: 75°C

Operating Temp Range: -20°C To +75°C

Mechanical Characteristics

Bulk Cable Weight: 15 lbs/1000ft

Max Recommended Pulling Tension: 45 lbs

Min Bend Radius/Minor Axis: 1.5 in

Standards

NEC Articles: 800

NEC/(UL) Specification: CMR

CEC/C(UL) Specification: CMG

CPR Euroclass: Eca

Applicable Environmental and Other Programs

EU Directive 2000/53/EC (ELV): Yes

EU Directive 2003/96/EC (BFR): Yes

EU Directive 2011/65/EU (ROHS II): Yes

EU Directive 2012/19/EU (WEEE): Yes

EU Directive 2015/863/EU: Yes

EU Directive Compliance: EU Directive 2003/11/EC (BFR)

EU CE Mark: Yes

EU RoHS Compliance Date (yyyy-mm-dd): 2005-04-01

CA Prop 65 (CJ for Wire & Cable): Yes

MII Order #39 (China RoHS): Yes

Flammability, LS0H, Toxicity Testing

C(UL) Flammability: FT4

UL Flammability: UL1666 Vertical Shaft

UL voltage rating: 300 V RMS

Plenum/Non-Plenum

Plenum (Y/N): N

Plenum Number: 6300UE

Part Number

Variants

Item # Color Footnote

5300UE 0101000 Black C

5300UE 010U1000 Black

5300UE 010Z1000 Black

5300UE 010Z1000 Black

5300UE 0061000 Blue, Light

5300UE 0061000 Blue, Light

5300UE 001U1000 Brown

5300UE 001Z1000 Brown

5300UE 001Z1000 Brown

5300UE.00152 Chrome

5300UE.00305 Chrome

5300UE 0081000 Gray C

5300UE 008500 Gray

5300UE 008C500 Gray

5300UE 008U1000 Gray

5300UE 008U500 Gray

5300UE 0083400 Gray

5300UE 008Z1000 Gray

5300UE 008Z1000 Gray

5300UE 005Z1000 Green

5300UE 005Z1000 Green

5300UE 0051000 Green, Dark

5300UE 0051000 Green, Dark

5300UE 0021000 Red

5300UE 0021000 Red

5300UE 002Z1000 Red

5300UE 002Z1000 Red

5300UE 0071000 Violet

5300UE 0071000 Violet

5300UE 007Z1000 Violet

5300UE 007Z1000 Violet

5300UE 0091000 White C

5300UE 009U1000 White

5300UE 009Z1000 White

5300UE 009Z1000 White

5300UE 0041000 Yellow

5300UE 0041000 Yellow

Footnote: C - CRATE REEL PUT-UP.

© 2019 Belden, Inc

All Rights Reserved.

Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability.

Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.

All sales of Belden products are subject to Belden's standard terms and conditions of sale.

Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.

Davis, CA 95616 3D Technology Job# 3D-18-151

Northern California Youth Regional

Treatment Center

Public Address System

SECTION: 275116-1

Tab 3

Floor Plan Layout

SECTION C

VOICE OVER IP TELEPHONE SYSTEM

IHS, SACRED OAKS HEALING CENTER, DAVIS, CA

PERFORMANCE WORK STATEMENT

1. GENERAL: This is a non-personnel services contract to provide and setup a

Cisco voice over IP (VoIP) telephone system. The Government shall not exercise any supervision or control over the contract service providers performing the services herein. Such contract service providers shall be accountable solely to the Contractor who, in turn is responsible to the Government. It is the Government’s intention to award a firm-fixed price contract with a base and two option periods.

1.1. Description of Services/Introduction: The contractor shall provide all personnel, equipment, supplies, facilities, transportation, tools, materials, supervision, and other items and non-personal services necessary to purchase, install, and setup a Cisco VoIP telephone system as defined in this Performance Work Statement (PWS) except for those items specified as government furnished property and services. The contractor shall perform to the standards in this contract.

1.2. Background: A new Cisco VoIP on-premise, telephone, voicemail, and paging system is required to perform daily administrative tasks at a multi-function, twenty-four (24) hour inpatient care facility. The Indian Health Service (IHS) Sacred Oaks Healing Center (SOHC) is a brand new Youth Regional Treatment Center (YRTC) facility, construction having just completed in February 2020 and consists of five buildings that are approximately 35,000 square feet in total. The five buildings provide for a residential unit, administration offices, classrooms, kitchen & dining, recreation and therapy, cultural building, and utilities building.

A new Cisco VoIP on-premise, telephone, voicemail, and paging system is required to perform daily administrative tasks at a multi-function, twenty-four (24) hour inpatient care facility. The Indian Health Service (IHS) Sacred Oaks Healing Center (SOHC) is a brand new Youth Regional Treatment Center (YRTC) facility, construction having just completed in February 2020 and consists of five buildings that are approximately 35,000 square feet in total. The five buildings provide for a residential unit, administration offices, classrooms, kitchen & dining, recreation and therapy, cultural building, and utilities building.

1.3. Objectives: (1) Purchase Cisco VoIP telephone system equipment; (2)

Install and setup Cisco VoIP equipment; 3. Connect telephone system to existing overhead PA system for paging; 4. Train on-site system administrator how to manage moves, adds, changes, and deletions (MACD) on phone system.

1.4. Cutover Schedule. The contractor shall provide a cutover schedule within 10 calendar days after award to ensure project tasks are performed in accordance with this PWS. The contractor shall develop and implement procedures to identify, prevent, and ensure non-recurrence of defective services.

1.5. Contractor Staff: The contractor is responsible for ensuring all employees are familiar with, capable of and certified at installing and setting up Cisco voice over IP telephone system equipment, devices, and software.

1.6. Contractor Staff Oversight. The contractor shall provide an adequate number of fully qualified personnel to perform the work specified herein. If the Contractor chooses to accomplish the work by subcontract, he/she shall still be able to provide the required service and supply within the established period of performance. It is the Contractor’s responsibility to ensure that personnel fulfill the requirements of the contract. All personnel employed under this contract shall be legal residents of the United States.

2. PERIOD OF PERFORMANCE: The period of performance shall be, from date of award, 30 calendar days for the purchase, installation and setup;

and one year after telephone system installation and setup is complete for warranty support, with two (2) optional years for support. The Period of Performance reads as follows:

2.1. Base Period.

2.1.1. Work Activities. The Contract has 30-calendar days from date award to complete all work activities.

2.1.1.1. Warranty Period (Base Period). From date of award to 365 calendar days later.

2.2. Option Year 1. Shall commence from completion of the base period and end

365 calendar days later.

2.2.1.1. Warranty Period (Option Period 1). Shall commence from completion of the base period and end 365 calendar days later.

2.2.2. Option Year 2. Shall commence from completion of Option Period

One (1) and end 365-calendar days later.

2.2.2.1. Warranty Period (Option Period 2). Shall commence from completion of the base period and end 365 calendar days later.

3. QUALITY ASSURANCE/CONTROL

3.1. Quality Control: The Contractor shall be responsible for establishing and maintaining quality control to ensure satisfactory performance. The Contractor shall meet with the Government to become familiar with the work requirement(s) at no additional cost to the Government. Failure of the Contractor to become familiar may result in damage. The Contractor may be held liable for repair or replacement of such damaged facilities. The Government shall monitor all work to assure compliance with the Performance Work Statement, Pricing Schedule, Drawings, Clauses and Provisions.

3.2. Periodic Progress Meetings & Post-Award Conference(s): The business owner or CEO shall be prepared to meet weekly, or as required, at any periodic progress or post award meetings, within 24-hour written notice by the Contracting Officer. These meetings will serve as the forum for the Contracting Officer to apprise the contractor of how the government views the contractor's performance and the contractor will apprise the Government of problems, if any, being experienced. Appropriate action shall be taken to resolve outstanding issues. These meetings shall be at no additional cost to the government.

3.3. Quality Assurance: The Government shall monitor the Contractor’s performance for conformance with the Performance Work Statement, Pricing Schedule, Drawings, Clauses and Provisions.

4. PLACE OF PERFORMANCE

4.1. Place of Performance: The work to be performed under this contract will be performed at Indian Health Service Sacred Oaks Healing Center, 33100 County Road 31, Davis, CA, 95616

4.2. Recognized Holidays: The contractor is not required to perform services on federal holidays.

New Year’s Day Labor Day

Martin Luther King Jr.’s Birthday Columbus Day President’s Day Veteran’s Day Memorial Day Thanksgiving Day Independence Day Christmas Day

4.3. Hours of Operation: The contractor is responsible for conducting business, between the hours of 8:00 AM – 4:30 PM, Monday thru Friday except Federal holidays or when the Government facility is closed due to local or national emergencies or similar Government directed facility closings. The Contractor shall maintain an adequate workforce for the uninterrupted performance of all tasks defined within this PWS when the Government facility is not closed for the above reasons.

5. SECURITY REQUIREMENTS

5.1. Physical Security: The contractor shall be responsible for safeguarding all government equipment, information and property provided for contractor use. At the close of each work period, government facilities, equipment, and materials shall be secured.

6. CONTRACTOR PERSONNEL

6.1. Conduct: The Contractor shall conform and require Contractor employees to conform to similar standards of conduct as Government personnel.

Personal conditions such as being under the influence of intoxicating beverages, drugs, etc., which may interfere with the performance of the contract services or affect the safety of the employee or others shall not be permitted. Misconduct of the kind set forth in this paragraph shall cause the Contractor to take disciplinary action against Contractor employees, which may result in the immediate removal of employee from Government property and removal from continued work under the contract. When it is necessary to remove Contractor personnel the Contractor shall immediately provide a qualified replacement to carry out the services performed.

6.2. Identification

6.2.1. All contractor personnel are required to carry a current driver’s license or photo company identification card. Driver’s license and/or company identification card shall be required to be shown and photo copied prior to gaining access. Contractor shall wear shirts or hats with their company identification embroidered on them to identify to the public that they are Contractors working for the Government.

6.2.2. All vehicles used by the Contractor shall have signs, magnetic or permanently affixed indicating the name of the company.

6.2.3. Supervision: The Contractor shall ensure that an English speaking supervisor is present at all times while work is in progress.

7. AUTHORITIES & POINTS OF CONTACT

7.1. Authorities/Technical Direction: The Contractor shall take no direction from any Government employee or any other person other than the Government Contracting Officer that changes the terms and conditions of this contract action, the scope, or any change that impacts the cost, price or schedule. Changes authorized by the Contracting Officer will be in the form of a written, official, signed modification to the contract action received by the Contractor before the Contractor will act upon those changes.

The Contractor will comply with the Changes clause of this contract when the contractor believes direction has been given from persons other than the Government Contracting Officer that equate to a change by notifying the Contractor Officer as directed by the clause. Any direction given by any Government employee or any other person outside their authority must be reported to the Contracting Officer.

7.2. Contracting Officer. The Contracting Officer for this requirement is Rachel

Rosas, by telephone at 916.930.3981 x318, or by email at Rachel.Rosas@IHS.gov.

7.3. Contracting Officer’s Representative (COR). The COR at this time is Kelly Stephenson, by telephone at 916.930.3981 x330, or by email at Kelly.Stephenson@IHS.gov.

7.3.1. Contracting Officer Representative (COR):

7.3.2. The (COR) will be identified by a letter of designation issued to the

COR, and a copy of which is sent to the Contractor, states the responsibilities and limitations of the COR, especially with regard to changes in cost or price, estimates or changes in delivery dates. The COR is not authorized to change any of the terms and conditions of the resulting order.

mailto:Rachel.Rosas@IHS.gov

7.3.3. Contracting Officer Representatives (CORs) are limited to the authorities stated in the COR appointment letters. If a COR is appointed under this contract, they will be appointed by written letter from the Contracting Officer to the Contractor and COR specific to this contract only.

The COR monitors all technical aspects of the contract and assists in contract administration. The COR is authorized to perform the following functions:

7.3.3.1. Assure that the Contractor performs the technical requirements of the contract

7.3.3.2. Perform inspections necessary in connection with contract performance

7.3.3.3. Maintain written and oral communications with the Contractor concerning technical aspects of the contract

7.3.3.4. Issue written interpretations of technical requirements, including Government drawings, designs, specifications

7.3.3.5. Monitor Contractor's performance and notifies both the

Contracting Officer and Contractor of any deficiencies

8. TRAVEL COSTS. Costs for transportation, lodging, meals, and incidental expenses incurred by contractor personnel on official company business are allowable subject to FAR 31.205-46 Travel Costs, General Services Agency, Joint Travel Regulations; and Indian Health Service Manual Part 5- Management Services, Chapter 8 -Travel. Costs for lodging, meals, and incidental expenses may be based on per diem, actual expenses, or a combination thereof, provided the method used results in a reasonable charge.

For more information on allowable costs see:

http://www.gsa.gov/portal/ext/public/site/FTR/file/Chapter301p010.html/catego ry/21868/#wp1089090. All requests for reimbursement shall be audited prior to disbursement of payments.

8.1. Allowable Costs. The Contractor may only invoice for those expenses actually incurred and shall provide copies of all original travel receipts with invoice(s) for reimbursement. All costs shall be in accordance with GSA published per diem rates at: http://www.gsa.gov/portal/content/104877.

Those costs that exceed the allowable rate shall not be reimbursed. At a minimum, all invoices requesting travel reimbursement shall include receipts for:

http://www.gsa.gov/portal/ext/public/site/FTR/file/Chapter301p010.html/category/21868/#wp1089090 http://www.gsa.gov/portal/ext/public/site/FTR/file/Chapter301p010.html/category/21868/#wp1089090 http://www.gsa.gov/portal/content/104877

8.1.1. Lodging, shall be paid in accordance with GSA rates

(http://www.gsa.gov/portal/content/104877)

8.1.2. Common Carrier;

8.1.3. Telephone Calls to a Residence;

8.1.4. Registration Fee; and any other expense(s) in excess of $50.00.

8.2. Governing Regulations

8.2.1. FAR 31.205-46--Travel Costs

(http://www.farmaster.com/farmaster/data/idx/FAR84/3102050046.htm

8.2.2. General Services Agency, Joint Travel regulations

(http://www.gsa.gov/portal/content/104790)

8.2.3. Indian Health Service Manual Part 5-Management Services, Chapter 8

-Travel (https://www.ihs.gov/IHM/index.cfm?module=dsp_ihm_pc_p5c8#5- 8.13Q)

9. GOVERNMENT FURNISHED PROPERTY, EQUIPMENT, AND

SERVICES. This section identifies those items such as property, information and/or services that will be provided for the contractor’s use (without cost to the contractor) to allow them to provide the required services, such as materials, facilities, training, etc.

9.1. Services: The Government will provide:

9.1.1. SIP service, referred to as IP Flex by the local exchange carrier, AT&T, with 100 DIDs.

9.1.2. Network configuration of router and switches in coordination with contractor’s guidance during the setup and configuration of phone system.

9.2. Facilities: The Government will provide ample work space for the preparation and setup of telephone system equipment.

http://www.gsa.gov/portal/content/104877 http://www.farmaster.com/farmaster/data/idx/FAR84/3102050046.htm http://www.farmaster.com/farmaster/data/idx/FAR84/3102050046.htm http://www.gsa.gov/portal/content/104790 https://www.ihs.gov/IHM/index.cfm?module=dsp_ihm_pc_p5c8#5-8.13Q https://www.ihs.gov/IHM/index.cfm?module=dsp_ihm_pc_p5c8#5-8.13Q

9.3. Equipment: The Government will provide: (For a complete list see

Attachment 4 – Network and telecom equipment, Build of Materials – SacredOaks-BOM1&2.xlsx)

9.3.1. Cisco ISR 4331 UC Bundle, PVDM4-32, UC License router

(ISR4331-V/K9)

9.3.2. Three (3) Cisco 9410 Catalyst switches (C9410R-96U-BNDL-A)

9.3.2.1. Each Catalyst switch has qty. x2 - 48-Port UPOE 10/100/1000 (RJ-45) blades, 6 total

9.3.3. Forty-three (43) Cisco UC Phones 7821 (handsets)

9.3.4. Overhead speakers

9.3.5. Overhead speaker system

9.3.6. Network cabling management racks

9.3.7. Finished CAT 6 cabling throughout campus buildings

9.3.8. Fiber optic between the three (3) main buildings, connected to

Catalyst switches above

10. CONTRACTOR FURNISHED ITEMS, SERVICES & RESPONSIBILITIES.

Materials and equipment the contractor must provide.

10.1. General: The Contractor shall furnish all supplies, equipment, facilities and services required to perform work under this contract that are not listed under Section 3 of this PWS.

10.2. Equipment: The contractor shall provide a Cisco VoIP, on-premise telephone system with, auto-attendant, voicemail, over-the-phone paging and overhead PA system paging, and secure Fax over IP solution.

10.2.1. The contractor will provide thirty (30) Cisco 7800 series telephone handsets. A total of seventy (70) handsets will be connected simultaneously to the phone system. See Part 3.3.3 above.

10.2.2. Phone system features must include, but is not limited to:

10.2.2.1. The proposed solution must be an on-premise system, not cloud based

10.2.2.2. Server and software to house and manage Cisco 7800 and 8800 series telephone handsets and devices

10.2.2.3. Automated attendant

10.2.2.4. Voicemail

10.2.2.5. Conference calling

10.2.2.6. Multiple line support

10.2.2.7. Three- or four- digit dialing internally, between extensions

10.2.2.8. Two (2) handsets for receptionists will require add-on module to display 80 extension numbers. Receptionists receiving inbound calls will use these modules to transfer calls to other extensions in the building

10.2.2.9. Users will have ability to set call forwarding, both physically at their phone and remotely (ex. calling in to their extension or voice mailbox to set call forwarding)

10.2.2.10.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .