These are engineering design drawings for a ground bonding winch motor project at Marine Corps Air Station Cherry Point in North Carolina. The project involves electrical and concrete work for Building 3957, specifically focusing on grounding wire installation and connection. The drawings (sheets G-001, E-101, and CU01) detail the scope of work, including cutting a 1' x 1' x 6" section in existing concrete to reconnect and repair the equipotential bonding ground wire, installing a new ground wire in 1" PVC conduit along the platform structure, and ensuring proper grounding connections meet NEC requirements. The project is part of Work Order 7500764, with a final design date of 07.02.2025, and is restricted to M&R MACC (Maintenance and Repair Multiple Award Construction Contract) contractors.

View the file

Other files

File Type Posted
Amendment 0002 7500764.pdf PDF
Amendment 0001 7500764.pdf PDF
7500764 STREAMLINE MACC.pdf PDF
7500764 RFP.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D

C

B

A i

-l"0

CHERRY POINT AIR STATION MAP

NOT TO SCALE

I

I I C I

11. l_l _ ] � - F .

-=��.2"

1;_- �J

• I

I

VICINITY MAP ./T

-N-OT-TO_S_C_A-LE

AREA OF WORK

BUILDINGS 3957

,_1

NAVFAC

NO.

12913317 12913318 12913319

GROUND BONDING WINCH MOTOR,

B3957 BUMEDS

MARINE CORPS AIR STATION

CHERRY POINT, NORTH CAROLINA

PW WO.# 7500764

INDEX OF DRAWINGS

SHEET

NO.

G-001 E-101

CU01

TITLE

TITLE SHEET

NEW WORK ELECTRICAL B3957

CONCRETE DETAIL

DESIGNED & ENGINEERED BY,

FACILITIES ENGINEERING

FINAL

07.02.2025

APPROVED

ACTM1Y - SATISFACTORY TO

DATE

APPROVED

FOR EFD FOR COMMANDER NAVFAC

DATE

A/E EFD

CRL __ DESIGN

-- DRAWN CRL

-- REVIEW RCM

QC

SEAi.

__ CHIEF ARCH./ ENGR.

PROJECT """AGER CRL

FIRE PROTECTION

BRANCH """AGER LPF

DESIGN DIRECTOR LPF

z

CJ (.)

C!) • z z ii': -t::J I;,:: z C!) -

� 0 V, D.

!!/ >� a:

u a:

i1: w _J ::c:

t (.)

z -a:

:ii:

en

D.

� a:

zQ w (.)

�w"-- z o_ >- a:

z <C

!,;!:iii:

w

CODE ID. NO. BOOQ 1 IZE D

SCALE, AS NOTED

FED NO.

STA. PROJ. NO. 75007654

SPEC. NO.

CONSTR. CONTR. NO.

NAVFAC DRAWING NO.

12913317

SHEET 1 OF 3

G-001

D�M �SION; 07 AUG 2018

D

C

B

A w

(/'1

C • w

LL

(/'1

=c

1 2

D

C

ID ID ID ID ID

EXISTING WINCH MOTOR

1 2

INSTALLATION

GENERAL NOTES:

1. CONDUIT SHALL BE PROVIDED AND INSTALLED NOT TO INHIBIT AND/OR

OBSTRUCT THE ACCESS INTO CEILINGS AND TO SERVICE, OR REPAIR

2. CONTRACTOR SHALL SURVEY AND LOCATE ALL UNDERGROUND UTILITIES

WITHIN THE WORK AREA

3. MEET REQUIREMENTS FOR GROUND WIRE IN NEC 680.26A AND NEC

680.26B

4. PRIOR TO WELDING, CONFIRM THAT THE BONDING GRID OR COPPER

WIRE IS CONDUCTIVE AND ELECTRICALLY CONTINUOUS WITH A

RESISTANCE OF LESS THAN 100 MILLI OHMS.

5. TEST GROUNDING SYSTEM TO ENSURE CONTINUITY, AND THAT

RESISTANCE TO GROUND IS NOT EXCESSIVE. TEST EACH GROUND ROD

FOR RESISTANCE TO GROUND BEFORE MAKING CONNECTIONS TO ROD;

TIE GROUNDING SYSTEM TOGETHER AND TEST FOR RESISTANCE TO

GROUND. MAKE RESISTANCE MEASUREMENTS IN DRY WEATHER, NOT

EARLIER THAN 48 HOURS AFTER RAINFALL. SUBMIT WRITTEN RESULTS

OF EACH TEST TO CONTRACTING OFFICER, AND INDICATE LOCATION OF

ROADS AS WELL AS RESISTANCE AND SOIL CONDITIONS AT TIME

MEASUREMENTS WERE MADE.

NEW WORK NOTES: (THIS SHEET ONLY)

OJ CUT 1' X 1' AND 6" DEEP SECTION IN EXISTING CONCRETE UNDERNEATH

HOIST PLATFORM SEE ATTACHED PICTURES AND CONCRETE DETAIL DWG

CU01 TO LOCATE WHERE EQUIPOTENTIAL BONDING GROUND WIRE OF THE

POOL HAD BEEN CUT FROM THE EXISTING BONDING GRID.

[TI PROVIDE EXOTHERMIC WELD ON THE EXISTING SIZE 8 THWN

GROUND WIRE TO RUN GROUND WIRE IN 1" SCH 40 PVC ALONG THE

PLATFORM STRUCTURE TO WINCH MOTOR LUGNUT TO BE TIED IN.

LEGEND

I HOIST PLATFORM 9HI

AREA OF WORI(

KEY PLAN

LOCATION OF EXISTING GROUND WIRE

3 4

DESIGNED & ENGINEERED BY,

FACILITIES ENGINEERING

FINAL

07.02.2025

APPROVED

ACTM1Y - SATISFACTORY TO

DATE

APPROVED

FOR EFD FOR COMMANDER NAVFAC

DATE

SEAi.

A/E EFD

DESIGN CRL ---

CRL ___ DRAWN

--- REVIEW RCM

QC

___ CHIEF ARCH./ ENGR.

PROJECT """AGER CRL

FIRE PROTECTION

BRANCH """AGER -�LP�F _

DESIGN DIRECTOR LPF

z

CJ (.)

C!) • z z ii':

t::J ..,:

;,:: z C!) -

� 0 V, D..

� a:u a:

i1: w _J ::c:

t (.)

z -z

� rn a:

:ii:

rn

� a:

zo w (.)

>- w "-- z o_ a: z <C

!,;!:iii:

I,::

w u z en f-.'." Cl z oIW �o� 8§ Z=> w-cc G 3:

CJ I'--

z�

-CW)

Clcc z Q.....J ccO oO za..

=>CJ

oz a:-

CJ�

v� z L01-oc.o

� r---cc Vl8o

0 LOI-

31'--Q

CJ:::

� [1...

CODE ID. NO. BOOQ 1 IZE D

SCALE, AS NOTED

FED NO.

L.() m n m

_J u

Q:'.

w _J w

Q:'.

35:

35:

w

:z:

STA. PROJ. NO. 75007654

SPEC. NO.

CONSTR. CONTR. NO.

NAVFAC DRAWING NO.

12913318

' SHEET 2 OF 3

o :;· 10· 20· 30 ■---�------�"-lli*.1§���5-iiiiiiiii.:il· E 1 01 SCALE 1 /16"= 1 '-0"

D�M �SION; 07 AUG 2018

D

C w

LL

(/'1

=c

AutoCAD SHX Text

SECTION

AutoCAD SHX Text 1 "

AutoCAD SHX Text 1/2

AutoCAD SHX Text

CLR.

AutoCAD SHX Text

EL. (0'-0")

AutoCAD SHX Text

POOL

AutoCAD SHX Text #4@24

AutoCAD SHX Text 12"

AutoCAD SHX Text 1'-4"

AutoCAD SHX Text 3'-0"

AutoCAD SHX Text

CL OF OPENING TO CUT IN SLAB

AutoCAD SHX Text

TO INSTALL GROUND CONNECTION

AutoCAD SHX Text

12" X 12" X 6" DEEP

AutoCAD SHX Text

KEY NOTES

AutoCAD SHX Text

AutoCAD SHX Text

AFTER GROUNDING CONNECTION IS MADE, REPLACE DAMAGED VAPOR BARRIER UNDER SLAB.

AutoCAD SHX Text

AutoCAD SHX Text

CUT SLAB 12" X 12" X 6" DEEP TO MAKE GROUND CONNECTION.

AutoCAD SHX Text

AutoCAD SHX Text

REINFORCING STEEL CUT SHALL BE REPLACED WITH #4 AT 12" C/C SPLICED AS BELOW.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text DRILL " DIA. HOLES IN SLAB 6" DEEP, INSERT #4 DOWELS INTO CONCRETE WITH 6" PROJECTION58" DIA. HOLES IN SLAB 6" DEEP, INSERT #4 DOWELS INTO CONCRETE WITH 6" PROJECTION

AutoCAD SHX Text

FILL HOLE WITH EXPOXY GROUT, SPLICE #4 REBAR TO DOWELS.

AutoCAD SHX Text

AutoCAD SHX Text

POUR 4000 PSI CONCRETE INTO CUT OPENING.

AutoCAD SHX Text

MARINE CORPS AIR STATION, CHERRY POINT, N.C.

AutoCAD SHX Text

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND

AutoCAD SHX Text

SPEC. NO.

AutoCAD SHX Text

CONSTR. CONTR. NO.

AutoCAD SHX Text

SHEET OF

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

STA. PROJ. NO.

AutoCAD SHX Text

FED NO.

AutoCAD SHX Text

CODE ID. NO. 80091 SIZE B

AutoCAD SHX Text

SCALE: NOTED

AutoCAD SHX Text

CHIEF ARCH./ ENGR.

AutoCAD SHX Text

BRANCH MANAGER

AutoCAD SHX Text

DESIGN DIRECTOR

AutoCAD SHX Text A/E

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

PROJECT MANAGER

AutoCAD SHX Text

DATE

AutoCAD SHX Text

QC

AutoCAD SHX Text

DESIGN

AutoCAD SHX Text

REVIEW

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

EFD

AutoCAD SHX Text

DESIGNED & ENGINEERED BY:

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY - SATISFACTORY TO

AutoCAD SHX Text

FOR EFD FOR COMMANDER NAVFAC

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

SYM.

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

MCAS CHERRY POINT DM&EB

AutoCAD SHX Text

A/E'S USE THIS SPACE FOR YOUR ADDRESS INFO.

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

FB

AutoCAD SHX Text

FB

AutoCAD SHX Text

MS

AutoCAD SHX Text

7500764 GROUND BONDING WINCH MOTOR,

AutoCAD SHX Text

B3957, BUMEDS

AutoCAD SHX Text

CRL

AutoCAD SHX Text

CONCRETE DETAIL

AutoCAD SHX Text

CU01

AutoCAD SHX Text 7500764

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text 1'

AutoCAD SHX Text 2'

AutoCAD SHX Text 1" = 1'-0"

AutoCAD SHX Text 12913319

12913319.pdf
Sheets and Views
CU01
2025-07-28T14:19:09-0400
PERRY.HEATHER.MELYNN.1388599614

File details come from the government source that posted it. Updated .