7500764 DrawingsAsOne.pdf
PDF 2 MB Posted
- Attached to
- Ground Bond Winch Motor, B3957 BUMEDS
- Solicitation number
- N400857500764
About this file
These are engineering design drawings for a ground bonding winch motor project at Marine Corps Air Station Cherry Point in North Carolina. The project involves electrical and concrete work for Building 3957, specifically focusing on grounding wire installation and connection. The drawings (sheets G-001, E-101, and CU01) detail the scope of work, including cutting a 1' x 1' x 6" section in existing concrete to reconnect and repair the equipotential bonding ground wire, installing a new ground wire in 1" PVC conduit along the platform structure, and ensuring proper grounding connections meet NEC requirements. The project is part of Work Order 7500764, with a final design date of 07.02.2025, and is restricted to M&R MACC (Maintenance and Repair Multiple Award Construction Contract) contractors.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment 0002 7500764.pdf | ||
| Amendment 0001 7500764.pdf | ||
| 7500764 STREAMLINE MACC.pdf | ||
| 7500764 RFP.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D
C
B
A i
-l"0
CHERRY POINT AIR STATION MAP
NOT TO SCALE
I
I I C I
11. l_l _ ] � - F .
-=��.2"
1;_- �J
• I
I
VICINITY MAP ./T
-N-OT-TO_S_C_A-LE
AREA OF WORK
BUILDINGS 3957
,_1
NAVFAC
NO.
12913317 12913318 12913319
GROUND BONDING WINCH MOTOR,
B3957 BUMEDS
MARINE CORPS AIR STATION
CHERRY POINT, NORTH CAROLINA
PW WO.# 7500764
INDEX OF DRAWINGS
SHEET
NO.
G-001 E-101
CU01
TITLE
TITLE SHEET
NEW WORK ELECTRICAL B3957
CONCRETE DETAIL
DESIGNED & ENGINEERED BY,
FACILITIES ENGINEERING
FINAL
07.02.2025
APPROVED
ACTM1Y - SATISFACTORY TO
DATE
APPROVED
FOR EFD FOR COMMANDER NAVFAC
DATE
A/E EFD
CRL __ DESIGN
-- DRAWN CRL
-- REVIEW RCM
QC
SEAi.
__ CHIEF ARCH./ ENGR.
PROJECT """AGER CRL
FIRE PROTECTION
BRANCH """AGER LPF
DESIGN DIRECTOR LPF
z
CJ (.)
C!) • z z ii': -t::J I;,:: z C!) -
� 0 V, D.
!!/ >� a:
u a:
i1: w _J ::c:
t (.)
z -a:
:ii:
en
D.
� a:
zQ w (.)
�w"-- z o_ >- a:
z <C
!,;!:iii:
w
CODE ID. NO. BOOQ 1 IZE D
SCALE, AS NOTED
FED NO.
STA. PROJ. NO. 75007654
SPEC. NO.
CONSTR. CONTR. NO.
NAVFAC DRAWING NO.
12913317
SHEET 1 OF 3
G-001
D�M �SION; 07 AUG 2018
D
C
B
A w
(/'1
C • w
LL
(/'1
=c
1 2
D
C
ID ID ID ID ID
EXISTING WINCH MOTOR
1 2
INSTALLATION
GENERAL NOTES:
1. CONDUIT SHALL BE PROVIDED AND INSTALLED NOT TO INHIBIT AND/OR
OBSTRUCT THE ACCESS INTO CEILINGS AND TO SERVICE, OR REPAIR
2. CONTRACTOR SHALL SURVEY AND LOCATE ALL UNDERGROUND UTILITIES
WITHIN THE WORK AREA
3. MEET REQUIREMENTS FOR GROUND WIRE IN NEC 680.26A AND NEC
680.26B
4. PRIOR TO WELDING, CONFIRM THAT THE BONDING GRID OR COPPER
WIRE IS CONDUCTIVE AND ELECTRICALLY CONTINUOUS WITH A
RESISTANCE OF LESS THAN 100 MILLI OHMS.
5. TEST GROUNDING SYSTEM TO ENSURE CONTINUITY, AND THAT
RESISTANCE TO GROUND IS NOT EXCESSIVE. TEST EACH GROUND ROD
FOR RESISTANCE TO GROUND BEFORE MAKING CONNECTIONS TO ROD;
TIE GROUNDING SYSTEM TOGETHER AND TEST FOR RESISTANCE TO
GROUND. MAKE RESISTANCE MEASUREMENTS IN DRY WEATHER, NOT
EARLIER THAN 48 HOURS AFTER RAINFALL. SUBMIT WRITTEN RESULTS
OF EACH TEST TO CONTRACTING OFFICER, AND INDICATE LOCATION OF
ROADS AS WELL AS RESISTANCE AND SOIL CONDITIONS AT TIME
MEASUREMENTS WERE MADE.
NEW WORK NOTES: (THIS SHEET ONLY)
OJ CUT 1' X 1' AND 6" DEEP SECTION IN EXISTING CONCRETE UNDERNEATH
HOIST PLATFORM SEE ATTACHED PICTURES AND CONCRETE DETAIL DWG
CU01 TO LOCATE WHERE EQUIPOTENTIAL BONDING GROUND WIRE OF THE
POOL HAD BEEN CUT FROM THE EXISTING BONDING GRID.
[TI PROVIDE EXOTHERMIC WELD ON THE EXISTING SIZE 8 THWN
GROUND WIRE TO RUN GROUND WIRE IN 1" SCH 40 PVC ALONG THE
PLATFORM STRUCTURE TO WINCH MOTOR LUGNUT TO BE TIED IN.
LEGEND
I HOIST PLATFORM 9HI
AREA OF WORI(
KEY PLAN
LOCATION OF EXISTING GROUND WIRE
3 4
DESIGNED & ENGINEERED BY,
FACILITIES ENGINEERING
FINAL
07.02.2025
APPROVED
ACTM1Y - SATISFACTORY TO
DATE
APPROVED
FOR EFD FOR COMMANDER NAVFAC
DATE
SEAi.
A/E EFD
DESIGN CRL ---
CRL ___ DRAWN
--- REVIEW RCM
QC
___ CHIEF ARCH./ ENGR.
PROJECT """AGER CRL
FIRE PROTECTION
BRANCH """AGER -�LP�F _
DESIGN DIRECTOR LPF
z
CJ (.)
C!) • z z ii':
t::J ..,:
;,:: z C!) -
� 0 V, D..
� a:u a:
i1: w _J ::c:
t (.)
z -z
� rn a:
:ii:
rn
� a:
zo w (.)
>- w "-- z o_ a: z <C
!,;!:iii:
I,::
w u z en f-.'." Cl z oIW �o� 8§ Z=> w-cc G 3:
CJ I'--
z�
-CW)
Clcc z Q.....J ccO oO za..
=>CJ
oz a:-
CJ�
v� z L01-oc.o
� r---cc Vl8o
0 LOI-
31'--Q
CJ:::
� [1...
CODE ID. NO. BOOQ 1 IZE D
SCALE, AS NOTED
FED NO.
L.() m n m
_J u
Q:'.
w _J w
Q:'.
35:
35:
w
:z:
STA. PROJ. NO. 75007654
SPEC. NO.
CONSTR. CONTR. NO.
NAVFAC DRAWING NO.
12913318
' SHEET 2 OF 3
o :;· 10· 20· 30 ■---�------�"-lli*.1§���5-iiiiiiiii.:il· E 1 01 SCALE 1 /16"= 1 '-0"
D�M �SION; 07 AUG 2018
D
C w
LL
(/'1
=c
AutoCAD SHX Text
SECTION
AutoCAD SHX Text 1 "
AutoCAD SHX Text 1/2
AutoCAD SHX Text
CLR.
AutoCAD SHX Text
EL. (0'-0")
AutoCAD SHX Text
POOL
AutoCAD SHX Text #4@24
AutoCAD SHX Text 12"
AutoCAD SHX Text 1'-4"
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text
CL OF OPENING TO CUT IN SLAB
AutoCAD SHX Text
TO INSTALL GROUND CONNECTION
AutoCAD SHX Text
12" X 12" X 6" DEEP
AutoCAD SHX Text
KEY NOTES
AutoCAD SHX Text
AutoCAD SHX Text
AFTER GROUNDING CONNECTION IS MADE, REPLACE DAMAGED VAPOR BARRIER UNDER SLAB.
AutoCAD SHX Text
AutoCAD SHX Text
CUT SLAB 12" X 12" X 6" DEEP TO MAKE GROUND CONNECTION.
AutoCAD SHX Text
AutoCAD SHX Text
REINFORCING STEEL CUT SHALL BE REPLACED WITH #4 AT 12" C/C SPLICED AS BELOW.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text DRILL " DIA. HOLES IN SLAB 6" DEEP, INSERT #4 DOWELS INTO CONCRETE WITH 6" PROJECTION58" DIA. HOLES IN SLAB 6" DEEP, INSERT #4 DOWELS INTO CONCRETE WITH 6" PROJECTION
AutoCAD SHX Text
FILL HOLE WITH EXPOXY GROUT, SPLICE #4 REBAR TO DOWELS.
AutoCAD SHX Text
AutoCAD SHX Text
POUR 4000 PSI CONCRETE INTO CUT OPENING.
AutoCAD SHX Text
MARINE CORPS AIR STATION, CHERRY POINT, N.C.
AutoCAD SHX Text
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
AutoCAD SHX Text
SPEC. NO.
AutoCAD SHX Text
CONSTR. CONTR. NO.
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
NAVFAC DRAWING NO.
AutoCAD SHX Text
STA. PROJ. NO.
AutoCAD SHX Text
FED NO.
AutoCAD SHX Text
CODE ID. NO. 80091 SIZE B
AutoCAD SHX Text
SCALE: NOTED
AutoCAD SHX Text
CHIEF ARCH./ ENGR.
AutoCAD SHX Text
BRANCH MANAGER
AutoCAD SHX Text
DESIGN DIRECTOR
AutoCAD SHX Text A/E
AutoCAD SHX Text
FIRE PROTECTION
AutoCAD SHX Text
PROJECT MANAGER
AutoCAD SHX Text
DATE
AutoCAD SHX Text
QC
AutoCAD SHX Text
DESIGN
AutoCAD SHX Text
REVIEW
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
EFD
AutoCAD SHX Text
DESIGNED & ENGINEERED BY:
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY - SATISFACTORY TO
AutoCAD SHX Text
FOR EFD FOR COMMANDER NAVFAC
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
SYM.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPR
AutoCAD SHX Text
MCAS CHERRY POINT DM&EB
AutoCAD SHX Text
A/E'S USE THIS SPACE FOR YOUR ADDRESS INFO.
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FB
AutoCAD SHX Text
FB
AutoCAD SHX Text
MS
AutoCAD SHX Text
7500764 GROUND BONDING WINCH MOTOR,
AutoCAD SHX Text
B3957, BUMEDS
AutoCAD SHX Text
CRL
AutoCAD SHX Text
CONCRETE DETAIL
AutoCAD SHX Text
CU01
AutoCAD SHX Text 7500764
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 1'
AutoCAD SHX Text 2'
AutoCAD SHX Text 1" = 1'-0"
AutoCAD SHX Text 12913319
| 12913319.pdf |
| Sheets and Views |
| CU01 |
| 2025-07-28T14:19:09-0400 | |
| PERRY.HEATHER.MELYNN.1388599614 |
File details come from the government source that posted it. Updated .