7394140 DrawingsAsOne SIGNED.pdf

PDF 397 KB Posted

Attached to
ELECTRIC POWER FOR TEMPORARY MGCS, BUILDING 244
Solicitation number
N400857394140
Issued by

About this file

This document appears to be an electrical drawing related to a federal contract opportunity. The drawing provides details for a new electrical feeder and equipment to be installed in Building 244 at the Marine Corps Air Station in Cherry Point, North Carolina.

The key details include the installation of a new electrical feeder from panel M3 to a new electrical equipment rack that will power a Mobile Ground Control Station (MGCS) and an Environmental Control Unit (ECU). The drawing includes an electrical one-line diagram, equipment details, and panel schedules. The related federal contract opportunity is solicitation number N400857394140 for "ELECTRIC POWER FOR TEMPORARY MGCS, BUILDING 244", which is restricted to the Mechanical MACC contractors. The scope of work and any applicable drawings are provided in the attached documents.

View the file

Other files

File Type Posted
7394140 Streamlined MACC.pdf PDF
RFP 7394140.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

'F' 'D'

'M2'

'VAV-0'

'MT'

'VAV'

MCC#2

'LB'

'LA'

'M1'

480Y

18'-6"

'M3'

4#1/0, 1#6G, 2"RGS

MGCS

ECU

ECU

24' x 8'

'-7

HP

HP

32'-0"

SG#1A

PMT

PMT

208Y

SG#1

6" H

E Q

U

IP

P

AD

0' 1/16"=1'

60'

A

B

2 3

C

D

1 2 3

AS SHOWN

BUILDING 244

1 2 12892426

7394140

EL

EC

TR

IC

AL

P

LA

N

A N

D D

ET

AI

LS

RCM

RCM

RCM

N/A

NAH

LPF

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G C

O M

M

AN

D

M

AR

IN

E

C O

R

PS

A

IR

S

TA

TI

O

N , C

H

ER

R Y

PO

IN

T, N

.C

DRAWFORM REVISION JULY 2003

NAVFAC DRAWING NO.

SHEET OF

CONSTR. CONTR. NO.

CODE ID. NO. 80091 SIZE D

STA. PROJ. NO.

SCALE:

FED NO.

SPEC. NO.

A

DESIGN DIRECTOR

B

CHIEF ARCH./ ENGR.

PROJECT MANAGER

FIRE PROTECTION

BRANCH MANAGER

QC

DATE

A/E

DRAWN

REVIEW

DESIGN

EFD

FOR EFD FOR COMMANDER NAVFAC

ACTIVITY - SATISFACTORY TO

DATE

APPROVED

APPROVED

SEAL

C

A/E'S USE THIS SPACE FOR YOUR ADDRESS INFO.

FACILITIES ENGINEERING

DESIGNED & ENGINEERED BY:

SY

M

D

ES

C

R

IP

TI

O

N

D

D

AT

E

AP

PR

NORTH

B244 KEYPLAN

10' 20' 40'

GENERAL NOTES

KEYED NOTES #

1 CONNECT NEW FEEDER TO EXISTING

SPARE 3P150 CIRCUIT BREAKER.

2 INSTALL NEW FEEDER FROM M3 TO

ELECTRICAL RACK AT CEILING HEIGHT IN

ROOM 05, CORE DRILL THROUGH WALL,

EXTEND AT APPROX. SAME HEIGHT AS

EXISTING CONDUITS ALONG EXTERIOR

BRICK WALL AND DOWN TO NEW

ELECTRICAL RACK. SEAL WALL

PENETRATIONS WITH GROUT.

3 INSTALL NEW ELECTRICAL EQUIPMENT,

SEE DETAIL THIS SHEET.

ELECTRICAL PANEL

ELECTRICAL FEEDER

EQUIPMENT RACK, WALL MOUNTED

MOBILE GROUND CONTROL STATION

HEAT PUMP

ENVIRONMENTAL CONTROL UNIT

LEGEND

1 IINSTALL ALL ELECTRICAL PER NEC

2 MGCS MAX LOAD = 18KW

ECU MAX LOAD = 12KW

A B C

LOAD (A)

M3

LOAD SERVED LOAD SERVEDCKT.

NO.

CKT.

NO.

WIRE

SIZE

BKR.

TRIP A B C

PHASE LOAD (A)

A B C

WIRE

SIZE

BKR.

TRIP

800A MLO 208Y/120V, 3PHASE, 4WIRE, N1, 35KAIC

B244 ELECTRICAL PLAN

"M3" PANEL SCHEDULE

ELEC. EQUIPMENT DETAIL

0" 1/8"=1"

30"6" 12" 18" 24"

ONE-LINE DIAGRAM

MGCS

HP

ECU

5/6/2024

AutoCAD SHX Text

AutoCAD SHX Text

TR-2

AutoCAD SHX Text

AutoCAD SHX Text C-D

AutoCAD SHX Text C-F

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C-C

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

N3R 208Y/120V 3P100A FUSED SWITCH FUSE@100A

AutoCAD SHX Text

HBL 5100R9W

AutoCAD SHX Text

HBL 560R9W

AutoCAD SHX Text

N3R 208Y/120V 3P60A FUSED SWITCH FUSE@40A

AutoCAD SHX Text

HBL 560R9W

AutoCAD SHX Text

N3R 208Y/120V 3P60A FUSED SWITCH FUSE@40A

AutoCAD SHX Text

HBL 560R9W

AutoCAD SHX Text

N3R 208Y/120V 3P60A FUSED SWITCH FUSE@40A

AutoCAD SHX Text

HBL 5279C

AutoCAD SHX Text

N3R 120V 1P30A FUSED SWITCH FUSE@15A

AutoCAD SHX Text

8X8 N4SS WIREWAY

AutoCAD SHX Text

60" ABOVE PAVEMENT

AutoCAD SHX Text

ATTACH UNISTRUT TO EXISTING BRICK WALL, MOUNT ELEC. EQUIPMENT TO UNISTRUT

AutoCAD SHX Text

ATTACH UNISTRUT TO EXISTING BRICK WALL, MOUNT ELEC. EQUIPMENT TO UNISTRUT

AutoCAD SHX Text

MYERS HUB

AutoCAD SHX Text

MYERS HUB

AutoCAD SHX Text

MYERS HUB

AutoCAD SHX Text

MYERS HUB

AutoCAD SHX Text

MYERS HUB

AutoCAD SHX Text

MYERS HUB

AutoCAD SHX Text

MYERS HUB

AutoCAD SHX Text

MYERS HUB

AutoCAD SHX Text E-101

AutoCAD SHX Text

ELECTRIC POWER FOR TEMPORARY MGCS

AutoCAD SHX Text

BUILDING 244

AutoCAD SHX Text

GRAPHIC SCALES:

AutoCAD SHX Text

AutoCAD SHX Text 1/16"=1'

AutoCAD SHX Text

NONE

AutoCAD SHX Text 1/8"=1"

AutoCAD SHX Text 3P150

AutoCAD SHX Text

4#1/0, 1#6G, 2"RGS

AutoCAD SHX Text

(5)1PL1/0-5

AutoCAD SHX Text "M1"

AutoCAD SHX Text 3P60

AutoCAD SHX Text 3P60

AutoCAD SHX Text 3P60

AutoCAD SHX Text 3P100

AutoCAD SHX Text 560R9W

AutoCAD SHX Text 560R9W

AutoCAD SHX Text 560R9W

AutoCAD SHX Text 5100R9W

AutoCAD SHX Text 4#3, 1#8G

AutoCAD SHX Text 4#8, 1#10G

AutoCAD SHX Text 40J

AutoCAD SHX Text 40J

AutoCAD SHX Text 40J

AutoCAD SHX Text 100J

AutoCAD SHX Text

NONE

AutoCAD SHX Text 1P30

AutoCAD SHX Text 20J

AutoCAD SHX Text 5279C

AutoCAD SHX Text 3#12

AutoCAD SHX Text 4#8, 1#10G

AutoCAD SHX Text 4#8, 1#10G

AutoCAD SHX Text

WIREWAY

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING

AutoCAD SHX Text

AutoCAD SHX Text

SPARE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

VOV PANEL

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PANEL LB

AutoCAD SHX Text

AutoCAD SHX Text 1/0

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PANEL R

AutoCAD SHX Text

AutoCAD SHX Text

PANEL LA

AutoCAD SHX Text 3/0

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SPACE

AutoCAD SHX Text

SPACE

AutoCAD SHX Text

SPACE

AutoCAD SHX Text

RM 20 HOIST

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING

AutoCAD SHX Text 3/0

AutoCAD SHX Text 3/0

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1/0

AutoCAD SHX Text 1/0

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AIR COMPRESSOR

AutoCAD SHX Text

MGCS ELEC. RACK

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

Sheets and Views
12892426