This is a set of construction drawings for relocating smoke detectors in Buildings 4166 and 4167 at Marine Corps Air Station Cherry Point, North Carolina, under Public Works Work Order 7341320. The drawings include detailed floor plans for both three-story Bachelor Enlisted Quarters (BEQ) buildings, showing the locations where existing smoke detectors will be removed from bulkhead walls and reinstalled in the center of rooms.

The project involves providing all materials and labor necessary for modifying the automatic fire detection and alarm system, requiring new metal raceways and conduit for relocated devices. Key requirements include: protecting existing smoke detectors during removal and reinstallation, extending 3/4" EMT conduit to new locations, mounting devices on new junction boxes in room centers, and maintaining compliance with NFPA codes and UL listings. The drawings show floor-by-floor layouts with demolition notes and new work notes for each building, including first through third floors, with all junction boxes to be painted red and labeled "FIRE ALARM." The drawings are dated December 19, 2023 and marked as final.

View the file

Other files

File Type Posted
AMENDMENT 0001.pdf PDF
RFP 7341320.pdf PDF
7341320 SpecsAsOne SIGNED.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MAIN GATE

PASS & ID BUILDING

CHERRY POINT, N.C.

MARINE CORPS AIR STATION

DRAWING INDEX

RELOCATE BEQ SMOKE DETECTORS,

PW WO. 7341320

STATION BEQS, B4166 AND B4167

AREA OF WORK BUILDING

4166 AND 4167

AREA OF WORK

BUILDING 4166 AND 4167

BLDG 87

ROICC FEAD

FINAL

12.19.2023

1/29/2024

AutoCAD SHX Text

SLOCUM RD.

AutoCAD SHX Text

2ND AVE

AutoCAD SHX Text

E STREET

AutoCAD SHX Text

4TH AVE

AutoCAD SHX Text

3RD AVE

AutoCAD SHX Text

5TH AVE

AutoCAD SHX Text

1ST AVE

AutoCAD SHX Text

C STREET

AutoCAD SHX Text

CURTIS RD

AutoCAD SHX Text

BEACHY RD

AutoCAD SHX Text

LANGLEY RD

AutoCAD SHX Text

WRIGHT RD

AutoCAD SHX Text

CUNNINGHAM RD

AutoCAD SHX Text

ROOSEVELT BLVD.

AutoCAD SHX Text

A STREET

AutoCAD SHX Text

ACCESS RD

AutoCAD SHX Text

DUFFY RD

AutoCAD SHX Text

6TH AVE

AutoCAD SHX Text

F STREET

AutoCAD SHX Text

HWY 101

AutoCAD SHX Text

ROOSEVELT BLVD.

AutoCAD SHX Text

LOCATION MAP

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

MARINE CORPS AIR STATION, CHERRY POINT, N.C.

AutoCAD SHX Text

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND

AutoCAD SHX Text

DRAWFORM REVISION JULY 2003

AutoCAD SHX Text

AutoCAD SHX Text

SPEC. NO.

AutoCAD SHX Text

CONSTR. CONTR. NO.

AutoCAD SHX Text

SHEET OF

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

STA. PROJ. NO.

AutoCAD SHX Text

FED NO.

AutoCAD SHX Text

CODE ID. NO. 80091 SIZE D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text A

AutoCAD SHX Text

CHIEF ARCH./ ENGR.

AutoCAD SHX Text

BRANCH MANAGER

AutoCAD SHX Text

DESIGN DIRECTOR

AutoCAD SHX Text A/E

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

PROJECT MANAGER

AutoCAD SHX Text

DATE

AutoCAD SHX Text

QC

AutoCAD SHX Text

DESIGN

AutoCAD SHX Text

REVIEW

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

EFD

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text

DESIGNED & ENGINEERED BY:

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY - SATISFACTORY TO

AutoCAD SHX Text

FOR EFD FOR COMMANDER NAVFAC

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text C

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

SYM.

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

FACILITIES ENGINEERING

AutoCAD SHX Text

MECHANICAL DIVISION

AutoCAD SHX Text G-001

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 12891806

AutoCAD SHX Text 7341320

AutoCAD SHX Text

RELOCATE BEQ SMOKE DETECTORS

AutoCAD SHX Text

STATION BEQS, B4166 & B4167

AutoCAD SHX Text

TITLE SHEET

AutoCAD SHX Text

BDL

AutoCAD SHX Text

BDL

AutoCAD SHX Text

NAH

AutoCAD SHX Text

NAH

AutoCAD SHX Text

LPF

AutoCAD SHX Text

LOCATION PLAN

AutoCAD SHX Text

SHEET NO.

AutoCAD SHX Text G-001

AutoCAD SHX Text

FA-001

AutoCAD SHX Text

FA-101

AutoCAD SHX Text

FA-102

AutoCAD SHX Text

FA-103

AutoCAD SHX Text

FA-104

AutoCAD SHX Text

FA-105

AutoCAD SHX Text

FA-106

AutoCAD SHX Text 12891806

AutoCAD SHX Text

NAVFAC NO.

AutoCAD SHX Text 12891807

AutoCAD SHX Text 12891808

AutoCAD SHX Text 12891809

AutoCAD SHX Text 12891810

AutoCAD SHX Text 12891811

AutoCAD SHX Text 12891812

AutoCAD SHX Text 12891813

AutoCAD SHX Text

TITILE

AutoCAD SHX Text

TITLE SHEET

AutoCAD SHX Text

GENERAL NOTES, LEGENDS, AND ABBREVIATIONS

AutoCAD SHX Text

BUILDING 4166 FIRST FLOOR PLAN - CONSTRUCTION

AutoCAD SHX Text

BUILDING 4166 SECOND FLOOR PLAN - CONSTRUCTION

AutoCAD SHX Text

BUILDING 4166 THIRD FLOOR PLAN - CONSTRUCTION

AutoCAD SHX Text

BUILDING 4167 FIRST FLOOR PLAN - CONSTRUCTION

AutoCAD SHX Text

BUILDING 4167 SECOND FLOOR PLAN - CONSTRUCTION

AutoCAD SHX Text

BUILDING 4167 THIRD FLOOR PLAN - CONSTRUCTION

AutoCAD SHX Text

SHEET.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ROOSEVELT BLVD

FINAL

12.19.2023

GENERAL NOTES

1. CONTRACTOR MUST PROVIDE ALL MATERIALS AND LABOR NECESSARY FOR THE

INSTALLATION OF A NEW AUTOMATIC FIRE DETECTION AND ALARM SYSTEM PURSUANT TO

THESE DOCUMENTS. WORK MUST BE COMPLETED IN EVERY RESPECT RESULTING IN A

SYSTEM INSTALLED ENTIRELY IN ACCORDANCE WITH THE APPLICABLE CODES, STANDARDS,

MANUFACTURER'S RECOMMENDATIONS AND UNDERWRITERS LABORATORIES, INC. (UL)

LISTING.

2. THE CONTRACTOR MUST BE RESPONSIBLE FOR FIELD VERIFYING ALL EXISTING CONDITIONS

AND ANY CRITICAL DIMENSIONS ASSOCIATED WITH THE SCOPE OF WORK PRIOR TO

SUBMITTING THE CONSTRUCTION BID. THE CONTRACTOR MUST CONFIRM THAT ALL WORK

OUTLINED WITHIN THESE DOCUMENTS MAY BE ACCOMPLISHED AS SHOWN, AND MUST

NOTIFY THE ENGINEER OF ANY CONDITIONS ENCOUNTERED WHICH MAY AFFECT BUILDING

CODE COMPLIANCE.

3. ALL DEVICES, SYSTEMS, EQUIPMENT AND MATERIALS FURNISHED AND INSTALLED WILL BE

NEW AND LISTED BY UL. ALL EQUIPMENT MUST BE INSTALLED IN ACCORDANCE WITH THE

MANUFACTURES' RECOMMENDATIONS AND THE UL LISTED LIMITATIONS.

4. THE CONTRACTOR MUST BE RESPONSIBLE FOR COORDINATING ALL WORK. CONTRACTOR

MUST CONTACT/SCHEDULE/COORDINATE WITH MCAS PERSONNEL AS NECESSARY TO

COMPLETE THE PROJECT. OUTAGES WILL BE SCHEDULED AND COORDINATED WITH OWNER

THROUGH THE PROJECT MANAGER.

5. EXISTING FIRE PROTECTION/ALARM SYSTEMS MUST NOT BE TAKEN OUT OF SERVICE

WITHOUT PRIOR WRITTEN APPROVAL AND PROPER NOTIFICATION OF ALL ASSOCIATED

PARTIES.

6. ALL NEW AND RENOVATED WIRE AND CABLES MUST BE RAN IN NEW METAL RACEWAYS.

RACEWAYS MUST BE CONCEALED WHERE POSSIBLE.

7. EXCEPT AS OTHERWISE REQUIRED BY CODE, THE INSTALLATION OF THE FIRE ALARM

CIRCUITS MUST CONFORM TO THE REQUIREMENTS OF ARTICLE 760 AND RACEWAY

INSTALLATION TO THE APPLICABLE SECTIONS OF CHAPTER 3 OF NFPA 70, NATIONAL

ELECTRICAL CODE.

8. EXISTING CONDUIT MAY BE USED WHEREVER FEASIBLE AND COMPLIANT WITH THESE

DOCUMENTS. EXISTING WIRING MUST NOT BE REUSED.

9. ALL END-OF-LINE RESISTORS MUST BE MOUNTED ON TERMINAL BLOCKS.

10. ALL NEW AND REUSED JUNCTION BOX COVERS MUST BE PAINTED RED AND LABELED "FIRE

ALARM".

11. CONTRACTOR MUST PATCH AND PAINT ALL LOCATIONS WHERE WALLS, CEILINGS, OR OTHER

SURFACES ARE DISTURBED, ALTERED, OR MODIFIED.

12. ALL EXISTING WIRE, DEVICES AND EQUIPMENT THAT IS ABANDONED AS A RESULT OF THIS

PROJECT MUST BE REMOVED. DEMOLITION DRAWINGS ARE GENERAL IN NATURE.

CONTRACTOR MUST CONFIRM EXISTING DEVICES AND OTHER EQUIPMENT AND REMOVE ALL.

13. ALL SURFACE MOUNTED OR ACCESSIBLE EXISTING CONDUIT AND JUNCTION BOXES THAT

ARE ABANDONED AS A RESULT OF THIS PROJECT MUST BE REMOVED AND THE SURFACE

RETURNED TO ORIGINAL CONDITION.

14. CONTRACTOR MUST LEAVE ALL OTHER EXISTING FIRE ALARM DEVICES AND APPLIANCES AS

IS.

15. SHOP DRAWINGS MUST BE IN ACCORDANCE WITH THESE DOCUMENTS, NFPA 72, AND MUST

SHOW EVERY DEVICE ASSOCIATED WITH THE SYSTEM. AS BUILT DRAWINGS MUST BE

COMPLETE FOR THE ENTIRE BUILDING. DEVICES IDENTIFIED DURING INSTALLATION MUST BE

SHOWN.

16. SCOPE OF WORK IS TO RELOCATE EXISTING SMOKE DETECTORS FROM BULKHEAD WALL TO

CENTER OF ROOMS. THE CONTRACTOR MUST REMOVE ONLY EXISTING SMOKE DETECTORS

INDICATED ON DRAWINGS, PROTECT FROM DAMAGE, EXTEND CONDUIT, CONDUCTORS AND

REINSTALL SMOKE DETECTORS.

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

MARINE CORPS AIR STATION, CHERRY POINT, N.C.

AutoCAD SHX Text

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND

AutoCAD SHX Text

DRAWFORM REVISION JULY 2003

AutoCAD SHX Text

AutoCAD SHX Text

SPEC. NO.

AutoCAD SHX Text

CONSTR. CONTR. NO.

AutoCAD SHX Text

SHEET OF

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

STA. PROJ. NO.

AutoCAD SHX Text

FED NO.

AutoCAD SHX Text

CODE ID. NO. 80091 SIZE D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text A

AutoCAD SHX Text

CHIEF ARCH./ ENGR.

AutoCAD SHX Text

BRANCH MANAGER

AutoCAD SHX Text

DESIGN DIRECTOR

AutoCAD SHX Text A/E

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

PROJECT MANAGER

AutoCAD SHX Text

DATE

AutoCAD SHX Text

QC

AutoCAD SHX Text

DESIGN

AutoCAD SHX Text

REVIEW

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

EFD

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text

DESIGNED & ENGINEERED BY:

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY - SATISFACTORY TO

AutoCAD SHX Text

FOR EFD FOR COMMANDER NAVFAC

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text C

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

SYM.

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

FACILITIES ENGINEERING

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text

MECHANICAL DIVISION

AutoCAD SHX Text

FA-001

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 12891807

AutoCAD SHX Text 7341320

AutoCAD SHX Text

RELOCATE BEQ SMOKE DETECTORS

AutoCAD SHX Text

STATION BEQS, B4166 & B4167

AutoCAD SHX Text

GENERAL NOTES, LEGENDS AND ABBREVIATIONS

AutoCAD SHX Text

BDL

AutoCAD SHX Text

BDL

AutoCAD SHX Text

NAH

AutoCAD SHX Text

NAH

AutoCAD SHX Text

LPF

AutoCAD SHX Text

FIRE ALARM LEGEND

AutoCAD SHX Text

SYMBOL

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

MANUAL PULL STATION

AutoCAD SHX Text

NOTIFICATION DEVICE

AutoCAD SHX Text

BELL NOTIFICATION

AutoCAD SHX Text

SMOKE DETECTOR

AutoCAD SHX Text

MONITOR MODULE

AutoCAD SHX Text

DUCT DETECTOR

AutoCAD SHX Text

(NOTE: NOT ALL SYMBOLS ARE USED ON DRAWINGS)

AutoCAD SHX Text

PRESSURE SWITCH

AutoCAD SHX Text

FIRE ALARM CONTROL PANEL

AutoCAD SHX Text

HEAT DETECTOR

AutoCAD SHX Text H

AutoCAD SHX Text M

AutoCAD SHX Text

FACP

AutoCAD SHX Text

PS

AutoCAD SHX Text F

P

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ADA

AutoCAD SHX Text

ADA

AutoCAD SHX Text

ADA

AutoCAD SHX Text

ADA

AutoCAD SHX Text

ADA

AutoCAD SHX Text

ADA

AutoCAD SHX Text

FACP

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text 15cd

AutoCAD SHX Text 177cd

AutoCAD SHX Text 177cd

AutoCAD SHX Text 177cd

AutoCAD SHX Text 177cd

AutoCAD SHX Text 177cd

AutoCAD SHX Text 177cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 30cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 30cd

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

MARINE CORPS AIR STATION, CHERRY POINT, N.C.

AutoCAD SHX Text

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND

AutoCAD SHX Text

DRAWFORM REVISION JULY 2003

AutoCAD SHX Text

AutoCAD SHX Text

SPEC. NO.

AutoCAD SHX Text

CONSTR. CONTR. NO.

AutoCAD SHX Text

SHEET OF

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

STA. PROJ. NO.

AutoCAD SHX Text

FED NO.

AutoCAD SHX Text

CODE ID. NO. 80091 SIZE D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text A

AutoCAD SHX Text

CHIEF ARCH./ ENGR.

AutoCAD SHX Text

BRANCH MANAGER

AutoCAD SHX Text

DESIGN DIRECTOR

AutoCAD SHX Text A/E

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

PROJECT MANAGER

AutoCAD SHX Text

DATE

AutoCAD SHX Text

QC

AutoCAD SHX Text

DESIGN

AutoCAD SHX Text

REVIEW

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

EFD

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text

DESIGNED & ENGINEERED BY:

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY - SATISFACTORY TO

AutoCAD SHX Text

FOR EFD FOR COMMANDER NAVFAC

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text C

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

SYM.

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

FACILITIES ENGINEERING

AutoCAD SHX Text

MECHANICAL DIVISION

AutoCAD SHX Text

FA-101

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 12891808

AutoCAD SHX Text 7341320

AutoCAD SHX Text

RELOCATE BEQ SMOKE DETECTORS

AutoCAD SHX Text

STATION BEQS, B4166 & B4167

AutoCAD SHX Text

BUILDING 4166 FIRST FLOOR PLAN - CONSTRUCTION

AutoCAD SHX Text

BDL

AutoCAD SHX Text

BDL

AutoCAD SHX Text

NAH

AutoCAD SHX Text

NAH

AutoCAD SHX Text

LPF

AutoCAD SHX Text

MATCHLINE - CONTINUES BELOW LEFT

AutoCAD SHX Text

MATCHLINE - CONTINUES ABOVE RIGHT

AutoCAD SHX Text

DEMOLITION NOTES

AutoCAD SHX Text

BLDG 4166 KEY PLAN

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

GRAPHIC SCALE MUST BE USED.

AutoCAD SHX Text

NOTE: IF THIS DRAWING IS A REDUCTION,

AutoCAD SHX Text

GRAPHIC SCALE:

AutoCAD SHX Text 10'

AutoCAD SHX Text

AutoCAD SHX Text 5'

AutoCAD SHX Text 30'

AutoCAD SHX Text

SCALE: 1/8"=1'-0"

AutoCAD SHX Text 20'

AutoCAD SHX Text 15'

AutoCAD SHX Text 25'

AutoCAD SHX Text 35'

AutoCAD SHX Text

BUILDING 4166 FIRST FLOOR PLAN - CONSTRUCTION

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text REMOVE EXISTING SMOKE DETECTOR, PROTECT FROM DAMAGE, AND PREP FOR RE-INSTALLATION.

AutoCAD SHX Text

NEW WORK NOTES

PROVIDE JUNCTION BOX EXTENSION RING, AND COVER WHERE EXISTING SMOKE DETECTOR WAS LOCATED. EXTEND 3/4" EMT CONDUIT (SURFACE MOUNTED) AND CONDUCTORS TO NEW JUNCTION BOX FOR EXISTING SMOKE DETECTOR. EXISTING SMOKE DETECTOR SHALL BE MOUNTED ON NEW JUNCTION BOX CENTER OF ROOM.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text P

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text P

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 30cd

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text 110cd

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text 30cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 30cd

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text 110cd

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text 30cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

MARINE CORPS AIR STATION, CHERRY POINT, N.C.

AutoCAD SHX Text

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND

AutoCAD SHX Text

DRAWFORM REVISION JULY 2003

AutoCAD SHX Text

AutoCAD SHX Text

SPEC. NO.

AutoCAD SHX Text

CONSTR. CONTR. NO.

AutoCAD SHX Text

SHEET OF

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

STA. PROJ. NO.

AutoCAD SHX Text

FED NO.

AutoCAD SHX Text

CODE ID. NO. 80091 SIZE D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text A

AutoCAD SHX Text

CHIEF ARCH./ ENGR.

AutoCAD SHX Text

BRANCH MANAGER

AutoCAD SHX Text

DESIGN DIRECTOR

AutoCAD SHX Text A/E

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

PROJECT MANAGER

AutoCAD SHX Text

DATE

AutoCAD SHX Text

QC

AutoCAD SHX Text

DESIGN

AutoCAD SHX Text

REVIEW

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

EFD

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text

DESIGNED & ENGINEERED BY:

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY - SATISFACTORY TO

AutoCAD SHX Text

FOR EFD FOR COMMANDER NAVFAC

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text C

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

SYM.

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

FACILITIES ENGINEERING

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text

MECHANICAL DIVISION

AutoCAD SHX Text

FA-102

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 12891809

AutoCAD SHX Text 7341320

AutoCAD SHX Text

RELOCATE BEQ SMOKE DETECTORS

AutoCAD SHX Text

STATION BEQS, B4166 & B4167

AutoCAD SHX Text

BUILDING 4166 SECOND FLOOR PLAN - CONSTRUCTION

AutoCAD SHX Text

BDL

AutoCAD SHX Text

BDL

AutoCAD SHX Text

NAH

AutoCAD SHX Text

NAH

AutoCAD SHX Text

LPF

AutoCAD SHX Text

MATCHLINE - CONTINUES BELOW LEFT

AutoCAD SHX Text

MATCHLINE - CONTINUES ABOVE RIGHT

AutoCAD SHX Text

BLDG 4166 KEY PLAN

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

GRAPHIC SCALE MUST BE USED.

AutoCAD SHX Text

NOTE: IF THIS DRAWING IS A REDUCTION,

AutoCAD SHX Text

GRAPHIC SCALE:

AutoCAD SHX Text 10'

AutoCAD SHX Text

AutoCAD SHX Text 5'

AutoCAD SHX Text 30'

AutoCAD SHX Text

SCALE: 1/8"=1'-0"

AutoCAD SHX Text 20'

AutoCAD SHX Text 15'

AutoCAD SHX Text 25'

AutoCAD SHX Text 35'

AutoCAD SHX Text

BUILDING 4166 SECOND FLOOR PLAN - CONSTRUCTION

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text

DEMOLITION NOTES

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text REMOVE EXISTING SMOKE DETECTOR, PROTECT FROM DAMAGE, AND PREP FOR RE-INSTALLATION.

AutoCAD SHX Text

NEW WORK NOTES

PROVIDE JUNCTION BOX EXTENSION RING, AND COVER WHERE EXISTING SMOKE DETECTOR WAS LOCATED. EXTEND 3/4" EMT CONDUIT (SURFACE MOUNTED) AND CONDUCTORS TO NEW JUNCTION BOX FOR EXISTING SMOKE DETECTOR. EXISTING SMOKE DETECTOR SHALL BE MOUNTED ON NEW JUNCTION BOX CENTER OF ROOM.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text P

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text P

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 30cd

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text 110cd

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text 30cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

MARINE CORPS AIR STATION, CHERRY POINT, N.C.

AutoCAD SHX Text

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND

AutoCAD SHX Text

DRAWFORM REVISION JULY 2003

AutoCAD SHX Text

AutoCAD SHX Text

SPEC. NO.

AutoCAD SHX Text

CONSTR. CONTR. NO.

AutoCAD SHX Text

SHEET OF

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

STA. PROJ. NO.

AutoCAD SHX Text

FED NO.

AutoCAD SHX Text

CODE ID. NO. 80091 SIZE D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text A

AutoCAD SHX Text

CHIEF ARCH./ ENGR.

AutoCAD SHX Text

BRANCH MANAGER

AutoCAD SHX Text

DESIGN DIRECTOR

AutoCAD SHX Text A/E

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

PROJECT MANAGER

AutoCAD SHX Text

DATE

AutoCAD SHX Text

QC

AutoCAD SHX Text

DESIGN

AutoCAD SHX Text

REVIEW

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

EFD

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text

DESIGNED & ENGINEERED BY:

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY - SATISFACTORY TO

AutoCAD SHX Text

FOR EFD FOR COMMANDER NAVFAC

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text C

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

SYM.

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

FACILITIES ENGINEERING

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text

MECHANICAL DIVISION

AutoCAD SHX Text

FA-103

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 12891810

AutoCAD SHX Text 7341320

AutoCAD SHX Text

RELOCATE BEQ SMOKE DETECTORS

AutoCAD SHX Text

STATION BEQS, B4166 & B4167

AutoCAD SHX Text

BUILDING 4166 THIRD FLOOR PLAN - CONSTRUCTION

AutoCAD SHX Text

BDL

AutoCAD SHX Text

BDL

AutoCAD SHX Text

NAH

AutoCAD SHX Text

NAH

AutoCAD SHX Text

LPF

AutoCAD SHX Text

MATCHLINE - CONTINUES BELOW LEFT

AutoCAD SHX Text

MATCHLINE - CONTINUES ABOVE RIGHT

AutoCAD SHX Text

BLDG 4166 KEY PLAN

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

GRAPHIC SCALE MUST BE USED.

AutoCAD SHX Text

NOTE: IF THIS DRAWING IS A REDUCTION,

AutoCAD SHX Text

GRAPHIC SCALE:

AutoCAD SHX Text 10'

AutoCAD SHX Text

AutoCAD SHX Text 5'

AutoCAD SHX Text 30'

AutoCAD SHX Text

SCALE: 1/8"=1'-0"

AutoCAD SHX Text 20'

AutoCAD SHX Text 15'

AutoCAD SHX Text 25'

AutoCAD SHX Text 35'

AutoCAD SHX Text

BUILDING 4166 THIRD FLOOR PLAN - CONSTRUCTION

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text

DEMOLITION NOTES

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text REMOVE EXISTING SMOKE DETECTOR, PROTECT FROM DAMAGE, AND PREP FOR RE-INSTALLATION.

AutoCAD SHX Text

NEW WORK NOTES

PROVIDE JUNCTION BOX EXTENSION RING, AND COVER WHERE EXISTING SMOKE DETECTOR WAS LOCATED. EXTEND 3/4" EMT CONDUIT (SURFACE MOUNTED) AND CONDUCTORS TO NEW JUNCTION BOX FOR EXISTING SMOKE DETECTOR. EXISTING SMOKE DETECTOR SHALL BE MOUNTED ON NEW JUNCTION BOX CENTER OF ROOM.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ADA

AutoCAD SHX Text

ADA

AutoCAD SHX Text

ADA

AutoCAD SHX Text

ADA

AutoCAD SHX Text

ADA

AutoCAD SHX Text

ADA

AutoCAD SHX Text

FACP

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text 15cd

AutoCAD SHX Text 177cd

AutoCAD SHX Text 177cd

AutoCAD SHX Text 177cd

AutoCAD SHX Text 177cd

AutoCAD SHX Text 177cd

AutoCAD SHX Text 177cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 30cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 30cd

AutoCAD SHX Text P

AutoCAD SHX Text F

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

MARINE CORPS AIR STATION, CHERRY POINT, N.C.

AutoCAD SHX Text

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND

AutoCAD SHX Text

DRAWFORM REVISION JULY 2003

AutoCAD SHX Text

AutoCAD SHX Text

SPEC. NO.

AutoCAD SHX Text

CONSTR. CONTR. NO.

AutoCAD SHX Text

SHEET OF

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

STA. PROJ. NO.

AutoCAD SHX Text

FED NO.

AutoCAD SHX Text

CODE ID. NO. 80091 SIZE D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text A

AutoCAD SHX Text

CHIEF ARCH./ ENGR.

AutoCAD SHX Text

BRANCH MANAGER

AutoCAD SHX Text

DESIGN DIRECTOR

AutoCAD SHX Text A/E

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

PROJECT MANAGER

AutoCAD SHX Text

DATE

AutoCAD SHX Text

QC

AutoCAD SHX Text

DESIGN

AutoCAD SHX Text

REVIEW

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

EFD

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text

DESIGNED & ENGINEERED BY:

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY - SATISFACTORY TO

AutoCAD SHX Text

FOR EFD FOR COMMANDER NAVFAC

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text C

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

SYM.

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

FACILITIES ENGINEERING

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text

MECHANICAL DIVISION

AutoCAD SHX Text

FA-104

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 12891811

AutoCAD SHX Text 7341320

AutoCAD SHX Text

RELOCATE BEQ SMOKE DETECTORS

AutoCAD SHX Text

STATION BEQS, B4166 & B4167

AutoCAD SHX Text

BUILDING 4167 FIRST FLOOR PLAN - CONSTRUCTION

AutoCAD SHX Text

BDL

AutoCAD SHX Text

BDL

AutoCAD SHX Text

NAH

AutoCAD SHX Text

NAH

AutoCAD SHX Text

LPF

AutoCAD SHX Text

BLDG 4167 KEY PLAN

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

MATCHLINE - CONTINUES BELOW LEFT

AutoCAD SHX Text

MATCHLINE - CONTINUES ABOVE RIGHT

AutoCAD SHX Text

GRAPHIC SCALE MUST BE USED.

AutoCAD SHX Text

NOTE: IF THIS DRAWING IS A REDUCTION,

AutoCAD SHX Text

GRAPHIC SCALE:

AutoCAD SHX Text 10'

AutoCAD SHX Text

AutoCAD SHX Text 5'

AutoCAD SHX Text 30'

AutoCAD SHX Text

SCALE: 1/8"=1'-0"

AutoCAD SHX Text 20'

AutoCAD SHX Text 15'

AutoCAD SHX Text 25'

AutoCAD SHX Text 35'

AutoCAD SHX Text

BUILDING 4167 FIRST FLOOR PLAN - CONSTRUCTION

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text

DEMOLITION NOTES

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text REMOVE EXISTING SMOKE DETECTOR, PROTECT FROM DAMAGE, AND PREP FOR RE-INSTALLATION.

AutoCAD SHX Text

NEW WORK NOTES

PROVIDE JUNCTION BOX EXTENSION RING, AND COVER WHERE EXISTING SMOKE DETECTOR WAS LOCATED. EXTEND 3/4" EMT CONDUIT (SURFACE MOUNTED) AND CONDUCTORS TO NEW JUNCTION BOX FOR EXISTING SMOKE DETECTOR. EXISTING SMOKE DETECTOR SHALL BE MOUNTED ON NEW JUNCTION BOX CENTER OF ROOM.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 110cd

AutoCAD SHX Text P

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text P

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 110cd

AutoCAD SHX Text 75cd

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text 110cd

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

MARINE CORPS AIR STATION, CHERRY POINT, N.C.

AutoCAD SHX Text

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND

AutoCAD SHX Text

DRAWFORM REVISION JULY 2003

AutoCAD SHX Text

AutoCAD SHX Text

SPEC. NO.

AutoCAD SHX Text

CONSTR. CONTR. NO.

AutoCAD SHX Text

SHEET OF

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

STA. PROJ. NO.

AutoCAD SHX Text

FED NO.

AutoCAD SHX Text

CODE ID. NO. 80091 SIZE D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text A

AutoCAD SHX Text

CHIEF ARCH./ ENGR.

AutoCAD SHX Text

BRANCH MANAGER

AutoCAD SHX Text

DESIGN DIRECTOR

AutoCAD SHX Text A/E

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

PROJECT MANAGER

AutoCAD SHX Text

DATE

AutoCAD SHX Text

QC

AutoCAD SHX Text

DESIGN

AutoCAD SHX Text

REVIEW

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

EFD

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text

DESIGNED & ENGINEERED BY:

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY - SATISFACTORY TO

AutoCAD SHX Text

FOR EFD FOR COMMANDER NAVFAC

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text C

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

SYM.

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

FACILITIES ENGINEERING

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text

MECHANICAL DIVISION

AutoCAD SHX Text

FA-105

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 12891812

AutoCAD SHX Text 7341320

AutoCAD SHX Text

RELOCATE BEQ SMOKE DETECTORS

AutoCAD SHX Text

STATION BEQS, B4166 & B4167

AutoCAD SHX Text

BUILDING 4167 SECOND FLOOR PLAN - CONSTRUCTION

AutoCAD SHX Text

BDL

AutoCAD SHX Text

BDL

AutoCAD SHX Text

NAH

AutoCAD SHX Text

NAH

AutoCAD SHX Text

LPF

AutoCAD SHX Text

MATCHLINE - CONTINUES BELOW LEFT

AutoCAD SHX Text

MATCHLINE - CONTINUES ABOVE RIGHT

AutoCAD SHX Text

BLDG 4167 KEY PLAN

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

GRAPHIC SCALE MUST BE USED.

AutoCAD SHX Text

NOTE: IF THIS DRAWING IS A REDUCTION,

AutoCAD SHX Text

GRAPHIC SCALE:

AutoCAD SHX Text 10'

AutoCAD SHX Text

AutoCAD SHX Text 5'

AutoCAD SHX Text 30'

AutoCAD SHX Text

SCALE: 1/8"=1'-0"

AutoCAD SHX Text 20'

AutoCAD SHX Text 15'

AutoCAD SHX Text 25'

AutoCAD SHX Text 35'

AutoCAD SHX Text

BUILDING 4167 SECOND FLOOR PLAN - CONSTRUCTION

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text

DEMOLITION NOTES

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text REMOVE EXISTING SMOKE DETECTOR, PROTECT FROM DAMAGE, AND PREP FOR RE-INSTALLATION.

AutoCAD SHX Text

NEW WORK NOTES

PROVIDE JUNCTION BOX EXTENSION RING, AND COVER WHERE EXISTING SMOKE DETECTOR WAS LOCATED. EXTEND 3/4" EMT CONDUIT (SURFACE MOUNTED) AND CONDUCTORS TO NEW JUNCTION BOX FOR EXISTING SMOKE DETECTOR. EXISTING SMOKE DETECTOR SHALL BE MOUNTED ON NEW JUNCTION BOX CENTER OF ROOM.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 110cd

AutoCAD SHX Text P

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text P

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 110cd

AutoCAD SHX Text 75cd

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text P

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 110cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

MARINE CORPS AIR STATION, CHERRY POINT, N.C.

AutoCAD SHX Text

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND

AutoCAD SHX Text

DRAWFORM REVISION JULY 2003

AutoCAD SHX Text

AutoCAD SHX Text

SPEC. NO.

AutoCAD SHX Text

CONSTR. CONTR. NO.

AutoCAD SHX Text

SHEET OF

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

STA. PROJ. NO.

AutoCAD SHX Text

FED NO.

AutoCAD SHX Text

CODE ID. NO. 80091 SIZE D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text A

AutoCAD SHX Text

CHIEF ARCH./ ENGR.

AutoCAD SHX Text

BRANCH MANAGER

AutoCAD SHX Text

DESIGN DIRECTOR

AutoCAD SHX Text A/E

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

PROJECT MANAGER

AutoCAD SHX Text

DATE

AutoCAD SHX Text

QC

AutoCAD SHX Text

DESIGN

AutoCAD SHX Text

REVIEW

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

EFD

AutoCAD SHX Text B

AutoCAD SHX Text

AutoCAD SHX Text

DESIGNED & ENGINEERED BY:

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY - SATISFACTORY TO

AutoCAD SHX Text

FOR EFD FOR COMMANDER NAVFAC

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text C

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

SYM.

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

FACILITIES ENGINEERING

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text

MECHANICAL DIVISION

AutoCAD SHX Text

FA-106

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 12891813

AutoCAD SHX Text 7341320

AutoCAD SHX Text

RELOCATE BEQ SMOKE DETECTORS

AutoCAD SHX Text

STATION BEQS, B4166 & B4167

AutoCAD SHX Text

BUILDINDG 4167 THIRD FLOOR PLAN - CONSTRUCTON

AutoCAD SHX Text

BDL

AutoCAD SHX Text

BDL

AutoCAD SHX Text

NAH

AutoCAD SHX Text

NAH

AutoCAD SHX Text

LPF

AutoCAD SHX Text

MATCHLINE - CONTINUES BELOW LEFT

AutoCAD SHX Text

MATCHLINE - CONTINUES ABOVE RIGHT

AutoCAD SHX Text

BLDG 4167 KEY PLAN

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

GRAPHIC SCALE MUST BE USED.

AutoCAD SHX Text

NOTE: IF THIS DRAWING IS A REDUCTION,

AutoCAD SHX Text

GRAPHIC SCALE:

AutoCAD SHX Text 10'

AutoCAD SHX Text

AutoCAD SHX Text 5'

AutoCAD SHX Text 30'

AutoCAD SHX Text

SCALE: 1/8"=1'-0"

AutoCAD SHX Text 20'

AutoCAD SHX Text 15'

AutoCAD SHX Text 25'

AutoCAD SHX Text 35'

AutoCAD SHX Text

BUILDING 4167 THIRD FLOOR PLAN - CONSTRUCTION

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text

DEMOLITION NOTES

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text REMOVE EXISTING SMOKE DETECTOR, PROTECT FROM DAMAGE, AND PREP FOR RE-INSTALLATION.

AutoCAD SHX Text

NEW WORK NOTES

PROVIDE JUNCTION BOX EXTENSION RING, AND COVER WHERE EXISTING SMOKE DETECTOR WAS LOCATED. EXTEND 3/4" EMT CONDUIT (SURFACE MOUNTED) AND CONDUCTORS TO NEW JUNCTION BOX FOR EXISTING SMOKE DETECTOR. EXISTING SMOKE DETECTOR SHALL BE MOUNTED ON NEW JUNCTION BOX CENTER OF ROOM.

7341320 DrawingsAsOne
12891806
Sheets and Views
Layout1
12891807
Sheets and Views
Layout1
12891808
Sheets and Views
Layout1
12891809
Sheets and Views
Layout1
12891810
Sheets and Views
Layout1
12891811
Sheets and Views
Layout1
12891812
Sheets and Views
Layout1
12891813
Sheets and Views
Layout1
12891813
Sheets and Views
Layout1

File details come from the government source that posted it. Updated .