720001 Crestview Waterline- Final Plans_REV 1.pdf
PDF 12 MB Posted
- Attached to
- 720001 Crestview Waterline
- Solicitation number
- S-KS0043-00010270
- Issued by
- Marion County, Oregon
About this file
The document provided is the final plans for the 720001 Crestview Waterline project, a state and local contract opportunity in Oregon with an estimated value between $1.5M and $1.7M. The project involves the construction of a new waterline. No additional details on the project's timeline, response requirements, or awarded contractor are provided in the file.
The pricing terms, set asides, incumbent contractors, funding requirements, and other salient contract details are not included in this file. Additional documentation would be needed to summarize those aspects of the state and local contract opportunity.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CITY OF SALEM - DEPARTMENT OF PUBLIC WORKS
555 LIBERTY STREET SE - SALEM, OREGON 97301
VICINITY MAP
PN: 720001
CRESTVIEW WATERLINE PROJECT AREA
Call before you dig.
Know what's below.
ATTENTION:
UTILITY CONTACTS
SHEET OF
SHEET TITLE
HORIZ DATUM:
VERT DATUM:
HORIZ SCALE:
VERT SCALE:
DESIGN:
DRAWN:
CHECKED:
APPROVED:
NO. DATE BYDESCRIPTION
REVISIONS
SALEM PUBLIC WORKS DEPART
MENT
NOISIVIDGNIREE
N NIGE
CRESTVIEW
WATERLINE
SHEET PREPARED BY:
245 Commercial St. SE, Suite 210 Salem, Oregon 97301
(503) 364-2002
PN:720001
NGVD29(COS)
NAD83(2011)
OREGON
EXPIRES: 06-30-2026
100901PEREG
ISTERED PROFESSIONALENGINEER
JULY 11, 2023
PAMELA GREENE V ILLA RREA
L
BOICE ST S
RI
VE
R
RD
S
SCHURMAN DR S
C R
ES
TV
IE
W
D R
S
COBURN ST S
AL
VA
R
AD
O T
ER
R
S
BO
LT
O N
T
ER
R S
TITLE SHEET
G-01
MRN
PGV
AS SHOWN
AS SHOWN
PAO
1 28
PAO, JLR
GRAVEL PLAN
AC PAVEMENT-PLAN AGGREGATE MATERIAL
UTILITIES AND TOPOGRAPHIC FEATURES
TO BE BUILT EXISTING
W W W W W
STORM-(CB T1/T2/T3/T4) CO
WATER METERWATER VALVE
RIGHT OF WAY
POWER POLE & ANCHORMAILBOX
FIRE HYDRANT
SANITARY SEWER
STORM DRAIN
WATER
NATURAL GAS
COMMUNICATION
MATERIAL IDENTIFICATION
NATURAL GROUND SECTION
CURB &
<8''SS <8''SS
<10''SD <10''SD
<8''SS
<10''SD
OHP OHP OHP OHP OHP OHP OHP OHP
ELECTRICITY
UNDERGROUND
ELECTRICITY
OVERHEAD
T T T T T T T T T
FENCE O O O O O X X X X X
WITH DRIVEWAY
SIDEWALK
AC PAVEMENT
TYPICAL SECTION
CONCRETE
PLAN/TYPICAL SECTION
NG NG NG NG NG NG NG NG NG
ROW ROW ROW ROW ROW ROW ROW
PROPERTY LINE
EASEMENT LINE
TO BE BUILT / EXISTING
UGP UGP UGP UGP UGP UGP UGP UGP
WORK DONE BY CONTRACTOR WORK DONE BY CITY FORCES WORK DONE BY OTHERS
DECIDUOUS EVERGREEN
TELEPHONE PED GAS VALVE
IRRIGATION LIGHTING
CALLOUTS
SEWER-(CO/
INSPECTION PORT)
EP EP EP EP EP EP EP EP EPEDGE OF
PAVEMENT
CULVERT
GENERAL CONSTRUCTION NOTES
SHEET OF
SHEET TITLE
HORIZ DATUM:
VERT DATUM:
HORIZ SCALE:
VERT SCALE:
DESIGN:
DRAWN:
CHECKED:
APPROVED:
NO. DATE BYDESCRIPTION
REVISIONS
SALEM PUBLIC WORKS DEPART
MENT
NOISIVIDGNIREE
N NIGE
CRESTVIEW
WATERLINE
SHEET PREPARED BY:
245 Commercial St. SE, Suite 210 Salem, Oregon 97301
(503) 364-2002
PN:720001
NGVD29(COS)
NAD83(2011)
OREGON
EXPIRES: 06-30-2026
100901PEREG
ISTERED PROFESSIONALENGINEER
JULY 11, 2023
PAMELA GREENE V ILLA RREA
L
GENERAL
CONSTRUCTION
NOTES
G-02
MRN
PGV
AS SHOWN
AS SHOWN
PAO
1. ALL CONSTRUCTION SHALL BE TO CITY OF SALEM STANDARDS AND SPECIFICATIONS AND THE SPECIAL
PROVISIONS DEVELOPED FOR THIS PROJECT.
2. REFERENCE STANDARD CONSTRUCTION SPECIFICATIONS FOR REQUIREMENTS REGARDING PROTECTION OF
EXISTING FACILITIES AND TREES.
3. REFERENCE STANDARD CONSTRUCTION SPECIFICATIONS FOR REQUIREMENTS REGARDING OPERATION OF
EXISTING WATER VALVES.
4. REFERENCE STANDARD CONSTRUCTION SPECIFICATIONS FOR TRAFFIC PROTECTION AND CONTROL
REQUIREMENTS.
5. UTILITY COORDINATION:
A. THE LOCATION AND DESCRIPTION OF EXISTING UTILITIES SHOWN ARE COMPILED FROM AVAILABLE RECORDS AND/OR FIELD SURVEYS. THE CITY OR UTILITY COMPANIES DO NOT GUARANTEE THE ACCURACY NOR THE
COMPLETENESS OF SUCH RECORDS.
B. ATTENTION: OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED BY THE OREGON UTILITY NOTIFICATION CENTER. THOSE RULES ARE SET FORTH IN OAR 952-001-0010 THROUGH OAR 952-001-0090. YOU MAY OBTAIN COPIES OF THE RULES BY CALLING THE CENTER. (NOTE: THE TELEPHONE NUMBER FOR THE
OREGON UTILITY NOTIFICATION CENTER IS (503)-232-1987).
C. PROVISIONS SHALL BE MADE BY THE CONTRACTOR TO KEEP ALL EXISTING UTILITIES IN SERVICE AND
PROTECT THEM DURING CONSTRUCTION.
D. UTILITIES, OR INTERFERING PORTIONS OF UTILITIES, THAT ARE ABANDONED IN PLACE SHALL BE REMOVED BY THE CONTRACTOR TO THE EXTENT NECESSARY TO ACCOMPLISH THE WORK. THE CONTRACTOR SHALL
PLUG THE REMAINING EXPOSED ENDS OF ABANDONED UTILITIES.
6. REFERENCE STANDARD CONSTRUCTION SPECIFICATIONS FOR ANY ADDITIONAL UTILITY COORDINATION
REQUIREMENTS.
7. THE CONTRACTOR SHALL BE EXPECTED TO VISIT THE SITE AND MAKE THEIR OWN DETERMINATION OF
TOPOGRAPHIC FEATURES REQUIRING RESTORATION.
8. DO NOT REMOVE TREES EXCEPT AS APPROVED BY THE CITY. PROTECT ALL ROOTS TWO INCHES AND LARGER IN
DIAMETER. TRIM TREES, SHRUBS AND HEDGES ONLY AS DIRECTED BY THE CITY.
9. ALL CONSTRUCTION SHALL CONFORM TO OREGON D.E.Q. PERMIT No. 1200-CA, A COPY OF WHICH IS INCLUDED IN
THE SPECIAL PROVISIONS.
10. REFERENCE SECTION OF THE SPECIAL PROVISIONS AND STANDARD CONSTRUCTION SPECIFICATIONS
REGARDING TEMPORARY ASPHALT PATCHING REQUIREMENTS.
11. THE CONTRACTOR SHALL POTHOLE AND VERIFY LOCATIONS, ELEVATIONS, TYPES AND SIZES OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTING PIPELINES AND SHALL NOTIFY ENGINEER OF NEED TO ADJUST PIPING INSTALLATION ACCORDINGLY. POTHOLING AND TRENCH EXCAVATION SHALL SUFFICIENTLY PRECEDE LAYING OF PIPE TO ALLOW REQUIRED ELEVATION AND ALIGNMENT ADJUSTMENTS TO BE ACCOMPLISHED WITHOUT REWORK.
COMPENSATION FOR POTHOLING AND COORDINATION REQUIRED FOR RELOCATING UTILITIES SHALL BE
INCIDENTAL TO OTHER WORK PERFORMED.
12. CONTRACTOR SHALL PROVIDE ENGINEER WITH MINIMUM 24 HOURS NOTICE PRIOR TO POTHOLING. COORDINATE WITH ENGINEER TO REVIEW UTILITY INVESTIGATIONS AND TO MAKE APPROPRIATE ADJUSTMENTS FOR ANY
ALIGNMENT OR GRADE CONFLICTS.
2 28
ROW
ROW
RO
W
RO
W
R O
W
RO
W
RO
W
R O
W R
O W
R O
W
R O
W
R O
W
R O
W
R O
W
R O
W
R O
W
R O
W R
O W
R O
W R
O W
R O
W R
O W
R O
W
R O
W R
O W
R O
W R
O W
R O
W R
O W
R O
W R
O W
R O
W R
O W
R O
W R
O W
R O
W R
O W
R O
W R
O W
R O
W R
O W
R O
W R
O W
R O
W R
O W
R O
W R
O W
EP
EP
EP
EP
EP
EP
EP
EP
EP
EP
EP
EP
EP
EP
EP
EP
EP
EP
EP
EP
EP
ROW ROW ROW ROW ROW ROW ROW ROW ROW
ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
R O
W R
O W
R O
W
R O
W R
O W
R O
W R
O W
R O
W R
O W
R O
W R
O W
R O
W
RO
W
R O
W
ROW
R O
W
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW ROW ROW
ROW
ROW
R O
W R
O W
R O
W R
O W
R O
W
R O
W
R O
W
R O
W R
O W
R O
W
ROW
BH-8
BH-1BH-2
BH
-3
BH
-4
BH-5
BH-6
BH-7
BH-9
BH-10
BH-11
5 24
0 25
0 27
0 27
355355 36 0 36
5 37 0 375
0 435
C R
ES
TV
IE
W
D R
IV
E
S
COBURN ST S
H O
LI
D
AY
D
R
BOLTON TERRACE S
AL
VA
R
AD
O T
ER
R
AC
E
S
BOICE ST S
SHEET OF
SHEET TITLE
HORIZ DATUM:
VERT DATUM:
HORIZ SCALE:
VERT SCALE:
DESIGN:
DRAWN:
CHECKED:
APPROVED:
NO. DATE BYDESCRIPTION
REVISIONS
SALEM PUBLIC WORKS DEPART
MENT
NOISIVIDGNIREE
N NIGE
CRESTVIEW
WATERLINE
SHEET PREPARED BY:
245 Commercial St. SE, Suite 210 Salem, Oregon 97301
(503) 364-2002
PN:720001
NGVD29(COS)
NAD83(2011)
OREGON
EXPIRES: 06-30-2026
100901PEREG
ISTERED PROFESSIONALENGINEER
JULY 11, 2023
PAMELA GREENE V ILLA RREA
L
PAGE LAYOUT
G-03
MRN
PGV
AS SHOWN
AS SHOWN
PAO
W-01
W -0
W-02
W-03
W -0
W-05 / W-07
3 28
Point Table
Point #
Northing
465937.9331
466050.0043
466498.7265
466736.9609
466669.6596
466925.1646
466044.8334
465956.7109
466034.4905
466002.6653
465997.4757
466357.8263
466283.0243
466208.0355
466133.2187
466257.9858
466332.9520
466407.7863
466741.8504
466735.8768
466870.7677
466851.6769
466843.0336
466807.4608
466755.7427
466635.2161
466652.2451
466051.3118
466001.5322
466057.9586
465880.3312
466507.9205
466693.5204
466418.1245
466647.3069
466802.3850
466841.9009
466651.2835
466578.1133
Easting
7540707.1681
7540430.0562
7540278.1306
7540080.7308
7539454.9934
7539400.5187
7540848.3797
7540447.6577
7540424.4544
7540625.4597
7540775.6045
7540461.0037
7540458.5561
7540456.0695
7540458.2449
7540407.7177
7540410.0965
7540412.5050
7539816.8502
7539796.6599
7539820.9346
7539447.9146
7539410.9354
7539397.6624
7539415.9194
7539448.1708
7539506.4350
7540665.8215
7540662.8566
7540504.7467
7540473.1100
7540455.7944
7540345.3744
7540108.0220
7539999.4081
7539997.3177
7539906.1744
7539844.0809
7539841.1342
Elevation
446.731
408.955
359.739
305.446
226.951
236.241
434.227
419.672
408.036
434.864
437.025
390.686
391.030
396.015
402.354
390.087
383.433
381.789
266.717
265.983
267.490
233.504
233.422
231.988
229.277
226.993
228.672
433.936
435.684
414.699
432.478
379.698
358.343
354.273
315.001
287.326
276.178
281.393
290.777
Raw Description
S-CP
S-CP
S-CP
S-CP
S-CP
S-CP
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
F-MM
ROW
R O
W
R O
W R O
W
R O
W R
O W
R O
W R
O W
R O
W
R O
W
R O
W
X
X
X
X
X
X
ROW ROW
ROW ROW ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
R O
W
R O
W
R O
W
ROW
R O
W R
O W
R O
W
BH-8
BH-1BH-2
BH
-3
BH
-4
BH-5
BH-6
BH-7
BH-9
BH-10
BH-11
139 136
131 129
105 130
J:
\2
SA
LE
M
C O
R \2
8-
C
R
ES
TV
IE
W W
AT
ER
LI
N
E\ C
_D
ES
N
C
AD
\3 _D
ES
IG
N \D
_P
LA
N S-
1\ G
-0
SU
R
VE
Y
C O
N
TR
O L
SH
EE
T.
D
W G
LA
ST
S
AV
ED
: 3
/5 /2
4:
P M
PR
IN
TE
D
: 4 /2
4/
0:
A M
SHEET OF
SHEET TITLE
HORIZ DATUM:
VERT DATUM:
HORIZ SCALE:
VERT SCALE:
DESIGN:
DRAWN:
CHECKED:
APPROVED:
NO. DATE BYDESCRIPTION
REVISIONS
SALEM PUBLIC WORKS DEPART
MENT
NOISIVIDGNIREE
N NIGE
CRESTVIEW
WATERLINE
SHEET PREPARED BY:
245 Commercial St. SE, Suite 210 Salem, Oregon 97301
(503) 364-2002
PN:720001
NGVD29(COS)
NAD83(2011)
OREGON
EXPIRES: 06-30-2026
100901PEREG
ISTERED PROFESSIONALENGINEER
JULY 11, 2023
PAMELA GREENE V ILLA RREA
L
SURVEY
CONTROL SHEET
G-04
MRN
PGV
AS SHOWN
AS SHOWN
PAO
NOTES
1. BASIS OF BEARINGS AND COORDINATE SYSTEM IS BASED ON THE OREGON STATE PLANE NORTH
ZONE, NAD83(2011), EPOCH 2010.00. ALL DISTANCES SHOWN HEREON ARE GROUND DISTANCES.
2. ELEVATIONS WERE ESTABLISHED BY STATIC GPS OBSERVATIONS TO CITY OF SALEM BENCHMARK
NO. 3009. MARK IS A BRASS DISK IN THE CURB AT THE SOUTHWEST CORNER OF SALEM HEIGHTS
AVENUE S. AND WINOLA AVENUE S. ELEVATION = 441.83' (NGVD29, CITY OF SALEM DATUM)
3. THE LOCATION OF UTILITIES SHOWN HEREON ARE FROM OBSERVED VISIBLE EVIDENCE OF ABOVE
GROUND APPURTENANCES ALONG WITH SURFACE UTILITY MARKINGS BY OTHERS. ALL
UNDERGROUND UTILITIES SHOWN WERE MARKED ON THE SURFACE BY AN "OREGON ONE-CALL
NOTIFICATION CENTER" REQUEST AS WELL AS PRIVATE LOCATING SERVICE FOR THE AREA WITHIN
THE APARTMENT PROPERTY. SURVEYOR MAKES NO GUARANTEE AS TO THE ACCURACY OF SAID
MARKINGS, HOWEVER, THEY ARE LOCATED AS ACCURATELY AS THEY ARE MARKED ON THE
GROUND.
4. PER ORS 209.150, ANY SURVEY MONUMENT REMOVED, DISTURBED OR DESTROYED SHALL BE
REPLACED BY A PROFESSIONAL LAND SURVEYOR WITHIN 90 DAYS AT THE EXPENSE OF THE
PERSON OR PUBLIC AGENCY RESPONSIBLE FOR SAID REMOVAL, DISTURBANCE OR DESTRUCTION.
5. FIELD SURVEYED AUGUST, 2022.
6. THE SHOWN SURVEY CONTROL IS NOT ALL INCLUSIVE OF ALL SURVEY MONUMENTS WITHIN THE
WORK AREA.
0 80 160
ALVARADO
TERRACE
C R
ES
TV
IE
W
D R
IV
E
S
COBURN ST S
H O
LI
D
AY
D
R
BOLTON TERRACE S
AL
VA
R
AD
O T
ER
R
AC
E
S
BOICE ST S
4 28
JLR
SHEET OF
SHEET TITLE
HORIZ DATUM:
VERT DATUM:
HORIZ SCALE:
VERT SCALE:
DESIGN:
DRAWN:
CHECKED:
APPROVED:
NO. DATE BYDESCRIPTION
REVISIONS
SALEM PUBLIC WORKS DEPART
MENT
NOISIVIDGNIREE
N NIGE
CRESTVIEW
WATERLINE
SHEET PREPARED BY:
245 Commercial St. SE, Suite 210 Salem, Oregon 97301
(503) 364-2002
PN:720001
NGVD29(COS)
NAD83(2011)
OREGON
EXPIRES: 06-30-2026
100901PEREG
ISTERED PROFESSIONALENGINEER
JULY 11, 2023
PAMELA GREENE V ILLA RREA
L
J:
\2
SA
LE
M
C O
R \2
8-
C
R
ES
TV
IE
W W
AT
ER
LI
N
E\ C
_D
ES
N
C
AD
\3 _D
ES
IG
N \D
_P
LA
N S-
1\
EC
-0
EP
SC
P
LA
N .D
W G
LA
ST
S
AV
ED
: 4
/2 2/
:3
AM
PR
IN
TE
D
: 4 /2
4/
0:
A M
EPSC AND TREE
PRESERVATION
NOTES
EC-01
MRN
PGV
AS SHOWN
AS SHOWN
PAO
EROSION PREVENTION AND SEDIMENT CONTROL (EPSC) AND TREE PRESERVATION PLAN DETAILS
1. THE CONTRACTOR SHALL PROVIDE DAILY MEASURES TO ENSURE SEDIMENT
CONTROL DURING NON-WORK HOURS.
2. THE CONTRACTOR SHALL PROVIDE PROTECTION AS REQUIRED ON PRIVATE INLETS
TO ENSURE SEDIMENT CONTROL WITHIN THE WORK AREA.
3. THE PROJECT SITE SHALL HAVE A CONCRETE WASHOUT BASIN AVAILABLE PER
SALEM STD. PLAN 917 OR APPROVED EQUAL.
4. ALL TEMPORARY STOCKPILES AND CONCRETE MANAGEMENT FACILITIES SHALL BE
LOCATED A MINIMUM OF 50 FEET FROM ANY DRAINAGE INLET OR WATERCOURSE.
5. BORE, HAND DIG, OR VACUUM EXCAVATE WITHIN CRITICAL TREE ZONE. SEE DETAILS
AND CITY OF SALEM STANDARD CONSTRUCTION SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
GENERAL EPSC NOTES
EROSION CONTROL LEGEND
INSTALL SEDIMENT FENCE; RE: SALEM STD PLAN 902
TRENCH LIMITS
INSTALL BIOFILTER BAG INLET PROTECTION; RE: SALEM
STD PLAN 91402
TL
FLOW ARROW
(EXISTING CONDITIONS PRIOR TO CONSTRUCTION)
CITY OF SALEM ADMINISTRATIVE RULES
CHAPTER 109 DIVISION 007 EROSION PREVENTION AND SEDIMENT CONTROL PLAN
APPENDIX 7A EPSC PLAN STANDARD NOTES
(a) Pre-Construction (1). Prior to any land disturbing activities, the boundaries of the clearing and grading limits, vegetated buffers, and any sensitive areas shown on this plan shall be clearly delineated in the field. Unless otherwise approved, no disturbance is permitted beyond the clearing limits. The contractor must maintain the delineation for the duration of the project. Note: vegetated corridors to be delineated with orange construction fence or approved equal.
(2). BMPS that must be installed prior to land disturbing activities are construction entrance, perimeter sediment control, and inlet protection.
(3). Hold a preconstruction conference to review the EPSC and Tree Preservation Plan with the city’s project manager and inspector.
(b) Construction (1). All sediment is required to stay on site. Sediment amounts greater than ½ cubic foot which leave the site must be cleaned up within 24 hours and placed back on the site and stabilized or properly disposed.
Vacuuming or dry sweeping must be used to clean up released sediment and it must not be swept or washed into storm sewers, drainage ways, or water bodies. The cause of the sediment release must be found and prevented from causing a recurrence of the discharge within the same 24 hours. Any in-stream clean up of sediment shall be performed according to the Oregon Department of State Lands (DSL) required time frame.
(2). Construction, maintenance, replacement, and upgrading of erosion prevention and sediment control facilities is the sole responsibility of the contractor until all construction is completed,approved, and permanent erosion control (i.e., vegetation/landscaping) is established on all disturbed areas.
(3). All recommended erosion prevention and sediment control procedures are dependent on construction methods, staging, site conditions, weather, and scheduling. During the construction period, erosion control facilities shall be revised, upgraded, replaced, or added, to comply with SRC and State and Federal regulatory requirements.
(4). The contractor is solely responsible for protection of all adjacent property and downstream facilities from erosion and siltation during project construction. Any damage resulting from such erosion and siltation shall be corrected at the sole expense of the contractor.
(5). When saturated soil is present, water-tight trucks must be used to transport saturated soils from the construction site. Soil may be drained on site at a designated location, using appropriate BMPs. Soil must be drained sufficiently to drip less than one gallon per hour prior to leaving the site.
(6). All materials spilled, dropped, or washed into storm drains must be removed immediately, and the contractor shall provide protection of downstream inlets and catch basins to ensure sediment-laden water does not enter the storm drain system.
(7). All discharge of sediment-laden water must be treated with an appropriate BMP to remove sediment from discharge waters and to comply with SRC and State and Federal regulatory permits.
(8). In areas subject to wind erosion, appropriate BMPs must be used which may include the application of fine water spraying, plastic sheeting, mulching, or other approved measures.
(9). The EPSC measures and BMPs shown on this plan are the minimum requirements for anticipated site conditions. During the construction period, these measures shall be upgraded as needed to maintain compliance with all regulations.
(10). The contractor shall provide onsite water or other appropriate BMPs to prevent dust and wind erosion of fine grain soils.
(11). Disturbed areas must be stabilized after 14 days of inactivity, or immediately if rain is forecasted.
See subsection 7A.1(d)-Wet Weather Period.
(12). During the wet weather work period or when rain is forecasted, all active and inactive soil stock piles must be covered with appropriate plastic sheeting. Plastic sheeting must cover the entire stock pile and be sufficiently anchored.
(c) Pollutants, Solid Waste and Hazardous Materials Management (1). Any use of toxic or other hazardous materials must include proper storage, application, and disposal.
(2). The contractor is solely responsible to properly manage pollutants, hazardous wastes, used oils, contaminated soils, concrete waste, sanitary waste, liquid waste, or other toxic substances discovered or generated during construction to prevent leakage, spills or release of pollutants to the environment and surface waters.
(3). Contractor shall develop a project specific written spill prevention and response procedures that includes employee training on spill prevention and proper disposal procedures; regular maintenance schedule for vehicles and machinery; and material delivery and storage controls, signage, material use, and use of covered storage areas for waste and supplies. The plan shall comply with SRC and Federal and State requirements, and shall be available on site at all times.
(d) Wet Weather Period (October 15 through April 30) (1). Construction activities must avoid or minimize the duration of disturbed areas.
(2). Temporary stabilization of the site including covering of bare soils with approved BMPs, must be installed at the end of the shift before a holiday or weekend, or at the end of each workday if rainfall is forecast in the next 24 hours.
(3). Temporary stabilization or covering of soil stockpiles and protection of stockpiles located away from construction activity must occur at the end of each workday.
(e) Maintenance (1). Erosion control measures shall be maintained in such a manner as to ensure that erosion is prevented and sediment-laden water does not enter a drainage system, roadway, or violate applicable water quality standards.
(2). Sediment shall not be washed or swept into storm sewers, drainage ways, or water bodies.
(3). Sediment must be removed from behind all sediment control measures when it has reached a height of 1/3 the barrier height, and prior to the control measures removal.
(4). Removal of trapped sediment in a sediment basin or sediment trap or catch basins must occur when the sediment retention capacity has been reduced by 50 percent; is not functioning properly and/or at the completion of project.
(5). Cleaning of all structures, inlet protection BMPs, and sump pumps must be completed regularly and as required to ensure structures and inlets function properly and flow freely.
(6). Construction site exits shall be maintained in a condition that will prevent tracking or flow of mud onto the row or approved access point. The entrance may require periodic top dressing as conditions demand, and repair and/or cleanout of any structures used to trap sediment. Wheel washing shall be required to prevent sediment and material tracking on road surfaces if passive BMPs are not effective.
(f) Inspection (1). The EPSC must be kept onsite at all times. All measures shown on the plan must be installed properly to ensure compliance with SRC and State and Regulatory permits, and that sediment does not enter a surface water system, roadway, or other properties.
(2). Written EPSC inspection logs shall be maintained onsite and available to city inspectors upon request.
(3). All BMPs shall be inspected at least every week. When a rainfall event exceeds ½" in a 24-hour period, daily inspection of the erosion controls, sediment controls, and discharge outfalls must be conducted and documented. Inspections shall be done by a representative of the permit registrant who is knowledgeable and experienced in the principles, practices, installation, and maintenance of erosion and sediment controls.
(g) Inactive Construction Periods and Post-Construction (1). Should work cease in any area for 14 days, the inactive area must be stabilized with appropriate soil stabilization BMPs. If all construction activity ceases the entire site must be temporarily stabilized using vegetation, heavy mulch layer, temporary seeding, or other method.
(2). All temporary erosion prevention and sediment control facilities shall be removed by the contractor within 30 days after permanent landscaping/vegetation is established and the threat of erosion and sediment transport has been mitigated.
(3). Temporary grass cover measures must be fully established by October 15 or other cover measures (i.e., erosion control blankets with anchors, one-inch of straw mulch, six mil HDPE plastic sheet, etc.)
shall be in place over all disturbed soil areas until April 30. To establish an adequate grass stand for controlling erosion by October 15, it is recommended that seeding and mulching occur by September 1.
(4). Permanent erosion control vegetation on all embankments and disturbed areas shall be re-established as soon as construction is completed.
(h) Specifications (1). Soil preparation. Topsoil should be prepared according to the landscape plans, if available, or recommendations of the grass seed supplier. Slopes shall be textured before seeding by rack walking (i.e., driving a crawling tractor up and down the slopes to leave a pattern of cleat imprints parallel to slope contours) or other method to provide stable areas for seeds to rest.
(2). Seeding. Erosion control grass seed mix shall be as follows: Dwarf grass mix (low height, low maintenance) consisting of dwarf perennial ryegrass (80 percent by weight), creeping red fescue (20 percent by weight). Application rate shall be 100 pounds per acre minimum.
(3). Grass seed shall be fertilized at a rate of ten pounds per 1,000 square feet with 16-16-16 slow release type fertilizer. Disturbed areas within 50 feet of water bodies and wetlands must use a non-phosphorous fertilizer.
(4). The application rate of fertilizers used to reestablish vegetation shall follow manufacturer's recommendations. Nutrient releases from fertilizers to surface waters shall be minimized. Time release fertilizers shall be used. Care shall be made in the application of fertilizers within any waterway riparian zone to prevent leaching into the waterway.
(5). When used, hydromulch shall be applied with grass seed at a rate of 2,000 pounds per acre between April 30 and June 10, or between September 1 and October 1. On slopes steeper than ten percent, hydroseed and mulch shall be applied with a bonding agent (tackifier). Application rate and methodology shall be in accordance with seed supplier recommendations.
(6). When used in lieu of hydromulch, dry, loose, weed-free straw used as mulch shall be applied at a rate of 4,000 pounds per acre (double the hydromulch application requirement). Anchor straw by working in by hand or with equipment (rollers, cleat trackers, etc.). Mulch shall be spread uniformly immediately following seeding.
(7). When conditions are not favorable to germination and establishment of the grass seed, the Contractor shall irrigate the seeded and mulched areas as required to establish the grass cover.
(8). Sediment fences shall be constructed of continuous filter fabric to avoid use of joints. When joints are necessary, filter cloth shall be spliced together only at a support post, with a minimum six-inch overlap, and both ends securely fastened to a post.
(9). The standard strength filter fabric shall be fastened securely to stitched loops installed on the upslope side of the posts, and six inches of the fabric shall be extended into the trench. The fabric shall not extend more than 30 inches above the original ground surface. Filter fabric shall not be stapled to existing trees.
(10). Bio-filter bags shall be clean 100 percent wood product waste. Bags shall be 18-inch x 18-inch x 30-inch, weigh approximately 45 pounds, and be contained in a bag made of ½ inch plastic mesh.
(11). Minimum wet weather slope protection. For 3H:1V or steeper slopes use Bon Terra Type C2 or North American Green Type C125 erosion control blankets. Use a minimum of two inches straw mulch or North American Green Type S150 for slopes flatter than 3H:1V and greater than 6H:1V. Slopes flatter than 6H:1V use one inch straw mulch, hydroseed with hydromulch and tackifier. Slope protection shall be placed on all disturbed areas immediately after completion of each section of construction activity, until the erosion control seeding has been established. As an option during temporary or seasonal work stoppages, a six-mil HDPE plastic sheet may be placed on exposed slopes. The plastic sheet shall be provided with an anchor trench at the top and bottom of the slope, and shall be sandbagged on the slopes as required to prevent damage or displacement by wind.
DESIGN STANDARDS NOTES
INSTALL TREE PROTECTION FENCE; RE: SALEM STD
PLANS 820 AND 82104
INSTALL WATTLE OVERLAND FLOW BARRIER IN J-HOOK
CONFIGURATION; RE: SALEM STD PLAN 903
OR
EROSION CONTROL WORK LIMITSWL
8 28
INSTALL INLET PROTECTION SILT SACK; RE: SALEM STD
PLAN 913. THIS IS REQUIRED ON ALL INLETS RECEIVING
FLOW FROM THE PROJECT
R O
W
R O
W
R O
W
R O
W
R O
W R
O W
R O
W R
O W
R O
W R
O W
R O
W R
O W
R O
W
R O
W
R O
W
R O
W
R O
W
R O
W
R O
W
R O
W
EP
EP
EP
EP
EP
EP
X
X
XXXXX
XXXXXXXXXX
EP
EP
EP EP EPEPEP
EP
X
X
R O
W
R O
W
R O
W
ROW
<1 0'
'S D
<1 0'
'S D
<8''SD
<8''SD
<8''SD
<8''SD
<8''SD
<8''SD <8''SD <8''SD <8''SD <8''SD <8''SD <8''SD <8''SD
<8''SD
SD SD
SD
''S
D
''S
D
''S
D
0 26 5 27
0 27
30+00
31+00 32+00 33+00
+0
+5
31+50 32+50 33+50
34+50
60+00
H O
LI
D
AY
D
R S
C R
ES
TV
IE
W
D R
S
RO
W
RO
W
RO
W
RO
W
X
X
X
X
X X
X
ROW ROW ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROWROWROW
ROW
ROW
ROW
ROW
ROW
ROW
ROWROWROW
RO
W
ROW
R O
W
<10''SD
<10''SD
<10''SD
<10''SD
<10''SD
<1 0'
'S D
<1 0'
'S D
<8 ''S
D
<8 ''S
D
<8 ''S
D
5 29
0 29 5 30
0 30
34+00
35+00 36+00
37+00
38+00
34+50
35+50 36+50
37+50
60+00
61+00
COBURN ST S
J:
\2
SA
LE
M
C O
R \2
8-
C
R
ES
TV
IE
W W
AT
ER
LI
N
E\ C
_D
ES
N
C
AD
\3 _D
ES
IG
N \D
_P
LA
N S-
1\
EC
-0
EP
SC
P
LA
N .D
W G
LA
ST
S
AV
ED
: 4
/2 2/
:3
AM
PR
IN
TE
D
: 4 /2
4/
0:
A M
0 20 40
SHEET OF
SHEET TITLE
HORIZ DATUM:
VERT DATUM:
HORIZ SCALE:
VERT SCALE:
DESIGN:
DRAWN:
CHECKED:
APPROVED:
NO. DATE BYDESCRIPTION
REVISIONS
SALEM PUBLIC WORKS DEPART
MENT
NOISIVIDGNIREE
N NIGE
CRESTVIEW
WATERLINE
SHEET PREPARED BY:
245 Commercial St. SE, Suite 210 Salem, Oregon 97301
(503) 364-2002
PN:720001
NGVD29(COS)
NAD83(2011)
OREGON
EXPIRES: 06-30-2026
100901PEREG
ISTERED PROFESSIONALENGINEER
JULY 11, 2023
PAMELA GREENE V ILLA RREA
L
EPSC AND TREE
PRESERVATION
PLAN
EC-02
MRN
PGV
AS SHOWN
AS SHOWN
PAO
RE:
MATCHLINE
BELOW
RE
M
AT
CH
LI
NE
EC
-0
RE:
MATCHLINE
ABOVE
KEYNOTES-
WILLAMETTE VIEW
APARTMENTS
2332 CRESTVIEW DR S
2510 CRESTVIEW DR S 2614 CRESTVIEW DR S
888 COBURN ST S
CITY VIEW CEMETERY
390 HOYT ST S
WILLAMETTE VIEW
APARTMENTS
2332 CRESTVIEW DR S
800 BLK COBURN ST S
888 COBURN ST S
2525 COBURN ST S
20' PERMANENT UTILITY
EASEMENT (PUE-1)
10' PERMANENT UTILITY
EASEMENT (PUE-2)
20' PERMANENT
UTILITY EASEMENT
(PUE-1)
10' PERMANENT
UTILITY EASEMENT
(PUE-2)
MT LAUREL WAY S
02 TL
WL
WL
TL
9 28
INSTALL INLET PROTECTION SILT SACK; RE:
SALEM STD PLAN 913. THIS IS REQUIRED ON
ALL INLETS RECEIVING FLOW FROM THE
PROJECT
FLOW ARROW
(EXISTING CONDITIONS PRIOR TO
CONSTRUCTION)
OR
INSTALL SEDIMENT FENCE; RE: SALEM STD
PLAN 902
INSTALL BIOFILTER BAG INLET PROTECTION;
RE: SALEM STD PLAN 914
INSTALL WATTLE OVERLAND FLOW
BARRIER IN J-HOOK CONFIGURATION; RE:
SALEM STD PLAN 903
TL TRENCH LIMITS
INSTALL TREE PROTECTION FENCE; RE:
SALEM STD PLANS 820 AND 821
WL EROSION CONTROL WORK LIMITS
WL
EP
X
X
X
X
X
X
X
X
X X
X
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
R O
W
RO
W
RO
W ROW
R O
W
R O
W
ROW
ROW
ROW
ROW
ROW
<10''SD
<1 0''
SD
<1 0''
SD
<10''SD
<10''SD
<10''SD
<10''SD
<10''SD
<10''SD
<10''SD
<10''SD
<10''SD
<10''SD
38+00
39+00
40+00
41+00
42+00
38+50
39+50
40+50
41+50
BOLT
ON TERRACE S
COBURN ST S
COBURN ST S
ROWROWROWROWROWROWROW
ROWROWROWROWROWROWROW
EP
EP
ROW
ROW
ROW
ROW
ROW
ROW ROW ROW
ROW
ROW ROW ROW
ROW
10''SD>
<1 0'
'S D
SDSD
0 39
+0
43+00 44+00
45+00
46+00
41+50
42+50 43+50 44+50
45+50
ALVARADO TERRACE S
0 20 40
SHEET OF
SHEET TITLE
HORIZ DATUM:
VERT DATUM:
HORIZ SCALE:
VERT SCALE:
DESIGN:
DRAWN:
CHECKED:
APPROVED:
NO. DATE BYDESCRIPTION
REVISIONS
SALEM PUBLIC WORKS DEPART
MENT
NOISIVIDGNIREE
N NIGE
CRESTVIEW
WATERLINE
SHEET PREPARED BY:
245 Commercial St. SE, Suite 210 Salem, Oregon 97301
(503) 364-2002
PN:720001
NGVD29(COS)
NAD83(2011)
OREGON
EXPIRES: 06-30-2026
100901PEREG
ISTERED PROFESSIONALENGINEER
JULY 11, 2023
PAMELA GREENE V ILLA RREA
L
J:
\2
SA
LE
M
C O
R \2
8-
C
R
ES
TV
IE
W W
AT
ER
LI
N
E\ C
_D
ES
N
C
AD
\3 _D
ES
IG
N \D
_P
LA
N S-
1\
EC
-0
EP
SC
P
LA
N .D
W G
LA
ST
S
AV
ED
: 4
/2 2/
:3
AM
PR
IN
TE
D
: 4 /2
4/
0:
A M
EPSC AND TREE
PRESERVATION
PLAN
EC-03
MRN
PGV
AS SHOWN
AS SHOWN
PAO
R E:
M
AT
C H
LI
N
E
EC
-0
R E:
M
AT
C H
LI
N
E
BE
LO
W
RE:
MATCHLINE
ABOVE
R E:
M
ATC
H
LIN
E
EC
-04
KEYNOTES-
800 BLK COBURN ST S
2519 COBURN ST S
2515 COBURN ST S
2525 COBURN ST S
2530 BOLTON
TERRACE S
2535 ALVARADO
TERRACE S
2490 ALVARADO
TERRACE S
2530 ALVARADO
TERRACE S
2540 ALVARADO
TERRACE S
2560 ALVARADO
TERRACE S
2570 ALVARADO
TERRACE S
2580 ALVARADO
TERRACE S
2535 ALVARADO
TERRACE S 2545 ALVARADO
TERRACE S 2565 ALVARADO
TERRACE S
2575 ALVARADO
TERRACE S 2585 ALVARADO
TERRACE S
TL
WL
TL
WL
INSTALL INLET PROTECTION SILT SACK; RE:
SALEM STD PLAN 913. THIS IS REQUIRED ON
ALL INLETS RECEIVING FLOW FROM THE
PROJECT
FLOW ARROW
(EXISTING CONDITIONS PRIOR TO
CONSTRUCTION)
OR
INSTALL BIOFILTER BAG INLET PROTECTION;
RE: SALEM STD PLAN 914
TL TRENCH LIMITS
WL EROSION CONTROL WORK LIMITS
10 28
ROW ROW ROW ROW ROW ROW ROW ROW ROW
ROW ROW ROW ROW ROW ROW ROW ROW ROW ROW
ROW
R O
W
R O
W R
O W
R O
W
R O
W
R O
W
R O
W
RO
W
ROW
<8''SD <8''SD <8''SD <8''SD
6' 'S
D
8''
SD>
<10''SD
<10''SD
<10''SD
''S
D
''S
D
0 42
5 43
46+00
47+00 48+00 49+00
46+50
47+50 48+50 49+50
71+00 72+00 73+00
BOICE ST S
ALVARADO
TERRACE S
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
X
X
X
X
R O
W R
O W
R O
W
R O
W
R O
W
ROW
ROW
ROW
ROW
ROW
ROW
RO
W
ROW
<10''SD
<10''SD
<8''SD
<8''SD
34+00 35+00
33+50
34+50
35+50
60+00
61+00
HOLIDAY DR S
0 20 40
SHEET OF
SHEET TITLE
HORIZ DATUM:
VERT DATUM:
HORIZ SCALE:
VERT SCALE:
DESIGN:
DRAWN:
CHECKED:
APPROVED:
NO. DATE BYDESCRIPTION
REVISIONS
SALEM PUBLIC WORKS DEPART
MENT
NOISIVIDGNIREE
N NIGE
CRESTVIEW
WATERLINE
SHEET PREPARED BY:
245 Commercial St. SE, Suite 210 Salem, Oregon 97301
(503) 364-2002
PN:720001
NGVD29(COS)
NAD83(2011)
OREGON
EXPIRES: 06-30-2026
100901PEREG
ISTERED PROFESSIONALENGINEER
JULY 11, 2023
PAMELA GREENE V ILLA RREA
L
J:
\2
SA
LE
M
C O
R \2
8-
C
R
ES
TV
IE
W W
AT
ER
LI
N
E\ C
_D
ES
N
C
AD
\3 _D
ES
IG
N \D
_P
LA
N S-
1\
EC
-0
EP
SC
P
LA
N .D
W G
LA
ST
S
AV
ED
: 4
/2 2/
:3
AM
PR
IN
TE
D
: 4 /2
4/
0:
A M
EPSC AND TREE
PRESERVATION
PLAN
EC-04
MRN
PGV
AS SHOWN
AS SHOWN
PAO
RE:
MATCHLINE
EC-03
02 05
KEYNOTES-
2595 ALVARADO
TERRACE S
2635 ALVARADO
TERRACE S
2620 ALVARADO
TERRACE S
2590 ALVARADO
TERRACE S
685 BOICE
STREET S
685 BOICE
STREET S
645 BOICE
STREET S
WILLAMETTE VIEW
APARTMENTS
2332 CRESTVIEW DR S
2614 CRESTVIEW DR S
888 COBURN ST S
2332 CRESTVIEW DR S
CITY OF SALEM CANDALARIA
RESERVOIR
10' PERMANENT
UTILITY EASEMENT
(PUE-2)
WL
WL
INSTALL INLET PROTECTION SILT SACK; RE:
SALEM STD PLAN 913. THIS IS REQUIRED ON
ALL INLETS RECEIVING FLOW FROM THE
PROJECT
FLOW ARROW
(EXISTING CONDITIONS PRIOR TO
CONSTRUCTION)
OR
INSTALL SEDIMENT FENCE; RE: SALEM STD
PLAN 902
INSTALL BIOFILTER BAG INLET PROTECTION;
RE: SALEM STD PLAN 914
TL TRENCH LIMITS
INSTALL TREE PROTECTION FENCE; RE:
SALEM STD PLANS 820 AND 821
WL EROSION CONTROL WORK LIMITS
TL
11 28
29+90 30+00 31+00 32+00 33+00 34+00
EXISTING GRADE
@ PIPELINE
ST
A:
+0
2.
IE
:2
ST
A:
+2
8.
IE
:2
.8
"x
"x
" T
EE
(F Lx
FL
xF
L)
ST
A:
+6
9.
IE
:2
.0
ST
A:
+7
8.
IE
:2
.1
SEE ADJACENT SHEET
FOR PIPE LENGTH
AND SLOPE
ST
A:
+5
0.
IE
:2
.0
EX
(2
) 2 " C
AT
V
ST
A:
0+
.9
EX
" C O
M M
ST
A:
0+
.4
EX
E
LE
C
ST
A:
0+
.4
EX
E
LE
C
ST
A:
0+
.8
EX
E
LE
C
ST
A:
0+
.0
ST
A:
+8
8.
IE
:2
.9
EX
/2 " C
O M
M
ST
A:
0+
.1
EX SS SERVICE
STA: 31+12.61
EX SS SERVICE
STA: 32+10.72
ST
A:
+3
7.
IE
:2
.1
EX SS SERVICE
STA: 33+21.02
ST
A:
+6
9.
IE
:2
.0
ST
A:
+6
0.
IE
:2
.3
N O
T
FO
U N
D D
U R
IN
G
U
TI
LI
TY
P O
TH
O
LI
N
G
N O
T
FO
U N
D D
U R
IN
G
U
TI
LI
TY
P O
TH
O
LI
N
G
N O
T
FO
U N
D D
U R
IN
G
U
TI
LI
TY
P O
TH
O
LI
N
G
EX 8" SS
STA: 30+57.12
EX 8" SS
STA: 30+17.35
19.0 LF -18"
PIPE @ -0.00% 110.8 LF -18"
PIPE @ -7.92%
21.2 LF -18"
PIPE @ +7.10%
9.0 LF -18"
PIPE @ -24.26%
21.6 LF -18"
PIPE @ +3.68%
81.0 LF -18"
PIPE @ -12.46%
67.7 LF -18"
PIPE @ -10.50%
22.4 LF -18"
PIPE @ -5.24%
R O
W
R O
W
R O
W
R O
W
R O
W R
O W
R O
W R
O W
R O
W R
O W
R O
W R
O W
R O
W
R O
W
R O
W
R O
W
R O
W
R O
W
R O
W
R O
W
EP
EP
EP
EP
EP
EP
X
X
XXXXX
XXXXXXXXXX
EP
EP
EP EP EPEPEP
''W
''W
''W
''W
''W
''W
''W
8' 'W
8' 'W
8' 'W
8' 'W
T
T
T T
T T
T T
T T
T T
T T
T
T T
O H
P
O H
P
O H
P
OHP
OHP
EP
UGP UGP
U G
P U
G P
U G
P U
G P
UGP
UGP
UGP
UGP
UGP
UGP
UGP
UGP UGP
U G
P
UGP
UGP
UGP
UGP
UGP
UGP
U
G P
UGP
UGP
X
<8 ''S
S
<8 ''S
S
8' 'S
S>
8' 'S
S>
8' 'S
S>
8' 'S
S>
<8''SS <8''SS <8''SS <8''SS <8''SS <8''SS <8''SS <8''SS <8''SS <8''SS <8''SS <8''SS <8''SS <8''SS
<8''SS
<8''SS
<8''SS <8''SS
8' 'S
S>
8' 'S
S>
8' 'S
S>
8' 'S
S> <8
''S S
<8 ''S
S <8
''S S
<8 ''S
S <8
''S S
6' 'W
6' 'W
6' 'W
X
R O
W
R O
W
R O
W
ROW
TV
BH-10
BH-11
N G
N G
N G
N G
N G
N G
N G
N G
<1 0'
'S D
<1 0'
'S D
<8''SD
<8''SD
<8''SD
<8''SD
<8''SD
<8''SD <8''SD <8''SD <8''SD <8''SD <8''SD <8''SD <8''SD
<8''SD
SD SD
SD
''S
D
''S
D
''S
D
1' 'N
G
1' 'N
G
1' 'N
G
SS
SS SS
SS
SS
8''W 8''W
30+00
31+00 32+00 33+00
+0
+5
31+50 32+50 33+50
34+50
STA: 30+69.11
N: 466660.15 E:7539491.37
45° BEND (MJxMJ)
STA: 30+78.09
N: 466668.12 E:7539495.52
45° BEND (MJxMJ)
STA: 30+28.49
N: 466620.56 E:7539496.56 18"(N) x 18"(S) x 12"(W) DI TEE (FLxFLxFL) W/BLIND FLANGES
ON 12"(W) AND 18"(S)
STA: 30+50.13
N: 466642.18 E:7539497.48 22.5° BEND (MJxMJ)
STA: 33+80.26
N: 466752.57 E:7539785.65
45° BEND (MJxMJ)
STA: 33+94.65
N: 466765.18 E:7539792.57 11.25° BEND (MJxMJ)
STA: 33+99.65
N: 466769.99 E:7539793.93 11.25° BEND (MJxMJ)
STA: 34+39.06
N: 466809.36 E:7539795.83
45° BEND (MJxMJ)
STA: 34+46.25
N: 466814.28 E:7539801.07
45° BEND (MJxMJ)
01 CONSTRUCT DUCTILE IRON PIPE CONFORMING
TO AWWA C151, CLASS 52 (SIZE AS SHOWN). ALL
PIPES SHALL BE CEMENT-MORTAR LINED
CONFORMING TO AWWA C104 PER
SPECIFICATIONS. MAINTAIN MINIMUM 36" COVER
FROM FINISH TO GRADE. ALL PIPE JOINTS AND
FITTINGS SHALL BE RESTRAINED AS INDICATED
IN SPECIFICATIONS; RE: SALEM STD PLANS 601
AND 605
02 DEFLECT PIPE VERTICALLY. MAXIMUM
DEFLECTION PER MANUFACTURER'S
RECOMMENDATION
05 BORE, HAND DIG, OR VACUUM EXCAVATE
WITHIN CRITICAL TREE ZONE. SEE DETAILS AND
CITY OF SALEM STANDARD CONSTRUCTION
SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS; RE: EPSC AND TREE
PRESERVATION PLANS
06 DEFLECT PIPE HORIZONTALLY. MAXIMUM
DEFLECTION PER MANUFACTURER'S
RECOMMENDATION
26 POTENTIAL SS SERVICE LINE CONNECTION 8"
SS. NOT LOCATED ON GIS AND/OR SURVEY
31 RETAIN AND PROTECT
33 POTHOLE SERVICE CONNECTION TO CONFIRM
DEPTH. IF WATER SERVICES CONFLICT,
CONTACT CITY FOR FURTHER INSTRUCTION
43 IF REQUIRED, REPLACE SEWER MAIN OR
LATERAL WITH ONE FULL SECTION OF PVC
PRESSURE PIPE (ASTM D-2241, SDR-32.5),
CENTERED AT THE CROSSING POINT PER OAR
333-061-0050; SEE GENERAL SHEET NOTE 3
44 POTHOLED BY VACX, APRIL 5, 2023
48 PLEASE REFER TO SPECIFICATIONS FOR
AVAILABLE SUBSURFACE DATA REPORT BY
GEOENGINEERS, SEPTEMBER 27, 2022
50 CONTRACTOR TO DEFLECT PIPE TO MAINTAIN
10' SEPARATION FROM SANITARY SEWER LINE
J:
\2
SA
LE
M
C O
R \2
8-
C
R
ES
TV
IE
W W
AT
ER
LI
N
E\ C
_D
ES
N
C
AD
\3 _D
ES
IG
N \D
_P
LA
N S-
1\ W
-0
PL
AN
A N
D P
R O
FI
LE
KA
.D W
G
LA
ST
S
AV
ED
: 3 /5
/2
7:
P
M
PR
IN
TE
D : 1
/1 2/
:1
PM
CITY FORCES SHALL
SHEET OF
SHEET TITLE
HORIZ DATUM:
VERT DATUM:
HORIZ SCALE:
VERT SCALE:
DESIGN:
DRAWN:
CHECKED:
APPROVED:
NO. DATE BYDESCRIPTION
REVISIONS
SALEM PUBLIC WORKS DEPART
MENT
NOISIVIDGNIREE
N NIGE
CRESTVIEW
WATERLINE
SHEET PREPARED BY:
245 Commercial St. SE, Suite 210 Salem, Oregon 97301
(503) 364-2002
PN:720001
NGVD29(COS)
NAD83(2011)
OREGON
EXPIRES: 06-30-2026
100901PEREG
ISTERED PROFESSIONALENGINEER
JULY 11, 2023
PAMELA GREENE V ILLA RREA
L
WATERLINE PLAN &
PROFILE
W-01
C R
ES
TV
IE
W
D R
S
A ABANDON
C CONNECT EXISTING TO NEW MAIN
CRESTVIEW DR S
MRN
PGV
AS SHOWN
AS SHOWN
PAO
C
C
RESTRAIN ALL JOINTS
CLASS B BACKFILL
NEW 18" DI W
NEW 18" DI W
RE:
MATCHLINE STA
W-02
34+00
20' PERMANENT
UTILITY EASEMENT
(PUE-1)
A1
W-08
18"
MIN
18"
MIN
STA 30+00 TO 34+00
NEW 8" DI PIPE;
RE: W-06
18"
MIN
18"
MIN
18"
MIN
MIN 36" OF
COVER
STA 30+35.74
18" BUTTERFLY VALVE (FLxMJ)
31 31
SHEET KEYNOTES
GENERAL SHEET NOTES
1. EXISTING UTILITIES ARE SHOWN IN AN
APPROXIMATE LOCATION. CONTRACTOR TO
VERIFY EXISTING UNDERGROUND UTILITIES
PRIOR TO CONSTRUCTION. PLEASE REFER TO
SPECIFICATIONS FOR AVAILABLE POTHOLING
REPORT BY VACX, APRIL 5, 2023.
2. MAINTAIN MINIMUM SEPARATION FROM SANITARY
SEWER LINES PER OAR 333. MAINTAIN MINIMUM
12" VERTICAL SEPARATION FROM ALL OTHER
UTILITIES.
3. IF MINIMUM SEPARATION REQUIREMENTS PER
OAR 333 ARE NOT ACHIEVED, REPLACE ONE
SECTION OF SEWER LATERAL AND /OR SEWER
MAIN WITH PVC PRESSURE PIPE (ASTM D-2241,
SDR-32.5) AND CENTER AT THE CROSSING POINT
PER WITH ONE LENGTH OF DUCTILE IRON
WATERLINE (ALSO CENTERED) PER OAR
333-061-0050. SEWER LATERALS SHALL BE
REPLACED WITH 4" DIAMETER PIPE AND SEWER
MAINS SHALL BE REPLACED WITH 8" DIAMETER
PIPE; RE: CITY OF SALEM STANDARD
CONSTRUCTION SPECIFICATIONS AND SPECIAL
PROVISIONS.
4. RETAIN AND PROTECT ALL UTILITY CROSSINGS
UNLESS NOTED OTHERWISE.
5. CONTRACTOR MAY UTILIZE REDUCED/ALTERNATE
NUMBER OF FITTINGS TO ACHIEVE DESIGNED
ALIGNMENT AND PROFILE, PROVIDE SUGGESTED
CHANGE TO ENGINEER FOR APPROVAL.
WILLAMETTE VIEW
APARTMENTS
2332 CRESTVIEW DR S
2510 CRESTVIEW DR S 2614 CRESTVIEW DR S
888 COBURN ST S
A1
W-08
GRAPHIC SCALE
HORIZ:
VERT:
0 5 10
0 20 40
H O
LI
D
AY
D
R
44 44
43 43
44 44 44
TO BE INSTALLED
BY CITY
26 43
12 28
34+00 35+00 36+00
36+00 37+00 38+00
EXISTING GRADE
@ PIPELINE
EXISTING GRADE
@ PIPELINE
ST
A:
+5
4.
IE
:2
.3
° B
EN
D (M
Jx M
J)
ST
A:
+0
7.
IE
:2
.6
"x 8"
T
EE
(F Lx
FL
xF
L)
ST
A:
+4
6.
IE
:2
.9
ST
A:
+3
0.
IE
:2
.0
ST
A:
+6
4.
IE
:2
.7
.2 5°
B
EN
D (M
Jx M
J)
ST
A:
+8
0.
IE
:2
.1
.5 ° B
EN
D
(M Jx
M J)
EX 8" SD
STA: 34+20.01
EX 10" SD
STA: 34+51.69
ST
A:
+6
8.
IE
:2
.3
ST
A:
+0
7.
IE
:2
.1
SEE ADJACENT SHEET
FOR PIPE LENGTH
AND SLOPE
EX SD
EX 8" SS
STA: 36+92.00
ST
A:
+8
6.
IE
:2
.1
109.8 LF -18"
PIPE @ -6.75%
11.8 LF -18"
PIPE @ -8.38%16.1 LF -18"
PIPE @ -58.26%
9.9 LF -18"
PIPE @ -95.15%
94.63 LF -18"
PIPE @ -0.00%
38.2 LF -18"
PIPE @ -23.12%
60.6 LF -18"
PIPE @ -20.15%
25.7 LF -18"
PIPE @ -9.80%
17.8 LF -18"
PIPE @ +21.48%
21.2 LF -18"
PIPE @ -0.00%
38.4 LF -18"
PIPE @ +21.48%
EX 8" SS
STA: 36+92.00
EX 8" SS
STA: 36+92.00
EX 4" SS SERVICE LINE
STA: 36+67
EX 4" SS SERVICE LINE
STA: 36+14
EX 8" SS
STA: 36+92.00
EX 8" SS
STA: 36+92.00
EX 8" SS
STA. 34+90.65
RO
W
RO
W
RO
W
RO
W
X
X
X
X
X
X X
X
UGP
U G
P
UGP
U G
P U
G P
<8''SS
<8''SS
<8''SS <8''SS <8''SS <8''SS <8''SS <8''SS
<8''SS
<8''SS
<8''SS
<8''SS
<8''SS
<8 ''S
S <8
''S S
<8 ''S
S
8' 'S
S>
<8''SS
<8''SS
ROW ROW ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROWROWROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROWROWROW
RO
W
ROW
R O
W
BH-8
BH-7
BH-9
<10''SD
<10''SD
<10''SD
<10''SD
<10''SD
<1
0' 'S
D
<1 0'
'S D
<8 ''S
D
<8 ''S
D
<8 ''S
D
SS
34+00
35+00 36+00
37+00
38+00
34+50
35+50 36+50
37+50
STA: 35+20.74
N: 466813.10 E:7539875.56 22.5° BEND (MJxMJ)
STA: 33+99.65
N: 466769.99 E:7539793.93 11.25° BEND (MJxMJ)
STA: 34+39.06
N: 466809.36 E:7539795.83
45° BEND (MJxMJ)
STA: 34+46.25
N: 466814.28 E:7539801.07
45° BEND (MJxMJ)
STA: 36+30.45
N: 466769.53 E:7539976.24 11.25° BEND (MJxMJ)
STA: 36+68.81
N: 466748.52 E:7540008.36
45° BEND (MJxMJ)
STA: 37+07.86
N: 466756.57 E:7540046.57 45° BEND (MJxMJ)
STA: 37+46.06
N: 466735.67 E:7540078.56 11.25° BEND (MJxMJ)
STA: 35+07.79
N: 466813.31 E:7539862.61
18"x8" DI TEE (FLxFLxFL)
01 CONSTRUCT DUCTILE IRON PIPE CONFORMING
TO AWWA C151, CLASS 52 (SIZE AS SHOWN). ALL
PIPES SHALL BE CEMENT-MORTAR LINED
CONFORMING TO AWWA C104 PER
SPECIFICATIONS. MAINTAIN MINIMUM 36" COVER
FROM FINISH TO GRADE. ALL PIPE JOINTS AND
FITTINGS SHALL BE RESTRAINED AS INDICATED IN
SPECIFICATIONS; RE: SALEM STD PLANS 601 AND
02 DEFLECT PIPE VERTICALLY. MAXIMUM
DEFLECTION PER MANUFACTURER'S
RECOMMENDATION
05 BORE, HAND DIG, OR VACUUM EXCAVATE WITHIN
CRITICAL TREE ZONE. SEE DETAILS AND CITY OF
SALEM STANDARD CONSTRUCTION
SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS; RE: EPSC AND TREE
PRESERVATION PLANS
06 DEFLECT PIPE HORIZONTALLY. MAXIMUM
DEFLECTION PER MANUFACTURER'S
RECOMMENDATION
19 TREES SHALL BE REMOVED BY CITY OF SALEM
PRIOR TO START OF PROJECT. CONTRACTOR TO
REMOVE AND GRIND OUT STUMPS IN
ACCORDANCE WITH SALEM REVISED CODE (SRC)
CHAPTER 86 AND CHAPTER 808; RE: EPSC AND
TREE PRESERVATION PLANS AND CITY OF SALEM
STANDARD CONSTRUCTION SPECIFICATIONS
26 POTENTIAL SS SERVICE LINE CONNECTION 8" SS.
NOT LOCATED ON GIS AND/OR SURVEY
31 RETAIN AND PROTECT
43 IF REQUIRED, REPLACE SEWER MAIN OR
LATERAL WITH ONE FULL SECTION OF PVC
PRESSURE PIPE (ASTM D-2241, SDR-32.5),
CENTERED AT THE CROSSING POINT PER OAR
333-061-0050; SEE GENERAL SHEET NOTE 3
48 PLEASE REFER TO SPECIFICATIONS FOR
AVAILABLE SUBSURFACE DATA REPORT BY
GEOENGINEERS, SEPTEMBER 27, 2022
49 CONTRACTOR TO UTILIZE NATIVE MATERIAL FOR
BACKFILL OUTSIDE OF PAVED AREAS
50 CONTRACTOR TO DEFLECT PIPE TO MAINTAIN 10'
SEPARATION FROM SANITARY SEWER LINE
J:
\2
SA
LE
M
C O
R \2
8-
C
R
ES
TV
IE
W W
AT
ER
LI
N
E\ C
_D
ES
N
C
AD
\3 _D
ES
IG
N \D
_P
LA
N S-
1\ W
-0
PL
AN
A N
D P
R O
FI
LE
KA
.D W
G
LA
ST
S
AV
ED
: 3 /5
/2
7:
P
M
PR
IN
TE
D : 1
/1 2/
:1
PM
CITY FORCES SHALL
SHEET KEYNOTES
SHEET OF
SHEET TITLE
HORIZ DATUM:
VERT DATUM:
HORIZ SCALE:
VERT SCALE:
DESIGN:
DRAWN:
CHECKED:
APPROVED:
NO. DATE BYDESCRIPTION
REVISIONS
SALEM PUBLIC WORKS DEPART
MENT
NOISIVIDGNIREE
N NIGE
CRESTVIEW
WATERLINE
SHEET PREPARED BY:
245 Commercial St. SE, Suite 210 Salem, Oregon 97301
(503) 364-2002
PN:720001
NGVD29(COS)
NAD83(2011)
OREGON
EXPIRES: 06-30-2026
100901PEREG
ISTERED PROFESSIONALENGINEER
JULY 11, 2023
PAMELA GREENE V ILLA RREA
L
WATERLINE
PLAN & PROFILE
W-02
A ABANDON
C CONNECT EXISTING TO NEW MAIN
COBURN ST S
STA 34+00 TO 38+00
MRN
PGV
AS SHOWN
AS SHOWN
PAO
RESTRAIN ALL JOINTS
CLASS B BACKFILL
NEW 18" DI W
COBURN ST S
RE:
MATCHLINE STA
W-01
34+00
RESTRAIN ALL JOINTS
CLASS B BACKFILL
MIN 36"
OF COVER
NEW 18" DI W
NEW 18" DI W
RE
M
AT
CH
LI
NE
S
TA
W -0
+0
20' PERMANENT
UTILITY EASEMENT
(PUE-1)
STA 35+14.27
18" BUTTERFLY VALVE (FLxMJ)
C1
W-09
10' PERMANENT
UTILITY EASEMENT
(PUE-2)
MIN 36" OF COVER
NEW 8" DI PIPE;
RE: W-06
CONCRETE ASPHALT
GENERAL SHEET NOTES
1. EXISTING UTILITIES ARE SHOWN IN AN
APPROXIMATE LOCATION. CONTRACTOR TO
VERIFY EXISTING UNDERGROUND UTILITIES
PRIOR TO CONSTRUCTION. PLEASE REFER TO
SPECIFICATIONS FOR AVAILABLE POTHOLING
REPORT BY VACX, APRIL 5, 2023.
2. MAINTAIN MINIMUM SEPARATION FROM SANITARY
SEWER LINES PER OAR 333. MAINTAIN MINIMUM
12" VERTICAL SEPARATION FROM ALL OTHER
UTILITIES.
3. IF MINIMUM SEPARATION REQUIREMENTS PER
OAR 333 ARE NOT ACHIEVED, REPLACE ONE
SECTION OF SEWER LATERAL AND /OR SEWER
MAIN WITH PVC PRESSURE PIPE (ASTM D-2241,
SDR-32.5) AND CENTER AT THE CROSSING POINT
PER WITH ONE LENGTH OF DUCTILE IRON
WATERLINE (ALSO CENTERED) PER OAR
333-061-0050. SEWER LATERALS SHALL BE
REPLACED WITH 4" DIAMETER PIPE AND SEWER
MAINS SHALL BE REPLACED WITH 8" DIAMETER
PIPE; RE: CITY OF SALEM STANDARD
CONSTRUCTION SPECIFICATIONS AND SPECIAL
PROVISIONS.
4. RETAIN AND PROTECT ALL UTILITY CROSSINGS
UNLESS NOTED OTHERWISE.
5. CONTRACTOR MAY UTILIZE REDUCED/ALTERNATE
NUMBER OF FITTINGS TO ACHIEVE DESIGNED
ALIGNMENT AND PROFILE, PROVIDE SUGGESTED
CHANGE TO ENGINEER FOR APPROVAL.
STA 35+01.54
18" BUTTERFLY VALVE (FLxMJ)
CITY VIEW CEMETERY
390 HOYT ST S
WILLAMETTE VIEW
APARTMENTS
2332 CRESTVIEW DR S
800 BLK COBURN ST S
888 COBURN ST S
M T
LA
U
R
EL
W
AY
S
2525 COBURN ST S
GRAPHIC SCALE
HORIZ:
VERT:
0 5 10
0 20 40
MIN 18"
26 43
26 43
26 43
13 28
MIN 18"
38+00 39+00 40+00
40+00 41+00 42+00
EXISTING GRADE
@ PIPELINE
EXISTING GRADE
@ PIPELINE
ST
A:
+4
7.
IE
:3
.3
.2 5°
B
EN
D (M
Jx M
J)
EX
W
S
ER
VI
C
E
ST
A:
0+
.6
EX
W
S
ER
VI
C
E
ST
A:
1+
.9
ST
A:
+7
2.
IE
:3
.9
ST
A:
+6
5.
IE
:3
.0
.2 5°
B
EN
D (M
Jx M
J)
SEE ADJACENT SHEET
FOR PIPE LENGTH
AND SLOPE
ST
A:
+5
3.
IE
:3
.6
ST
A:
+0
6.
IE
:3
.2
ST
A:
+2
0.
IE
:3
.2
SEE ADJACENT SHEET
FOR PIPE LENGTH
AND SLOPE
ST
A:
+9
4.
IE
:3
.2
ST
A:
+2
0.
IE
:3
.8
EX
" P
VC
C
AS
IN
G
W / 1
" N G
ST
A:
0+
.3
SEE ADJACENT SHEET
FOR PIPE LENGTH
AND SLOPE
EX 8" SS
STA: 39+34.58
EX 8" SS
STA: 40+35.84
EX 8" SS
STA: 41+53.09
45.6 LF -18"
PIPE @ -4.10%
29.0 LF -18"
PIPE @ -21.14%
7.2 LF -18"
PIPE @ -20.12%
93.56 LF -18"
PIPE @ -18.87%
40.0 LF -18"
PIPE @ -20.15%
47.7 LF -18"
PIPE @ -8.97%
124.81 LF -18"
PIPE @ +14.10%
ST
A:
+1
3.
IE
:3
.6
EX 8" SS
STA: 39+34.58
EX 8" SS
STA: 39+34.58
EX 4" SS
STA. 38+11.04
6''W
6'' W
6''W
6''W
6''W
6''W
6''W
6''W
6''W
6' 'W
6''W
OHP
OHP
OHP
OHP
O
HP
O
HP
EP
X
X
X
X
X
X
X
X
X X
<8''SS
<8''SS<6
''S
S <6
''S S
<6 ''S
S
<8''SS
<8''SS
<8''SS
<8''SS
8''
SS
8''
SS>
8''SS>
<8''SS
<8''SS
<8''SS
<8''SS
<8''SS
<8''SS
<8''SS
<8''SS
<8''SS
<8''SS
<8''SS
<8''SS
SS
UGP
UGP
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
ROW
R O
W
RO
W
R O
W
R O
W
ROW
ROW
ROW
ROW
ROW
BH-5
BH-6
BH-7
<1 0''
SD
<1 0''
SD
<10''SD
<10''SD
<10''SD
<10''SD
<10''SD
<10''SD
<10''SD
<10''SD
<10''SD
1''NG
1''NG
1''
NG
1''
NG
1''
NG
1''
NG
1''NG
1''NG
1''NG
1''NG
1''NG
1''NG
1''N G
1''N G
1''NG
1''NG
1''NG
1''NG
1''NG
1''NG
38+00
39+00
40+00
41+00
42+00
38+50
39+50
40+50
41+50
11.25° BEND (MJxMJ)
STA: 39+22.56
N: 466605.90 E:7540198.08
45° BEND (MJxMJ)
STA: 39+47.40
N: 466581.09 E:7540196.72
45° BEND (MJxMJ)
STA: 40+23.10
N: 466523.61
E:7540245.98 45° BEND (MJxMJ)
STA: 41+94.48
N: 466526.66 E:7540417.17
45° BEND (MJxMJ)
01 CONSTRUCT DUCTILE IRON PIPE CONFORMING
TO AWWA C151, CLASS 52 (SIZE AS SHOWN). ALL
PIPES SHALL BE CEMENT-MORTAR LINED
CONFORMING TO AWWA C104 PER
SPECIFICATIONS. MAINTAIN MINIMUM 36" COVER
FROM FINISH TO GRADE. ALL PIPE JOINTS AND
FITTINGS SHALL BE RESTRAINED AS INDICATED
IN SPECIFICATIONS; RE: SALEM STD PLANS 601
AND 605
02 DEFLECT PIPE VERTICALLY. MAXIMUM
DEFLECTION PER MANUFACTURER'S
RECOMMENDATION
05 BORE, HAND DIG, OR VACUUM EXCAVATE
WITHIN CRITICAL TREE ZONE. SEE DETAILS AND
CITY OF SALEM STANDARD CONSTRUCTION
SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS; RE: EPSC AND TREE
PRESERVATION PLANS
06 DEFLECT PIPE HORIZONTALLY. MAXIMUM
DEFLECTION PER MANUFACTURER'S
RECOMMENDATION
26 POTENTIAL SS SERVICE LINE CONNECTION 8"
SS. NOT LOCATED ON GIS AND/OR SURVEY
31 RETAIN AND PROTECT
33 POTHOLE SERVICE CONNECTION TO CONFIRM
DEPTH. IF WATER SERVICES CONFLICT,
CONTACT CITY FOR FURTHER INSTRUCTION
43 IF REQUIRED, REPLACE SEWER MAIN OR
LATERAL WITH ONE FULL SECTION OF PVC
PRESSURE PIPE (ASTM D-2241, SDR-32.5),
CENTERED AT THE CROSSING POINT PER OAR
333-061-0050; SEE GENERAL SHEET NOTE 3
44 POTHOLED BY VACX, APRIL 5, 2023
48 PLEASE REFER TO SPECIFICATIONS FOR
AVAILABLE SUBSURFACE DATA REPORT BY
GEOENGINEERS, SEPTEMBER 27, 2022
50 CONTRACTOR TO DEFLECT PIPE TO MAINTAIN
10' SEPARATION FROM SANITARY SEWER LINE
J:
\2
SA
LE
M
C O
R \2
8-
C
R
ES
TV
IE
W W
AT
ER
LI
N
E\ C
_D
ES
N
C
AD
\3 _D
ES
IG
N \D
_P
LA
N S-
1\ W
-0
PL
AN
A N
D P
R O
FI
LE
KA
.D W
G
LA
ST
S
AV
ED
: 3 /5
/2
7:
P
M
PR
IN
TE
D : 1
/1 2/
:1
PM
CITY FORCES SHALL
SHEET KEYNOTES
SHEET OF
SHEET TITLE
HORIZ DATUM:
VERT DATUM:
HORIZ SCALE:
VERT SCALE:
DESIGN:
DRAWN:
CHECKED:
APPROVED:
NO. DATE BYDESCRIPTION
REVISIONS
SALEM PUBLIC WORKS DEPART
MENT
NOISIVIDGNIREE
N NIGE
CRESTVIEW
WATERLINE
SHEET PREPARED BY:
245 Commercial St. SE, Suite 210 Salem, Oregon 97301
(503) 364-2002
PN:720001
NGVD29(COS)
NAD83(2011)
OREGON
EXPIRES: 06-30-2026
100901PEREG
ISTERED PROFESSIONALENGINEER
JULY 11, 2023
PAMELA GREENE V ILLA RREA
L
WATERLINE
PLAN & PROFILE
W-03
A ABANDON
C CONNECT EXISTING TO NEW MAIN
COBURN ST S
STA 38+00 TO 42+00
MRN
PGV
AS SHOWN
AS SHOWN
PAO
RESTRAIN ALL JOINTS
CLASS B BACKFILL
NEW 18" DI W
BOLTON TERRACE S
R E:
M
AT
C H
LI
N
E
ST
A
W -0
+0
RESTRAIN ALL JOINTS
CLASS B BACKFILL
NEW 18" DI W
NEW 18" DI W
R E:
M
AT
C H
LI
N
E
ST
A
W -0
+0
0COBURN ST S
NEW 18" DI W
18" MIN
18" MIN
MIN 36" OF
COVER
MIN 36"
OF COVER
MIN 18"
GENERAL SHEET NOTES
1. EXISTING UTILITIES ARE SHOWN IN AN
APPROXIMATE LOCATION. CONTRACTOR TO
VERIFY EXISTING UNDERGROUND UTILITIES
PRIOR TO CONSTRUCTION. PLEASE REFER TO
SPECIFICATIONS FOR AVAILABLE POTHOLING
REPORT BY VACX, APRIL 5, 2023.
2. MAINTAIN MINIMUM SEPARATION FROM SANITARY
SEWER LINES PER OAR 333. MAINTAIN MINIMUM
12" VERTICAL SEPARATION FROM ALL OTHER
UTILITIES.
3. IF MINIMUM SEPARATION REQUIREMENTS PER
OAR 333 ARE NOT ACHIEVED, REPLACE ONE
SECTION OF SEWER LATERAL AND /OR SEWER
MAIN WITH PVC PRESSURE PIPE (ASTM D-2241,
SDR-32.5) AND CENTER AT THE CROSSING POINT
PER WITH ONE LENGTH OF DUCTILE IRON
WATERLINE (ALSO CENTERED) PER OAR
333-061-0050. SEWER LATERALS SHALL BE
REPLACED WITH 4" DIAMETER PIPE AND SEWER
MAINS SHALL BE REPLACED WITH 8" DIAMETER
PIPE; RE: CITY OF SALEM STANDARD
CONSTRUCTION SPECIFICATIONS AND SPECIAL
PROVISIONS.
4. RETAIN AND PROTECT ALL UTILITY CROSSINGS
UNLESS NOTED OTHERWISE.
5. CONTRACTOR MAY UTILIZE REDUCED/ALTERNATE
NUMBER OF FITTINGS TO ACHIEVE DESIGNED
ALIGNMENT AND PROFILE, PROVIDE SUGGESTED
CHANGE TO ENGINEER FOR APPROVAL.
800 BLK COBURN ST S
2519 COBURN ST S
2515 COBURN ST S
2525 COBURN ST S
2530 BOLTON
TERRACE S
2535 ALVARADO
TERRACE S
GRAPHIC SCALE
HORIZ:
VERT:
0 5 10
0 20 40
26 43
14 28
42+00 43+00 44+00 45+00 46+00
EX
N
G
ST
A:
5+
.2
EXISTING GRADE
@ PIPELINE
EX
" W
ST
A:
2+
.2
ST
A:
+8
3.
IE
:3
.4
EX
W
S
ER
VI
C
E
ST
A:
2+
.1
EX
W
S
ER
VI
C
E
ST
A:
3+
.1
EX
W
S
ER
VI
C
E
ST
A:
3+
.1
EX
W
S
ER
VI
C
E
ST
A:
3+
.8
EX
W
S
ER
VI
C
E
ST
A:
5+
.8
EX
" W
ST
A:
5+
.8
ST
A:
+6
4.
IE
:3
.9
ST
A:
+2
7.
IE
:3
.2
° B
EN
D (M
Jx M
J)
ST
A:
+3
1.
IE
:3
.4
° B
EN
D (M
Jx M
J)
EX 10" SD
STA: 42+16.28
EX
N
G
ST
A:
2+
.7
EX
N
G
ST
A:
2+
.5
EX
N
G
ST
A:
4+
.6
EX
N
G
ST
A:
5+
.4
EX
N
G
ST
A:
5+
.9
EX
N
G
ST
A:
3+
.3
EX
N
G
ST
A:
4+
.5
EX
W
S
ER
VI
C
E
ST
A:
5+
.5
EX 8" SS
STA: 42+12.40 319.71 LF -18"
PIPE @ -5.17%
3.9 LF -18"
PIPE @ -107.24%
32.5 LF -18"
PIPE @ -7.75%
33.1 LF -18"
PIPE @ -0.00%
EX
N
G
ST
A:
2+
.7
ROWROWROWROWROWROWROW
ROWROWROWROWROWROWROW
8''W
8''W
8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W 8''W
EP
6' 'W
6''W
6' 'W
EP
<8''SS <8''SS <8''SS <8''SS <8''SS <8''SS <8''SS <8''SS <8''SS <8''SS <8''SS <8''SS <8''SS <8''SS <8''SS <8''SS <8''SS
<8 ''S
S <8
''S S
<8 ''S
S
<6''SS
<6''SS
ROW
ROW
ROW
ROW
ROW
ROW
ROW ROW ROW
ROW ROW ROW
BH-3
BH-4
BH
-5
<1 0'
'S D
SDSD
1''NG
1''NG
1''NG
1''NG 1''NG 1''NG 1''NG 1''NG 1''NG 1''NG 1''NG 1''NG 1''NG 1''NG 1''NG 1''NG 1''NG 1''NG 1''NG 1''NG
NGN
G
N G
N G
N G
1' 'N
G 1'
'N G
+0
43+00 44+00
45+00
46+00
41+50
42+50 43+50 44+50
45+50
STA: 41+94.48
N: 466526.66 E:7540417.17
45° BEND (MJxMJ)
STA: 42+04.48
N: 466519.96 E:7540424.60 45° BEND (MJxMJ)
STA: 45+65.43
N: 466159.15 E:7540419.49 45° BEND (MJxMJ)
STA: 45+83.74
N: 466145.85 E:7540432.08
45° BEND (MJxMJ)
11.25° BEND (MJxMJ)
J:
\2
SA
LE
M
C O
R \2
8-
C
R
ES
TV
IE
W W
AT
ER
LI
N
E\ C
_D
ES
N
C
AD
\3 _D
ES
IG
N \D
_P
LA
N S-
1\ W
-0
PL
AN
A N
D P
R O
FI
LE
KA
.D W
G
LA
ST
S
AV
ED
: 3 /5
/2
7:
P
M
PR
IN
TE
D : 1
/1 2/
:1
PM
CITY FORCES SHALL
SHEET KEYNOTES
SHEET OF
SHEET TITLE
HORIZ DATUM:
VERT DATUM:
HORIZ SCALE:
VERT SCALE:
DESIGN:
DRAWN:
CHECKED:
APPROVED:
NO. DATE BYDESCRIPTION
REVISIONS
SALEM PUBLIC WORKS DEPART
MENT
NOISIVIDGNIREE
N NIGE
CRESTVIEW
WATERLINE
SHEET PREPARED BY:
245 Commercial St. SE, Suite 210 Salem, Oregon 97301
(503) 364-2002
PN:720001
NGVD29(COS)
NAD83(2011)
OREGON
EXPIRES: 06-30-2026
100901PEREG
ISTERED PROFESSIONALENGINEER
JULY 11, 2023
PAMELA GREENE V ILLA RREA
L
WATERLINE
PLAN & PROFILE
W-04
A ABANDON
C CONNECT EXISTING TO NEW MAIN
ALVARADO TERR S
STA 42+00 TO 46+00
MRN
PGV
AS SHOWN
AS SHOWN
PAO
RE:
MATCHLINE STA
W-03
42+00
RESTRAIN ALL JOINTS
CLASS B BACKFILL
NEW 18" DI W
R E:
M
AT
C H
LI
N
E
ST
A W
-0
+0
ALVARADO TERRACE S
NEW 18" DI W
01 CONSTRUCT DUCTILE IRON PIPE CONFORMING
TO AWWA C151, CLASS 52 (SIZE AS SHOWN). ALL
PIPES SHALL BE CEMENT-MORTAR LINED
CONFORMING TO AWWA C104 PER
SPECIFICATIONS. MAINTAIN MINIMUM 36" COVER
FROM FINISH TO GRADE. ALL PIPE JOINTS AND
FITTINGS SHALL BE RESTRAINED AS INDICATED IN
SPECIFICATIONS; RE: SALEM STD PLANS 601 AND
02 DEFLECT PIPE VERTICALLY. MAXIMUM
DEFLECTION PER MANUFACTURER'S
RECOMMENDATION
06 DEFLECT PIPE HORIZONTALLY. MAXIMUM
DEFLECTION PER MANUFACTURER'S
RECOMMENDATION
28 EXISTING 8" WATER LINE TO REMAIN IN SERVICE
DURING CONSTRUCTION
29 1" NATURAL GAS LINE RELOCATED BY UTILITY
OWNER
31 RETAIN AND PROTECT
33 POTHOLE SERVICE CONNECTION TO CONFIRM
DEPTH. IF WATER SERVICES CONFLICT, CONTACT
CITY FOR FURTHER INSTRUCTION
43 IF REQUIRED, REPLACE SEWER MAIN OR LATERAL
WITH ONE FULL SECTION OF PVC PRESSURE PIPE
(ASTM D-2241, SDR-32.5), CENTERED AT THE
CROSSING POINT PER OAR 333-061-0050; SEE
GENERAL SHEET NOTE 3
44 POTHOLED BY VACX, APRIL 5, 2023
48 PLEASE REFER TO SPECIFICATIONS FOR
AVAILABLE SUBSURFACE DATA REPORT BY
GEOENGINEERS, SEPTEMBER 27, 2022
18"
MIN
MIN 36"
OF COVER
28 01
31 31
GENERAL SHEET NOTES
1. EXISTING UTILITIES ARE SHOWN IN AN
APPROXIMATE LOCATION. CONTRACTOR TO
VERIFY EXISTING UNDERGROUND UTILITIES
PRIOR TO CONSTRUCTION. PLEASE REFER TO
SPECIFICATIONS FOR AVAILABLE POTHOLING
REPORT BY VACX, APRIL 5, 2023.
2. MAINTAIN MINIMUM SEPARATION FROM SANITARY
SEWER LINES PER OAR 333. MAINTAIN MINIMUM
12" VERTICAL SEPARATION FROM ALL OTHER
UTILITIES.
3. IF MINIMUM SEPARATION REQUIREMENTS PER
OAR 333 ARE NOT ACHIEVED, REPLACE ONE
SECTION OF SEWER LATERAL AND /OR SEWER
MAIN WITH PVC PRESSURE PIPE (ASTM D-2241,
SDR-32.5) AND CENTER AT THE CROSSING POINT
PER WITH ONE LENGTH OF DUCTILE IRON
WATERLINE (ALSO CENTERED) PER OAR
333-061-0050. SEWER LATERALS SHALL BE
REPLACED WITH 4" DIAMETER PIPE AND SEWER
MAINS…