12b_Amendment0001_70Z0G124BABCDDW05.pdf
PDF 363 KB Posted
- Attached to
- REPAIR AIDS TO NAVIGATION (ATON) SOUTHERN MAINE
- Solicitation number
- 70Z0G124BABCDDW05
About this file
This document is an amendment to a solicitation for structural repair and replacement of five Aids to Navigation assets in Southern Maine. The Contractor shall furnish all labor, materials, equipment, transportation, disposal, supervision, and incidental work to remove existing monopiles and install new monopiles in their place at five locations, following environmental restrictions between May 15 and August 31. The period of performance has been extended to November 16, 2024 to allow for completion after the restriction ends. The solicitation response due date was extended to February 27, 2024. Repairs shall be made to one ATON asset while the other five will be replaced. The U.S. Coast Guard is the contracting agency.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
1. CONTRACT ID CODE
PAGE OF PAGES
1 5
2. AMENDMENT/MODIFICATION NO.
3. EFFECTIVE DATE
02/15/2024
4. REQUISITION/PURCHASE REQ. NO.
5. PROJECT NO. (If applicable)
PSN: 14105107
6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE
Contracting Officer USCG Civil Engineering Unit Providence 475 Kilvert ST STE 100 Warwick, RI 02886
Same as Block 6 Attn: Daniel B. Walker, Contracting Officer
(401) 736-1764
(401) 736-1704 (fax)
8. NAME AND ADDRESS OF CONTRACTOR (NO., STREET, COUNTY, STATE AND ZIP CODE)
THIS AMENDMENT MUST BE ACKNOWLEDGED
See Block 11 below
9A. AMENDMENT OF SOLICITATION NO.
70Z0G124BABCDDW05
9B. DATED (SEE ITEM 11)
01/17/2024
10A. MODIFICATION OF CONTRACT/ORDER NO.
10B. DATED (SEE ITEM 13)
CODE FACILITY CODE
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended, is not extended.
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such Change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE REFERENCED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET
FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (SPECIFY TYPE OF MODIFICATION AND AUTHORITY)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
THE SOLICITATION REFERENCED IN BLOCK #9A IS AMENDED AS FOLLOWS:
01. The due date for receipt of bids is hereby extended to February 27, 2024, AT 2:00 PM LOCAL
TIME, WARWICK, RI.
02. Revise Small Business Size Standard for NAICS 237990 from $39.5 Million to $45.0 Million.
03. In section K, remove FAR 52.225-25 and 52.223-1. These provisions are included in 52.204-8 Annual Reps & Certs.
Continued…
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or Print)
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
DANIEL B. WALKER, Contracting Officer
15B. CONTRACTOR/OFFEROR
(Signature of person authorized to sign)
15C. DATE SIGNED
16B UNITED STATES OF AMERICA
BY
(Signature of Contracting Officer)
16C. DATE SIGNED
NSN 7540-01-152-8070 STANDARD FORM 30 (Rev. 10-83) PREVIOUS EDITION UNUSABLE Prescribed by GSA
FAR (48 CFR) 5
2 5
04. The following are questions submitted during the open period for questions with associated responses:
QUESTION 1: As we discussed, the environmental restriction on sheet G-002 pertaining to no drilling between May 15 and August 31dramatically reduces the allowed work duration.
The current bid/work schedule:
• The current project bid date 2/16/24
• Anticipated NTP +30 days 3/16/24
• Environmental work restriction 5/15/24 – 8/31/24
• Allowed Work duration 171 calendar days 9/03/24
The current bid/work schedule gives the contractor 60 calendar days to get geared up, mobilized, and complete the project between NTP of 3/16/24 and May 15, 2024. Given this timeline, we won’t be able to complete the project on time.
We request that the USCG consider extending the allowed work duration in anticipation that the work won’t take place until after August 31, 2024, once the environmental restriction ends.
ANSWER: Yes. Period of performance will be extended 77 days from 31 August to November 16, 2024, to complete the work.
QUESTION 2: I would like to confirm that all five Aton's are being replaced? Or, is this just for the removal?
ANSWER: Repair 1, Replace 5
QUESTION 3: -The specifications stipulate removal of existing monopiles in their entirety however the plan set Demolition Note 1 States: “REMOVE EXISTING MONO-PILE IN ITS ENTIRETY TO TOP OF BEDROCK.”. Is the contractor expected to remove the entire monopile within the rock, or is the contractor expected to cut the existing monopiles off at the top of bedrock?
ANSWER: Cut existing monopiles at top of bedrock.
QUESTION 4:-Plan Set Demolition Note 2 states: “FOLLOW FEDERAL AND STATE PERMIT REQUIREMENTS FOR PILE REMOVAL.” However no federal or state permits were issued with the bid documents, please provide these for review.
ANSWER: The work is authorized under the Army Corps of Engineers Maine General Permits (General Permit 4 - Aids to Navigation) through self-verification. Although no written authorization is provided by the Corps for Self-Verification Activities, Contractors do need to follow requirements listed in the general conditions, all of which are covered if the best practices noted on the plans and below are followed (also attached).
3 5
QUESTION 5:-Plan sheets S-201B through S-201E depict each existing ATON requiring replacement.
The table on each of these sheets titled “Light List” includes a lat/long position for each ATON. Please clarify whether this describes the current location of the ATON to be removed, or if this is the position where the new ATON is to be installed.
ANSWER: Current Location
QUESTION 6:-Please provide more details regarding the ATON monopiles to be removed. What is their OD? What is the wall thickness? Do the monopiles contain fill of any kind, and to what elevation? What are the ages of each of these monopiles? How are they attached to the rock? Concrete, poured lead, epoxy?
ANSWER: The existing monopiles are tapered as shown in the elevation and ladder connection detail for the bolt on collars. No information on wall thickness or potential fill inside the monopiles.
Drawings note the monopile foundation is steel/iron and the connection to bedrock is unknown.
QUESTION 7:-Are there any environmental restrictions on in-water work aside from Environmental Notes 5 and 6 on drawing G-002?
ANSWER: In addition to the USACE Maine General Conditions, the contractor must install a containment boom and turbidity curtain around the rock socket during drilling activities. Drill the rock sockets inside of a steel casing to contain cuttings and drilling water.
QUESTION 8:-The period for completion is listed as 171 days from NTP. Assuming an award is made 30 days after the bid date, and a notice to proceed is issued 15 days after the award, this would be around April 1. 171 days after this date is September 19. Environmental Note 5 states that osprey nests may not be disturbed prior to September 1 when nests are inactive. This would only leave 19 days to repair and replace both Merriconeag Sound Approach daybeacon and Blacksmithshop Ledge daybeacon, as well as final project cleanup and demobilization. Please clarify the period of performance and time-of-year restrictions affecting the project schedule.
ANSWER: See answer to question 1.
QUESTION 9:-If ospreys are observed to have vacated their nests prior to September 1, would work on these ATONS be permitted upon their departure?
ANSWER: A nest is considered inactive if there are no eggs or young present. An inactive nest can be removed prior to September 1. The September 1 date was given to be conservative.
QUESTION 10:-There is no bid item for mobilization/demobilization on the bid sheet. How should bidders carry these costs in their bid?
ANSWER: Section B, Schedule of prices requires a lump sum price for each aid. Mobilization and demobilization are an element of cost that is included in that pricing.
QUESTION 11:-Section 31 62 16 2.1.4 “Pile Shoes” calls for the requirement of ASTM A27/A27M, Grade 65/35 cast steel cutting shoe. What is the purpose of a cutting shoe for a piling which is being placed within a pre-drilled rock socket?
ANSWER: No need for pile shoes with rock-socketed piles; please disregard.
QUESTION 12:-Section 10 99 02 “Safety Climb System” establishes standards for the system to be installed on the ladder as well as carabiner strength. Please clarify the number of different components, and quantity of each different component of the Safety Climb System the Contractor is expected to provide to the USCG.
ANSWER: Refer to Section 10 99 02, Safety Climb System, 1.3 Performance Requirements.
QUESTION 13:-Is the USCG directing the contractor to install the new monopiles in the exact location of the existing piles requiring removal, or would the new monopiles be installed in the immediate vicinity of the removed piles?
ANSWER: New monopiles are intended to be installed in the immediate vicinity of the existing piles that are to be removed.
-Would the USCG allow for use of an epoxy based grout that meets the same non-shrink and minimum compressive strength requirements contained in Section 31 62 16 2.1.2 Rock Socket Grout?
ANSWER: The USCG may consider a non-shrink epoxy-based grout that meets the minimum compressive strength requirements per the specifications, as well as the ability to be placed underwater and the ability to be extended to fill the 2-inch annular space between the pile and drilled rock socket as shown on the contract drawings. Submit manufacturers documentation demonstrating the proposed product meets these requirements.
QUESTION 14: 1.1 requires job meetings to be held at site locations with the Contracting Officer. Our facility is within 1.5 hrs of each location. Can meetings be held there instead of boat rides and inclement weather issues?
ANSWER: Yes
QUESTION 15: 1.3 requires us to scan areas with electromagnetic or sonic equipment. Can this be waived given the known locations?
ANSWER: No, it will not be waived.
QUESTION 16: 1.6.1 requires preconstruction surveys with the Contracting Officer. We suspect we are to provide transportation. Are there specific requirements we need to adhere to regarding size of boat, ramp to get on and off, and bathroom facilities?
ANSWER: No
QUESTION 17: In regard to reinstalling existing osprey nests. For years we have maintained contracts with the USDA and routinely remove ospreys and nests. We are no longer required to relocate or reinstall inactive nests. Would the Coast Guard consider waiving this requirement?
ANSWER: No, a nest is considered inactive if there are no eggs or young present. An inactive nest can be removed prior to September 1. The September 1 date was given to be conservative.
QUESTION 18: The new structures with platforms and rails will invite further nesting, should we incorporate some anti nesting deterrent in the structure design?
ANSWER: No
4 5
5 5
QUESTION 19: The Coast Guard has routinely directed us to installed new safety climb systems on towers using the 3/8” stainless steel cable system. Will an industry standard cable grab system manufacturer by Tuf-Tug be accepted on these ATONs?
ANSWER: Refer to Section 10 99 02, Safety Climb System, 2.1 Provide a safety climb system made of ASTM A36/A36M structural steel and galvanized per ASTM A123/A123M after fabrication. The system shall be notched every 6 inches and capable of mounting to 1 inch diameter ladder rungs or steel pipe posts.
All other terms and conditions remain unchanged.