This is a Statement of Work for weight test bag assemblies required by the United States Coast Guard Cutter (USCGC) ASPEN. The contractor shall manufacture, assemble, test, and deliver one 77,161-pound main crane test water bag (Canflex P/N CT/CPS-35) and two 11,023-pound low overhead test water bags (Canflex P/N CT/CPS-5LH) to enable biennial weight testing of the vessel's crane and davit systems. The deliverables also include three 90° elbows with male and female camlocks rated for minimum 150 PSI, three 2-inch by 15-foot lay flat hoses with female and male camlock connections rated for minimum 150 PSI, and three 2-inch PVC ball valves with male and female camlocks rated for minimum 150 PSI.

Completed assemblies must be delivered to USCGC ASPEN, Attention: CWO Schlereth, 4688 Homer Spit Road, Homer, Alaska 99603, by October 15, 2026. Acceptance criteria require all camlock fittings to include Type DC dust caps on female couplers and Type DP dust plugs on male adapters. All hose assemblies must be accompanied by a Manufacturer Proof Test Certificate demonstrating hydrostatic testing to 1.5 times working pressure in accordance with ASTM D380, ISO 1402, or equivalent standards. The containment bag system material must meet or exceed minimum parameters to ensure survivability in harsh dockside and offshore environments. No security or confidentiality requirements apply to this contract.

View the file

Other files

File Type Posted
FAR CLAUSES FOR SUPPLY.pdf PDF
SOW ASPEN Weight Bags.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Work Guide

Main crane and low overhead

Weight test bags

1. Purpose and scope Provide USCGC ASPEN with 01 Main crane 77,161lb weight bag (Canflex P/N

CT/CPS-35) and 02 low overhead 11,023lb weight test bags (Canflex P/N CT/CPS-5LH) to enable ship's force to conduct biennial weight tests on Main crane, dual point, and single point davits.

2. Deliverables and Performance Requirements QTY: 01 CRANE TEST WATER BAG Capacity = 35,000 kg (77,161 lb) QTY: 02 CRANE TEST WATER BAG Capacity = 5,000 kg (11,023 lb) QTY: 03 90° elbow with male and female camlock (w/STA-LOK II) with a minimum pressure rating of 150 PSI QTY: 03 2” x 15 ft long lay flat hose with female camlock (w/STA-LOK II) and male camlock connections at opposite ends with a minimum pressure rating of 150 PSI. (Purpose: Fill /oAload hose)

QTY: 03 2” PVC ball valve comes with male and female camlocks (w/STA-LOK II) to connect to 2” fill hose with a minimum pressure rating of 150 PSI

Completed assemblies shall be delivered to: USCGC ASPEN ATTN: CWO Schlereth 4688 Homer Spit Road Homer, AK 99603; Phone Number: 707-683- 9315 Email: Jacob.R.Schlereth@uscg.mil

3. Required Delivery Date 15Oct26

4. Location and Method of Performance Completed assembly will be delivered to the above Homer AK Addres

5. Roles and Responsibilities The Contractor shall manufacture, assemble, test, and deliver the specified weight test bags, hoses, and valve assemblies to the specified delivery location by the Required Delivery Date

6. Acceptance Criteria For the Hoses and couplers, the following standards need to be met:

Camlock Fittings: Every female camlock coupler must be equipped with a matching Type DC (Dust Cap), and every male adapter must have a Type

DP (Dust Plug) to prevent debris entry and protect mating faces when not in use.

Hose Certification: All hose assemblies must be delivered with a Manufacturer Proof Test Certificate proving they were hydrostatically tested to 1.5x working pressure in accordance with ASTM D380, ISO 1402, or an equivalent standard.

For the containment bag system to ensure survivability in harsh dockside and oAshore environments, the material must meet or exceed the following minimum parameters:

For the Hoses and couplers, the following standards need to be met:

Camlock Fittings: Every female camlock coupler must be equipped with a matching Type DC (Dust Cap), and every male adapter must have a Type DP (Dust Plug) to prevent debris entry and protect mating faces when not in use.

Hose Certification: All hose assemblies must be delivered with a Manufacturer Proof Test Certificate proving they were hydrostatically tested to 1.5x working pressure in accordance with ASTM D380, ISO 1402, or an equivalent standard.

For the containment bag system to ensure survivability in harsh dockside and

Ashore environments, the material must meet or exceed the following minimum parameters:

7. Security and Confidentiality