Questions and Answers

Amendment A00003

RFQ Number:70Z08518QP45406

QUESTION #CCSR001

DEFINITE/OPTIONAL ITEM NO. D013 PARA NO. Table 3

TITLE:

WORK ITEM 13: Flex Hose Assemblies, Renew

QUESTION:

The contractor requests that an updated list of hoses to be renewed on the No. 3 SSDG be provided to prospective bidders if the government has such a list available. The current information provided is not sufficient for developing an accurate and competitive bid. At the very least it is recommended that the design pressure for each assembly in tables 3 is provided to limit the potential for large variances between bidders. If this information is not available the contractor requests that Work Item 13 is revised such that the costs of the hoses in table 3 are covered via CFR. The contractor can provide a fixed price to remove, dispose of, and install 41 hydraulic hoses for the number 3 Ship Service Diesel Generator.

RESPONSE:

Refer to drawings 750-WMSL-505-6-1 ASC505006 and Tech Pub 7368B – Ship Service Diesel Engine (SSDG)

– MODEL 3512B – Parts Manual (SEBP4026-22)

QUESTION #CCSR002

DEFINITE/OPTIONAL ITEM NO. D016 PARA NO. Table 3

WORK ITEM 16: Tank Level Indicator (Grey Water Tanks), Install

The contractor requests clarification on the gasket size listed in table 3. The requested Flat Face Seawater Flange is listed as 2” NPS and the requested gaskets are listed as 1-1/2” IPS flange size.

The Contractor shall install new TLI as shown on attached PDF (item 3 at Zone B-63 of DWG NAG-ST-00460)

QUESTION #CCSR003

DEFINITE/OPTIONAL ITEM NO. D004 PARA NO. Table 1

WORK ITEM 4: Sounding Tube (Ballast and Oily Water

Collecting Tanks), Replace

The contractor requests clarification on the pipe diameter for Ballast Tank 5-F-0-W. Table 1 lists the approximate length of sounding tube pipe as 30 feet of 2” pipe. Drawing 750-WMSL-506-004 shows the pipe as being 1-1/2” diameter.

Sounding tube size is 1-1/2.

File details come from the government source that posted it.