Appendix_B_-_Equipment_Enrollment_Form_Spreadsheet.xlsx
XLSX spreadsheet 101 KB Posted
- Solicitation number
- 70Z08318BPCR11100
About this file
Appendix B - Equipment Enrollment Form Spreadsheet
View the file
Other files
Show 40 more
Latest 50 of 68 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Enrollment Form Equipment Enrollment Form For A New USCG Facility
| To be filled out by Government (red colored blocks) | ||||
| Landlord/Unit Name | Landlord OPFAC | SAM Site # | SAM Location/Bldg # | SAM Location Description |
| To be filled out by Contractor (blue colored blocks) | Pre-populated in SAM Based on Uniformat IV # | |||||||
| Equipment Description | Physical Location | Manufacturer | ||||||
| Name | Model # | Serial # | Installation Date | Purchase Price | Replacement Cost | Warranty Expiration Date | Equipment Attributes | |
| (Identification/Name Plate Information) | RS Means Reference # | PM Job Plan(s) w/ Frequency |
(i.e. 1921-M, 1920-Q, 1919-A) Bldg # Floor Room #
| General Instructions: |
| Equipment Description: See Equipment List (Typical) Tab - Column B & D |
| Purchase Price: Total cost of installation to include cost of equipment, labor, shipping, etc… |
| Replacement Cost: Cost of equipment only. |
| Warranty Expiration Date: Typically 1 year from installation date unless a roof. |
| Equipment Attributes: To include sizes (i.e. motor HP, SF, LF, etc…), capacities (other than size), and ratings. |
| RS Means Reference #: See Equipment List (Typical) Tab - Column I - to be filled out by CG Faciilty Engineer |
| PM Job Plan(s) w/ Frequency: See Equipment List (Typical) Tab - Column J - to be filled out by CG Facility Engineer |
Equipment List (Typical)
| Uniformat | ||||||||||
| Level IV | Material/Equipment Category | Level IV Definition | Component Type | UOM | PM | RS Means/Reference Number | RS Means/Reference Description | Existing SAM Job Plan Numbers | Frequency | Design Life |
| A101001 | WALL FOUNDATIONS | Continuous Footings: Assemblies include excavation, hand shaped |
bottom, compacted backfill, formwork and keyway, reinforcing steel, concrete and screed finish.
Foundation Walls: Include work items associated with CIP foundation walls, grade beams, or CMU walls. Assemblies include excavation, compacted backfill, perimeter insulation, perimeter drainage, formwork, reinforcing steel, concrete or
| CMU, and wall finish. | General | LF | N | 100 |
| A101002 | COLUMN FOUNDATIONS AND PILE CAPS | Spread Footings: Individual or part of continuous pier footings. |
Assemblies include excavation, backfill and compaction, formwork, reinforcing steel, and concrete and screed finish. If structural steel columns set directly on spread footings, anchor bolts are included in this assembly.
Pile Caps: Assemblies include excavation if required (normally due to installation of piles, the subgrade is at desired level for pile cap), hand-shaped bottom, compacted backfill, formwork, reinforcing steel, and concrete and screed finish. If structural steel columns set directly on spread footings, anchor bolts are included in this assembly.
Column Piers: Assemblies include formwork, reinforcing steel, concrete or CMU, finish, break ties and patch, and set anchor
| bolts. | General | EA | N | 100 |
| A101003 | DEWATERING | Dewatering is the removal of water from excavations. The two |
principle methods of dewatering are by pump or by a system involving the sinking of a series of well-points around the area and extracting the water by suction pump. Assemblies would include pumps or well points and all associated dewatering
| materials and equipment. | General | SF | N | 100 |
| A101099 | OTHER STANDARD FOUNDATIONS | Standard foundations not described by the assembly categories | ||
| listed above. | General | SF | N | 100 |
| A102001 | PILE FOUNDATIONS | CIP concrete piles, precast concrete piles, steel pipe piles, steel |
H-piles, step-tapered steel piles, and treated wood piles.
Applicable assemblies would include the material for piles, pile
| driving, and pile cut-offs if required. | General | SF | N | 100 |
| A102002 | CAISSONS | Drilled Caissons: Assemblies include drilled caissons, steel |
casings if required, reinforcing steel, bell bottom excavation,
| concrete, and loading and hauling of excavated material. | General | SF | N | 100 |
| A102003 | UNDERPINNING | Underpinning is the provision of permanent support for existing |
buildings by extending their foundations to a new, lower level containing the desired bearing stratum. Assemblies include
| excavation, backfill, and underpinning materials. | General | LF | N | 100 |
| A102004 | DEWATERING | Dewatering is the removal of water from excavations. The two |
principle methods of dewatering are by pump or by a system involving the sinking of a series of well-points around the area and extracting the water by suction pump. Assemblies would include pumps or well points and all associated dewatering
| materials and equipment. | General | SF | N | 100 |
| A102005 | RAFT FOUNDATIONS | Raft foundations or spread foundations consist of a solid slab of |
heavily reinforced concrete covering the entire building footprint
| area. | General | SF | N | 100 |
| A102006 | PRESSURE INJECTED GROUTING | Assemblies provide for injecting cement grout for foundation | ||
| stabilization. | General | SF | N | 100 |
| A102099 | OTHER SPECIAL FOUNDATIONS | These could include cofferdams, soil compaction foundations, |
and other special foundations. Assemblies would include all material and labor necessary to perform the work for the special
| foundation condition. | General | SF | N | 100 |
| A103001 | STANDARD SLAB ON GRADE | Standard slab-on-grade is supported by compacted earth or |
gravel fill. The soil bearing capacity is sufficient to support the slab. Assemblies include fine grade, gravel fill, underslab insulation, edge forms, termite treatment (interior slabs only), vapor retarder, reinforcing, expansion joints, control joints, and
| finish and curing. Assemblies are based on thickness of slab. | General | SF | N | 100 |
| A103002 | STRUCTURAL SLAB ON GRADE | A structural slab-on-grade is not supported by compacted earth |
or gravel fill. The soil bearing capacity is insufficient to support the slab. A structural slab is generally a minimum of eight inches thick and will be reinforced with reinforcing bars rather than welded wire fabric. Assemblies include fine grade, gravel fill, underslab insulation, edge forms, termite treatment, (interior slabs only), vapor retarder, reinforcing, expansion joints, control joints, and finish and curing. Assemblies are based on thickness
| of slab. | General | SF | N | 100 |
| A103003 | INCLINED SLAB ON GRADE | An inclined slab-on-grade is a slab that is poured on an incline. |
An example would be an inclined loading dock slab and associated ramps. Assemblies include fine grade, gravel fill, underslab insulation, edge forms, termite treatment (interior slabs only), vapor retarder, reinforcing, expansion joints, control joints, and finish and curing. Assemblies are based on thickness
| of slab. | General | SF | N | 100 |
| A103004 | TRENCHES | Cast-in-place trenches. Assemblies include excavation, hand shaped |
bottoms, compacted backfill, formwork, reinforcing steel, concrete, and concrete finish. Examples include trench drains
| and dust trenches. | General | LF | N | 100 |
| A103005 | PITS AND BASES | Cast-in-place pits and bases. Assemblies include excavation, |
hand-shaped bottoms, compacted backfill, formwork, reinforcing steel, concrete, and concrete finish. Examples include elevator
| pits, dock leveler pits, oil change pits, and bases for equipment. | General | EA | N | 100 |
| A103006 | FOUNDATION DRAINAGE | Foundation drainage directly associated with draining the |
foundation. This category does not include storm drainage piping for site. It would include drain pipe or drain tile at foundation or basement for specific purposes of draining foundation or basement. Assemblies would include excavation, hand-shaped bottoms, gravel, compacted backfill, and drain pipe, including
| accessories. | General | LF | N | 100 |
| A103099 | OTHER SLAB ON GRADE | Slab-on-grade not described by the assembly categories listed | ||
| above. | General | SF | N | 100 |
| A201001 | EXCAVATION FOR BASEMENTS | All excavation, stockpiling, and hauling associated with | ||
| basement excavations are included in this assembly. | General | CY | N | NA |
| A201002 | STRUCTURE BACKFILL AND COMPACTION | All backfill including hauling in of suitable soils and all necessary | ||
| compaction is included in this assembly. | General | CY | N | 100 |
| A201003 | SHORING | This type of shoring is to resist horizontal pressure and not |
intended to carry vertical loads. Assemblies would include sheet piling or other material and labor used to hold back earth around
| the perimeter of an excavation. | General | SF | N | 100 |
| A201099 | OTHER BASEMENT EXCAVATION | Basement excavation not described by the assembly categories | ||
| listed above. | General | CY | N | 100 |
| A202001 | BASEMENT WALL CONSTRUCTION | This includes work items associated with CIP foundation walls or |
CMU walls and penetrations. Assemblies include formwork,
| reinforcing steel, concrete or CMU, and wall finish and curing. | General | SF | N | 100 |
| A202002 | MOISTURE PROTECTION | This assembly would be based on the type and square footage | ||
| of waterproofing used on the foundation wall. | General | SF | N | 100 |
| A202003 | BASEMENT WALL INSULATION | This assembly would be based on the type and square footage | ||
| of insulation used on the foundation wall. | General | SF | N | 100 |
| A202099 | OTHER BASEMENT WALLS | Basement walls not described by the assembly categories listed | ||
| above. | General | SF | N | 100 |
| B101001 | STRUCTURAL FRAME | The structural frame could consist of structural steel including |
columns, beams, joists, and all associated items. It could be a concrete frame utilizing concrete or masonry columns and concrete girders and beams. The structural frame could be wood columns with wood beams or wood trusses. The structural frame could be a combination of the above. For example, concrete or masonry columns with structural steel beams and joists. All associated work items should be included in each assembly.
Separate assemblies would be used for different types of construction. The unit of measure at the assembly level is the square footage of the supported area. Decks and slabs are not
| included in this assembly. | General | SF | N | 100 |
| B101002 | STRUCTURAL INTERIOR WALLS | Assemblies would be CIP or CMU walls or other structural |
interior walls. The assemblies would include the labor and material required to perform the construction tasks associated
| with this type of wall. | General | SF | N | 100 |
| B101003 | FLOOR DECKS AND SLABS | Slabs above grade should be broken into assemblies according |
to their particular type of construction (that is, flat slab, pan slab, precast or pre-stressed slab, four-way slab, slabs on metal or wood decking with concrete fill, etc.). All associated work items should be included in each assembly, such as expansion and
| contraction joints. | General | SF | N | 100 |
| B101004 | BALCONY CONSTRUCTION | Balconies above grade should be broken into assemblies |
according to their particular type of construction. All associated
| items including handrails should be included in the assembly. | General | SF | N | 100 |
| B101005 | RAMPS | Ramps above grade should be broken into assemblies according |
to their type of construction. All associated items including
| handrails should be included in the assembly. | General | SF | N | 80 |
| B101006 | FLOOR RACEWAY SYSTEMS | Under floor or in-slab conduit including conduit and all | ||
| associated devices. | General | SF | N | 40 |
| B101007 | INCLINED AND STEPPED FLOORS | This assembly should be broken down according to their |
particular type of construction (that is, flat slab, pan slab, precast or pre-stressed slab, four-way slab, slabs on metal or wood decking with concrete fill, etc.). All associated work items should be included in each assembly, such as expansion and
| contraction joints. | General | SF | N | 40 |
| B101099 | OTHER FLOOR CONSTRUCTION | Any type of special floor construction not included above would |
fall in this category, such as catwalks, space frames, etc. All
| associated work items would be included in the assembly. | General | SF | N | 100 |
| B102001 | STRUCTURAL FRAME | The structural frame could consist of structural steel including |
columns, beams, joists, and all associated items. It could be a concrete frame utilizing concrete or masonry columns and concrete girders and beams. The structural frame could be wood columns with wood beams or wood trusses. The structural frame could be a combination of the above. For example, concrete or masonry columns with structural steel beams and joists. All associated work items should be included in each assembly.
Separate assemblies would be used for different types of construction. The unit of measure at the assembly level is the square footage of the supported area. Decks and slabs are not
| included in this assembly. | General | SF | N | 100 |
| B102002 | STRUCTURAL INTERIOR WALLS | Assemblies would be CIP or CMU walls or other structural |
interior walls. The assemblies would include the labor and material required to perform the construction tasks associated
| with this type of wall. | General | SF | N | 100 |
| B102003 | ROOF DECKS AND SLABS | Roof decks and slabs should be broken into assemblies |
according to their particular type of construction (that is, flat slab, pan slab, precast or pre-stressed slab, four-way slab, slabs on metal or wood decking with concrete fill, etc.). All associated
| work items should be included in each assembly. | General | SF | N | 85 |
| B102004 | CANOPIES | Canopies should be broken into assemblies according to their |
particular type of construction (that is, flat slab, pan slab, precast or pre-stressed slab, four-way slab, slabs on metal or wood decking with concrete fill, etc.). All associated work items should
| be included in each assembly. | General | SF | N | 30 |
| B102099 | OTHER ROOF CONSTRUCTION | Any type of special roof construction not included above would |
fall into this category. All associated work items would be
| included in this assembly. | General | SF | N | 40 |
| B201001 | EXTERIOR CLOSURE | Assemblies would include material contained in exterior closure |
wall, such as masonry with brick veneer. Materials used for interior finishes on exterior walls are not included in this assembly. For example, if the interior side of this masonry wall is sheetrock applied on metal furring strips, the masonry wall is included in this assembly, but the furring strips and sheetrock
| are categorized as System C3010, Wall Finishes. | General | SF | N | 55 |
| B201002 | EXTERIOR WALL BACKUP CONSTRUCTION | Assemblies include the support structure for the exterior skin or |
provide load bearing walls for the facility, or both. Materials used for interior finishes on exterior walls are not included in this assembly. For example, if the interior side of the masonry wall is sheetrock applied on metal furring strips, the masonry wall is included in this assembly, but the furring strips and sheetrock
| are categorized as System C3010, Wall Finishes. | General | SF | N | 40 |
| B201003 | INSULATION AND VAPOR RETARDER | Assemblies would include all types of insulation associated with |
the exterior wall. Rigid, batt, and poured insulation should be
| separated into different assemblies. | General | SF | N | 50 |
| B201004 | PARAPETS | Assemblies include materials used in association with parapets. |
Parapets are long walls or railings usually along the edge of a
| roof or balcony. | General | LF | N | 40 |
| B201005 | EXTERIOR LOUVERS AND SCREENS | Assemblies include louvers and screens which are located in |
exterior walls. The unit of measure at the assembly level is
| each. | Exterior Louver, Operable | SF | N | 30 |
| B201006 | SUN CONTROL DEVICES (EXTERIOR) | Assemblies include awnings, shades, and solar panels attached |
to the exterior of the building. A separate assembly should be
| used for each type of sun control device. | General | SF | N | 20 |
| B201007 | BALCONY WALLS AND RAILINGS | Assemblies would include materials associated with balcony |
walls and handrails. These rails are usually guardrails and not
| associated with stairs. | General | LF | N | 45 |
| B201008 | EXTERIOR SOFFITS | Assemblies would include all associated materials which make |
up the soffit and supports for the soffit. Typical materials would
| include wood, aluminum, exterior grade gypboard, stucco, etc. | General | SF | N | 30 |
| B201009 | SCREEN WALL | Exterior screen walls used for security purposes immediately |
adjacent to the building such as screen walls at a loading dock.
Assemblies would include materials associated with all types of walls. Note that perimeter fencing that is typically more than five feet from the building's exterior is included in sitework rather
| than in this system. | General | LF | N | 40 | ||||
| B201010 | EXTERIOR COATINGS | Assemblies include paint, stucco, etc. The unit of measure at the | ||||||
| assembly level is area of exterior coatings. | General | SF | N | 25 | ||||
| B201011 | JOINT SEALANT | Exterior application of joint sealants | General | LF | N | 20 | ||
| B201099 | OTHER EXTERIOR WALLS | Exterior walls not described by the assembly categories listed | ||||||
| above. | General | SF | N | NA | ||||
| B202001 | WINDOWS | Fixed or operable windows located in exterior walls or exterior |
skin. Assemblies would include frames, glazing, caulking,
| finishes, and other associated work. | General | SF | N | 55 |
| B202002 | STOREFRONTS | Fixed storefronts including associated doors in exterior walls or |
exterior skin. Assemblies would include frames, glazing,
| caulking, finishes, and other associated work. | General | SF | N | 30 |
| B202003 | CURTAIN WALLS | This applies to glass curtain walls and spandrel glass in exterior |
walls or exterior skin. Assemblies would include frames, glazing,
| caulking, finishes, and other associated work. | General | SF | N | 50 | ||||
| B202004 | EXTERIOR GLAZING | This includes acrylic, polycarbonate, and plastic glazing. | General | SF | N | 20 | ||
| B202099 | OTHER EXTERIOR WINDOWS | Exterior windows not described by the assembly categories | ||||||
| listed above. | General | SF | N | 60 | ||||
| B203001 | SOLID DOORS | Assemblies include all exterior solid doors, hollow metal or wood |
with frames. Solid doors may include viewing lites in door. Door
| hardware is located in B203008, Exterior Door Hardware. | General | EA | N | 35 |
| B203002 | GLAZED DOORS | Assemblies include all glazed exterior doors with glass, frames |
(not included in storefront and curtain walls). These doors can be made of storefront materials, but are not part of a storefront.
| Door hardware is located in B203008, Exterior Door Hardware. | General | EA | N | 30 | |||||||
| B203003 | REVOLVING DOORS | Assemblies include all revolving doors at exterior of the facility. | Revolving Door, Manual | EA | Y | B20353001950 | Door, Revolving, Manual | 1723-S | S | 30 | |
| B203003 | REVOLVING DOORS | Assemblies include all revolving doors at exterior of the facility. | Revolving Door, Electric | EA | Y | B20353002950 | Door, Revolving, Electric | 1727-S | S | 30 | |
| B203004 | OVERHEAD AND ROLL-UP DOORS | Overhead and roll-up doors installed in exterior walls or exterior |
skin. Assemblies include frames, hardware, hoisting devices, and finish and other associated work. The unit of measure at the
| assembly level is each door. | Overhead Rollup Door, Manual, up to 24'H x 25'W | SF | Y | B20354001950 | Door, overhead, manual, up to 24'H x 25'W | 1655-S | S | 30 |
| B203004 | OVERHEAD AND ROLL-UP DOORS | Overhead and roll-up doors installed in exterior walls or exterior |
skin. Assemblies include frames, hardware, hoisting devices, and finish and other associated work. The unit of measure at the
| assembly level is each door. | Overhead Rollup Door, Electric, up to 24'H x 25'W | SF | Y | B20354101950 | Door, overhead, roll-up, electric, up to 24'H x 25'W | 1656-S | S | 30 |
| B203004 | OVERHEAD AND ROLL-UP DOORS | Overhead and roll-up doors installed in exterior walls or exterior |
skin. Assemblies include frames, hardware, hoisting devices, and finish and other associated work. The unit of measure at the
| assembly level is each door. | Overhead Rollup Door, Shutter, Electric | SF | Y | B20354501950 | Shutter, roll-up, electric | 1733-A | A | 30 |
| B203005 | HANGAR DOORS | Large aircraft doors used on medium and high bay hangars. |
Assemblies would include frames, hardware, hoisting devices,
| and finish and other associated work. | Hangar Door, Sliding | SF | Y | B20351102950 | Door, sliding | 1721-Q 1716-A | Q/A | 40 |
| B203006 | BLAST RESISTANT DOORS | Special exterior doors used for blast resistance. Assemblies |
would include frames, hardware, hoisting devices, and finish and
| other associated work. | Blast Resistant Door, Hurricane Shutters | SF | Y | N/A | Hurricane Shutters/Blast resistant door | 5042-A | A | 30 |
| B203007 | GATES | Any special gate type used in the exterior wall or exterior skin of |
the building. Assemblies would include frames, hardware, hoisting devices, and finish and other associated work. The unit
| of measure at the assembly level is each gate. | General | SF | N | 20 |
| B203008 | EXTERIOR DOOR HARDWARE | Exterior door hardware includes items such as closers, hinges, | ||
| locksets, panic hardware, etc. | General | EA | N | 20 |
| B203098 | OTHER EXTERIOR SPECIALTY DOORS | Any special type door used in the exterior wall or exterior skin of |
the building. Assemblies would include frames, hardware, hoisting devices, and finish and other associated work. The unit measure at the assembly level is each door, or area of special
| doors, that is, hangar doors. | General | EA | N | 30 | ||||
| B203099 | OTHER EXTERIOR PERSONNEL DOORS | Exterior personnel doors not described by the assembly | ||||||
| categories listed above. | General | EA | N | 30 | ||||
| B301001 | HIGH SLOPE ROOF COVERINGS | Assemblies include roof coverings, such as shingle, wood shake, | ||||||
| and standing seam, etc. | Roof, High Sloped | SF | Y | N/A | Roof | 6440-A | A | 30 |
| B301002 | LOW SLOPE MEMBRANE SYSTEMS | Assemblies include roof coverings, such as built-up, elastomeric, |
modified bitumen, etc. Also, walkways or work areas (used to
| gain access to rooftop equipment) will be included here. | Roof, Low Sloped | SF | Y | N/A | Roof | 9068-A | A | 20 | |||
| B301003 | ROOF INSULATION AND FILL | Assemblies include all types of insulation associated with the | |||||||||
| roof area. | General | SF | N | 20 | |||||||
| B301004 | FLASHINGS AND TRIM | Assemblies include all flashings associated with the roof, that is, | |||||||||
| eave flashing, gable flashing, etc. | General | SF | N | 25 | |||||||
| B301005 | GUTTERS AND DOWNSPOUTS | Assemblies include all gutters, downspouts, and associated work | |||||||||
| including splash blocks. | General | LF | N | 25 | |||||||
| B301006 | ROOF OPENINGS AND SUPPORTS | All roof penetrations including roof hatches, sky lights, area | |||||||||
| glazing, roof hatches, gravity roof ventilators, smoke vents, etc. | General | SF | N | 45 | |||||||
| B301099 | OTHER ROOFING | Roofing not described by the assembly categories listed above. | Roof | SF | Y | NA | Roof | 9069-A | A | 30 | |
| C101001 | FIXED PARTITIONS | Interior fixed partitions include metal or wood studs, sheetrock, | |||||||||
| masonry, and concrete walls. | General | SF | N | 60 | |||||||
| C101002 | DEMOUNTABLE PARTITIONS | Assemblies would include all demountable partitions and | |||||||||
| associated work including tracks and anchoring systems. | General | SF | N | 20 | |||||||
| C101003 | RETRACTABLE PARTITIONS | Assemblies would include all retractable or folding partitions and | |||||||||
| associated work including tracks and anchoring systems. | General | SF | N | 20 | |||||||
| C101004 | INTERIOR GUARDRAILS AND SCREENS | Assemblies include balustrades (handrails and the row screen of |
posts that support them) and screens and associated work including tracks and anchoring systems. These balustrades/ guardrails are related to interior balconies and are not
| associated with stairs. | General | LF | N | 20 |
| C101005 | INTERIOR WINDOWS | Fixed or operable windows. Assemblies would include frames, | ||
| glazing, caulking and other associated work. | General | SF | N | 40 |
| C101006 | GLAZED PARTITIONS AND STOREFRONTS | Fixed interior glazed partitions including interior storefronts with |
doors. Assemblies include frames, glazing, caulking, and other
| associated work. | General | SF | N | 30 | ||||
| C101007 | INTERIOR GLAZING | Interior glazing. | General | SF | N | 30 | ||
| C101008 | JOINT SEALANT | Interior joint sealant. | General | LF | N | 20 | ||
| C101099 | OTHER PARTITIONS | Interior partitions not described by the assembly categories listed | ||||||
| above. | General | SF | N | NA | ||||
| C102001 | STANDARD INTERIOR DOORS | Assemblies include all standard interior wood or hollow metal |
doors with frames, finish, etc. Standard interior doors may include vision lites. Interior door hardware is located in C102007,
| Interior Door Hardware. | General | LEF | N | 40 |
| C102002 | GLAZED INTERIOR DOORS | Assemblies include all glazed interior doors with glass, frames, |
finish, etc. Interior door hardware is located in C102007, Interior
| Door Hardware. | General | LEF | N | 30 |
| C102003 | FIRE DOORS | Assemblies include all interior fire doors, including all necessary |
frames, and sensing devices integral with doors. Interior door
| hardware is located in C102007, Interior Door Hardware. | Fire Door, Swinging | LEF | Y | C10251101950 | Fire Door, swinging | 1738-Q | Q | 30 |
| C102003 | FIRE DOORS | Assemblies include all interior fire doors, including all necessary |
frames, and sensing devices integral with doors. Interior door
| hardware is located in C102007, Interior Door Hardware. | Fire Door, Sliding | LEF | Y | C10251102950 | Fire Door, sliding | 1743-Q | Q | 30 |
| C102003 | FIRE DOORS | Assemblies include all interior fire doors, including all necessary |
frames, and sensing devices integral with doors. Interior door
| hardware is located in C102007, Interior Door Hardware. | Fire Door, Roll-up | LEF | Y | C10251103950 | Fire Door, roll-up | 1750-Q 1746-A | Q/A | 30 |
| C102004 | SLIDING AND FOLDING DOORS | Assemblies include all sliding and folding doors with frames, |
hardware, locking devices, tracks, and supporting systems. The
| unit of measure at the assembly level is each. | General | SF | N | 30 |
| C102005 | INTERIOR OVERHEAD DOORS | Overhead doors installed in the interior of a facility. Assemblies |
include frames, hardware, hoisting devices, and finish and other associated work. The unit of measure at the assembly level is
| each door. | Door, overhead, roll-up, electric, up to 24'H x 25'W | SF | Y | B20354101950 | Door, overhead, roll-up, electric, up to 24'H x 25'W | 1656-S | S | 30 |
| C102005 | INTERIOR OVERHEAD DOORS | Overhead doors installed in the interior of a facility. Assemblies |
include frames, hardware, hoisting devices, and finish and other associated work. The unit of measure at the assembly level is
| each door. | Interior Overhead Door, Roll-up, Manual up to 24'H x 25'W | SF | Y | B20354001950 | Door, overhead, manual, up to 24'H x 25'W | 1655-S | S | 30 |
| C102006 | INTERIOR GATES | Any special type gate installed in the interior of a facility. |
Assemblies include frames, hardware, hoisting devices, and finish and other associated work. The unit measure at the
| assembly level is each gate. | General | SF | N | 25 |
| C102007 | INTERIOR DOOR HARDWARE | Interior door hardware includes items such as closers, hinges, | ||
| locksets, panic hardware, etc. | General | EA | N | 20 |
| C102098 | OTHER INTERIOR SPECIALTY DOORS | Any special type door installed in the interior of a facility. |
Assemblies include frames, hardware, hoisting devices, and finish and other associated work. The unit measure at the
| assembly level is each gate. | General | LEF | N | 25 |
| C102099 | OTHER INTERIOR PERSONNEL DOORS | Interior personnel doors not described by the assembly | ||
| categories listed above. | General | LEF | N | 40 |
| C103001 | COMPARTMENTS, CUBICLES AND TOILET PARTITIONS |
Assemblies include individual compartments, cubicles, toilet
| partitions, and urinal screens. | General | EA | N | 20 | ||||
| C103002 | TOILET AND BATH ACCESSORIES | Toilet and bath accessories. For example, soap dispensers, toilet | ||||||
| paper holder, towel dispensers, grab bars, bathroom mirrors, etc. | General | EA | N | 20 | ||||
| C103003 | MARKER BOARDS AND TACK BOARDS | Assemblies include all marker boards, tackboards, and fastening | ||||||
| devices. The unit of measure at the assembly level is each. | General | SF | N | 20 | ||||
| C103004 | IDENTIFYING DEVICES | Assemblies include all signs, plaques, traffic markers, etc. | General | EA | N | 20 | ||
| C103005 | LOCKERS | Assemblies include all types of lockers, either wood or metal, |
single or double tier. Special bases used for lockers would be
| included in this assembly. | General | EA | N | 25 |
| C103006 | SHELVING | Assemblies include all types of shelving with brackets and all | ||
| supporting materials and finish, if required. | General | LF | N | 45 |
| C103007 | FIRE EXTINGUISHER CABINETS | This assembly would include all types and sizes of fire |
extinguisher cabinets. Fire extinguishers are not included in this assembly; they are included in Section D4030, Fire Protection
| Specialties. | General | EA | N | 20 |
| C103008 | COUNTERS | Assemblies include all counters and countertops with all |
necessary brackets and supporting materials and finish, if
| required. | General | LF | N | 40 |
| C103009 | CABINETS | This assembly includes all cabinetry and millwork items with |
associated accessories and anchoring devices. Cabinet finishes are included in this assembly. Metal cabinets should be a
| separate assembly from wood cabinets or millwork. | General | LF | N | 30 |
| C103010 | CLOSETS | This assembly includes all built-in closets with all associated |
work and finishes. These closets are millwork items or
| prefabricated coat closets for schools and dormitories. | General | LF | N | 25 | ||||
| C103011 | FIRESTOPPING PENETRATIONS | Assembly includes sleeve, caulking, and flashing. | General | EA | N | 50 | ||
| C103012 | SPRAYED FIRE-RESISTIVE MATERIALS | Sprayed Fire-Resistive Materials includes materials that are |
applied primarily to a building's framework (columns, beams,
| bracing, metal decking) to prevent structural failure. | General | SF | N | 50 |
| C103013 | RAISED ACCESS FLOORING | Assemblies include all types of raised flooring, pedestal access | ||
| floors and other types of access flooring. | General | SF | N | 25 |
| C103014 | CASEWORK | Assemblies would include built-in pre-manufactured cabinetry for |
specialized functions such as laboratories, libraries, medical, and
| dental facilities. | General | EA | N | 30 |
| C103099 | OTHER INTERIOR SPECIALTIES | Interior specialties not described by the assembly categories | ||
| listed above. | General | SF | N | 20 |
| C201001 | INTERIOR STAIR CONSTRUCTION | Assemblies include interior stairs. Handrails, finishes, and all | ||
| associated work items are included in this assembly. | General | FLT | N | 80 |
| C201002 | EXTERIOR STAIR CONSTRUCTION | Assemblies include exterior stairs which are in unheated spaces |
and exposed to the weather. Handrails, finishes, and all
| associated work items are included in the assembly. | General | VLF | N | 65 |
| C201099 | OTHER STAIR CONSTRUCTION | Stair construction not described by the assembly categories | ||
| listed above. | General | FLT | N | 30 |
| C202001 | INTERIOR STAIR FINISH | Includes finishes to treads, risers, landings, and soffits, and | ||
| finishes to handrails and guardrails. | General | SF | N | 25 |
| C301001 | CONCRETE WALL FINISHES | This assembly would include a concrete finish applied directly to |
an interior wall surface. This assembly does not include items that directly apply to wall finishes covered elsewhere in this
| subsystem. | General | SF | N | 40 |
| C301002 | PLASTER WALL FINISHES | This assembly includes plaster or stucco applied directly to an |
interior wall surface. Lath and associated work would be included in this assembly. This assembly does not include items that directly apply to wall finishes covered elsewhere in this
| subsystem. | General | SF | N | 40 |
| C301003 | GYPSUM WALLBOARD FINISHES | This assembly includes gypsum wallboard applied directly to an |
interior wall surface. Furring strips or channels are included in this assembly. This assembly also includes taping, sanding, finishing, and sheetrock accessories. This assembly does not include items that directly apply to wall finishes covered
| elsewhere in this subsystem. | General | SF | N | 40 |
| C301004 | TILE AND TERRAZZO WALL FINISHES | This assembly includes tile and terrazzo applied directly to an |
interior wall surface. Each type of tile would be a separate
| assembly. | General | SF | N | 75 |
| C301005 | PAINTING TO WALLS | This assembly includes painting, spackling and sealant applied | ||
| directly to an interior wall surface. | General | SF | N | 10 |
| C301006 | WALL COVERINGS | This assembly includes wall coverings and protective strips | ||
| applied directly to an interior wall surface. | General | SF | N | 15 |
| C301007 | ACOUSTICAL PANELS ADHERED TO WALLS | This assembly includes acoustical tiles and panels with | ||
| associated work applied directly to an interior wall surface. | General | SF | N | 40 |
| C301008 | SPECIAL COATINGS TO WALLS | Assemblies include any special coatings not included in |
assembly Categories C301001 through C301007, which are
| applied to interior wall surfaces. | General | SF | N | 20 |
| C301099 | OTHER WALL FINISHES | Assemblies include finishes to wall types not included above. |
These include, but are not limited to, different types of shielding
| and the work and materials associated with each. | General | SF | N | 20 | ||||
| C302001 | TILE FLOOR FINISHES | Assemblies include ceramic, quarry, and other non-resilient tile | ||||||
| floors. | General | SF | N | 20 | ||||
| C302002 | TERRAZZO FLOOR FINISHES | Assemblies include terrazzo floors. | General | SF | N | 50 | ||
| C302003 | WOOD FLOORING | Assemblies include wood floors. | General | SF | N | 40 | ||
| C302004 | RESILIENT FLOOR FINISHES | Assemblies include resilient floors. | General | SF | N | 35 | ||
| C302005 | CARPETING | Carpeting. | General | SF | N | 7 | ||
| C302006 | MASONRY AND STONE FLOORING | Assemblies include masonry and stone flooring. | General | SF | N | 50 | ||
| C302007 | PAINTING AND STAINING FLOORS | Assemblies include painted and stained floor surfaces. | General | SF | N | 10 | ||
| C302008 | WALL BASE FINISHES | Assemblies include wall base, consisting of various materials | ||||||
| such as vinyl, ceramic tile, etc. | General | LF | N | 25 | ||||
| C302009 | FLOOR TOPPINGS AND TRAFFIC MEMBRANES | Floor toppings and traffic membranes. | General | SF | N | 20 | ||
| C302010 | HARDENERS AND SEALERS | Hardeners and sealers. | General | SF | N | 20 | ||
| C302099 | OTHER FLOORING AND FLOOR FINISHES | Assemblies include floor finishes not described by the assembly | ||||||
| categories listed above, such as conductive, armored, etc. | General | SF | N | 20 | ||||
| C303001 | EXPOSED CONCRETE FINISHES | Assemblies include concrete finishes applied to interior ceilings. |
This assembly does not include items that directly apply to
| ceiling finishes covered elsewhere in this subsystem. | General | SF | N | 30 |
| C303002 | PLASTER CEILING FINISHES | Assemblies include plaster or stucco finishes applied to interior |
ceilings. Lath and associated work would apply to this assembly.
This assembly does not include items that directly apply to
| ceiling finishes covered elsewhere in this subsystem. | General | SF | N | 60 |
| C303003 | GYPSUM WALLBOARD CEILING FINISHES | Assemblies include gypsum wallboard applied to interior ceilings. |
Furring strips or channels are included in this assembly if they are applied directly to the ceiling surface. If the gypsum board is applied to a suspended ceiling system, the suspended system would be in Assembly Category C303007. This assembly does not include items that directly apply to ceiling finishes covered
| elsewhere in this subsystem. | General | SF | N | 40 |
| C303004 | ACOUSTICAL CEILING TILES AND PANELS | Assemblies include acoustical ceiling tiles and panels. The | ||
| suspension system, if required, is in Assembly Category | General | SF | N | 20 |
| C303005 | WOOD CEILINGS | Assemblies include wood ceilings. Different types of wood |
ceilings should be separated into different assemblies. If the wood ceiling is applied to a suspended ceiling system, the suspended system would be in Assembly Category C303007.
This assembly does not include items that directly apply to
| ceiling finishes covered elsewhere in this subsystem. | General | SF | N | 50 |
| C303006 | PAINTING AND STAINING CEILINGS | Assemblies include painted and stained finished interior ceiling | ||
| surfaces. | General | SF | N | 10 |
| C303007 | SUSPENSION SYSTEMS | This assembly includes any suspension system which is |
suspended or hung from the structure for the purpose of
| fastening a ceiling. | General | SF | N | 40 | ||||
| C303008 | METAL STRIP CEILINGS | Assemblies include all metal strip materials applied to ceilings. | General | SF | N | 25 | ||
| C303099 | OTHER CEILING AND CEILING FINISHES | Special ceilings and ceiling finishes not described by the | ||||||
| assembly categories listed above. | General | SF | N | 40 | ||||
| D101001 | GENERAL CONSTRUCTION ITEMS | Includes construction work, other than conveying system work, |
which must be performed in conjunction with this type of work to
| complete the system. | General | EA | N | 20 | |||||||
| D101002 | PASSENGER ELEVATORS | The unit measure at the assembly level is each stop. | Hydraulic Elevators - 1500 lb, 2 floors | STP | CERT | D10151101950 | Elevator, hydraulic, passenger | 1768-M 1760-Q 1646-A | M/Q/A | 40 | |
| D101002 | PASSENGER ELEVATORS | The unit measure at the assembly level is each stop. | Passenger Elevator, Electric, Cable | STP | Y | D10151001950 | Elevator, cable, electric, passenger | 1836-M 1829-Q 1792-A | M/Q/A | 40 | |
| D101002 | PASSENGER ELEVATORS | The unit measure at the assembly level is each stop. | Elevator, hydraulic & cable electric passenger -certifications | STP | Y | N/A | Elevator, hydraulic & cable electric passenger -certifications | 5433-A | A | 40 | |
| D101003 | FREIGHT ELEVATORS | The unit measure at the assembly level is each stop. | Freight Elevator, Hydraulic | STP | CERT | D10151101950 | Elevator, hydraulic, freight | 1768-M 1760-Q 1646-A | M/Q/A | 40 | |
| D101003 | FREIGHT ELEVATORS | The unit measure at the assembly level is each stop. | Freight Elevator, Electric/Cable | STP | Y | D10151001950 | Elevator, cable, electric, freight | 1836-M 1829-Q 1792-A | M/Q/A | 40 | |
| D101003 | FREIGHT ELEVATORS | The unit measure at the assembly level is each stop. | Elevator, hydraulic & cable electric freight - certifications | STP | Y | N/A | Elevator, hydraulic & cable electric freight - certifications | 5433-A | A | 40 | |
| D101004 | WHEELCHAIR LIFT | Pre-manufactured lift to gain wheelchair access. | Wheelchair lift | STP | CERT | D10153101950 | Wheelchair lift | 1846-S | S | 15 | |
| D101004 | WHEELCHAIR LIFT | Pre-manufactured lift to gain wheelchair access. | Wheelchair lift | STP | Y | N/A | Wheelchair lift | 5433-A | A | 15 | |
| D101099 | OTHER ELEVATORS | This includes elevators not described by the assembly | |||||||||
| categories listed above, such as people lifts. | Dumbwaiter, Electric | STP | CERT | D10951001950 | Dumbwaiter, Electric | 1869-S | S | 25 | |||
| D101099 | OTHER ELEVATORS | This includes elevators not described by the assembly | |||||||||
| categories listed above, such as people lifts. | Dumbwaiter, Hydraulic | STP | CERT | D10951101950 | Dumbwaiter, Hydraulic | 1868-S | S | 25 | |||
| D102001 | MOVING STAIRS | Moving stairs. | Escalator | LF | Y | D10251001950 | Escalator | 9309-M | M | 40 | |
| D102002 | MOVING WALKS | Moving walks. | Escalator | LF | Y | NEED TO DEVELOP SAM JP | M | 40 | |||
| D102099 | OTHER MOVING STAIRS AND WALKS | Moving stairs or walks not described by the assembly categories | |||||||||
| listed above. | General | LF | Y | N/A | NEED TO DEVELOP SAM JP | 20 | |||||
| D109001 | PNEUMATIC TUBE SYSTEMS | Pneumatic tube systems. | Pneumatic tube system | EA | Y | D10952001950 | Pneumatic tube system | 1870-Q | Q | 40 | |
| D109002 | CONVEYORS | Conveyors. | Vertical conveyors | EA | Y | N/A | Vertical conveyors | 5381-S | S | 40 | |
| D109003 | LINEN, TRASH, AND MAIL CHUTES | Linen, trash, and mail chutes. | General | LF | N | 40 | |||||
| D109004 | TURNTABLES | Turntables. | General | EA | N | 40 | |||||
| D109005 | OPERABLE SCAFFOLDING | Operable scaffolding. | General | SF | N | 20 | |||||
| D109006 | TRANSPORTATION SYSTEMS | This assembly includes baggage handling and aircraft loading | |||||||||
| systems. | General | EA | N | 20 | |||||||
| D109007 | OVERHEAD CRANES | Overhead cranes. | Crane, electric bridge, up to 5 ton | EA | Y | E10951221950 | Crane, electric bridge, up to 5 ton | 1863-A | A | 15 | |
| D109007 | OVERHEAD CRANES | Overhead cranes. | Crane, electric bridge, 5 to 15 tons | EA | Y | E10951222950 | Crane, electric bridge, 5 to 15 tons | 1865-Q 1864-A | Q/A | 15 | |
| D109007 | OVERHEAD CRANES | Overhead cranes. | Crane, electric bridge, over 15 tons | EA | Y | E10951223950 | Crane, electric bridge, over 15 tons | 1866-Q 1867-A | Q/A | 15 | |
| D109007 | OVERHEAD CRANES | Overhead cranes. | Crane, manual bridge, up to 5 ton | EA | Y | E10951231950 | Crane, manual bridge, up to 5 ton | 1838-A | A | 15 | |
| D109007 | OVERHEAD CRANES | Overhead cranes. | Crane, manual bridge, 5 to 15 tons | EA | Y | E10951232950 | Crane, manual bridge, 5 to 15 tons | 1842-A | A | 15 | |
| D109007 | OVERHEAD CRANES | Overhead cranes. | Crane, manual bridge, over 15 tons | EA | Y | E10951233950 | Crane, manual bridge, over 15 tons | 1843-A | A | 15 | |
| D109099 | OTHER MATERIAL HANDLING SYSTEMS | Material or handling systems not described by the assembly | |||||||||
| categories | Hydraulic Lift (Automotive), General (Shop Post Lifts) | EA | Y | E10351001950 | Hydraulic Lift, Automotive | 1681-A | A | 20 | |||
| D109099 | OTHER MATERIAL HANDLING SYSTEMS | Material or handling systems not described by the assembly | |||||||||
| categories | General | EA | N | A | 20 | ||||||
| D201001 | WATERCLOSETS | Waterclosets. | Vacuum Breaker Type | EA | N | 25 | |||||
| D201002 | URINALS | Urinals. | General | EA | N | 25 | |||||
| D201003 | LAVATORIES | Lavatories. | General | EA | N | 25 | |||||
| D201004 | SINKS | Sinks. | General | EA | N | 25 | |||||
| D201005 | SHOWERS/TUBS | Showers/tubs. | General | EA | N | 25 | |||||
| D201006 | DRINKING FOUNTAINS AND COOLERS | Drinking fountains and coolers. | General | EA | N | 20 | |||||
| D201007 | BIDETS | Bidets. | General | EA | N | 25 | |||||
| D201099 | EMERGENCY FIXTURES | Emergency fixtures not described by the assembly categories | |||||||||
| listed above. | Eyewash Station & Shower | EA | Y | N/A | Eyewash Station & Shower | 6084-M | M | 25 | |||
| D202001 | PIPES AND FITTINGS | Assemblies include all pipe, fittings, and associated work with |
regard to domestic water supply. The unit of measure at the
| assembly level is number of fixtures. | General | EA | N | 50 |
| D202002 | VALVES AND HYDRANTS | Assemblies include all valves and hydrants. Hose bibbs are |
included in this assembly. The unit of measure at the assembly
| level is number of valves and hydrants. | Butterfly Valve, above 4" (& not included in a system) | EA | Y | D20251201950 | Valve, butterfly, manual, above 4" | 1995-A | A | 25 |
| D202002 | VALVES AND HYDRANTS | Assemblies include all valves and hydrants. Hose bibbs are |
included in this assembly. The unit of measure at the assembly
| level is number of valves and hydrants. | Butterfly Valve, above 4" (& not included in a system) | EA | Y | D20251202950 | Valve, butterfly, auto, above 4" | 1996-A | A | 25 |
| D202002 | VALVES AND HYDRANTS | Assemblies include all valves and hydrants. Hose bibbs are |
included in this assembly. The unit of measure at the assembly
| level is number of valves and hydrants. | Check Valve, above 4" (& not included in a system) | EA | Y | D20251251950 | Valve, check, above 4" | 1997-A | A | 25 |
| D202002 | VALVES AND HYDRANTS | Assemblies include all valves and hydrants. Hose bibbs are |
included in this assembly. The unit of measure at the assembly
| level is number of valves and hydrants. | Backflow Preventer, up to 4" (& not included in a system) | EA | Y | D40151001950 | Backflow prevention device, up to 4" | 1972-A | A | 20 |
| D202002 | VALVES AND HYDRANTS | Assemblies include all valves and hydrants. Hose bibbs are |
included in this assembly. The unit of measure at the assembly
| level is number of valves and hydrants. | Backflow Preventer, over 4" (& not included in a system) | EA | Y | D40151002950 | Backflow prevention device, over 4" | 1973-A | A | 20 |
| D202002 | VALVES AND HYDRANTS | Assemblies include all valves and hydrants. Hose bibbs are |
included in this assembly. The unit of measure at the assembly
| level is number of valves and hydrants. | Ball Valve, above 4" (& not included in a system) | EA | Y | D20251301950 | Valve, cock, ball, above 4" | 1998-A | A | 25 |
| D202002 | VALVES AND HYDRANTS | Assemblies include all valves and hydrants. Hose bibbs are |
included in this assembly. The unit of measure at the assembly
| level is number of valves and hydrants. | Diaphragm Valve, above 4" (& not included in a system) | EA | Y | D20251351950 | Valve, diaphragm, above 4" | 1999-A | A | 25 |
| D202002 | VALVES AND HYDRANTS | Assemblies include all valves and hydrants. Hose bibbs are |
included in this assembly. The unit of measure at the assembly
| level is number of valves and hydrants. | Gate Valve, above 4" (& not included in a system) | EA | Y | D20251401950 | Valve, Gate Above 4" | 2000-A | A | 25 |
| D202002 | VALVES AND HYDRANTS | Assemblies include all valves and hydrants. Hose bibbs are |
included in this assembly. The unit of measure at the assembly
| level is number of valves and hydrants. | Globe Valve, above 4" (& not included in a system) | EA | Y | D20251451950 | Valve, globe, manual, above 4" | 2001-A | A | 25 |
| D202002 | VALVES AND HYDRANTS | Assemblies include all valves and hydrants. Hose bibbs are |
included in this assembly. The unit of measure at the assembly
| level is number of valves and hydrants. | Globe Valve, above 4" (& not included in a system) | EA | Y | D20251452950 | Valve, globe, auto, above 4" | 2002-A | A | 25 |
| D202002 | VALVES AND HYDRANTS | Assemblies include all valves and hydrants. Hose bibbs are |
included in this assembly. The unit of measure at the assembly
| level is number of valves and hydrants. | Motor Operated Valve, above 4" (& not included in a system) | EA | Y | D20251501950 | Valve, motor operated, above 4" | 2003-S | S | 25 |
| D202002 | VALVES AND HYDRANTS | Assemblies include all valves and hydrants. Hose bibbs are |
included in this assembly. The unit of measure at the assembly
| level is number of valves and hydrants. | OS&Y Valve, above 4" (& not included in a system) | EA | Y | D20251551950 | Valve, OS&Y (outside stem and yoke) above 4" | 2004-A | A | 25 |
| D202003 | DOMESTIC WATER EQUIPMENT | This assembly includes equipment associated with the domestic |
water supply, including fittings, and specialties required for hookup.
Assemblies include hot water heaters, water treatment plant, that is, water softeners, filters, distillers, etc.; pumps directly associated with domestic water supply; and tanks for the potable hot or cold water system. The unit of measure at the assembly
| level is pieces of equipment. | Water Heater, Solar -closed loop, up to 6 panels | EA | Y | D20251901950 | Water Heater, Solar -closed loop, up to 6 panels | 1696-S 1702-A | S/A | 25 |
| D202003 | DOMESTIC WATER EQUIPMENT | This assembly includes equipment associated with the domestic |
water supply, including fittings, and specialties required for hookup.
Assemblies include hot water heaters, water treatment plant, that is, water softeners, filters, distillers, etc.; pumps directly associated with domestic water supply; and tanks for the potable hot or cold water system. The unit of measure at the assembly
| level is pieces of equipment. | Water Heater, Gas, to 120 Gallon | EA | Y | D20252601950 | Water Heater, Gas, to 120 Gallon | 1658-S 1661-A | S/A | 25 |
| D202003 | DOMESTIC WATER EQUIPMENT | This assembly includes equipment associated with the domestic |
water supply, including fittings, and specialties required for hookup.
Assemblies include hot water heaters, water treatment plant, that is, water softeners, filters, distillers, etc.; pumps directly associated with domestic water supply; and tanks for the potable hot or cold water system. The unit of measure at the assembly
| level is pieces of equipment. | Water Heater, Oil fired to 100 gals | EA | Y | D20252602950 | Water Heater, Oil fired to 100 gals | 1662-S 1666-A | S/A | 25 |
| D202003 | DOMESTIC WATER EQUIPMENT | This assembly includes equipment associated with the domestic |
water supply, including fittings, and specialties required for hookup.
Assemblies include hot water heaters, water treatment plant, that is, water softeners, filters, distillers, etc.; pumps directly associated with domestic water supply; and tanks for the potable hot or cold water system. The unit of measure at the assembly
| level is pieces of equipment. | Water Heater, steam coil, to 2500 gals | EA | Y | D20252603950 | Water Heater, steam coil, to 2500 gals | 1667-S 1669-A | S/A | 25 |
| D202003 | DOMESTIC WATER EQUIPMENT | This assembly includes equipment associated with the domestic |
water supply, including fittings, and specialties required for hookup.
Assemblies include hot water heaters, water treatment plant, that is, water softeners, filters, distillers, etc.; pumps directly associated with domestic water supply; and tanks for the potable hot or cold water system. The unit of measure at the assembly
| level is pieces of equipment. | Water Heater, Electric | EA | Y | D20252603950 | Water Heater, Electric | 6576-S | S | 25 |
| D202004 | INSULATION AND IDENTIFICATION | Assemblies include insulation used in association with domestic |
water supply. The unit of measure at the assembly level is
| number of fixtures. | General | EA | N | 25 |
| D202005 | SPECIALTIES | Any other special items associated with domestic water supply. |
All associated work items, including pipes, fittings, valves, insulation, and hookup should be included in this assembly. The unit of measure at the assembly level is pieces of special
| equipment. | Pressure Relief Valve, above 4" (& not included in a system) | EA | Y | D20252621950 | Valve, pressure relief, above 4" | 2005-A | A | 25 |
| D202005 | SPECIALTIES | Any other special items associated with domestic water supply. |
All associated work items, including pipes, fittings, valves, insulation, and hookup should be included in this assembly. The unit of measure at the assembly level is pieces of special
| equipment. | Pressure Regulator Valve > 4" (& not included in a system) | EA | Y | D20252651950 | Valve, pressure regulator, above 4" | 2006-A | A | 25 |
| D202005 | SPECIALTIES | Any other special items associated with domestic water supply. |
All associated work items, including pipes, fittings, valves, insulation, and hookup should be included in this assembly. The unit of measure at the assembly level is pieces of special
| equipment. | Sediment Strainer Valve > 4" (& not included in a system) | EA | Y | D20252701950 | Valve, sediment strainer, above 4" | 2007-A | A | 25 |
| D202005 | SPECIALTIES | Any other special items associated with domestic water supply. |
All associated work items, including pipes, fittings, valves, insulation, and hookup should be included in this assembly. The unit of measure at the assembly level is pieces of special
| equipment. | Automatic Valve, above 4" (& not included in a system) | EA | Y | D20253101950 | Valve, auto, above 4" | 1993-A | A | 25 |
| D202005 | SPECIALTIES | Any other special items associated with domestic water supply. |
All associated work items, including pipes, fittings, valves, insulation, and hookup should be included in this assembly. The unit of measure at the assembly level is pieces of special
| equipment. | Auto Diaphragm Valve, above 4" (& not included in a system) | EA | Y | D20253102950 | Valve, auto diaphragm, above 4" | 1994-A | A | 25 |
| D202099 | OTHER DOMESTIC WATER SUPPLY | Domestic water supply not described by the assembly categories | ||||||
| listed above. | General | EA | N | 20 | ||||
| D203001 | WASTE PIPE AND FITTINGS | Assemblies include all pipe, fittings, and associated work with |
regard to sanitary waste pipe and fittings. The unit of measure at
| the assembly level is number of fixtures. | General | EA | N | 50 |
| D203002 | VENT PIPE AND FITTINGS | Assemblies include all pipe, fittings, and associated work with |
regard to sanitary vent pipe and fittings. The unit of measure at
| the assembly level is number of fixtures. | General | EA | N | 50 |
| D203003 | FLOOR DRAINS | Assemblies include all floor drains. Hub drains are considered to |
be pipe and are not included in this category. The unit of
| measure at the assembly level is number of drains. | General | EA | N | 25 |
| D203004 | SANITARY AND VENT EQUIPMENT | This is equipment associated with the sanitary waste system, |
including fittings and specialties required for hook-up.
Assemblies include waste treatment equipment, that is, sluice gates, incinerators, etc.; pumps for sewage injection; and holding tanks for the domestic water system. The unit of measure at the
| assembly level is pieces of equipment. | Pumps | EA | N | 25 |
| D203005 | INSULATION AND IDENTIFICATION | Assemblies include insulation used in association with sanitary |
waste and vent system. The unit of measure at the assembly
| level is number of fixtures. | General | EA | N | 25 |
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.