This statement of work outlines requirements for an underwater hull and freeboard side scan ultrasonic survey of a Coast Guard cutter. The contractor will conduct an automated crawler ultrasonic inspection scan of the underwater hull plating and entire freeboard up to the main deck edge. The inspection will identify all metal corrosion and deterioration. The contractor must submit a Coordination, Information and Review report and perform initial inspection/test reporting. Standards and specifications are provided for the automated ultrasonic inspection, including coverage areas, evaluation criteria, and report requirements. A color-coded composite mosaic image and separate plate scans must be included in the electronic side scan report.

The related solicitation is for an underwater hull and freeboard side scan ultrasonic survey in support of hull plating inspections for the Department of Homeland Security Coast Guard. Requirements include those outlined in the statement of work.

View the file

Other files

File Type Posted
154-WPC_997_302_1_-_-.pdf PDF
154B-WPC_111_301_1_-_A.pdf PDF
154-WPC_111_301_1_-_B.pdf PDF
YD_85_41_1_-_A.pdf PDF
Statement of Work.pdf PDF
FAR Clauses.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

11100_JLW_0321_154

Hull Plating, Inspect

1. SCOPE

1.1 Intent. This work item describes the requirements for the Contractor to conduct an inspection of the hull shell plate and inaccessible voids and to perform the designated hulls scans as specified below. Measurement readings will need to be taken with existing coating systems intact.

TABLE 1 – elevated inspection scans

included
Scan Type
YES
Conduct an automated crawler ultrasonic inspection scanning (i.e. SIDESCAN) of underwater hull plating and entire freeboard, up to the main deck edge to detect all metal corrosion and deterioration. See paragraph 3.6.1 for requirements.

If “YES” appears in the left-column cell then the corresponding scan work is required, must be quoted on, and executed during the contract performance period. If “NO” appears in the cell then the corresponding scan work is NOT required, must NOT be quoted on, nor executed during the contract performance period.

1.2 Government-furnished property.

None.

2. REFERENCES

Coast Guard Drawings Coast Guard Drawing 154 WPC 111-301, Rev B, Shell Expansion Coast Guard Drawing 154 WPC 997-302, Rev -, Docking Plan (Supersedes DWGS 154-WPC-997-1, 997-301) Coast Guard Publications Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2020, General Requirements Surface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2020, Welding and Allied Processes Other References ASTM International (ASTM) D5363, 2008; Standard Specification for Anaerobic Single-Component Adhesives (An) MIL-S-45180, 1998; Sealing Compound, Gasket, Hydrocarbon Fluid and Water Resistant

3. REQUIREMENTS

3.1 General.

3.1.1 CIR. The Contractor must submit a CIR for the inspections listed in the following paragraph(s):

3.4 Initial inspection/test report submission.

3.1.2 Tech Rep. None.

3.1.3 Protective measures. The Contractor must furnish and install all protective measures in accordance with SFLC Std Spec 0000, paragraph 3.3.3 (Vessel component, space, and equipment protection).

3.1.4 Interferences. The Contractor must handle all interferences in accordance with SFLC Std Spec 0000, paragraph 3.3.5 (Interferences).

3.6.1 Automated ultrasonic inspection (SIDESCAN) standards and specifications. When performing this type of scan, all shell plate thickness discrepancies must be identified and reported, while accomplishing and conforming to the following:

3.6.1.1 All scanning work must be performed in the presence of the Coast Guard Inspector or COR. The KO may request that evidence be submitted proving that, at all times, one or more of the on-site technicians, who are performing or overseeing the scan work, meet all qualifications set forth below:

have successfully operated the automated plate thickness scanner being used in this contract during at least one similar contract are conforming to all ASNT Recommended Practice No. SNT-TC-1A 2006 requirements possess ASNT Level III analyst certifications for overseeing the entire scanning process and for evaluating all data obtained during scanning.

possess ASNT Level III or II analyst certification for operating a hand held meters

3.6.1.2 An “Echo-To-Echo Transducer” is authorized for use.

3.6.1.3 The automated scanning machine must cover all areas of the hull (below the water line and entire freeboard area) up to a maximum of six inches around obstacles. Acceptable obstacles include sea suctions, discharges, rudderposts, anodes, stern tubes, drydock blocks and areas blocked by immovable scaffolding or shipyard activity.

3.6.1.4 The automated scanner must be capable of scanning all convex areas with a radius of 8 inches and greater and concave areas with a radius of 12 inches and greater.

3.6.1.5 Complete Rapid Ultrasonic Gridding inspection taken on 1” grids working around wind girders. Provide the lowest reading within each 3”x3” grid, paired with XY coordinates and still frame images. Include findings in a PDF Inspection Report Summary. Provide 3D digital twin including UT data on 1" grids with 3" bins merged with still frame images.

3.6.1.6 Hand held scanning must be accomplished in areas not covered by the automated scanning, and in areas where the automated scanner loses data due to sharp dents, surface irregularities, roughness, etc. Follow these guidelines:

the hand held meter must be calibrated each time it is powered up for use using an ASNT certified calibration block made of mild steel. Demonstrate that the equipment is calibrated prior to and immediately after scanning.

the hand held meter must be set to a resolution of 2.0” x 2.0” or better.

supplemental hand held readings must be provided on any area of the hull identified as thinner than the criteria for repair defined in paragraph titled “Evaluation criteria” below.

a resolution set to 1.0” x 1.0” or better must be used in areas where the automated scanner loses data

3.6.1.7 Measure the average paint thickness in order to provide a more accurate metal thickness at all scanned points. The average paint thickness must be clearly defined in the reports.

3.6.1.8 Evaluation Criteria. Use the following evaluation criteria for all scanned plating (underwater body and freeboard):

Plates where scan data indicates wastage greater than or equal to 25% nominal plate thickness must be highlighted in “RED” and designated “repair areas”.

Plates where scan data indicates wastage between 10% to 24% of nominal plate thickness must be highlighted in “YELLOW”.

Plates where scan data indicates wastage less than 10% of nominal plate thickness must be highlighted in DARK GREEN.

3.6.1.9 Label each plate on the hull designated for inspection as per the CG drawings listed in Section 2.

3.6.1.10 Outline areas measured with the hand held meter on the hull.

3.6.1.11 Outline in WHITE or YELLOW all areas on the hull identified with 25% or greater deterioration.

NOTE

The colors used to label repair areas must not be used for any other markings on the hull.

3.6.1.12 Develop an electronic file side scan report comparing the results and the plate drawings (to be submitted with the CIR specified above). The reports must include the following contents (minimum):

Findings narrative summary Plate summary – must be in table format with at minimum a column for plate identification, repair identification, location of repair area, size of repair area, and brief description (i.e. exterior pitting, hole, interior corrosion, etc.)

A composite mosaic of the scan images overlaid on the appropriate shell plate expansion drawing as listed in paragraph titled “Evaluation criteria” above.

A separate page for each plate with a scan image of that plate only. Each page must contain the following:

· Plate nominal thickness(es).

· A legend showing plate thickness for green, yellow and red criteria.

· All repair areas must be outlined in blue in the scan image as they are marked on the hull.

· All unusual areas on the scan such as rough surface, etc. must be called out and noted in blue.

· Plate orientation relative to the cutter must be identified.

Provide an individual photo for each plate requiring repairs.

Raw data files.

3.6.1.13 The report must be organized as follows and included in the "Initial inspection/test report submission" described above with two copies of the side scan report on unprotected/editable compact discs (CDs).:

Table of contents Plate summary Complete port side mosaic showing colorized results Port side scan and digital photos of each plate in sequential order Complete starboard side mosaic showing colorized results Starboard side scan and digital photos of each plate in sequential order Transom scan and digital photos

NOTE

All files must be compatible with USCG standard workstation software (i.e., AutoCAD, MS Office, Adobe PDF, JPEG format).

4. NOTES

4.1 Data rights. All data regardless of form or medium must be the sole property of the US Coast Guard and must not be released without the written consent of the US Coast Guard.