Questions_and_Answers_-_Amend_1.pdf
PDF 74 KB Posted
- Attached to
- Progressive Structural Inspection (PSI) and Depot Level Maintenance (DLM) for US Government C-130J Aircraft
- Solicitation number
- 70Z03819RH0000002
About this file
Questions and Answers - Amendment 1
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Document Section Question Answer
SOW 1.3
The SOW references the USCG C-130 Depot Maintenance Procedure Cards (DMPC) in Attachment 1. Would the Government please advise when that Technical Data will be availaible for all competitors?
The Technical Data package will be made available upon written request.
Attachment 1 to the solicitation is and will remain the Schedule of Services. The attachments to the SOW will be changed as follows:
Attachment 1 - Milestone Hours (provided)
Attachment 2 - DMPCs (list provided. Actual DMPCs will be provided upon written request.)
Attachment 3 - Government Furnished Material (provided)
Attachment 4 no longer exists. The Ground and Flight Operations Service Guidance COMDISNT M13020.3 (series) This guidance will be provided upon written request.
Attachment 5 no longer exists - A comprehensive list of applicable regulations, instructions, flight manuals, and technical publications will be provided upon written request.
Attachment 6 no longer exists. The list of components covered by the Engine PBH contract will be provided upon written request.
Attachment 7 no longer exists. Paint Drawings will be provided upon written request.
Attachment 8 no longer exists. Forms for reporting GFE will be provided at contract award.
SOW
Numerous Sections
The SOW refers to Attachment 1. Attachment 1 of the Solicitation is the Schedule and Attachement 1 of the SOW is the
Milestone Averages for Labor Hours. Would the Government please correct this?
SOW 2.2.5.7
The SOW references the applicable Block Upgrade 8.1 TCTO's.
Would the Government please advise when this Technical Data will be made available to all competitors?
The Technical Data package will be made available upon written request.
Solicitation N/A
"In regards to the subject RFP, wil the HC-130/J Progressive Structural Inspection (PSI) and Depot Level Maintenance (DLM) Specification and/or associated task cards as well as the paint spec be made available to bidders?
The Technical Data package will be made available upon written request.
Sheet1
File details come from the government source that posted it.