Statement of Work
Firing Range Services – Detroit, MI
The Department of Homeland Security (DHS) has a requirement for a firearms range to conduct advanced firearms training. The agency’s training requirements are contingent upon a variety of factors (e.g. new hires, retirements, separations, revised training curriculum, etc.). If additional training hours are required above and beyond the contracted number of hours, they are within the scope of the contract. However, in no instance shall the contractor exceed the contracted number of hours without prior, written consent of the Contracting Officer. This written consent will take the form of a contract modification to add additional hours.
The range must comply with applicable, local, state and federal regulations, including but not limited to, lead exposure. The contractor shall submit its most recent certification of lead exposure testing and/or its most current OSHA compliance certificate/letter and air sample for lead.
If an award is granted and OSHA standards are not in accordance with regulation, the government has the unilateral right to terminate the contract at any time via a written signed modification.
The following OSHA programs are applicable:
Lead:
• 29 Code of Federal Regulations (CFR) 1910.1000, Air contaminants http://www.gpo.gov/fdsys/pkg/CFR-2014-title29-vol6/pdf/CFR-2014-title29-vol6-sec1910-1000.pdf
• 29 CFR 1910.1025
http://www.access.gpo.gov/nara/cfr/waisidx_10/29cfr1910a_10.html
• Environmental Protection Agency (EPA): Best Management Practices for Lead at Outdoor Shooting Ranges.
http://www2.epa.gov/lead/best-management-practices-lead-outdoor-shooting-ranges-epa- 902-b-01-001-revised-june-2005 Signs and tags:
• Section 1910.145 https://www.osha.gov/Reduction_Act/TAGS-SUP.html
The range shall meet the following standards to qualify for consideration:
• The range shall be within a 10-mile radius of the Detroit Metropolitan Wayne County Airport.
• The location shall be accessible via primary travel on a major thoroughfare with travel time no greater than one-half hour.
• DHS will have priority of use / scheduling so long as a 90-day advance notice is provided.
• Training by DHS personnel cannot be audio or visually recorded or photographed without prior written consent from DHS.
• Approximately 50,000 rounds are anticipated to be fired each quarter.
http://www.gpo.gov/fdsys/pkg/CFR-2014-title29-vol6/pdf/CFR-2014-title29-vol6-sec1910-1000.pdf http://www.gpo.gov/fdsys/pkg/CFR-2014-title29-vol6/pdf/CFR-2014-title29-vol6-sec1910-1000.pdf http://www.access.gpo.gov/nara/cfr/waisidx_10/29cfr1910a_10.html http://www2.epa.gov/lead/best-management-practices-lead-outdoor-shooting-ranges-epa-902-b-01-001-revised-june-2005 http://www2.epa.gov/lead/best-management-practices-lead-outdoor-shooting-ranges-epa-902-b-01-001-revised-june-2005 http://www2.epa.gov/lead/best-management-practices-lead-outdoor-shooting-ranges-epa-902-b-01-001-revised-june-2005 https://www.osha.gov/Reduction_Act/TAGS-SUP.html
• Due to seasonal climate, an indoor range may be used when the weather prevents the use of an outdoor range:
• Indoor firing positions will be covered and have centralized heating and air-condition.
• Indoor range must have a structure that provides protection for up to 15 persons during each training session.
• The range must have electrical outlets at the structure site.
• The designated range area must be closed to the public and public observation during the corresponding hours of DHS use.
• All ranges must possess a minimum of 12 firing positions with distinct shooting positions for the 1.5, 3, 7, 15 and 25-yard lines.
• Firing line(s) will be clearly marked and continue for the full length of the firing position.
• All ranges must possess target carriers to hold targets or remote controlled turning targets compatible with various target sizes.
• All ranges must accommodate the use of portable steel targets.
• All ranges must be able to accommodate all handgun calibers including no lead frangible ammunition for steel targets.
• All ranges must accommodate all types of shotgun and rifle ammunition.
• Range shall accommodate the full Surface Danger Zone (SDZ), Vertical Danger Zone (VDZ), and ricochet danger for the types of ammunition being used.
• Weapons cleaning area will be covered or enclosed. If enclosed, the temperature must be maintained between 67 to 82 degrees Fahrenheit while occupied in accordance with ASHRAE Standard 55-2013.
• Weapons cleaning area shall be large enough to accommodate cleaning tables/benches and cleaning materials.
• If a firing booth is not being used, the width of firing positions shall be at least five feet.
• Discharge of storm water runoff and drainage shall meet all local, state, and federal laws and/or regulations.
• Range rules must not disallow students from:
• Drawing and firing from the holster.
• Turning and then drawing and firing from the holster.
• Multiple shot and rapid-fire drills.
• Shooting while moving forward of the firing points when instructed and monitored by a qualified firearms instructor, (i.e., tactical movements and other tactical shooting style drills).
• Shooting from the standing, kneeling and prone positions.
• Moving between firing points or positional transition shooting (i.e. standing to kneeling transitions).
• Shooting from behind barricades.
• Range shall provide:
• Parking for up to 15 vehicles
• Movable / removable barricades for use at the 15 and 25 yard lines.
• Any barricades, barricade holders or covering supports on the range shall be constructed of a material that does not deflect/ricochet rounds that inadvertently strike it. (Example: wood)
• Sweeping equipment and collection containers, or equivalent, for all expended casings.
• Classroom / conference room facility suitable for up to 15 persons, with a marker board or equivalent.
• The designated area must be closed to the public during the corresponding hours of DHS use.
• The range must have male/female washroom/restroom facilities with running water in proximity.
• Signal for cellular phone service must be adequate or if signal cannot be obtained a landline must be installed for emergency calling.
• Disposal of all contaminants associated with live fire, including bullet trap / ventilation filter etc. will comply with local, state and federal regulations and is the responsibility of the contracted range.
• Electrical outlets and wiring will meet applicable federal, state, and local codes.
• Emergency egress plans and fire protection will be in compliance with local, state, and federal regulations and will not require travel downrange from the primary firing line.
• Warning signs will be in accordance with OSHA standard section 1910.145.
• Roads and parking will be accessible by passenger vehicle, light or medium trucks, and vans.
• For low light/night live fire on all days scheduled.
• A public address system
• A securable storage area solely for DHS use. Storage area will be used for administrative supplies, training aids, tools, and miscellaneous items.