Attachment 1 Personal Radiation Detector - Requirements
ID# Parameter Threshold Objective Reference Clarification Meets (M) or
Does Not Meet (DNM) Reference/Explanation
SL-1 Maximum size The PRD shall have dimensions less than 20 cmx10cmx5cm excluding any holster or carrying case.
Threshold=Objective IAW ANSI N42.32, Section 5.2.1
SL-2 Maximum mass The PRD shall have a maximum mass of 400g.
Threshold=Objective IAW ANSI N42.32, Section 5.3.1
SL-3 Detector(s) The PRD shall have gamma detectors only.
Threshold=Objective -
SL-4 Alarm types The PRD shall have visual, audible and vibration alarms. At least one type of alarm must be operational under any configuration of the PRD.
Threshold=Objective -
SL-5 Acoustical alarm The PRD shall have an acoustical alarm with a weighted sound level between 85 dB(A) and 100 dB(A) at least 30 cm from the alarm source.
Threshold=Objective IAW ANSI N42.32, Section 5.10.2
SL-6 Rate of false alarm The false alarm rate for gammas shall be less than or equal to 2 alarms in 8 hours when operated in a stable, non-radiological background environment.
Threshold=Objective IAW ANSI N42.32 2016, Section 6.1, SL-7
KPP-1
Gamma alarm The PRD shall alarm within 2 s after exposure to an increase in the ambient
Alarm within 2 s after exposure to an
ANSI N42.32, 2016,
Section 6.2
Reference/Explanation dose equivalent rate level of 50 µR/h (-0 %, +20 %) above background for Cs-137 when moving at a speed of 1.2 m/s (+/- 10 %) at a distance of closest approach of
1.5 m.
increase in the ambient dose equivalent rate level of 50 µR/h (-0 %, +20 %) above background for Co-60 and Am-241, when moving at a speed of 1.2 m/s (+/-10 %) at a distance of closest approach of
1.5 m.
SL-08 Detection of gradually increasing gamma radiation
The PRD alarm threshold shall not be affected by slowly increasing radiation (0.5 m/s).
In accordance with ANSI N42.32, 2016:
For 137Cs:
Alarm in ≤ 2 s after reaching a distance of closest approach for 10 out of 10 trials.
Threshold=Objective ANSI N42.32, 2016, Section
6.4 (gamma only)
SL-09
Over-range indication
The PRD shall have an indication of an over- range condition when the ambient dose equivalent rate is greater than 2 times of the manufacturer-stated over-range condition.
• The manufacturer shall state the ambient dose equivalent rate at which the PRD indicates the over- range condition.
• The PRD shall indicate that an over-range condition exists when the ambient dose equivalent rate is greater than the manufacturer-stated over-range. During the over-range condition, the alarm indication shall stay activated.
• The PRD shall recover within 1 min after removing the over-range exposure.
Threshold=Objective IAW ANSI N42.32 2016, Section 6 for Test 1 and 2 only. For Test 3 of Section 6, the mean reading shall be within 10% of the initial mean after each trial;
refer to the clarification notes here.
For clarification, the test procedure is as follows:
1. Prior to the over range test, expose the PRD to the same 50 uR/h Cs-137 test field used for the gamma alarm test. Collect 10 readings and calculate the mean response. This is the pre-test response. Remove the source.
2. Expose the PRD at the required over range dose rate using Cs-137 (2x manufacturer’s stated max) for a period of 1 min and verify the PRD indicates that an over range condition exits
3. Remove the over range exposure rate and verify the PRD returns to the response observed prior to the over range exposure within 1 min.
Reference/Explanation
4. Repeat the pre-test exposure with the Cs-137 source placed in the same position used to obtain the pre-test mean. Collect 10 readings and verify that the mean response is within 10% of the mean response obtained prior to the PRD being exposed to the 2x radiation field.
SL-09-1 PRDs with a unit-less display shall have a table to convert the unit-less reading into a gamma response (i.e., exposure rate, dose rate).
The table provided shall show exposure/dose rate range for each integer reading for Cs- 137.
Threshold=Objective STC Requirement
SL-10 Functionality test for environmental, electromagnetic and mechanical tests
The PRD shall pass functionality tests for environmental, electromagnetic and mechanical standards, as tested IAW ANSI N42.32 2016, Section 4.8
Threshold=Objective IAW ANSI N42.32, 2016, Section 4.8
SL-11 Ambient temperature The PRD shall pass functionality test from - 20 °C to +50 °C for ramp and shock change.
Threshold=Objective IAW ANSI N42.32, Section 7.1.1
SL-12 Temperature shock The PRD shall pass ANSI N42.32 2016 tests for temperature shock.
Threshold=Objective IAW ANSI N42.32, Section 7.2
Reference/Explanation
SL-13 Extreme temperature start up
The PRD shall be able to operate when switched on at the cold temperature limit (-20°C) and at the high temperature limit (50°C).
Threshold=Objective IAW ANSI N42.32, Section 7.5
SL-14 Relative humidity range
The PRD shall pass functionality test from 40% to 93% at 35°C
Threshold=Objective IAW ANSI N42.32, Section 7.3
SL-15 Moisture and dust protection
The PRD shall pass IP53 requirements for moisture and dust protection.
Threshold=Objective IAW ANSI N42.32, Section 7.4.1
SL-16 Mechanical drop The PRD shall function correctly and alarm correctly after being subjected to drops on each of its six surfaces from a height of 1.5 m onto a concrete floor, the PRD shall function correctly and alarm at a change in the radiation field.
Threshold = Objective IAW ANSI N42.32
Section 9.2
SL-17 Vibration The PRD shall withstand random vibration with spectral density of 0.01 g2Hz-1 with endpoints of 5 Hz and 500 Hz.
Threshold=Objective IAW ANSI N42.32, Section 9.1
SL-18 Impact (microphonics) The PRD's response shall be unaffected by 0.2 J impacts, such as those that may occur from low intensity impacts from sharp contact with hard surfaces. No alarms or spurious indications shall occur as a result of the impacts alone.
Threshold=Objective IAW ANSI N42.32, Section 9.3.1
Reference/Explanation
SL-19 Battery lifetime The batteries that are used shall be widely available, shall not be unique to the PRD, and shall be replaceable in the field with tools that are easily obtained or are commercially available (e.g., screwdriver, coin).
Threshold=Objective Test method IAW
ANSI N42.32 2016,
Section 5.13.1
The batteries shall be capable of powering the PRD in a non-alarm state for 24 h.
The batteries shall be capable of powering the PRD audible, visual, and vibration (if available) alarms for 30 min while continuously alarming.
SL-20 Low battery indication The PRD shall have a low battery indication.
Threshold=Objective Verified through review of technical manual and visual observation of the instrument display.
SL-21 Electrostatic discharge
The PRD shall not be affected by exposure to electrostatic discharges at voltages of up to ± 6kV using the contact discharge technique.
Threshold=Objective IAW ANSI N42.32
Section 8.1.1
SL-22 RF Immunity The PRD shall not be affected by radio-frequency (RF) fields over the frequency range of 80 MHz to 2.5 GHz at an intensity of 50 V per meter (V/m) 80% amplitude modulated with a 1 kHz sine wave.
Threshold=Objective IAW ANSI N42.32
Section 8.2.1
Reference/Explanation
SL-23 Radiated emissions The PRD radiated emission limits, when measured at 3 m, shall be less than the values as described in the FCC/CFR15.109 rules for unintentional radiators Class A digital devices.
Threshold=Objective IAW ANSI N42.32
Section 8.4.1
SL-24 Magnetic fields When exposed to a 100 A/m (1.3 gauss) 60 Hz AC magnetic field in all three mutually orthogonal orientations, the PRD shall function correctly. No alarms or spurious indications shall occur as a result of the magnetic field alone.
Threshold=Objective IAW ANSI N42.32
Section 8.3.1
SL-25 Data format for near real time data transmission
As a minimum, the transmitted data shall contain the following information:
• Manufacturer name
• Instrument model
• Serial number
• Software version
• Gamma detector kind (e.g., Csl(TI), Nal(TI), GMT)
• Date and time of measurement
• Measured radiation levels (e.g., exposure rate, dose rate, or level)
• Gamma-ray alarm indication.
The transfer protocol shall be fully described in the technical manual. When used, wireless techniques shall have the ability to be encrypted.
Threshold=Objective ANSI N42.32 2016, Section 9.14.1 and STC requirements
Reference/Explanation
SL-26
KPP-2
The PRD shall be able to transmit near real time data to mobile devices.
Ability to connect with and transmit data to smart phones and tablets, using Android 6.0 and higher and iOS 9.3 and higher.
Threshold=Objective STC Requirement
SL-26-1 Communications The PRD shall have Bluetooth 4.0 or better.
Threshold=Objective STC Requirement
SL-27 Software Vendor shall provide Windows based PC set up software (Windows OS 7 and 10 at a minimum)
Threshold=Objective STC Requirement
SL-28
KPP3
Vendor shall provide smart phone applications for near real time data transmission (Android
6.0 and higher and iOS 9.3 and higher) and/or be required to adapt their PRD data feed for use with existing CWMD STC mobile applications and near real time data transmission protocols, when available.
Vendor shall provide smart phone application for logging/storing data and alarms with the ability to track events on integrated mapping systems. Application shall have the ability to send PRD data and associated geospatial information from smart phone to a CWMD STC data center.
Threshold=Objective STC Requirement
Android app must be available upon receipt of order, iOS app within 4 months of receipt of order.
CWMD STC uses Open Geospatial Consortium (OGC) GIS environments.
Interface protocol is based on an IOT model and messaging protocol.
SL-29 Vendor shall provide interactive manual and training course.
Vendor shall provide smart phone interactive manual and training for use on Android 6.0 and higher and iOS 9.3 and higher systems to be delivered within 3 months of receipt of order.
Threshold=Objective STC Requirement Training for PRD developed per CWMD STC provided curriculum that focuses on basic functional use and care of PRD. Intent is a simple refresher training tool for use with a mobile device.
SL-29-1 Vendor shall provide a means to record and track student training and test scores taken
Tracking process shall be compatible with and/or able to export compatible files to DHS/CWMD/STC's student tracking application.
Reference/Explanation via the interactive smart phone application.
SL-31 PRDs shall have
DHS/CWMD/STC
approved inventory control stickers and be recorded on an inventory data file.
PRDs shall be delivered with CWMD approved inventory control stickers adhered to the PRDs and with a CD containing completed relevant sections of a bulk upload inventory spreadsheet.
Threshold=Objective STC Requirement CWMD STC will provide details of format of inventory control stickers and spread sheet at time of award.
SL-32 Vendor shall provide one day (8 hours) of training on basic repair and maintenance of PRD. The number of deliveries will be determined at the time of the award.
Topics include but are not limited to:
• Repair and replacement of basic parts (buttons, rubber sleeves, battery covers, plugs, display faces, etc.)
• Use of PRD set up software
• Use of any related field calibration kits
Class size shall be limited to 25 students per delivery. Delivery method shall be an instructor led classroom training at a training site designated by CWMD STC.
Threshold=Objective STC Requirement
SL-33 Vendor shall provide list and pricing for commonly replaced parts, related to basic
Vendor shall supply a price list of commonly replaced and repaired parts referenced in SL-32 as part of the response.
Reference/Explanation maintenance training class (see SL-32).
SL-34 The PRD shall provide cybersecurity protection.
The vendor shall provide a detailed description of the Bluetooth protocols used, to include but not limited to: the level of security, method of pairing and type of encryption used.
Threshold = Objective STC Requirement
SL-35 The PRD shall display radiation levels
Radiation levels should be displayed using one or more of the following methods:
— Digital display: The PRD directly displays the measured exposure rate, dose rate, ambient dose equivalent rate or count rate (e.g., μR/h or cps).
— Unit-less display: The PRD displays a numerical value that may be proportional to the radiation field but is not explicitly reported as the exposure, dose, or ambient dose-equivalent rate or count rate.
— Non-numerical display:
The PRD displays a non-numerical indication of the intensity of the radiation field (e.g., bar-graph, colored LEDs).
Threshold=Objective IAW ANSI N42.32, 2016, Section 5.8
SL-35-2 Display independent of phone
The PRD itself shall have a display in addition to the user interface of a mobile device, when the mobile application is used.