Attachment C .pdf

PDF 3 MB Posted

Attached to
STORM WATER MAINTENANCE SERVICES Federal contract opportunity
Solicitation number
70LCHE21QPFB00004
Issued by
Department of Homeland Security Federal Law Enforcement Training Center

View the file

Other files for this federal contract opportunity

Other files attached to STORM WATER MAINTENANCE SERVICES, newest first.
File Type Posted
Amd 0002.pdf PDF
Questions.pdf PDF
Attachment A - Ponds 1-5.pdf PDF
Attachment B - Pond 6.pdf PDF
AMD 01.pdf PDF
Attachment D.2 - MD SWM Volume 2.pdf PDF
Attachment C - GOT004 FLETC (Solar Array) BMPs.pdf PDF
Pond-II.pdf PDF
Pond-I.pdf PDF
Attachment E - Technical Memorandum No. 9.pdf PDF
Attachment D.1 - MD SWM Volume 1.pdf PDF
Attachment A - FLETC-OCH Stormwater Conveyance System Map.pdf PDF
Attachment B - B109 (Sim City) BMP Plans.pdf PDF
Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 2 3 4 5 6

A

B

C

D

E

CHELTENHAM INDOOR FIRING RANGE

CHELTENHAM, MARYLAND

BUILDING 5

emruffer Highlight emruffer Highlight

B

C

D

E

B

C

D

B

C

D

B

C

D

B

C

D

C-001

GENERAL NOTES, LEGEND AND ABBREVIATIONS

JAW CKB

C-001.dwg

WATER VALVE

STORM DRAIN MANHOLE

TOP OF CURB

SANITARY MANHOLE

SANITARY CLEANOUT

PERCENT

MATCH GRADE

MAXIMUM

FINISH FLOOR ELEVATION

FIRE HYDRANT

APPROXIMATE

ELEVATION

CORRUGATED METAL PIPE

CENTERLINE

CONCRETE

BUILDING

EXISTING SANITARY SEWER

EXISTING WATER

DROP INLET

ELECTRICAL MANHOLE

LIGHT POLE

DIAMETER

TELEPHONE

TEMPORARY BENCHMARK

SILT FENCE

POST INDICATOR VALVE

BRICK

WATER METER

NORTHWEST

NORTHEAST

SOUTHEAST

SOUTHWEST

CUBIC FEET PER SECOND

WM

WV

W

TYP.

AT

WIDE / WEST

TYPICAL

SW

TC

TEL, TELE

TBM

STY

SF

STORY

ALL AREAS OUTSIDE THE PROJECT LIMITS DISTURBED BY CONSTRUCTION OR

OPERATIONS AND ARE NOT OCCUPIED BY BUILDINGS, PAVING, OR OTHER SURFACES

ALL AREAS WITHIN THE PROJECT LIMITS THAT ARE DISTURBED BY CONTRACTOR'S

ALL DIMENSIONS TO CURBS ARE TO THE FACE OF CURB UNLESS INDICATED

MOBILIZATION SHALL BE RESTORED TO THEIR ORIGINAL CONDITION UNLESS

OTHERWISE. DIMENSIONS TO BUILDINGS ARE TO BRICK VENEER AND/OR TO FACE

SPECIFIED OTHERWISE.

1.

OF CONCRETE STRUCTURES.

SAN MH/SMH

SDMH

SCO

SE

R

PIV

RADIUS

NW

MIN.

M.G.

NE

MINIMUM

F.F.E.

INV.

MAX.

LP

FH

INVERT

EL.

ES

EW

EMH

CONC.

ø/DIA.

DI

BR.

CFS

CMP

LC

BLDG.

APPROX

(301) 434-7000

SILVER SPRINGS, MD. 20903

1751 ELTON ROAD, SUITE 300

CHARLES P. JOHNSON & ASSOCIATES, INC.

(NGVD29)[NGVD29-NAVD88=0.78']

VERTICAL DATUM BASED ON THE NATIONAL GEODETIC VERTICAL DATUM OF 1929.

BM NO. 1 AT BUILDING 1A WAS FOUND AND ITS ELEVATION INDICATES A3.

THE NORTH AMERICAN VERTICAL DATUM OF 1988(NAVD88).

THE VERTICAL DATUM SHOWN HEREON IS BASED ON GPS OBSERVATIONS AND ON

OBSERVATIONS ON MARYLAND STATE PLANE DATUM NAD83/91.

THE HORIZONTAL DATUM SHOWN HEREON IS BASED ON GPS AND CONVENTIONAL

THE TOPOGRAPHIC SURVEY WAS PREPARED BY:4.

2.

1.

2.

3.

SOUTHS

N NORTH

EASTE

SHALL BE TOPSOILED AND SEEDED.

MARYLAND STATE HIGHWAY ADMINISTRATIONMDSHA

MARYLAND DEPARTMENT OF THE ENVIRONMENTMDE

PEDESTALPED

CHECK DAMCD

STANDARD INLET PROTECTIONSIP

SURVEY NOTES

GENERAL NOTES ABBREVIATIONS

TELEPHONE PEDESTAL

POST INDICATOR VALVE

TREE

DEMOLISH/REMOVE

STORM DRAIN MANHOLE

TREE LINE

WATER GATE VALVE

CONCRETE CURB AND GUTTER

BITUMINOUS CONCRETE PAVEMENT

UNDERGROUND ELECTRIC

SANITARY MANHOLE

ELECTRICAL MANHOLE

SPOT ELEVATION

FENCE

14.5

FIRE HYDRANT

WATER METER

WATER LINE

SANITARY SEWER

STORM SEWER

STORM MANHOLE

NEWEXISTING

BUILDING

CONCRETE PAVEMENT, SIDEWALK OR SLAB

STORM DRAIN INLET

LIGHT POLE

SHRUB

WATER MAHHOLE

UNIDENTIFIED MANHOLE

CONTOURS

SANITARY SEWER CLEANOUTCO

CONCRETE CURB

OR

SIGN

HANDICAP PARKING

CONNECT TO EXISTING

GRAVEL ROAD

SANITARY FORCE MAIN

LIMITS OF CLEARING/DISTURBANCE

WETLANDS LIMITS

THRUST BLOCK

CUT & CAP EXISTING PIPE

OR

FH

RIPRAP CHANNEL

PRECAST UNIT RETAINING WALL

SILT FENCESF

NEWEXISTING

SUPER SILT FENCESSF

STONE OUTLET STRUCTURE

STONE CHECK DAM

TSOS

CD

SWALE/DITCH

STANDARD INLET PROTECTION

RIP-RAP INFLOW PROTECTION

STABILIZED CONSTRUCTION ENTRANCE

SIP

RRP

SCE

PIV

CURB INLET PROTECTION

INLET PROTECTION FOR GRATED INLETS WITH CURB OPENINGS

AT GRADE INLET PROTECTION

CIP

AGIP

MCIP

"ORANGE BLAZE" PLASTIC TREE PROTECTION FENCEOB

LIMIT OF DISTURBANCE

PAVEMENT PATCH

LOD

14.5

EUE

x x

EW

ESD

ES

CONC.

SMH

EFM

LEGEND

WM

W

UMHU

EMH

LP

L/P

W 10"

S 8"

WWM

SSF

SF

CE

CHELTENHAM INDOOR

FIRING RANGE

PROJECT NO.

TRAINING CENTER

FEDERAL LAW ENFORCEMENT

DRAWING FILE

FAC. DWG.

DATE

DRAWN BY CHECKED BY

SHEET

SATISFACTORY TO

OF

CHELTENHAM, MARYLAND

1 2 3 4 5 6

A

B

C

D

E

8-9-02 153

4/

4/

R

E V

IS

E

D F

O R

M D

E C

O M

M E

N

TS

5/

1/

R

E V

IS

E

D A

R E

B A

S E

D O

N M

A R

Y

LA

N D

M D

E C

O M

M E

N

TS

B

C

D

B

C

D

B

C

D

B

C

D

B

C

D

B

C

D

B

C

D

B

C

D

B

C

D

File details come from the government source that posted it. Updated .