7._Attachment_F_-_General_Aviation_Fuel_Farm.pdf

PDF 774 KB Posted

Attached to
Stormwater Treatment Units - Inspection and Maintenance
Solicitation number
280-2992403-CP
Issued by
Orange County, California

About this file

This is an attachment specification document for the County of Orange, John Wayne Airport, detailing the REM Triton CPS (Curb and Patio System) stormwater treatment units installed at the General Aviation Fuel Farm located at 3160 Airway Avenue, Costa Mesa, California. The document provides technical specifications and dimensional data for three standard filter models: the TR20(12)CPS-FTC, TR24(16)CPS-FTC, and TR40(18)CPS-FTC, which are designed to capture stormwater runoff from the fuel farm area. The units feature Type 304 stainless steel construction with 10-gauge inner and outer support bars, 90% recycled ABS caps, and perforated screens with 4.8-millimeter openings providing 51% open area for optimal flow rates. Filtered flow rates range from 19.24 to 42.55 cubic feet per second depending on the model selected, with bypass flow capacities from 1 to 10 cubic feet per second. The document includes photographic evidence of the installed north storm drain inlet with REM Triton filter components.

The REM Triton CPS units are manufactured in the United States and are approved as Full Trash Capture Devices through the California State Water Resource Control Board, meeting applicable state environmental regulations. Notable features include the option for custom sizes and configurations, the capability to house absorbent media without modifications, and the ability to mount multiple units vertically to increase capture capacity. Optional accessories include deflector plates constructed from Type 304 stainless steel perforated sheet or 0.5-inch-thick high-density polyethylene, and contour aprons configured with perforated stainless steel. The units can be elevated within sump-type basins and feature 1-inch-wide cutouts in the bottom cap to prevent standing water accumulation.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DATE: August 5, 2021 John Wayne Airport General Aviation Fuel Farm

3160 Airway Avenue Costa Mesa, CA 92626

Photo 1

General aviation fuel farm north storm drain inlet with REM Triton filter.

Photo 2

Storm drain inlet with REM Triton filter.

Attachment F - General Aviation Fuel Farm

REM TRITON CPS - FTC

Standard size dimensions

Model:

Width:

Height:

Depth/Radius:

Bypass Radius:

Filtered Flow Rate:

Bypass Flow:

TR20(12)CPS-FTC TR24(16)CPS-FTC TR40(18)CPS-FTC

20"

12"

8"

24"

16"

12"

40"

18"

20"

18.54

(CFS)

18"

42.55

(CFS)

9.89

(CFS)

10"

25.65

(CFS)

5.56

(CFS)

6"

19.24

(CFS)

1" Wide X 2" Length Type 304 SS

Mounting Tabs with 5/16" hole for anchoring.

Inner and Outer Support Bars:

Type 304 SS

10 GA. Horizontal and vertical bars.

2" X 2" spacing.

90% Recycled ABS Top and bottom cap. Bottom cap has 1" wide cut outs to prevent standing water.

Type 304 SS U-Channel side supports.

Bypass Overflow

Perforated Screen:

Type 304 SS, with 4.8mm openings.

51% Open Area

Front View

Height

Width

Side View

Depth/Radius

Optional Deflector Plate Simply anchor above CPS unit at the desired height.

Deflector plate can be configured using a Type 304 SS perforated sheet or .5" thick HDPE

Optional Contour Apron Simply attach to the bottom of CPS unit with (3) bolts, before installation.

Contour Apron is configured using a Type 304 SS perforated sheet with 4.8mm openings.

*Anchor to floor where needed.

Notes:

· Units are constructed using a 10 GA. Stainless Steel inner and outer housing support for added structural integrity.

· Perforated Stainless Steel is configured with a 51% Open Area for excellent flow rates comparative to its size.

· CPS Stainless Steel housing and additional attached SS parts are welded.

· Custom sizes and configurations are available.

· Multiple units can be mounted vertically to increase capture capacity.

· CPS unit is capable of housing an absorbent media if ever required, with no retrofitting or modifications needed.

· CPS unit can also be elevated off the basin floor in “Sump” type basins.

· MADE IN THE USA.

*APPROVED Full Trash Capture

Device through the California State Water

Resource Control Board

File details come from the government source that posted it. Updated .