7-8. 696-FD-26-P027 Exhibit 6 Drawings.pdf
PDF 38 MB Posted
- Attached to
- Montford Convert Trusty Camp to Sheltered Beds
- Solicitation number
- 696-FD-26-P027
- Issued by
- Henderson County, Texas
About this file
This document is a set of construction drawings and specifications prepared by Grace Hebert Curtis Architects, LLC for the Texas Department of Criminal Justice (TDCJ), Facilities Division, for the conversion of an existing Trusty Camp to a Sheltered Beds Facility located at 8602 Peach Avenue, Lubbock, Texas 79404. The project, referenced as MWR No. 09023014 and Project No. 696-FD-26-P027, involves comprehensive renovations and improvements to multiple existing buildings including new HVAC systems, plan revisions, a new sally port, and a primary covered walkway connecting the facilities. The construction documents were issued for proposal on March 21, 2025, and encompass architectural, civil, structural, mechanical, electrical, and plumbing disciplines. The project involves the conversion and renovation of Buildings #100 through #900, with specific focus on three primary buildings (Buildings #300, #700, and #900) that will serve as the sheltered beds dormitory areas with associated dining, toilet, and shower facilities. The drawings include comprehensive life safety plans, partition types, exterior elevations, interior details, and full mechanical, electrical, and plumbing systems documentation.
The construction must comply with the 2021 International Building Code, 2021 International Fire Code, 2021 International Plumbing Code, 2021 International Mechanical Code, 2020 National Electrical Code, 2021 International Energy Conservation Code, and 2012 Texas Accessibility Standards/2010 ADA. The project is classified as IIB construction type with an existing building designation under the 2021 International Existing Building Code. The contractor is responsible for all construction sequencing, surveying, quality control, materials testing, traffic control, dust control, erosion control measures, utility coordination, and disposal of all demolition debris and waste materials. All work must be protected from damage during construction, and the contractor must maintain coordination with TDCJ security procedures and obtain approval for any utility shutdowns with a minimum of four days' notice to the owner.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SEAL:
© THIS SET OF DOCUMENTS INCLUSIVE OF
DRAWINGS, SPECIFICATIONS, AND ADDENDUMS MAY
NOT BE COPIED, SCANNED, NOR ELECTRONICALLY
DISTRIBUTED OR USED FOR CONSTRUCTION WITHOUT
THE EXPRESSED WRITTEN CONSENT OF GRACE
HEBERT CURTIS ARCHITECTS, LLC. NO PLAN ROOM,
ELECTRONIC PLAN SERVICE (INTERNET PLAN
SERVICE), NOR REPRODUCTION COMPANY SHALL BE
PERMITTED TO POST THESE DOCUMENTS WITHOUT
THE EXPRESSED WRITTEN CONSENT OF THE
ARCHITECT, GRACE HEBERT CURTIS ARCHITECTS,LLC.
SHEET NUMBER
DATE
PHASE
ISSUED FOR
PROJECT NO.
GRACE HEBERT CURTIS ARCHITECTS, LLC
5/
/2
:1 2:
A
M Au to de sk D oc s:
//5
T D
C J
M on tfo rd
U ni t/M on tfo rd
U ni t - A rc h
M od el .rv t
C O
N
VE
R T
TR
U
ST
Y
C A
M P
TO
SH
EL
TE
R
ED
B
ED
S
FA
C
IL
IT
Y
TE
XA
S D
EP
AR
TM
EN
T O
F C
R
IM
IN
AL
J U
ST
IC
E
P
EA
C
H A
VE
N
U E
LU
BB
O C
K, T
X
G000
COVER SHEET
MWR NO. 09023014
CONSTRUCTION DOCUMENTS
03/21/25
PROPOSAL
CONVERT TRUSTY CAMP TO
SHELTERED BEDS FACILITY
CONSTRUCTION DOCUMENTS
03/21/25
MEPCE
6341 CAMPUS CIRCLE EAST
LAS COLINAS, TEXAS 75063
972-870-9060
MEP ENGINEER
JQ ENGINEERING
100 GLASS STREET
DALLAS, TEXAS 75207
214-623-5835
CIVIL & STRUCTURAL ENGINEER
PROJECT MANAGER: BEN MARSHALL (BMARSHALL@GHC-ARCH.COM)
GRACE HEBERT CURTIS ARCHITECTS, LLC
5000 QUORUM DRIVE, SUITE 500
DALLAS, TEXAS 75254
214-378-9810
ARCHITECT
TEXAS DEPARTMENT OF CRIMINAL JUSTICE: FACILITIES DIVISION
TWO FINANCIAL PLAZA
HUNTSVILLE, TEXAS 77340
OWNER
PROJECT DIRECTORY
PE
AC
H
AV
EN
UE
PROJECT SITE
VICINITY MAP
PROJECT DESCRIPTION
CONVERSION OF EXISTING TRUSTY CAMP BUILDINGS TO SHELTERED BED FACILITY. RENOVATIONS
AND IMPROVEMENTS INCLUDE NEW HVAC, PLAN REVISIONS, NEW SALLY PORT, AND A PRIMARY
COVERED WALKWAY CONNECTING THE FACILTIES.
E SLATON HWY (US 84)E 82ND STREET
PLAN
NORTH
03/21/25
No. Description Date
Exhibit J.6
696-FD-26-P027
OFFICE
DRAWING NAME
A3.2
A7.2
A6.1
ROOM NAME
NUMBER
REVISION
NUMBER
DRAWING NUMBER
DRAWING SCALE
SCALE : 1/4" = 1'-0"
34 KEY NOTE
109'-0"
DRAWING NUMBER
SHEET NUMBER
SHEET NUMBER
DRAWING NUMBER INTERIOR
ELEVATION
DETAIL
4 A4.1
SHEET NUMBER
DRAWING NUMBER
DRAWING NUMBER
SHEET NUMBER
DETAIL SECTION
EXTERIOR
ELEVATION
WALL SECTION
DRAWING NAME
LEVEL LINE
A6.1
DRAWING NUMBER
SHEET NUMBER
A6.1
DRAWING NUMBER
SHEET NUMBER
BUILDING SECTION4
A6.1
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
A.
B.
C.
D.
E.
GENERAL
ARCHITECTURAL DOCUMENTS SHALL BE COORDINATED WITH ALL OTHER
DISCIPLINES’ DOCUMENTS. ANY DISCREPANCY BETWEEN THESE DOCUMENTS
SHOULD BE REPORTED TO THE ARCHITECT FOR CLARIFICATION AND VERIFICATION
PRIOR TO PROCUREMENT OR INSTALLATION OF AFFECTED WORK.
DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE DETAILED. WHERE
SPECIFIC DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE DETERMINED,
CONSULT THE ARCHITECT BEFORE PROCEEDING WITH AFFECTED WORK.
PROTECT ALL MATERIALS, CONSTRUCTION, UTILITIES AND FACILITIES FROM DAMAGE,
INCLUDING BUT NOT LIMITED TO CONSTRUCTION ACTIVITIES, THEFT, MOISTURE, AND
WEATHER. DAMAGED ELEMENTS AND CONDITIONS SHALL BE REPAIRED / REPLACED
AT NO COST TO OWNER.
DO NOT SCALE ANY DRAWINGS IN ANY OF THE DOCUMENTS FOR FIELD LAYOUT.
CONTACT ARCHITECT IF DIMENSIONS ARE NEEDED AND CANNOT BE FOUND IN
WRITING IN THE DOCUMENTS.
INFORMATION ON G SHEETS IS INTENDED TO BE TYPICAL. SOME INFORMATION
SHOWN MAY NOT BE RELEVANT TO PROJECT SPECIFICS. REVIEW THE DOCUMENTS
AND CONFIRM IN WRITING WITH DESIGN TEAM WHICH INFORMATION IS NOT
RELEVANT TO PROJECT SPECIFICS PRIOR TO THE START OF CONSTRUCTION.
REFER TO LEGENDS, SCHEDULES, AND KEYNOTES ON INDIVIDUAL SHEETS FOR
SPECIFIC INFORMATION.
HOLD ALL PIPES, CONDUIT, BRANCH LINES, ETC. AS CLOSE TO THE UNDERSIDE OF
STRUCTURE AS POSSIBLE. USE LOW PROFILE HANGERS WHERE POSSIBLE.
TEMPORARY SHORING AS REQUIRED DURING DEMOLITION AND CONSTRUCTION
SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
PROVIDE ACCESS PANELS AT WALLS AND CEILINGS FOR: FIRE/SMOKE DAMPERS, VAV
BOXES, PLUMBING CLEANOUTS, ELECTRIC HEATERS, AIR HANDLING
UNITS/MECHANICAL EQUIPMENT, VALVES, FILTER BOXES AND OTHER CONCEALED
ITEMS REQUIRING ACCESS. COORDINATE WITH ARCHITECT IN FIELD FOR
INSTALLATION OF ACCESS PANELS WHERE REQUIRED AND NOT GRAPHICALLY
SHOWN ON PLANS.
UNLESS NOTED OTHERWISE DIMENSIONS IN THE DOCUMENTS ARE AS LISTED
BELOW.
DIMENSIONS ARE TAKEN FROM FACE OF GYP OR CENTERLINE OF COLUMN.
"CLEAR" REFERS TO DIMENSION BETWEEN FACES OF FINISH SURFACES.
"EQ" OR "EQUAL" INDICATES DIMENSION TO MATCH ADJACENT. LETTERED
DIMENSIONS (A,B,C,D,ETC.) INDICATE DIMENSION TO MATCH OPPOSITE OR REMOTE
(MATCHING LETTER) DIMENSION.
"+/-" INDICATES APPROXIMATE DIMENSION BASED ON FIELD CONDITION OR
FLEXIBLE DIMENSION THAT CAN BE ADJUSTED.
DIMENSIONS ON REFLECTED CEILING PLANS AND LIGHTING PLANS ARE CLEAR
DIMENSIONS.
1.
2.
3.
4.
5.
DEMOLITION
DURING THE COURSE OF THE WORK ITEMS UNCOVERED THAT VARY FROM WHAT
IS IDENTIFIED IN THE DOCUMENTS SHALL BE IMMEDIATELY BROUGHT TO THE
ATTENTION OF THE ARCHITECT PRIOR TO PROCEEDING WITH AFFECTED WORK.
THIS INCLUDES BUT IS NOT LIMITED TO COMPONENT SIZES, LOCATIONS,
CONFIGURATIONS AND DAMAGED, DETERIORATED, MALFUNCTIONING OR BROKEN
COMPONENTS.
IF NOT SHOWN IN THE DRAWINGS THE CONTRACTOR SHALL REMOVE ALL
EXISTING MATERIALS AND CONSTRUCTION AS NECESSARY TO COMPLETELY
INSTALL ALL NEW WORK AS REQUIRED BY OTHER PARTS OF THE CONTRACT
DOCUMENTS.
LOCATIONS OF TEMPORARY CONSTRUCTION BARRIERS/DUST PARTITIONS TO BE
COORDINATED WITH THE OWNER.
REMOVE ALL CONSTRUCTION DEBRIS AND TRASH DAILY. PROVIDE SEALED
COVERINGS FOR ALL BINS OR BARROWS USED TO REMOVE DEBRIS, MATERIALS
AND TRASH THROUGH OCCUPIED AREAS OF THE BUILDING.
REMOVE ALL EXISTING CONSTRUCTION IN CONFLICT WITH NEW DESIGN.
COORDINATE WITH DESIGN TEAM IF ELEMENTS OF EXISTING CONSTRUCTION
REQUIRED TO BE DEMOLISHED ARE NOT SHOWN ON DEMOLITION PLANS.
6.
7.
8.
9.
10.
11.
12.
13.
UNLESS OTHERWISE NOTED, PARTITIONS TO BE REMOVED FROM FLOOR SLAB TO
UNDERSIDE OF STRUCTURE OR TOP RUNNER AS APPLICABLE.
REMOVAL OF FIXTURES AND EQUIPMENT IS NOT LIMITED TO WHAT IS SHOWN ON
DRAWINGS. IT IS INDICATED FOR GENERAL CONTRACTOR'S INFORMATION ONLY.
PRIOR TO PROPOSAL VERIFY ON JOB FOR EXACT TYPE, LOCATION AND NUMBER
OF ITEMS TO BE REMOVED TO MEET REQUIREMENTS OF PLANS AND
SPECIFICATIONS.
MAINTAIN EXISTING DRIVES AND SERVICE ROAD SERVING THE PREMISES CLEAR
AND AVAILABLE AT ALL TIMES.
THE PORTIONS OF THE FACILITY SURROUNDING THE WORK AREA WILL BE
OCCUPIED AND REMAIN IN OPERATION DURING THE COURSE OF THE WORK.
CONTRACTOR TO COORDINATE SECURITY PROCEDURES WITH CLIENT PRIOR TO
AND THROUGHOUT THE COURSE OF THE WORK.
COORDINATE ANY UTILITY SHUTDOWNS OR INTERRUPTIONS WITH THE OWNER
DURING DEMOLITION AND OTHER PHASES OF THE WORK, SHOW PLANNED UTILITY
INTERRUPTIONS ON THE CONSTRUCTION SCHEDULE, AND PROVIDE 4 DAYS
NOTICE TO THE OWNER BEFORE ANY UTILITY SHUTDOWNS OR INTERRUPTIONS
ARE TO OCCUR.
AT THE INITIATION OF THE WORK AND THROUGH THE COURSE OF THE WORK,
CONTRACTOR SHALL PROVIDE A SECURE PHYSICAL SEPARATION BETWEEN THE
WORK AREA AND THE OTHER AREAS OF THE FACILITY AS SHOWN ON THE
DRAWINGS OR NOTED HEREIN.
CONTRACTOR SHALL NOT STORE OR STAGE CONSTRUCTION MATERIALS IN
AREAS NOT APPROVED BY THE OWNER.
CONTRACTOR SHALL REMOVE ALL CONSTRUCTION DEBRIS AND TRASH DAILY.
PROVIDE SEALED COVERINGS FOR ALL BINS OR BARROWS USED TO REMOVE
DEBRIS, MATERIALS AND TRASH ALONG THE HAULING ROUTE. ALL TRASH
CONTAINERS SHALL BE SEARCHED BY TDCJ SECURITY PRIOR TO LEAVING THE
FACILITY.
1.
1.
2.
3.
4.
FLOOR PLAN:
ALL DOORS TO BE 4 ” FROM FINISH FACE OF ADJACENT PARTITION AS MEASURED
TO OUTSIDE FACE OF DOOR JAMB UNLESS OTHERWISE NOTED.
CEILING PLAN:
CENTER ALL CEILING MOUNTED DEVICES INCLUDING BUT NOT LIMITED TO LIGHT
FIXTURES, EXIT LIGHTS, SPRINKLER HEADS, SPEAKERS IN CEILING TILE PANELS.
CENTER CEILING GRID IN ROOM IN BOTH DIRECTIONS UNLESS INDICATED
OTHERWISE.
ALL LIGHT FIXTURES IN GYPSUM BOARD CEILING SHALL BE CENTERED IN ROOM
UNLESS INDICATED OTHERWISE.
ALL GYPSUM BOARD SOFFITS ARE TO BE FINISHED WITH NO EXPOSED EDGES OR
VIEWS INTO THE PLENUM SPACE.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
ROOF PLAN NOTES:
ALL ROOF DRAINS, OVERFLOW DRAINS AND DOWNSPOUTS TO BE CONNECTED
TO SUBSURFACE DRAINAGE UNLESS NOTED OTHERWISE. SEE CIVIL FOR
CONNECTION OF ROOF DETAINAGE SYSTEM TO UNDERGROUND SERVICES.
ALL ROOF MATERIALS AND ACCESSORIES TO BE INSTALLED IN ACCORDANCE
WITH THE MANUFACTURER’S WRITTEN INSTRUCTIONS, RECOMMENDATIONS,
AND SPECIFICATIONS TO ACHIEVE SPECIFIED WARRANTY AND PROVIDE
WEATHERTIGHT ROOF SYSTEM. (AND NRCA STANDARDS)
COORDINATE ALL ROOF PENETRATIONS AND EQUIPMENT / PLATFORM
SUPPORTS WITH ROOF STRUCTURE AND ROOFING INSTALLATION AND
FLASHING REQUIREMENTS.
ALL ROOF MOUNTED EQUIPMENT STANDS, CURBS, PENETRATOINS,
ACCESSORIES, UTILITIES, ETC. TO BE FLASHED INTO ROOF SYSTEM AS
REQUIRED TO ACHIEVE SPECIFIED WARRANTY.
PACK, SCREEN, INSULATE, AND SEAL ALL ROOF PENETRATION SYSTEMS AS
REQUIRED TO PREVENT ALL OUTSIDE AIR, MOISTURE, ANIMALS, INSECTS, ETC.
FROM COMMUNICATING WITH FRAMING CAVITY BELOW DECK.
DO NOT LOCATE ANY ROOFTOP EQUIPMENT WITHIN 10 ’ OF ROOF EDGE
UNLESS OTHERWISE NOTED.
ALL PIPING, CONDUITS, ETC. SHALL BE A MINIMUM 10 ” ABOVE ROOF SURFACE.
PROVIDE PIPE SUPPORTS AT 8 ’-0” MAX.
AFTER SUBSTANTIAL COMPLETION EXAMINE AND ENSURE ROOF DRAIN LINES
ARE FREE OF DEBRIS AND BLOCKAGE. FLUSH WITH WATER TO ENSURE THAT
DRAINS FLOW FREELY.
ISOLATE ALL HEAT PIPES/FLUES AS RECOMENDED AND OUTLINED IN THE NRCA
MANUAL FOR ISOLATED STACK FLASHING.
ALL ROOFTOP PENETRATIONS (SOIL STACKS, VENTS, ETC.) ARE INSTALLED
MINIMUM 4’-0” FROM OTHER DECK PENETRATIONS, RISE WALLS, AND ROOF
EDGE.
DIMENSIONS, DETAILS, EQUPMENT SIZES AND LOCATIONS SHOWN ON THESE
ROOF PLANS AND DETAILS ARE FOR INFORMATION AND REFERENCE ONLY.
EXACT SIZE AND LOCATIONS TO BE COORDINATED WITH ALL DISCIPLINES.
ALL SHEETMETAL SHALL BE INSTALLED TO COMPLY WITH THE LATEST
EDITION OF SMACNA ’S ARCHITECTURAL MANUAL.
ANCHOR ROOFTOP UNITS SECURELY IN PLACE WITH METHODS INDICATED
PROVIDING FOR THERMAL EXPANSION OF METAL UNITS. CONCEAL
FASTENERS WHERE POSSIBLE AND SET UNITS TRUE TO LINE AND LEVEL.
EXPOSED EDGES SHALL BE FOLDED BACK NEATLY FROM A ½" HEM ON THE
CONCEALED EDGE. INSTALL WORK WITH LAPS, JOINTS AND SEAMS WHICH
WILL BE WATERTIGHT AND WATERPROOF.
A ½" HEM ON THE CONCEALED EDGE. INSTALL WORK WITH LAPS, JOINTS AND
SEAMS WHCIH WILL BE WATERTIGHT AND WATERPROOF.
1.
2.
3.
4.
5.
6.
SITE PLAN NOTES:
SLOPE ALL PAVING AND GRADING AWAY FROM BUILDING TO ACHIEVE POSITIVE
DRAINAGE AND TO MINIMIZE PONDING WATER ON SITE.
IMMEDIATELY NOTIFY DESIGN TEAM IF UNDOCUMENTED UTILTIES ARE
DISCOVERED ON SITE.
ALL EXTERIOR LEVEL LANDINGS SHALL BE OFFSET ½ ” MAXIMUM FROM FINISH
FLOOR, RE: G SHEETS AND SLOPE AWAY FROM THE BUILDING ¼ ” PER FOOT
MAXIMUM.
PROVIDE HOSE STORAGE AT DUMPSTER ENCLOSURES.
PROVIDE WHEEL STOPS AT ALL NEW PARKING SPACES.
RESTORE ALL DAMAGED SIDEWALKS AND CURBS TO THE STANDARDS OF THE
AUTHORITY HAVING JURISDICTION.
11.
12.
13.
14.
15.
ASBESTOS ABATEMENT, LEAD PAINT REMOVAL, AND OTHER HAZARDOUS MATERIAL
REMOVAL IS NOT IN THE CONTRACT. SHOULD THE CONTRACTOR ENCOUNTER THE
PRESENCE, OR POSSIBLE PRESENCE, OF POTENTIALLY HAZARDOUS MATERIALS, THE
CONTRACTOR SHALL NOTIFY THE OWNER FOR INSTRUCTIONS PRIOR TO CONTINUING
WORK.
ALL EXISTING SANITARY SEWER MANHOLE TOPS, WATER VALVE BOXES, METERS,
STORM SEWERS, OR OTHER RELATED APPURTENANCES SHALL BE ADJUSTED TO
FINISH GRADE.
FURNITURE IS FOR REFERENCE ONLY UNLESS OTHERWISE NOTED. REFERNCE
FURNITURE IS NOT IN PROJECT SCOPE.
THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED TEMPORARY
UTILITIES AND TEMPORARY TOILET FACILITIES.
BRAND OR MANUFACTURER'S REFERENCES ARE DESCRI[TIVE ONLY, AND INDICATE
TYPE AND QUALITY TO BE PROVIDED. ALL REFERENCES TO BRAND OR
MANUFACTURER NAMES SHALL BE INTERPRETEDTO INCLUDE THE LANGUAGE "OR A/E
APPROVED EQUAL". ANY BRAND OR MANUFACTURER MEETING SPECIFICATIONS
SHALL BE CONSIDERED FOR APPROVAL, IRRESPECTIVE OF THE LANGUAGE "OR A/E
APPROVED EQUAL" APPEARING IN CONJUNCTION WITH THE BRAND OR
MANUFACTURER'S NAME.
SEAL:
© THIS SET OF DOCUMENTS INCLUSIVE OF
DRAWINGS, SPECIFICATIONS, AND ADDENDUMS MAY
NOT BE COPIED, SCANNED, NOR ELECTRONICALLY
DISTRIBUTED OR USED FOR CONSTRUCTION WITHOUT
THE EXPRESSED WRITTEN CONSENT OF GRACE
HEBERT CURTIS ARCHITECTS, LLC. NO PLAN ROOM,
ELECTRONIC PLAN SERVICE (INTERNET PLAN
SERVICE), NOR REPRODUCTION COMPANY SHALL BE
PERMITTED TO POST THESE DOCUMENTS WITHOUT
THE EXPRESSED WRITTEN CONSENT OF THE
ARCHITECT, GRACE HEBERT CURTIS ARCHITECTS,LLC.
SHEET NUMBER
DATE
PHASE
ISSUED FOR
PROJECT NO.
GRACE HEBERT CURTIS ARCHITECTS, LLC
5/
/2
:1 2:
A
M Au to de sk D oc s:
//5
T D
C J
M on tfo rd
U ni t/M on tfo rd
U ni t - A rc h
M od el .rv t
C O
N
VE
R T
TR
U
ST
Y
C A
M P
TO
SH
EL
TE
R
ED
B
ED
S
FA
C
IL
IT
Y
TE
XA
S D
EP
AR
TM
EN
T O
F C
R
IM
IN
AL
J U
ST
IC
E
P
EA
C
H A
VE
N
U E
LU
BB
O C
K, T
X
G001
DRAWING INDEX +
GENERAL INFORMATION
MWR NO. 09023014
CONSTRUCTION DOCUMENTS
03/21/25
PROPOSAL
AC ACOUSTICAL CEILING TILE
ADAAG AMERICANS WITH DISABILITIES ACT
ADJ ADJUSTABLE
AFF ABOVE FINISHED FLOOR
ALT ALTERNATE
ALUM ALUMINUM
APPROX APPROXIMATE
ARCH ARCHITECT
BB BEAD BOARD (WAINSCOTT)
BD BOARD
BLDG BUILDING
BO BOTTOM OF
BOS BOTTOM OF STEEL
BOT BOTTOM
BUR BUILT UP ROOF
C CARPET OR CARPET TILE
CAB CABINET
CB CATCH BASIN
CC CUBICLE CURTAIN TRACK
CG CORNER GUARD
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CLOS CLOSET
CLR CLEAR
CO CLEAN OUT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CR CRASH RAIL
CRM CROWN MOULDING
CTR CENTER
DBL DOUBLE
DET DETAIL
DF DECORATIVE FILM
DFC DOOR FRAME CASING
DIA DIAMETER
DIM DIMENSION
DM DECORATIVE METALS
DN DOWN
DR DOOR
DS DOWN SPOUT
DW DISHWASHER
DWG DRAWING
E EAST
EA EACH
EF EPOXY FLOORING
EHD ELECTRIC HAND DRYER
EIFS EXTERIOR INSULATED FINISHING SYSTEM
EJ EXPANSION JOINT
ELEC ELECTRIC(AL)
ELEV ELEVATION
EMER EMERGENCY
EQ EQUAL
EQUIP EQUIPMENT
ABBREVIATIONSSYMBOLSDRAWING INDEX
SHEET
NUMBER SHEET NAME CD
IS
SU
E
GENERAL
G000 COVER SHEET ●
G001 DRAWING INDEX + GENERAL INFORMATION ●
G002 PARTITION TYPES ●
G003 TYPICAL PARTITION DETAILS ●
LIFESAFETY
LS.3 LIFE SAFETY PLAN - BUILDING #300 ●
LS.7 LIFE SAFETY PLAN - BUILDING #700 ●
LS.9 LIFE SAFETY PLAN - BUILDING #900 ●
CIVIL
C0.01 GENERAL NOTES ●
C1.00 OVERALL EXISTING CONDITIONS ●
C1.01 DEMOLITION PLAN ●
C2.00 ENGINEERING SITE PLAN ●
C3.00 GRADING PLAN ●
C4.00 EROSION CONTROL PLAN ●
C4.01 EROSION CONTROL DETAIL ●
C5.00 CIVIL DETAILS ●
C5.01 CIVIL DETAILS ●
STRUCTURAL
S0.1 GENERAL NOTES ●
S0.2 GENERAL NOTES ●
S0.3 GENERAL NOTES ●
S1.0 STRUCTURAL SITE PLAN ●
S1.1 FOUNDATION PLAN - AREA A ●
S1.2 FOUNDATION PLAN - AREA B ●
S1.3 FOUNDATION PLAN - AREA C ●
S2.1 ROOF FRAMING PLAN - AREA A ●
S2.2 ROOF FRAMING PLAN - AREA B ●
S2.3 ROOF FRAMING PLAN - AREA C ●
S3.0 TYPICAL FOUNDATION SECTIONS AND SCHEDULES ●
S4.0 TYPICAL STEEL SECTIONS AND SCHEDULES ●
S4.1 TYPICAL STEEL SECTIONS ●
S4.2 STEEL SECTIONS ●
S4.3 STEEL SECTIONS ●
ARCHITECTURAL SITE
AS.1 ARCHITECTURAL SITE PLAN ●
AS.2 FENCE DETAILS ●
ARCHITECTURE DEMOLITION
AD.0 OVERALL DEMOLITION PLAN ●
AD.3 DEMOLITION PLAN - BUILDING #300 ●
AD.4 DEMOLITION PLAN - BUILDING #400 ●
AD.7 DEMOLITION PLAN - BUILDING #700 ●
AD.9 DEMOLITION PLAN - BUILDING #900 ●
ARCHITECTURE
A0.0 OVERALL FLOOR PLAN ●
A1.1 FLOOR PLAN - BUILDING #100 ●
A1.2 FLOOR PLAN - BUILDING #200 ●
A1.3 FLOOR PLAN - BUILDING #300 ●
A1.4 FLOOR PLAN - BUILDING #400 ●
A1.5 FLOOR PLAN - BUILDING #500 ●
A1.7 FLOOR PLAN - BUILDING #700 ●
A1.8 FLOOR PLAN - BUILDING #800 ●
A1.9 FLOOR PLAN - BUILDING #900 ●
A1.13 LARGE-SCALE PLANS ●
A1.19 LARGE-SCALE PLANS ●
A2.1 REFLECTED CEILING PLAN - BUILDING #100 ●
A2.2 REFLECTED CEILING PLAN - BUILDING #200 ●
A2.3 REFLECTED CEILING PLAN - BUILDING #300 ●
A2.4 REFLECTED CEILING PLAN - BUILDING #400 ●
A2.5 REFLECTED CEILING PLAN - BUILDING #500 ●
A2.7 REFLECTED CEILING PLAN - BUILDING #700 ●
A2.8 REFLECTED CEILING PLAN - BUILDING #800 ●
A2.9 REFLECTED CEILING PLAN - BUILDING #900 ●
A3.0 OVERALL ROOF PLAN ●
A4.1 EXTERIOR ELEVATIONS - BUILDING #100 ●
A4.2 EXTERIOR ELEVATIONS - BUILDING #200 ●
A4.3 EXTERIOR ELEVATIONS - BUILDING #300 ●
A4.4 EXTERIOR ELEVATIONS - BUILDING #400 ●
A4.5 EXTERIOR ELEVATIONS - BUILDING #500 ●
A4.7 EXTERIOR ELEVATIONS - BUILDING #700 ●
A4.8 EXTERIOR ELEVATIONS - BUILDING #800 ●
A4.9 EXTERIOR ELEVATIONS - BUILDING #900 ●
A5.0 WALL SECTIONS ●
A6.0 DOOR AND EQUIPMENT SCHEDULES ●
A6.1 DOOR DETAILS ●
INTERIOR DESIGN
I0.0 FINISH KEY AND ROOM FINISH SCHEDULES ●
I0.1 FINISH TRANSITION DETAILS ●
I1.3 FINISH PLAN - BUILDING #300 ●
I1.7 FINISH PLAN - BUILDING #700 ●
I1.9 FINISH PLAN - BUILDING #900 ●
I2.1 INTERIOR ELEVATIONS ●
I2.2 INTERIOR ELEVATIONS ●
I2.3 TYPICAL TOILET & SPECIALTY EQUIPMENT INFORMATION ●
I3.1 INTERIOR DETAILS ●
I3.2 INTERIOR DETAILS ●
MECHANICAL
M0.1 MECHANICAL GENERAL NOTES AND LEGENDS ●
MD.1 MECHANICAL DEMOLITION PLAN ●
MD.2 MECHANICAL DEMOLITION PLAN ●
M1.1 MECHANICAL PLAN - BUILDING #100 ●
M1.2 MECHANICAL PLAN - BUILDING #200 ●
M1.3 MECHANICAL PLAN - BUILDING #300 ●
M1.4 MECHANICAL PLAN - BUILDING #400 ●
M1.5 MECHANICAL PLAN - BUILDING #500 ●
M1.6 MECHANICAL PLAN - BUILDING #600 ●
M1.7 MECHANICAL PLAN - BUILDING #700 ●
M1.8 MECHANICAL PLAN - BUILDING #800 ●
M1.9 MECHANICAL PLAN - BUILDING #900 ●
M5.1 MECHANICAL DETAILS ●
M5.2 MECHANICAL DETAILS ●
M6.1 MECHANICAL SCHEDULES ●
M6.2 MECHANICAL SCHEDULES ●
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXP. JT. EXPANSION JOINT
EXST EXISTING
EXT EXTERIOR
FA FIRE ALARM
FAP FIRE ANNUNCIATOR PANEL
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIN FINISH
FIXT FIXTURE
FLR FLOOR
FLUOR FLORESCENT
FRP FIBERGLASS REINFORCED PLASTIC PANEL
FT FOOT or FEET
GAL GALLON
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GL GLASS
GND GROUND
GWB GYPSUM WALL BOARD
GYP GYPSUM
HC HANDICAPPED
HDWD HARDWOOD
HDWR HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HIGH POINT
HR HAND RAIL
HT HEIGHT
HW HAND WASH
HWH HOT WATER HEATER
ID INNER (OR INSIDE) DIAMETER
INSUL INSULATION
INT INTERIOR
JAN JANITOR
JC JANITOR'S CLOSET
JT JOINT
KP KICK PLATE
LAM LAMINATE
LAV LAVATORY
LB(S) POUNDS
LDG LANDING
LF LINOLEUM FLOORING
LT LIGHT
LVT LUXURY VINYL TILE
LWC LINEAR WOOD CEILING
M MISCELLANEOUS
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MFR MANUFACTURER
MI MIRROR
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTD MOUNTED
MTL METAL
N NORTH
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OFF OFFICE
OH OPPOSITE HAND
OP OVERFLOW PIPE
OPG OPENING
OPP OPPOSITE
P PAINT
PC PRIVACY CURTAIN
PCN PAINTED CONCRETE
PL PLASTIC LAMINATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLYWD PLYWOOD
PR PAIR
QS QUARTZ SURFACE
R RISER
RAD RADIUS
RB RUBBER WALL BASE
RBM RUBBER WALL BASE MILWORK PROFILE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RE REFER
REF REFRIGERATOR
REFL REFLECTIVE
REINF REINFORCED
REQD REQUIRED
RESIL RESILIENT
RF RUBBER FLOORING
RM ROOM
RO ROUGH OPENING
RP RESIN PANEL
RR RUB RAIL
S SOUTH
SC SCUPPER
SC SEALED CONCRETE
SCHED SCHEDULE
SDT STATIC DISSIPATIVE FLOORING
SECT SECTION
SF SQUARE FOOT
SF SEAMLESS FLOORING
SHT SHEET
SIM SIMILAR
SPEC SPECIFICATION
SQ SQUARE
SS STAINLESS STEEL
SSM SOLID SURFACE MATERIAL
ST STONE
STD STANDARD
STL STEEL
STRUCT STRUCTURAL
SURF SURFACE
SUSP SUSPENDED
SV SHEET VINYL
SWP SPECIALTY WALL PANELS
T TREAD
T TRANSITION STRIP
T&G TONGUE & GROOVE
TEL TELEPHONE
THK THICK
TL TILE
TLT TOILET
TO TOP OF
TOS TOP OF STEEL
TP TOILET PARTITION
TR TRIM
TS TACKABLE SURFACE
TYP TYPICAL
TZ TERRAZZO
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
UTIL UTILITY
VCF VINYL COMPOSITION FLOORING
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VIF VERIFY IN FIELD
VOJ VERIFY ON JOB
VTR VENT TERMINATION PIPE
W WEST
W/ WITH
W/O WITHOUT
WB WOOD BASE
WC WALL COVERING
WC WATERCLOSET
WD WOOD
WIN WINDOW
WP WATERPROOF
WP WALL PROTECTION
WS WOOD STAIN
WT WEIGHT
WT WINDOW TREATMENTS
WV WOOD VENEER
WWF WELDED WIRE FABRIC
GENERAL NOTES
EQUIPMENT MATRIX
SECURITY CAMERAS & COMMUNICATIONS OF/OI
EQUIPMENT RESPONSIBILITY
CUBICLES OF/OI
SHOWER UNITS (SS) W/ FOLDING SHOWER SEAT,
CONTROLS, SHOWER HEAD AND SHOWER WAND
OF/OI
URINALS (SS) W/ FLUSH VALVE OF/OI
SHOWER PARTITIONS AND DOORS (SS)
STEAM TABLE (FUTURE)
ICE MACHINE (FUTURE)
DINING SEATING
DINING TABLES
TABLES
SHEET
NUMBER SHEET NAME CD
IS
SU
E
ELECTRICAL
E0.01 ELECTRICAL GENERAL NOTES AND LEGEND ●
E1.00 ELECTRICAL SITE DEMO PLAN ●
E1.01 ELECTRICAL SITE PLAN ●
E1.03 ELECTRICAL DEMOLITION PLAN - BUILDING #300 ●
E1.07 ELECTRICAL DEMOLITION PLAN - BUILDING #700 ●
E1.09 ELECTRICAL DEMOLITION PLAN - BUILDING #900 ●
E2.01 ELECTRICAL POWER PLAN -BUILDING #100 ●
E2.02 ELECTRICAL POWER PLAN -BUILDING #200 ●
E2.03 ELECTRICAL POWER PLAN -BUILDING #300 ●
E2.04 ELECTRICAL POWER PLAN -BUILDING #400 ●
E2.05 ELECTRICAL POWER PLAN -BUILDING #500 ●
E2.07 ELECTRICAL POWER PLAN -BUILDING #700 ●
E2.08 ELECTRICAL POWER PLAN -BUILDING #800 ●
E2.09 ELECTRICAL POWER PLAN -BUILDING #900 ●
E3.03 ELECTRICAL LIGHTING PLAN -BUILDING #300 ●
E3.07 ELECTRICAL LIGHTING PLAN -BUILDING #700 ●
E3.09 ELECTRICAL LIGHTING PLAN -BUILDING #900 ●
E5.01 ELECTRICAL DETAILS ●
E6.01 ELECTRICAL SCHEDULES ●
E6.02 ELECTRICAL SCHEDULES ●
E6.03 ELECTRICAL SCHEDULES ●
E6.04 ELECTRICAL SCHEDULES ●
E6.05 ELECTRICAL SCHEDULES ●
E6.06 ELECTRICAL SCHEDULES ●
E6.07 ELECTRICAL SCHEDULES ●
E6.08 ELECTRICAL SCHEDULES ●
E6.09 ELECTRICAL SCHEDULES ●
E6.10 ELECTRICAL SCHEDULES ●
E6.11 ELECTRICAL SCHEDULES ●
E7.01 ELECTRICAL DIAGRAMS ●
PLUMBING
P0.0 PLUMBING GENERAL NOTES AND LEGEND ●
P0.1 DEMOLITION SITE PLAN - PLUMBING ●
P0.2 SITE PLAN - PLUMBING ●
P1.1 PLUMBING DEMOLITION PLAN - BUILDING #100 ●
P1.2 PLUMBING DEMOLITION PLAN - BUILDING #200 ●
P1.3 PLUMBING DEMOLITION PLAN - BUILDING #300 ●
P1.4 PLUMBING DEMOLITION PLAN - BUILDING #400 ●
P1.5 PLUMBING DEMOLITION PLAN - BUILDING #500 ●
P1.7 PLUMBING DEMOLITION PLAN - BUILDING #700 ●
P1.8 PLUMBING DEMOLITION PLAN - BUILDING #800 ●
P1.9 PLUMBING DEMOLITION PLAN - BUILDING #900 ●
P2.3 PLUMBING UNDERSLAB PLAN -BUILDING #300 ●
P2.7 PLUMBING UNDERSLAB PLAN -BUILDING #700 ●
P2.9 PLUMBING UNDERSLAB PLAN -BUILDING #900 ●
P3.3 PLUMBING WASTE AND VENT PLAN -BUILDING #300 ●
P3.7 PLUMBING WASTE AND VENT PLAN -BUILDING #700 ●
P3.9 PLUMBING WASTE AND VENT PLAN -BUILDING #900 ●
P4.1 PLUMBING SUPPLY PLAN -BUILDING #100 ●
P4.2 PLUMBING SUPPLY PLAN -BUILDING #200 ●
P4.3 PLUMBING SUPPLY PLAN -BUILDING #300 ●
P4.4 PLUMBING SUPPLY PLAN -BUILDING #400 ●
P4.5 PLUMBING SUPPLY PLAN -BUILDING #500 ●
P4.7 PLUMBING SUPPLY PLAN -BUILDING #700 ●
P4.8 PLUMBING SUPPLY PLAN -BUILDING #800 ●
P4.9 PLUMBING SUPPLY PLAN -BUILDING #900 ●
P5.1 PLUMBING DETAILS ●
P5.2 PLUMBING DETAILS ●
P5.3 PLUMBING DETAILS ●
P6.1 PLUMBING SCHEDULES ●
P6.2 PLUMBING SCHEDULES ●
P7.1 PLUMBING RISERS ●
P7.2 PLUMBING RISERS ●
P7.3 PLUMBING GAS RISERS ●
P7.4 PLUMBING GAS RISERS ●
EQUIPMENT MATRIX NOTES:
CF/CI = CONTRACTOR FURNISHED / CONTRACTOR INSTALLED
OF/OI = OWNER FURNISHED / OWNER INSTALLED
LAVATORIES (SS) W/ CONTROL VALVES OF/OI
MIRRORS (SS) OVER LAVATORIES OF/OI
SIDE AND REAR GRAB BARS (SS) OF/OI
WATER CLOSETS (SS) COMPLETE W/ FLUSH VALVE OF/OI
TOILET PAPER DISPENSER (SS) OF/OI
TOILET PARTITIONS AND DOORS (SS) OF/OI
OF/OI
OF/OI
OF/OI
OF/OI
OF/OI
OF/OI
MOP SINK (SS) OF/OI
HAND SINK (ROOM 927) CF/CI
WATER CLOSETS COMPLETE W/ FLUSH VALVE
(ROOMS 906, 920, & 921 ONLY)
CF/CI
LAVATORIES W/ CONTROL VALVES
(ROOMS 906, 920, & 921 ONLY)
CF/CI
COUNTERTOP SINKS (SS) W/ CONTROL VALVES OF/OI
UTILITY SINK (ROOMS 302 & 702) CF/CI
03/21/25
SIDE AND REAR GRAB BARS (SS)
(ONLY IN ROOMS 906, 920, & 921)
CF/CI
MIRRORS (SS) OVER LAVATORIES
(ROOMS 906, 920, & 921 ONLY)
CF/CI
TOILET PAPER DISPENSER (SS)
(ROOMS 906, 920, & 921 ONLY)
CF/CI
DRINKING FOUNTAINS OF/OI
WIRE PARTITIONS
SECURITY FENCING AND GATES
OF/OI
OF/OI
No. Description Date
TYPE 'H'
CONT. METAL SLOTTED
DEFLECTION TRACK, ATTACHED TO
BOTTOM OF STRUCTURE
SOUND ATTENUATION
BLANKETS AT SOUND
ATTENUATION WALLS
CEILING RE: REFLECTED
CEILING PLAN
DECK
RE: STRUCTURAL
ACOUSTICAL SEALANT AT
SOUND ATTENUATED WALLS
MINERAL WOOL INSULATION
CONT. SEALANT AT SLAB
BASE, RE: FINISH KEY & FINISH
PLAN
IMPACT RESISTANT GYP
BOARD, ONE SIDE
REFER TO INTERIOR FINISH
SHEETS FOR ADDITIONAL FINISH
MATERIALS
ROOM
SIDE
AT
F
LO
OR
SE
CT
IO
N
VI
EW
PL
AN
AT
C
EI
LIN
G
SE
CT
IO
N
AT
T
OP
SE
CT
IO
N
"H4" "H4s"4" MTL STUDS
W/ SOUND ATTENUATION
4" MTL STUDS
BASE PARTITION
ACOUSTICAL SEALANT AT
SOUND ATTENUATED WALLS;
FIRE RATED SEALANT AT
RATED WALLS
CEILING RE: REFLECTED
CEILING PLAN
TYPE 'K'
AT
F
LO
OR
SE
CT
IO
N
VI
EW
PL
AN
AT
C
EI
LIN
G
SE
CT
IO
N
AT
T
OP
SE
CT
IO
N
GROUTING AND REINFORCING, RE:
STRUCTURAL
"K4" "K6" "K8"
4" CMU BLOCK
6" CMU BLOCK
8" CMU BLOCK
BASE PARTITION
2'- 3"
2'- 1"
2'- 1 3
/4" 2'-
9 3 /4"
CONT. METAL SLOTTED
DEFLECTION TRACK, ATTACHED TO
BOTTOM OF STRUCTURE
"A4" "A8"
COMPOSITE, NON-RATED PARTITION
(TO UNDERSIDE OF STRUCTURE)
SOUND ATTENUATION
BLANKETS AT SOUND
ATTENUATION WALLS
4" MTL STUDS
8" MTL STUDS
W/ SOUND ATTENUATION
TYPE 'A'
CEILING RE: REFLECTED
CEILING PLAN
IMPACT RESISTANT GYP
BOARD TO STRUCTURE,
BOTH SIDES
DECK
RE: STRUCTURAL
ACOUSTICAL SEALANT AT
SOUND ATTENUATED WALLS
MINERAL WOOL INSULATION
CONT. SEALANT AT SLAB
BASE, RE: FINISH KEY & FINISH
PLAN
REFER TO INTERIOR FINISH
SHEETS FOR ADDITIONAL FINISH
MATERIALS
AT
F
LO
OR
SE
CT
IO
N
VI
EW
PL
AN
AT
C
EI
LIN
G
SE
CT
IO
N
AT
T
OP
SE
CT
IO
N
1'- 4"
"A4s" "A8s"
4" MTL STUDS
8" MTL STUDS
BASE PARTITION
MI
N6"
MTL STUD BRACING @
48" O.C. MAX, VERIFY W/
STUD MFG TO VERIFY
LIMITING HEIGHT
NON-COMPOSITE, BRACED @ 48" O.C. NON-
RATED PARTITION
TYPE 'D'
CEILING RE: REFLECTED
CEILING PLAN
CONT. SEALANT AT SLAB
BASE, RE: FINISH KEY & FINISH
PLAN
SOUND ATTENUATION
BLANKETS AT SOUND
ATTENUATION WALLS
IMPACT RESISTANT GYP
BOARD, BOTH SIDES
REFER TO INTERIOR FINISH
SHEETS FOR ADDITIONAL FINISH
MATERIALS
AT
F
LO
OR
SE
CT
IO
N
VI
EW
PL
AN
AT
C
EI
LIN
G
SE
CT
IO
N
AT
T
OP
SE
CT
IO
N
SOUND ATTENUATION
BLANKETS AT SOUND
ATTENUATION WALLS
36"MIN.
S.A.BLANKETS
36" MIN.
S.A.BLANKETS
"D4" "D8"
4" MTL STUDS
8" MTL STUDS
W/ SOUND ATTENUATION
"D4s" "D8s"
4" MTL STUDS
8" MTL STUDS
BASE PARTITION
MTL STUD BRACING @
48" O.C. MAX, VERIFY W/
STUD MFG TO VERIFY
LIMITING HEIGHT
MI
N6"
NON-COMPOSITE, BRACED @ 48" O.C. NON-RATED PARTITION. GYP
ONE SIDE.
TYPE 'E'
CEILING RE: REFLECTED
CEILING PLAN
CONT. SEALANT AT SLAB
BASE, RE: FINISH KEY & FINISH
PLAN
SOUND ATTENUATION
BLANKETS AT SOUND
ATTENUATION WALLS
IMPACT RESISTANT GYP
BOARD, ONE SIDE
REFER TO INTERIOR FINISH
SHEETS FOR ADDITIONAL FINISH
MATERIALS
ROOM SIDE
AT
F
LO
OR
SE
CT
IO
N
VI
EW
PL
AN
AT
C
EI
LIN
G
SE
CT
IO
N
AT
T
OP
SE
CT
IO
N
SOUND ATTENUATION
BLANKETS AT SOUND
ATTENUATION WALLS
36"MIN.
S.A.BLANKETS
"E4" 4" MTL STUDS
W/ SOUND ATTENUATION
"E4s" 4" MTL STUDS
BASE PARTITION
1.
2.
3.
4.
5.
6.
7.
8.
9.
A.
B.
NOT ALL PARTITION TYPES SHOWN ON THIS SHEET MAY BE USED IN PROJECT.
REFER TO PLANS FOR ACTUAL PARTITION TYPES USED.
ALL PARTITION TYPES TO BE "A4" UNLESS NOTED OTHER WISE.
REFER TO PLANS AND WALL PARTITION LEGEND FOR RATED PARTITIONS.
ALL RATED PARTITIONS SHALL BE CONSTRUCTED FIRST, IN ORDER OF PRIORITY (SEE
WALL / PARTITION PRIORITY LEGEND BELOW). SECONDARY PARTITIONS TO ABUT
BUT NOT PENETRATE RATED WALLS AS SHOWN IN WALL ABUTMENT DETAIL ON
TYPICAL PARTITION DETAILS SHEET.
WHERE PARTITION TYPE INDICATES GYP. BD. TO BTM. OF DECK, STOP GYP. BD. 1/2"
BELOW LINE OF STRUCTURE AND SEAL.
IF A FIRE RATED PARTITION OCCURS UNDER A STRUCTURAL MEMBER (OR OTHER
OBSTRUCTION), IT IS THE CONTRACTORS RESPONSIBILITY TO CONTINUE THE FIRE
RATING OF THE PARTITION TO THE UNDERSIDE OF THE ROOF AND/OR FLOOR DECK.
SEAL ALL PENETRATIONS (DUCTS, CONDUITS, STRUCTURE, ETC.) THROUGH
ACOUSTIC AND FIRE RATED ASSEMBLIES IN CONFORMANCE WITH THE U.L. DESIGN
TYPE, THE STC RATING, APPLICABLE FIRE CODES, AND APPLICABLE LOCAL CODES.
BASE PROFILES DEPICTED IN WALL TYPES ARE DIAGRAMMATIC, CONTRACTOR TO
REFER TO FINISH KEY AND ENLARGED BASE DETAILS FOR MATERIALS,
CONSTRUCTION AND PLACEMENT.
REFER TO SPECIFICATIONS FOR METAL STUD GAUGE, SPACING, BRACING AND
DEFLECTION REQUIREMENTS.
ACOUSTICAL NOTES:
PARTITIONS INDICATED IN PLAN WITH PARTITION TAG TO BE INSTALLED W/ S.A.B
(SOUND ATTENUATION BLANKETS) AS INDICATED IN PARTITION TYPE. ADD
ACOUSTICAL SEALANT AT TOPS AND BOTTOMS OF WALLS, AND AT PENETRATIONS
TO MAINTAIN STC RATING OF PARTITION TYPE.
PROVIDE 2 STUDS BETWEEN PENETRATIONS (OUTLETS) ON OPPOSITE SIDES OF
PARTITIONS INDICATED TO ACHIEVE AN STC RATING. SEAL PERIMETER OF EACH
OUTLET WITH ACOUSTICAL SEALANT AND SEAL BACK OF OUTLET BOX WITH
OUTLET BOX PADS. REFER TO G SHEETS FOR DETAILS.
GENERAL PARTITION NOTES
WALL PARTITION / PRIORITY LEGEND
PRIORITY ORDER OF CONSTRUCTION
TWO HOUR FIRE /SMOKE BARRIER
TWO HOUR FIRE RATED BARRIER
ONE HOUR FIRE/SMOKE BARRIER
ONE HOUR FIRE RATED BARRIER
SMOKE PARTITION
NON RATED PARTITION
HIGHEST
LOWEST
**REFER TO WALL ABUTMENT DETAIL AND PARTITIONS @ EXTERIOR WALLS DETAILS ON
TYPICAL PARTITION DETAILS SHEET FOR ADDITIONAL INFORMATION
A6s
STUD SIZE
PARTITION TYPE
SOUND
ATTENUATION
(WHERE
APPLICABLE)
TYPICAL PARTITION TAG
CONT. METAL SLOTTED
DEFLECTION TRACK, ATTACHED TO
BOTTOM OF STRUCTURE
"L4" "L8"
COMPOSITE, NON-RATED PARTITION
(TO UNDERSIDE OF STRUCTURE)
SOUND ATTENUATION
BLANKETS AT SOUND
ATTENUATION WALLS
4" x 16 GA MTL STUDS 8" x 16 GA MTL STUDS
W/ SOUND ATTENUATION
TYPE 'L'
CEILING RE: REFLECTED
CEILING PLAN
IMPACT RESISTANT GYP
BOARD TO STRUCTURE,
BOTH SIDES
DECK
RE: STRUCTURAL
ACOUSTICAL SEALANT AT
SOUND ATTENUATED WALLS
MINERAL WOOL INSULATION
CONT. SEALANT AT SLAB
BASE, RE: FINISH KEY & FINISH
PLAN
REFER TO INTERIOR FINISH
SHEETS FOR ADDITIONAL FINISH
MATERIALS
AT
F
LO
OR
SE
CT
IO
N
VI
EW
PL
AN
AT
C
EI
LIN
G
SE
CT
IO
N
AT
T
OP
SE
CT
IO
N
1'- 4"
"L4s" "L8s"
4" x 16 GA MTL STUDS 8" x 16 GA MTL STUDS
BASE PARTITION
14 GA SHEET STEEL
ATTACHED TO STUDS,
BOTH SIDES
TYPE 'M'
CONT. METAL SLOTTED
DEFLECTION TRACK, ATTACHED TO
BOTTOM OF STRUCTURE
SOUND ATTENUATION
BLANKETS AT SOUND
ATTENUATION WALLS
CEILING RE: REFLECTED
CEILING PLAN
DECK
RE: STRUCTURAL
ACOUSTICAL SEALANT AT
SOUND ATTENUATED WALLS
MINERAL WOOL INSULATION
CONT. SEALANT AT SLAB
BASE, RE: FINISH KEY & FINISH
PLAN
IMPACT RESISTANT GYP
BOARD, ONE SIDE
REFER TO INTERIOR FINISH
SHEETS FOR ADDITIONAL FINISH
MATERIALS
ROOM
SIDE
AT
F
LO
OR
SE
CT
IO
N
VI
EW
PL
AN
AT
C
EI
LIN
G
SE
CT
IO
N
AT
T
OP
SE
CT
IO
N
"M4" "M4s"4" MTL STUDS
W/ SOUND ATTENUATION
4" MTL STUDS
BASE PARTITION
14 GA SHEET STEEL
ATTACHED TO STUDS,
BOTH SIDES
TYPE 'N'
5'- 4"
"N4" "N6" "N8"
4" CMU BLOCK
6" CMU BLOCK
8" CMU BLOCK
BASE PARTITION
GROUTING AND REINFORCING, RE:
STRUCTURAL
SEAL:
© THIS SET OF DOCUMENTS INCLUSIVE OF
DRAWINGS, SPECIFICATIONS, AND ADDENDUMS MAY
NOT BE COPIED, SCANNED, NOR ELECTRONICALLY
DISTRIBUTED OR USED FOR CONSTRUCTION WITHOUT
THE EXPRESSED WRITTEN CONSENT OF GRACE
HEBERT CURTIS ARCHITECTS, LLC. NO PLAN ROOM,
ELECTRONIC PLAN SERVICE (INTERNET PLAN
SERVICE), NOR REPRODUCTION COMPANY SHALL BE
PERMITTED TO POST THESE DOCUMENTS WITHOUT
THE EXPRESSED WRITTEN CONSENT OF THE
ARCHITECT, GRACE HEBERT CURTIS ARCHITECTS,LLC.
SHEET NUMBER
DATE
PHASE
ISSUED FOR
PROJECT NO.
GRACE HEBERT CURTIS ARCHITECTS, LLC
5/
/2
:1 2:
A
M Au to de sk D oc s:
//5
T D
C J
M on tfo rd
U ni t/M on tfo rd
U ni t - A rc h
M od el .rv t
C O
N
VE
R T
TR
U
ST
Y
C A
M P
TO
SH
EL
TE
R
ED
B
ED
S
FA
C
IL
IT
Y
TE
XA
S D
EP
AR
TM
EN
T O
F C
R
IM
IN
AL
J U
ST
IC
E
P
EA
C
H A
VE
N
U E
LU
BB
O C
K, T
X
G002
PARTITION TYPES
MWR NO. 09023014
CONSTRUCTION DOCUMENTS
03/21/25
PROPOSAL
03/21/25
No. Description Date
30'-0" OC MAX30'-0" OC MAX
30'-0" OC MAX30'-0" OC MAX 30'-0" OC MAX30'-0" OC MAX
IN ALL RATED PARTITIONS AND SMOKE PARTITIONS, THE SURFACE AREA OF INDIVIDUAL METALLIC OUTLET OR SWITCH BOXES SHALL NOT EXCEED 16 SQUARE INCHES. THE AGGREGATE SURFACE AREA OF THE BOXES SHALL NOT EXCEED 100 SQUARE INCHES PER 100 SQUARE FEET. BOXES WHICH EXCEED THESE STANDARDS SHALL BE RECESSED AS SHOWN IN "RECESSED EQUIPMENT, BOXES AND DEVICES" DETAIL. BOXES LOCATED ON OPPOSITE SIDES OF RATED AND / OR SMOKE PARTITIONS SHALL BE SEPARATED BY HORIZONTAL DISTANCE OF 24 INCHES
MINIMUM.
ACOUSTICAL SEALANT BACK AND SIDES OF BOX AS
NECESSARY FOR SOUND RATING
TELEPHONE, ELECTRICAL
BOXES, ETC MAX 16 SQ IN
OPENING IN RATED OR SMOKE
WALL SEAL BOXES TIGHT TO
GYP BD WITH ACOUSTICAL
SEALANT (1/4" MAX JOINT
BETWEEN BOX AND ALL
LAYERS OF GYP BD)
ADJACENT ELECTRICAL BOXES
SHALLOW FIRE SIDE BOX DETAIL
NOTE:
REQUIRED WHERE BOX EXCEEDS 16 SQ IN OR
AGGREGATE OF BOXES EXCEEDS 100 SQ IN / 100 SF OF
WALL AREA
LAMINATE BACK PIECE TO
WALLBOARD
2'-0" MIN SPACING
W
AL
L T
YP
E
RE
FE
R
TO
"A" RATED WALL
REFER TO PARTITION TYPES FOR
WALL CONSTRUCTION
TAPE, FINISH AND SEAL ALL
PENETRATIONS IN GYP BOARD
BEHIND CABINET
VA
RI
ES
NOTE:
PROVIDE GYP BD CONTROL JOINTS AT 30'-0"
OC MAX EACH DIRECTION.
REFER TO PARTITION TYPES FOR TYPICAL
WALL CONSTRUCTION.
PROVIDE CONTROL JOINTS AT BOTH SIDES
OF DOOR FRAME TYPICAL UNO.GYP BD CONTROL
JOINT - TYP EA. SIDE
2 LAYERS
5/8" GYP BD
FIRESAFING
NON-RATED PARTITION
OPTION 1
ONE-HOUR RATED PARTITION
OPTION 2
ONE-HOUR RATED PARTITION
1/2"
1/2"1/2"
GYP BD CONTROL
JOINT - TYP EA. SIDE
NON-RATED WALL ASSEMBLY -
REF TO PARTITION TYPES FOR
WALL CONSTRUCTION
GYP BD
BATT
INSULATION
TAPE AND JOINT COMPOUND
STEEL STUDS - REF
STRUCTURAL
EXTERIOR SHEATHING AS
SPECIFIED
EXTERIOR WALL ASSEMBLY -
VARIES, REF PLAN AND WALL
SECTIONS FOR ACTUAL
CONSTRUCTION
GYP BD PATCH - BUTTER ENTIRE
BACK SIDE OF SURFACE. DO NOT
REMOVE JOINT COMPOUND
DISPLACED AT EDGES
CUT OPENING TO WITHIN 1/4" OF
PENETRATION AND SEAL WITH JOINT
COMPOUND
TYPE "S" SCREWS FASTENED TO
STUD - MIN 2 SCREWS PER SECTION
MI
N
2 2
/25 6"
MI
N3"
MI
N
2 2
/25 6"
MI
N3"
MIN
3"
OPENINGS UNDER 3"
1.
2.
3.
4.
5.
NOTES:
IF ANY PIPES ARE TO BE INSULATED, DO NOT RUN INSULATION THROUGH A RATED AND/OR SMOKE
WALL. AFTER PACKING GAP AROUND PIPE THROUGH THE WALL WITH SAFING INSULATION AND
DRYWALL MUD, FLARE INSULATION ONTO FACE OF WALL AROUND PIPE ON BOTH SIDES OF WALL, AND
SEAL TO FACE OF WALL WITH INSULATION MASTIC.
ONLY ONE (1) LAYER ON EACH SIDE OF WALL REQUIRED FOR 1 OR 2 HOUR WALLS. BLOW-OUT PATCH IS
NOT ACCEPTABLE ON WALLS RATED AT 3 OR 4 HOURS.
BUTTER ENTIRE BACK SIDE OF PATCH WITH JOINT COMPOUND.
LEAVE ALL SCREWS EXPOSED.
PATCHES SHALL BE TYPE "X" GYP IN THE SAME THICKNESS USED FOR WALL CONSTRUCTION.
CENTERLINE OF
STUD
3"
UN
DE
R
TAPE AND BED
GYP BD
GYP BD PATCH - CUT GYP BD
OPENING TO STUD ON EITHER SIDE
OF PENETRATION AND SECURE
PATCH TO STUDS W/ 3" MIN
OVERLAP. TAPE AND BED TO EXIST
GYP BD
CUT OPENING TO WITHIN 1/4" OF
PENETRATION AND SEAL WITH JOINT
COMPOUND
TYPE "S" SCREWS FASTENED TO
STUD - MIN 2 SCREWS PER SECTION
MI
N
3 3 /25
6"
MI
N3"
MI
N 3 3
/25 6"
MI
N3"
MIN
3"
OPENINGS OVER 3"
CENTERLINE OF
STUD
OV
ER
3"
SECTION
RUNNER CHANNELS, TYP
UNSLEEVED PENETRATIONS
WIRE PENETRATIONS
PLASTIC UP TO 2"
PIPE OR CONDUIT
TYPICAL SEAL
FOR PIPES AND CONDUITS NOT SUBJECT TO
MOVEMENT OR CONDENSATION
UNSLEEVED WIRE UP TO A 2" BUNDLE
SECURE
ACOUSTIC CAULK
1/2" MAX (PROVIDE SAFING INSUL. IF OVER 1/2")
TYPICAL FIRE-RATED SEAL
CONDUIT FOR BUNDLED WIRES OVER 2"
SLEEVES SHALL BE SECURED IN THE WALL
TO PREVENT MOVEMENT
FIRE AND/OR SMOKE WALL PENETRATIONS
PLASTER, DRYWALL, CONCRETE, OR MASONRY
TYPICAL SEALS AS FOLLOWS:
LESS THAN 1/2" - ACOUSTIC CAULK OR DRYWALL
JOINT COMPOUND (NOT TAPE)
MORE THAN 1/2" - BLOW-OUT PATCH OR
PROPRIETARY SYSTEM
SLEEVED PENETRATIONS
SAFING FOR PIPING NOT SUBJECT TO
CONDENSATION OR FOAMGLASS IN SLEEVE OR
FIBERGLASS WITH PROPRIETARY SYSTEM FOR
PIPING SUBJECT TO CONDENSATION
MIN 20 GA GALV SLEEVE - SECURE IN WALL
INSULATION WHERE APPLICABLE
TYPICAL SEAL
PROPRIETARY SYSTEMS
FOR PIPES AND CONDUITS SUBJECT TO VIBRATION, EXPANSION,
CONTRACTION, AND/OR CONDENSATION
15/16" 15/16"
RATED AND/OR SMOKE WALL
ASSEMBLY - REF TO PARTITION
TYPES FOR WALL CONSTRUCTION
REFER TO WALL
SECTIONS AND
DETAILS FOR
WALL MATERIALS
SEAL ANY PENETRATIONS THRU
RATED AND/OR SMOKE WALL
PER PENETRATION DETAILS
TAPE AND JOINT COMPOUND
STEEL STUDS - REF
STRUCTURAL
EXTERIOR SHEATHING AS
SPECIFIED
EXTERIOR WALL ASSEMBLY - VARIES, REF
PLAN AND WALL SECTIONS FOR ACTUAL
CONSTRUCTION
EXTEND RATED AND/OR
SMOKE WALL INTO
OVERHANG ABOVE AND/OR
INTO SILL BELOW AND SEAL
ALL PENETRATIONS PER
PENETRATION DETAILS
2-
HR
R
AT
ED
W
AL
L
1-HR RATED FLOOR
1-
HR
R
AT
ED
W
AL
L
2-HR RATED FLOOR
NO
N-
RA
TE
D W
AL
L
RATED FLOOR
22 GA. MTL SLEEVE, STUD BLOCKING
WHERE REQ. TO HOLD SLEEVE.
TERMINATE SLEEVE FLUSH WITH FACES
OF WALL
PENETRATING DUCT, PIPE, OR CONDUIT
TY
P
1/2
1"
AL
L S
ID
ES
FILL SPACE WITH RATED MINERAL
FIBER, RECESSED INTO SLEEVE 1/2"
U.N.O BY THE SPECIFIC U.L. SYSTEM
FOR THE REQ. SEALANT THICKNESS
SEAL RECESS WITH NON-HARDENING
SEALANT, BOTH SIDES OF WALL TYP.
RE: SPECIFICATIONS FOR ACOUSTICAL AND
FIRE RATED SEALANT
SEAL:
© THIS SET OF DOCUMENTS INCLUSIVE OF
DRAWINGS, SPECIFICATIONS, AND ADDENDUMS MAY
NOT BE COPIED, SCANNED, NOR ELECTRONICALLY
DISTRIBUTED OR USED FOR CONSTRUCTION WITHOUT
THE EXPRESSED WRITTEN CONSENT OF GRACE
HEBERT CURTIS ARCHITECTS, LLC. NO PLAN ROOM,
ELECTRONIC PLAN SERVICE (INTERNET PLAN
SERVICE), NOR REPRODUCTION COMPANY SHALL BE
PERMITTED TO POST THESE DOCUMENTS WITHOUT
THE EXPRESSED WRITTEN CONSENT OF THE
ARCHITECT, GRACE HEBERT CURTIS ARCHITECTS,LLC.
SHEET NUMBER
DATE
PHASE
ISSUED FOR
PROJECT NO.
GRACE HEBERT CURTIS ARCHITECTS, LLC
5/
/2
:1 2:
A
M Au to de sk D oc s:
//5
T D
C J
M on tfo rd
U ni t/M on tfo rd
U ni t - A rc h
M od el .rv t
C O
N
VE
R T
TR
U
ST
Y
C A
M P
TO
SH
EL
TE
R
ED
B
ED
S
FA
C
IL
IT
Y
TE
XA
S D
EP
AR
TM
EN
T O
F C
R
IM
IN
AL
J U
ST
IC
E
P
EA
C
H A
VE
N
U E
LU
BB
O C
K, T
X
G003
TYPICAL PARTITION
DETAILS
MWR NO. 09023014
CONSTRUCTION DOCUMENTS
03/21/25
PROPOSAL
1 1/2" = 1'-0"7 ELEC BOX RATED / SMOKE WALLS
1" = 1'-0"8 RECESSED EQUIPMENT, BOXES & DEVICES DETAIL
1 1/2" = 1'-0"3 GYP BD CONTROL JOINT DETAIL
1 1/2" = 1'-0"2 NON-RATED WALL ABUTTING EXTERIOR WALL DTL
1 1/2" = 1'-0"5
PATCH @ PENETRATIONS IN
RATED / SMOKE WALLS
1 1/2" = 1'-0"6 RATED SMOKE WALL PENETRATIONS
1 1/2" = 1'-0"1 RATED AND/OR SMOKE WALL @ EXTERIOR WALL
1 1/2" = 1'-0"4 FLOOR ABUTMENT DETAILS
1 1/2" = 1'-0"9 TYP. STUD WALL ACOUSTICAL PENETRATION
03/21/25
No. Description Date
LIFE SAFETY LEGEND
CPT PATH #
1 HOUR FIRE BARRIER
2 HOUR FIRE BARRIER
SMOKE PARTITION
1 HOUR RATED
FIRE/SMOKE BARRIER
2 HOUR RATED
FIRE/SMOKE BARRIER
COMMON PATH OF TRAVEL (CPT)
GREATEST DIAGONAL DISTANCE (GDD)
MAX TRAVEL DISTANCE (MTD)
EXIT SEPARATION DISTANCE (ESD)
CPT #-# MTD #-#
ESD #GDD #
CPT SEGMENT # MTD PATH # MTD SEGMENT #
GDD PATH # ESD PATH #
EXIT SIGN - SHADED SIDE
DENOTES FACE, ARROW DENOTES
DIRECTION TO EXIT
SQ. FT. OF
SPACE OR
ROOM
EXIT MAX CAPACITY
EXIT WIDTH (INCHES)
EXIT NO.
NUMBER OF OCC EXITING
FIRE HOSE REEL
A-1 9999 SF
Name
OCCUPANCY
CAP
32"
LIFE SAFETY GENERAL NOTES
1.
2.
3.
4.
5.
6.
REFER TO A100 SERIES SHEETS FOR RATED AND NON-RATED PARTITION TYPES.
REFER T0 THE MECHANICAL DRAWINGS FOR FIRE DAMPER AND/OR FIRE/ SMOKE DAMPER LOCATIONS.
REFER TO THE ELECTRICAL DRAWINGS FOR EMERGENCY ILLUMINATION AND ALL FIRE ALARM
DEVICES.
ALL DOOR HARDWARE SHALL MEET OR EXCEED ALL APPLICABLE CODES.
PROVIDE FIRE EXTINGUISHERS AS SHOWN ON PLANS AND/ OR AS DIRECTED BY THE FIRE MARSHAL'S
OFFICE.
REFER TO G003 FOR PARTITION TYPES
LIFE SAFETY SUMMARY #300
AUTHORITY HAVING JURISDICTION
APPLICABLE BUILDING CODES
TDJC, CITY OF LUBBOCK
BUILDING CODE
FIRE / LIFE SAFETY CODE
PLUMBING CODE
MECHANICAL CODE
ELECTRICAL CODE
ENERGY CODE
ACCESSIBILITY CODE
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL FIRE CODE
2021 INTERNATIONAL PLUMBING CODE
2021 INTERNATIONAL MECHANICAL CODE
2020 NATIONAL ELECTRICAL CODE
2021 INTERNATIONAL ENERGY CONSERVATION CODE
2012 TEXAS ACCESSIBILITY STANDARDS / 2010 ADA
FIRE SUPPRESSION (IEBC 403) FIRE HOSE REEL IN CABINET
IIBCONSTRUCTION TYPE
VARIES - RE: PLANOCCUPANCY TYPE
BUILDING CODE SUMMARY
BUILDING AREA (GROSS) 8,825 SF
AREA LIMITATION PER STORY N/A
HEIGHT LIMITATION
BUILDING OCCUPANT COUNT
EGRESS COMPONENTS
EXIT DOORS
EXITING
IBC 1006.3.3 2 REQ'D. 3 PROVIDED.
SPACES REQUIRING 2 EXITS 50+ OCCUPANTS
EXIT ACCESS TRAVEL DISTANCE N/A
COMMON PATH OF EGRESS N/A
ARRANGEMENT OF EXITS IBC 1007.1.1: 1/2 OF MAXIMUM OVERALL DIAGONAL
FIRE RESISTANCE REQUIREMENT
FIRE RATING REQUIREMENTS TABLE 601
PRIMARY STRUCTURAL FRAME: 0 HR
BEARING WALLS (EXT & INT): 0 HR
NON BEARING INTERIOR WALLS: 0 HR
FLOOR & SECONDARY MEMBERS: 0 HR
ROOF & SECONDARY MEMBERS: 0 HR
EXTERIOR FIRE SEPARATION
CONSTRUCTION TYPE: IIB
TABLE 705.5
X < 5 = 1 HR
5' < X < 10' = 1 HR
10' < X < 30' = 0 HR
X > 30' = 0 HR
CORRIDORS
OTHER PERMANENT PARTITIONS
N/A
IBC 602 & 603
IBC 1011.2
EXISTING BUILDING 2021 INTERNATIONAL EXISTING BUILDING CODE
CONSTRUCTION TYPE: IIB
32" MIN CLEAR. 48 MAX LEAF
N/A
PLUMBING FIXTURE CALCULATION
BASED ON 2021 IBC, CHAPTER 29 TABLE 2902.1
NO. OF OCCUPANTS: 56 GROUP: I-3 INSTITUTIONAL
WATER CLOSETS
PROVIDED
1:15
4 4 1
1:100 1
1 15
1:15
4 9
REQUIRED
LAVATORIES
PROVIDEDREQUIRED
DRINKING FOUNTAINS
PROVIDEDREQUIRED
SERVICE SINKS
PROVIDEDREQUIRED
1404 SFA3
DINING
798 SF-
TOILETS / SHOWERS
48 SF-
MECH / ELEC
6090 SFI-3
DORMITORY
34 SF-
JAN
181'-0" = GREATEST DIAGONAL
181'-0" / 2 = 90'-6" MIN EXIT SEPARATION
93'-4" EXIT SEPARATION
40 SF
MECH / ELEC
SEAL:
© THIS SET OF DOCUMENTS INCLUSIVE OF
DRAWINGS, SPECIFICATIONS, AND ADDENDUMS MAY
NOT BE COPIED, SCANNED, NOR ELECTRONICALLY
DISTRIBUTED OR USED FOR CONSTRUCTION WITHOUT
THE EXPRESSED WRITTEN CONSENT OF GRACE
HEBERT CURTIS ARCHITECTS, LLC. NO PLAN ROOM,
ELECTRONIC PLAN SERVICE (INTERNET PLAN
SERVICE), NOR REPRODUCTION COMPANY SHALL BE
PERMITTED TO POST THESE DOCUMENTS WITHOUT
THE EXPRESSED WRITTEN CONSENT OF THE
ARCHITECT, GRACE HEBERT CURTIS ARCHITECTS,LLC.
SHEET NUMBER
DATE
PHASE
ISSUED FOR
PROJECT NO.
GRACE HEBERT CURTIS ARCHITECTS, LLC
5/
/2
:1 2:
A
M Au to de sk D oc s:
//5
T D
C J
M on tfo rd
U ni t/M on tfo rd
U ni t - A rc h
M od el .rv t
C O
N
VE
R T
TR
U
ST
Y
C A
M P
TO
SH
EL
TE
R
ED
B
ED
S
FA
C
IL
IT
Y
TE
XA
S D
EP
AR
TM
EN
T O
F C
R
IM
IN
AL
J U
ST
IC
E
P
EA
C
H A
VE
N
U E
LU
BB
O C
K, T
X
LS.3
LIFE SAFETY PLAN -
BUILDING #300
MWR NO. 09023014
CONSTRUCTION DOCUMENTS
03/21/25
PROPOSAL
PLAN
NORTH
1/8" = 1'-0"1 LIFE SAFETY PLAN - BUILDING #300
03/21/25
No. Description Date
798 SF
TOILETS / SHOWERS
1404 SF
DINING
6090 SFI-3
DORMITORY
48 SF
MECH / ELEC
40 SF
MECH / ELEC
34 SF
JAN
181'-0" = GREATEST DIAGONAL
181'-0" / 2 = 90'-6" MIN EXIT SEPARATION
93'-4" EXIT SEPARATION
LIFE SAFETY LEGEND
CPT PATH #
1 HOUR FIRE BARRIER
2 HOUR FIRE BARRIER
SMOKE PARTITION
1 HOUR RATED
FIRE/SMOKE BARRIER
2 HOUR RATED
FIRE/SMOKE BARRIER
COMMON PATH OF TRAVEL (CPT)
GREATEST DIAGONAL DISTANCE (GDD)
MAX TRAVEL DISTANCE (MTD)
EXIT SEPARATION DISTANCE (ESD)
CPT #-# MTD #-#
ESD #GDD #
CPT SEGMENT # MTD PATH # MTD SEGMENT #
GDD PATH # ESD PATH #
EXIT SIGN - SHADED SIDE
DENOTES FACE, ARROW DENOTES
DIRECTION TO EXIT
SQ. FT. OF
SPACE OR
ROOM
EXIT MAX CAPACITY
EXIT WIDTH (INCHES)
EXIT NO.
NUMBER OF OCC EXITING
FIRE HOSE REEL
A-1 9999 SF
Name
OCCUPANCY
CAP
32"
LIFE SAFETY GENERAL NOTES
1.
2.
3.
4.
5.
6.
REFER TO A100 SERIES SHEETS FOR RATED AND NON-RATED PARTITION TYPES.
REFER T0 THE MECHANICAL DRAWINGS FOR FIRE DAMPER AND/OR FIRE/ SMOKE DAMPER LOCATIONS.
REFER TO THE ELECTRICAL DRAWINGS FOR EMERGENCY ILLUMINATION AND ALL FIRE ALARM
DEVICES.
ALL DOOR HARDWARE SHALL MEET OR EXCEED ALL APPLICABLE CODES.
PROVIDE FIRE EXTINGUISHERS AS SHOWN ON PLANS AND/ OR AS DIRECTED BY THE FIRE MARSHAL'S
OFFICE.
REFER TO G003 FOR PARTITION TYPES
PLUMBING FIXTURE CALCULATION
BASED ON 2021 IBC, CHAPTER 29 TABLE 2902.1
NO. OF OCCUPANTS: 56 GROUP: I-3 INSTITUTIONAL
WATER CLOSETS
PROVIDED
1:15
4 4 1
1:100 1
1 15
1:15
4 9
REQUIRED
LAVATORIES
PROVIDEDREQUIRED
DRINKING FOUNTAINS
PROVIDEDREQUIRED
SERVICE SINKS
PROVIDEDREQUIRED
LIFE SAFETY SUMMARY #700
AUTHORITY HAVING JURISDICTION
APPLICABLE BUILDING CODES
TDJC, CITY OF LUBBOCK
BUILDING CODE
FIRE / LIFE SAFETY CODE
PLUMBING CODE
MECHANICAL CODE
ELECTRICAL CODE
ENERGY CODE
ACCESSIBILITY CODE
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL FIRE CODE
2021 INTERNATIONAL PLUMBING CODE
2021 INTERNATIONAL MECHANICAL CODE
2020 NATIONAL ELECTRICAL CODE
2021 INTERNATIONAL ENERGY CONSERVATION CODE
2012 TEXAS ACCESSIBILITY STANDARDS / 2010 ADA
FIRE SUPPRESSION (IEBC 403) FIRE HOSE REEL IN CABINET
IIBCONSTRUCTION TYPE
VARIES - RE: PLANOCCUPANCY TYPE
BUILDING CODE SUMMARY
BUILDING AREA (GROSS) 8,825 SF
AREA LIMITATION PER STORY N/A
HEIGHT LIMITATION
BUILDING OCCUPANT COUNT
EGRESS COMPONENTS
EXIT DOORS
EXITING
IBC 1006.3.3 2 REQ'D. 3 PROVIDED.
SPACES REQUIRING 2 EXITS 50+ OCCUPANTS
EXIT ACCESS TRAVEL DISTANCE N/A
COMMON PATH OF EGRESS N/A
ARRANGEMENT OF EXITS IBC 1007.1.1: 1/2 OF MAXIMUM OVERALL DIAGONAL
FIRE RESISTANCE REQUIREMENT
FIRE RATING REQUIREMENTS TABLE 601
PRIMARY STRUCTURAL FRAME: 0 HR
BEARING WALLS (EXT & INT): 0 HR
NON BEARING INTERIOR WALLS: 0 HR
FLOOR & SECONDARY MEMBERS: 0 HR
ROOF & SECONDARY MEMBERS: 0 HR
EXTERIOR FIRE SEPARATION
CONSTRUCTION TYPE: IIB
TABLE 705.5
X < 5 = 1 HR
5' < X < 10' = 1 HR
10' < X < 30' = 0 HR
X > 30' = 0 HR
CORRIDORS
OTHER PERMANENT PARTITIONS
N/A
IBC 602 & 603
IBC 1011.2
EXISTING BUILDING 2021 INTERNATIONAL EXISTING BUILDING CODE
CONSTRUCTION TYPE: IIB
32" MIN CLEAR. 48 MAX LEAF
N/A
SEAL:
© THIS SET OF DOCUMENTS INCLUSIVE OF
DRAWINGS, SPECIFICATIONS, AND ADDENDUMS MAY
NOT BE COPIED, SCANNED, NOR ELECTRONICALLY
DISTRIBUTED OR USED FOR CONSTRUCTION WITHOUT
THE EXPRESSED WRITTEN CONSENT OF GRACE
HEBERT CURTIS ARCHITECTS, LLC. NO PLAN ROOM,
ELECTRONIC PLAN SERVICE (INTERNET PLAN
SERVICE), NOR REPRODUCTION COMPANY SHALL BE
PERMITTED TO POST THESE DOCUMENTS WITHOUT
THE EXPRESSED WRITTEN CONSENT OF THE
ARCHITECT, GRACE HEBERT CURTIS ARCHITECTS,LLC.
SHEET NUMBER
DATE
PHASE
ISSUED FOR
PROJECT NO.
GRACE HEBERT CURTIS ARCHITECTS, LLC
5/
/2
:1 2:
A
M Au to de sk D oc s:
//5
T D
C J
M on tfo rd
U ni t/M on tfo rd
U ni t - A rc h
M od el .rv t
C O
N
VE
R T
TR
U
ST
Y
C A
M P
TO
SH
EL
TE
R
ED
B
ED
S
FA
C
IL
IT
Y
TE
XA
S D
EP
AR
TM
EN
T O
F C
R
IM
IN
AL
J U
ST
IC
E
P
EA
C
H A
VE
N
U E
LU
BB
O C
K, T
X
LS.7
LIFE SAFETY PLAN -
BUILDING #700
MWR NO. 09023014
CONSTRUCTION DOCUMENTS
03/21/25
PROPOSAL
PLAN
NORTH
1/8" = 1'-0"1 LIFE SAFETY PLAN - BUILDING #700
03/21/25
No. Description Date
6498 SFI-3
Area
608 SFI-3
INMATE HOLDING
161'-0" = GREATEST DIAGONAL
161'-0" / 2 = 80'-6" MIN EXIT SEPARATION
82'-6" EXIT SEPARATION
1011 SF
STORAGE
276 SF
JAN
361 SF
STORAGE
127 SF
TOILETS / SHOWERS
136 SF
TOILETS / SHOWERS
LIFE SAFETY LEGEND
CPT PATH #
1 HOUR FIRE BARRIER
2 HOUR FIRE BARRIER
SMOKE PARTITION
1 HOUR RATED
FIRE/SMOKE BARRIER
2 HOUR RATED
FIRE/SMOKE BARRIER
COMMON PATH OF TRAVEL (CPT)
GREATEST DIAGONAL DISTANCE (GDD)
MAX TRAVEL DISTANCE (MTD)
EXIT SEPARATION DISTANCE (ESD)
CPT #-# MTD #-#
ESD #GDD #
CPT SEGMENT # MTD PATH # MTD SEGMENT #
GDD PATH # ESD PATH #
EXIT SIGN - SHADED SIDE
DENOTES FACE, ARROW DENOTES
DIRECTION TO EXIT
SQ. FT. OF
SPACE OR
ROOM
EXIT MAX CAPACITY
EXIT WIDTH (INCHES)
EXIT NO.
NUMBER OF OCC EXITING
FIRE HOSE REEL
A-1 9999 SF
Name
OCCUPANCY
CAP
32"
LIFE SAFETY GENERAL NOTES
1.
2.
3.
4.
5.
6.
REFER TO A100 SERIES SHEETS FOR RATED AND NON-RATED PARTITION TYPES.
REFER T0 THE MECHANICAL DRAWINGS FOR FIRE DAMPER AND/OR FIRE/ SMOKE DAMPER LOCATIONS.
REFER TO THE ELECTRICAL DRAWINGS FOR EMERGENCY ILLUMINATION AND ALL FIRE ALARM
DEVICES.
ALL DOOR HARDWARE SHALL MEET OR EXCEED ALL APPLICABLE CODES.
PROVIDE FIRE EXTINGUISHERS AS SHOWN ON PLANS AND/ OR AS DIRECTED BY THE FIRE MARSHAL'S
OFFICE.
REFER TO G003 FOR PARTITION TYPES
PLUMBING FIXTURE CALCULATION
BASED ON 2021 IBC, CHAPTER 29 TABLE 2902.1
NO. OF OCCUPANTS: 56 GROUP: I-3 INSTITUTIONAL
WATER CLOSETS
PROVIDED
1:15
4 4 1
1:100 1
1 15
1:15
4 9
REQUIRED
LAVATORIES
PROVIDEDREQUIRED
DRINKING FOUNTAINS
PROVIDEDREQUIRED
SERVICE SINKS
PROVIDEDREQUIRED
LIFE SAFETY SUMMARY #700
AUTHORITY HAVING JURISDICTION
APPLICABLE BUILDING CODES
TDJC, CITY OF LUBBOCK
BUILDING CODE
FIRE / LIFE SAFETY CODE
PLUMBING CODE
MECHANICAL CODE
ELECTRICAL CODE
ENERGY CODE
ACCESSIBILITY CODE
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL FIRE CODE
2021 INTERNATIONAL PLUMBING CODE
2021 INTERNATIONAL MECHANICAL CODE
2020 NATIONAL ELECTRICAL CODE
2021 INTERNATIONAL ENERGY CONSERVATION CODE
2012 TEXAS ACCESSIBILITY STANDARDS / 2010 ADA
FIRE SUPPRESSION (IEBC 403) FIRE HOSE REEL IN CABINET
IIBCONSTRUCTION TYPE
VARIES - RE: PLANOCCUPANCY TYPE
BUILDING CODE SUMMARY
BUILDING AREA (GROSS) 8,825 SF
AREA LIMITATION PER STORY N/A
HEIGHT LIMITATION
BUILDING OCCUPANT COUNT
EGRESS COMPONENTS
EXIT DOORS
EXITING
IBC 1006.3.3 2 REQ'D. 6 PROVIDED.
SPACES REQUIRING 2 EXITS 50+ OCCUPANTS
EXIT ACCESS TRAVEL DISTANCE N/A
COMMON PATH OF EGRESS N/A
ARRANGEMENT OF EXITS IBC 1007.1.1: 1/2 OF MAXIMUM OVERALL DIAGONAL
FIRE RESISTANCE REQUIREMENT
FIRE RATING REQUIREMENTS TABLE 601
PRIMARY STRUCTURAL FRAME: 0 HR
BEARING WALLS (EXT & INT): 0 HR
NON BEARING INTERIOR WALLS: 0 HR
FLOOR & SECONDARY MEMBERS: 0 HR
ROOF & SECONDARY MEMBERS: 0 HR
EXTERIOR FIRE SEPARATION
CONSTRUCTION TYPE: IIB
TABLE 705.5
X < 5 = 1 HR
5' < X < 10' = 1 HR
10' < X < 30' = 0 HR
X > 30' = 0 HR
CORRIDORS
OTHER PERMANENT PARTITIONS
N/A
IBC 602 & 603
IBC 1011.2
EXISTING BUILDING 2021 INTERNATIONAL EXISTING BUILDING CODE
CONSTRUCTION TYPE: IIB
32" MIN CLEAR. 48 MAX LEAF
N/A
SEAL:
© THIS SET OF DOCUMENTS INCLUSIVE OF
DRAWINGS, SPECIFICATIONS, AND ADDENDUMS MAY
NOT BE COPIED, SCANNED, NOR ELECTRONICALLY
DISTRIBUTED OR USED FOR CONSTRUCTION WITHOUT
THE EXPRESSED WRITTEN CONSENT OF GRACE
HEBERT CURTIS ARCHITECTS, LLC. NO PLAN ROOM,
ELECTRONIC PLAN SERVICE (INTERNET PLAN
SERVICE), NOR REPRODUCTION COMPANY SHALL BE
PERMITTED TO POST THESE DOCUMENTS WITHOUT
THE EXPRESSED WRITTEN CONSENT OF THE
ARCHITECT, GRACE HEBERT CURTIS ARCHITECTS,LLC.
SHEET NUMBER
DATE
PHASE
ISSUED FOR
PROJECT NO.
GRACE HEBERT CURTIS ARCHITECTS, LLC
5/
/2
:1 2:
A
M Au to de sk D oc s:
//5
T D
C J
M on tfo rd
U ni t/M on tfo rd
U ni t - A rc h
M od el .rv t
C O
N
VE
R T
TR
U
ST
Y
C A
M P
TO
SH
EL
TE
R
ED
B
ED
S
FA
C
IL
IT
Y
TE
XA
S D
EP
AR
TM
EN
T O
F C
R
IM
IN
AL
J U
ST
IC
E
P
EA
C
H A
VE
N
U E
LU
BB
O C
K, T
X
LS.9
LIFE SAFETY PLAN -
BUILDING #900
MWR NO. 09023014
CONSTRUCTION DOCUMENTS
03/21/25
PROPOSAL
PLAN
NORTH
1/8" = 1'-0"1 LIFE SAFETY PLAN - BUILDING #900
03/21/25
No. Description Date
Site Plan General Notes:Site Demolition Plan Notes:
Paving Plan Notes:
Dimension Control Notes:
Grading Plan Notes:
Erosion Control Plan Notes:
Striping and Accessible Notes:
SEAL:
© THIS SET OF DOCUMENTS INCLUSIVE OF
DRAWINGS, SPECIFICATIONS, AND ADDENDUMS MAY
NOT BE COPIED, SCANNED, NOR ELECTRONICALLY
DISTRIBUTED OR USED FOR CONSTRUCTION WITHOUT
THE EXPRESSED WRITTEN CONSENT OF GRACE
HEBERT CURTIS ARCHITECTS, LLC. NO PLAN ROOM,
ELECTRONIC PLAN SERVICE (INTERNET PLAN
SERVICE), NOR REPRODUCTION COMPANY SHALL BE
PERMITTED TO POST THESE DOCUMENTS WITHOUT
THE EXPRESSED WRITTEN CONSENT OF THE
ARCHITECT, GRACE HEBERT CURTIS ARCHITECTS,LLC.
SHEET NUMBER
DATE
PHASE
ISSUED FOR
PROJECT NO.
GRACE HEBERT CURTIS ARCHITECTS, LLC
M O
N
TF
O R
D : T
R U
ST
Y
C A
M P
R
EN
O
VA
TI
O
N
TE
XA
S
D
EP
AR
TM
EN
T
O F
C R
IM
IN
AL
J
U
ST
IC
E
P
EA
C H
A
VE
N U
E
LU
BB
O
C K, T X
MWR NO. 09023014
CONSTRUCTION DOCUMENTS
03/21/2025
PROPOSAL
No. Description Date
PROJECT NO:
JQ INFRASTRUCTURE, LLC
100 GLASS STREET, SUITE 201
972.392.7340
DALLAS, TEXAS 75207
TBPE FIRM 7986
shaping the built environment
Infrastructure
4240051
OVIDIU M. SIPOS
STA T E OF T EXAS
PROF ES S I ONA L E NG I NEER
L I C E NS ED
111707
03/21/2025
C0.01
GENERAL NOTES
Exhibit J.6
696-FD-26-P027
AutoCAD SHX Text
1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CITY CONSTRUCTION STANDARDS AND SPECIFICATIONS. FOR ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CITY CONSTRUCTION STANDARDS AND SPECIFICATIONS. FOR ANY WORK NOT GOVERNED BY CITY DETAILS. THE LATEST EDITION OF THE STANDARDS AND SPECIFICATIONS, NORTH CENTRAL TEXAS COUNCIL OF GOVERNMENTS (NCTCOG) STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION SHALL APPLY. 2. THE CONTRACTOR MUST BE FAMILIAR WITH OWNER & CITY CONSTRUCTION STANDARDS AND OTHER PROCEDURES PRIOR THE CONTRACTOR MUST BE FAMILIAR WITH OWNER & CITY CONSTRUCTION STANDARDS AND OTHER PROCEDURES PRIOR TO BIDDING AND CONSTRUCTION. IGNORANCE OF CONSTRUCTION SPECIFICATIONS SHALL NOT BE A BASIS FOR CHANGE ORDERS, WORK DELAYS, OR ADDITIONAL COMPENSATION. 3. ALL MATERIAL REQUIRED TO COMPLETE THE WORK AS SHOWN OR IMPLIED IN THE CONSTRUCTION PLANS AND AS ALL MATERIAL REQUIRED TO COMPLETE THE WORK AS SHOWN OR IMPLIED IN THE CONSTRUCTION PLANS AND AS SPECIFIED IN THE CONTRACT DOCUMENTS THAT ARE NOT LISTED AS A PAY ITEM IN THE PROPOSAL SHALL BE CONSIDERED SUBSIDIARY. 4. THE LOCATION, ELEVATIONS AND DIMENSIONS OF EXISTING UTILITIES SHOWN ON THE PLANS HAVE BEEN OBTAINED THE LOCATION, ELEVATIONS AND DIMENSIONS OF EXISTING UTILITIES SHOWN ON THE PLANS HAVE BEEN OBTAINED FROM FIELD MARKINGS, PHYSICAL APPURTENANCES AND UTILITY COMPANY RECORDS AND ARE CONSIDERED APPROXIMATE. THE ENGINEER DOES NOT CERTIFY THAT ALL UTILITIES ARE SHOWN. THE CONTRACTOR SHALL VERIFY EXACT LOCATIONS, SIZES AND DEPTHS OF EXISTING UTILITIES PRIOR TO CONSTRUCTION BY CONTACTING TEXAS811 AND RELEVANT UTILITY COMPANIES 48 HOURS PRIOR TO LOCATING EXISTING UTILITIES OR CONSTRUCTION ACTIVITIES. 5.