6OH0315 Exhibit B - Wall Types.pdf

PDF 1 MB Posted

Attached to
US Government seeks to Lease Office Space in Cleveland, Ohio
Solicitation number
6OH0315
Issued by

About this file

This is a Design Guide for Wall Types that serves as Exhibit B Agency Requirements for RLP No. 6OH0315, a federal lease solicitation issued by U.S. Citizenship and Immigration Services (USCIS) Facilities Management Division. The document provides technical specifications and architectural drawings for eight partition wall types required for District and Field Office construction and renovation projects.

The guide details specific wall construction requirements for different applications: Partition Type 1 (W-1) specifies a standard demising wall with 5/8" Type X gypsum wallboard, 3 5/8" metal studs at 24" on-center, and 3 1/2" sound batt insulation, achieving a minimum Noise Isolation Class (NIC) of 40 minimum; Partition Type 2 (W-2) is a similar construction without insulation and does not require NIC rating; Partition Type 3 (W-3) uses top track connection to the deck with no NIC requirement; Partition Type 4 (W-4) is an enhanced acoustic wall with QuietRock ES gypsum board inner layer, 20-gauge metal studs, acoustic sealant on top and bottom tracks, minimized penetrations, and acoustic liners on ducts, achieving NIC 45 minimum; Partition Type 5 (W-5) includes fire-rated plywood attached to back and side walls with intumescent paint for LAN room applications, achieving NIC 40 minimum; Partition Type 6 (W-6) utilizes moisture-resistant gypsum board for wet wall sides in restrooms with ceramic tile cove base and wainscot ceramic tile to 5'-0", achieving NIC 40 minimum; Partition Type 7 (W-7) incorporates stainless steel or high-impact vinyl wall protection to 48" above finished floor for mailroom applications with no NIC requirement; and Partition Type 8 (W-8) is a secure demising wall with 1/2" Level 3 ballistic sheathing, 9-11 security carbon steel mesh, 3/4" plywood sheathing, 20-gauge 3 5/8" metal studs at 16" on-center, achieving NIC 50 minimum. All partition types reference scheduled flooring, finished slab conditions, and 2x2 acoustical ceiling tile at 9'-0" minimum height. The guide was updated to Version 1.7 in July 2026.

View the file

Other files

Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Design Guide - Wall Types

RLP No. 6OH0315 - Exhibit B Agency Requirements

LESSOR: ______ GOVERNMENT: ______

PARTITION TYPE 1W1 SCALE : N.T.S.

8" TYPE "X" GWB

EITHER SIDE

3 58" METAL STUD

@ 24" O.C.

3 12" SOUND BATT

INSULATION

BOTTOM

TRACK

PER SCHEDULE

2x2 ACT CEILING

@ 9'-0" HT. MIN.

DECK

FLOORING

PER SCHEDULE

NIC 40 min.

FINISHED

SLAB

BRACING PER MTL.

STUD MANUFACTURER

RECOMMENDATIONS6"

U.S. Citizenship and Immigration Services PARTITION TYPE 1

Drawing Name: Sheet #:

W-1 District and Field Office

Design Guide USCIS Facilities Management Division

Version 1.7 - July 2026

NOTE:

ACOUSTIC CONSULTANT

SHALL REVIEW OVERALL ROOM

DESIGN TO ENSURE NIC 40

PARTITION TYPE 2W2

8" TYPE "X" GWB

EITHER SIDE

3 58" METAL STUD

@ 24" O.C.

2x2 ACT CEILING

@ 9'-0" HT. MIN.

BRACING PER MTL.

STUD MANUFACTURER

RECOMMENDATIONS

N/A NIC

6"

SCALE : N.T.S.

BOTTOM

TRACK

PER SCHEDULE

FLOORING

PER SCHEDULE

FINISHED

SLAB

DECK

U.S. Citizenship and Immigration Services PARTITION TYPE 2

Drawing Name: Sheet #:

W-2 District and Field Office

Design Guide USCIS Facilities Management Division

Version 1.7 - July 2026

PARTITION TYPE 1W3 N/A NIC

8" TYPE "X" GWB

EITHER SIDE

3 58" METAL STUD

@ 24" O.C.

2x2 ACT CEILING

@ 9'-0" HT. MIN.

TOP TRACK

SCALE : N.T.S.

BOTTOM

TRACK

PER SCHEDULE

FLOORING

PER SCHEDULE

FINISHED

SLAB

DECK

U.S. Citizenship and Immigration Services PARTITION TYPE 3

Drawing Name: Sheet #:

W-3 District and Field Office

Design Guide USCIS Facilities Management Division

PARTITION TYPE 4W4

8" TYPE "X" GWB

OUTER LAYER

8" QUIETROCK ES GWB

INNER LAYER (OR EQ.)

20ga. 3 58" METAL STUD @ 24" O.C.

3 12" SOUND BATT

INSULATION

20ga. BOTTOM TRACK w/ ACOUSTIC SEALANT

BETWEEN TRACK & FLOOR

2x2 ACT CEILING

@ 9'-0" HT. MIN.

20ga.TOP TRACK w/ ACOUSTIC SEALANT

BETWEEN TRACK & DECK

MINIMIZE HORIZONTAL

PENETRATIONS

ACOUSTIC CAULK ANY

PENETRATIONS

PROVIDE ACOUSTIC

LINERS TO ALL DUCTS

PAINT VERTICAL

GWB ABOVE

ACT BLACK

NIC 45 min.

SCALE : N.T.S.

FLOORING

PER SCHEDULE

FINISHED

SLAB PER SCHEDULE

DECK

U.S. Citizenship and Immigration Services PARTITION TYPE 4

Drawing Name: Sheet #:

W-4 District and Field Office

Design Guide USCIS Facilities Management Division

PARTITION TYPE 5W5

8" TYPE "X" GWB

EITHER SIDE

3 58" METAL STUD

@ 24" O.C.

3 12" BATT

INSULATION

2x2 ACT CEILING

@ 9'-0" HT. MIN.

TOP TRACK

NIC 40 min.

4" FIRE RATED (F.R.)

PLY. ATTACHED TO

BACK & SIDE WALLS.

PNT'D WITH

INTUMESCENT

PAINT. LEAVE F.R.

LABELS UNPAINTED

LAN ROOM

6 MIL. VAPOR

BARRIER

CORRIDOR

SCALE : N.T.S.

BOTTOM

TRACK

PER SCHEDULE

FLOORING

PER SCHEDULE

FINISHED

SLAB

DECK

U.S. Citizenship and Immigration Services PARTITION TYPE 5

Drawing Name: Sheet #:

W-5 District and Field Office

Design Guide USCIS Facilities Management Division

Version 1.7 - July 2026

PARTITION TYPE 6W6

8" MOISTURE RESISTANT

GWB WET WALL SIDE.

3 58" METAL STUD

@ 24" O.C.

3 12" SOUND BATT

INSULATION

2x2 ACT CEILING

@ 9'-0" HT. MIN.

TOP TRACK

CERAMIC

TILE FLOOR

NIC 40 min.

RESTROOM CORRIDOR

8" TYPE "X" GWB

C.T. WAINSCOT

WET WALLS

5' -0

W

ET

W

AL

LS

C.T. COVE BASE

ENTIRE ROOM

SCALE : N.T.S.

BOTTOM

TRACK

PER SCHEDULE

DECK

U.S. Citizenship and Immigration Services PARTITION TYPE 6

Drawing Name: Sheet #:

W-6 District and Field Office

Design Guide USCIS Facilities Management Division

Version 1.7 - July 2026

PARTITION TYPE 7W7 N/A NIC

8" TYPE "X" GWB

EITHER SIDE

3 58" METAL STUD

@ 24" O.C.

2x2 ACT CEILING

@ 9'-0" HT. MIN.

STAINLESS OR

HIGH IMPACT

VINYL WALL

PROTECTION TO

48" AFF

SCALE : N.T.S.

BOTTOM

TRACK

PER SCHEDULE

FLOORING

PER SCHEDULE

FINISHED

SLAB

MAILROOM CORRIDOR

DECK

U.S. Citizenship and Immigration Services PARTITION TYPE 7

Drawing Name: Sheet #:

W-7 District and Field Office

Design Guide USCIS Facilities Management Division

PARTITION TYPE 8W8

8" TYPE "X" GWB

OUTER LAYER

20ga. 3 58" METAL STUD @ 16" O.C.

3 12" SOUND BATT

INSULATION

20ga. BOTTOM TRACK w/ ACOUSTIC SEALANT

BETWEEN TRACK & FLOOR

2x2 ACT CEILING

@ 9'-0" HT. MIN.

20ga.TOP TRACK w/ ACOUSTIC SEALANT

BETWEEN TRACK & DECK

MINIMIZE HORIZONTAL

PENETRATIONS

ACOUSTIC CAULK ANY

PENETRATIONS

PROVIDE ACOUSTIC

LINERS TO ALL DUCTS,

SECURE ANY OPENINGS >96 s.i.

PAINT VERTICAL

GWB ABOVE

ACT BLACK

NIC 50 min.

SCALE : N.T.S.

FLOORING

PER SCHEDULE

FINISHED

SLAB PER SCHEDULE

4" PLYWOOD

SHEATHING

9-11 SECURITY

CARBON STEEL

MESH, FASTEN 6"

HORIZONTAL &

VERTICAL INTO

PLYWOOD

OUTSIDE OF

SUITE

SECURE SUITE

SIDE

DECK

2" LEVEL 3

BALLISTIC

SHEATHING

U.S. Citizenship and Immigration Services

PARTITION TYPE 8

-SECURE DEMISING WALL-

Drawing Name: Sheet #:

W-8 District and Field Office

Design Guide USCIS Facilities Management Division

File details come from the government source that posted it. Updated .