This is a Design Guide for Wall Types that serves as Exhibit B Agency Requirements for RLP No. 6OH0315, a federal lease solicitation issued by U.S. Citizenship and Immigration Services (USCIS) Facilities Management Division. The document provides technical specifications and architectural drawings for eight partition wall types required for District and Field Office construction and renovation projects.
The guide details specific wall construction requirements for different applications: Partition Type 1 (W-1) specifies a standard demising wall with 5/8" Type X gypsum wallboard, 3 5/8" metal studs at 24" on-center, and 3 1/2" sound batt insulation, achieving a minimum Noise Isolation Class (NIC) of 40 minimum; Partition Type 2 (W-2) is a similar construction without insulation and does not require NIC rating; Partition Type 3 (W-3) uses top track connection to the deck with no NIC requirement; Partition Type 4 (W-4) is an enhanced acoustic wall with QuietRock ES gypsum board inner layer, 20-gauge metal studs, acoustic sealant on top and bottom tracks, minimized penetrations, and acoustic liners on ducts, achieving NIC 45 minimum; Partition Type 5 (W-5) includes fire-rated plywood attached to back and side walls with intumescent paint for LAN room applications, achieving NIC 40 minimum; Partition Type 6 (W-6) utilizes moisture-resistant gypsum board for wet wall sides in restrooms with ceramic tile cove base and wainscot ceramic tile to 5'-0", achieving NIC 40 minimum; Partition Type 7 (W-7) incorporates stainless steel or high-impact vinyl wall protection to 48" above finished floor for mailroom applications with no NIC requirement; and Partition Type 8 (W-8) is a secure demising wall with 1/2" Level 3 ballistic sheathing, 9-11 security carbon steel mesh, 3/4" plywood sheathing, 20-gauge 3 5/8" metal studs at 16" on-center, achieving NIC 50 minimum. All partition types reference scheduled flooring, finished slab conditions, and 2x2 acoustical ceiling tile at 9'-0" minimum height. The guide was updated to Version 1.7 in July 2026.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Design Guide - Wall Types
RLP No. 6OH0315 - Exhibit B Agency Requirements
LESSOR: ______ GOVERNMENT: ______
PARTITION TYPE 1W1 SCALE : N.T.S.
8" TYPE "X" GWB
EITHER SIDE
3 58" METAL STUD
@ 24" O.C.
3 12" SOUND BATT
INSULATION
BOTTOM
TRACK
PER SCHEDULE
2x2 ACT CEILING
@ 9'-0" HT. MIN.
DECK
FLOORING
PER SCHEDULE
NIC 40 min.
FINISHED
SLAB
BRACING PER MTL.
STUD MANUFACTURER
RECOMMENDATIONS6"
U.S. Citizenship and Immigration Services PARTITION TYPE 1
Drawing Name: Sheet #:
W-1 District and Field Office
Design Guide USCIS Facilities Management Division
Version 1.7 - July 2026
NOTE:
ACOUSTIC CONSULTANT
SHALL REVIEW OVERALL ROOM
DESIGN TO ENSURE NIC 40
PARTITION TYPE 2W2
8" TYPE "X" GWB
EITHER SIDE
3 58" METAL STUD
@ 24" O.C.
2x2 ACT CEILING
@ 9'-0" HT. MIN.
BRACING PER MTL.
STUD MANUFACTURER
RECOMMENDATIONS
N/A NIC
6"
SCALE : N.T.S.
BOTTOM
TRACK
PER SCHEDULE
FLOORING
PER SCHEDULE
FINISHED
SLAB
DECK
U.S. Citizenship and Immigration Services PARTITION TYPE 2
Drawing Name: Sheet #:
W-2 District and Field Office
Design Guide USCIS Facilities Management Division
Version 1.7 - July 2026
PARTITION TYPE 1W3 N/A NIC
8" TYPE "X" GWB
EITHER SIDE
3 58" METAL STUD
@ 24" O.C.
2x2 ACT CEILING
@ 9'-0" HT. MIN.
TOP TRACK
SCALE : N.T.S.
BOTTOM
TRACK
PER SCHEDULE
FLOORING
PER SCHEDULE
FINISHED
SLAB
DECK
U.S. Citizenship and Immigration Services PARTITION TYPE 3
Drawing Name: Sheet #:
W-3 District and Field Office
Design Guide USCIS Facilities Management Division
PARTITION TYPE 4W4
8" TYPE "X" GWB
OUTER LAYER
8" QUIETROCK ES GWB
INNER LAYER (OR EQ.)
20ga. 3 58" METAL STUD @ 24" O.C.
3 12" SOUND BATT
INSULATION
20ga. BOTTOM TRACK w/ ACOUSTIC SEALANT
BETWEEN TRACK & FLOOR
2x2 ACT CEILING
@ 9'-0" HT. MIN.
20ga.TOP TRACK w/ ACOUSTIC SEALANT
BETWEEN TRACK & DECK
MINIMIZE HORIZONTAL
PENETRATIONS
ACOUSTIC CAULK ANY
PENETRATIONS
PROVIDE ACOUSTIC
LINERS TO ALL DUCTS
PAINT VERTICAL
GWB ABOVE
ACT BLACK
NIC 45 min.
SCALE : N.T.S.
FLOORING
PER SCHEDULE
FINISHED
SLAB PER SCHEDULE
DECK
U.S. Citizenship and Immigration Services PARTITION TYPE 4
Drawing Name: Sheet #:
W-4 District and Field Office
Design Guide USCIS Facilities Management Division
PARTITION TYPE 5W5
8" TYPE "X" GWB
EITHER SIDE
3 58" METAL STUD
@ 24" O.C.
3 12" BATT
INSULATION
2x2 ACT CEILING
@ 9'-0" HT. MIN.
TOP TRACK
NIC 40 min.
4" FIRE RATED (F.R.)
PLY. ATTACHED TO
BACK & SIDE WALLS.
PNT'D WITH
INTUMESCENT
PAINT. LEAVE F.R.
LABELS UNPAINTED
LAN ROOM
6 MIL. VAPOR
BARRIER
CORRIDOR
SCALE : N.T.S.
BOTTOM
TRACK
PER SCHEDULE
FLOORING
PER SCHEDULE
FINISHED
SLAB
DECK
U.S. Citizenship and Immigration Services PARTITION TYPE 5
Drawing Name: Sheet #:
W-5 District and Field Office
Design Guide USCIS Facilities Management Division
Version 1.7 - July 2026
PARTITION TYPE 6W6
8" MOISTURE RESISTANT
GWB WET WALL SIDE.
3 58" METAL STUD
@ 24" O.C.
3 12" SOUND BATT
INSULATION
2x2 ACT CEILING
@ 9'-0" HT. MIN.
TOP TRACK
CERAMIC
TILE FLOOR
NIC 40 min.
RESTROOM CORRIDOR
8" TYPE "X" GWB
C.T. WAINSCOT
WET WALLS
5' -0
W
ET
W
AL
LS
C.T. COVE BASE
ENTIRE ROOM
SCALE : N.T.S.
BOTTOM
TRACK
PER SCHEDULE
DECK
U.S. Citizenship and Immigration Services PARTITION TYPE 6
Drawing Name: Sheet #:
W-6 District and Field Office
Design Guide USCIS Facilities Management Division
Version 1.7 - July 2026
PARTITION TYPE 7W7 N/A NIC
8" TYPE "X" GWB
EITHER SIDE
3 58" METAL STUD
@ 24" O.C.
2x2 ACT CEILING
@ 9'-0" HT. MIN.
STAINLESS OR
HIGH IMPACT
VINYL WALL
PROTECTION TO
48" AFF
SCALE : N.T.S.
BOTTOM
TRACK
PER SCHEDULE
FLOORING
PER SCHEDULE
FINISHED
SLAB
MAILROOM CORRIDOR
DECK
U.S. Citizenship and Immigration Services PARTITION TYPE 7
Drawing Name: Sheet #:
W-7 District and Field Office
Design Guide USCIS Facilities Management Division
PARTITION TYPE 8W8
8" TYPE "X" GWB
OUTER LAYER
20ga. 3 58" METAL STUD @ 16" O.C.
3 12" SOUND BATT
INSULATION
20ga. BOTTOM TRACK w/ ACOUSTIC SEALANT
BETWEEN TRACK & FLOOR
2x2 ACT CEILING
@ 9'-0" HT. MIN.
20ga.TOP TRACK w/ ACOUSTIC SEALANT
BETWEEN TRACK & DECK
MINIMIZE HORIZONTAL
PENETRATIONS
ACOUSTIC CAULK ANY
PENETRATIONS
PROVIDE ACOUSTIC
LINERS TO ALL DUCTS,
SECURE ANY OPENINGS >96 s.i.
PAINT VERTICAL
GWB ABOVE
ACT BLACK
NIC 50 min.
SCALE : N.T.S.
FLOORING
PER SCHEDULE
FINISHED
SLAB PER SCHEDULE
4" PLYWOOD
SHEATHING
9-11 SECURITY
CARBON STEEL
MESH, FASTEN 6"
HORIZONTAL &
VERTICAL INTO
PLYWOOD
OUTSIDE OF
SUITE
SECURE SUITE
SIDE
DECK
2" LEVEL 3
BALLISTIC
SHEATHING
U.S. Citizenship and Immigration Services
PARTITION TYPE 8
-SECURE DEMISING WALL-
Drawing Name: Sheet #:
W-8 District and Field Office
Design Guide USCIS Facilities Management Division