6b - Technical Exhibit 3.pdf

PDF 93 KB Posted

Attached to
H312--Maintenance- fire protection systems Federal contract opportunity
Solicitation number
36C25220Q0072
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12

View the file

Other files for this federal contract opportunity

Other files attached to H312--Maintenance- fire protection systems, newest first.
File Type Posted
36C25220Q0072 0002.docx DOCX document
36C25220Q0072 0001.docx DOCX document
Milwaukee_VAMC_Base_Map.pdf PDF
36C25220Q0072_1.docx DOCX document
Wage Determination 2015-4899 Rev 11dated 6-23-2020-Milwaukee.docx DOCX document
6c -Technical Exhibit 4.pdf PDF
6d - Technical Exhibit 5.pdf PDF
6e - Technical Exhibit 6.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 3 - Technical Exhibit 3 Fire Alarm System Data

Fire alarm system component 3 4 5 6 7* 11* 17 20 43 70 97 102 107 108 109** 113** 115** 111 112 123 144 146 147 148 150 151 152 Totals Fire alarm control panel 1 1 1 1 1 0 1 1 1 1 1 1 1 1 0 1 0 4 1 1 1 1 1 1 1 1 1 27 Notification appliance circuit panel 0 0 0 4 2 0 0 0 0 13 0 2 0 0 0 0 0 47 0 14 3 2 2 2 0 0 0 91 Amplifier 0 0 0 0 0 0 0 0 0 2 0 1 0 0 0 0 0 10 0 0 1 1 0 0 0 0 0 15 Pre-action releasing panel 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 0 5 Power extender 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 0 0 0 0 0 0 0 2 Fire alarm dialer 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 1 Annunciator 0 0 0 0 0 1 0 0 0 0 0 0 0 0 1 0 0 3 0 2 1 1 1 1 1 0 0 12 Duct smoke detector 0 0 10 13 0 0 0 0 22 21 0 1 0 0 0 0 0 83 0 7 16 2 2 2 3 0 0 182 Heat detector 0 2 2 3 1 0 3 1 1 2 0 4 0 10 0 0 7 90 2 1 8 4 4 4 4 4 3 160 Smoke detector 7 6 24 30 52 22 25 6 91 82 0 12 0 26 2 4 7 663 4 163 49 24 24 24 45 1 1 1394 Pull station (pull box) 4 6 16 50 19 4 7 14 18 58 3 7 2 3 4 4 0 167 8 23 14 5 5 5 10 0 0 456 Elevators with recall/shunt trip 0 1 1 2 1 0 0 1 2 5 0 0 0 0 0 0 0 12 0 0 3 0 0 0 1 1 0 30 Firefighter telephone equipment 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 118 0 0 0 2 0 0 0 0 1 121 Bell 0 0 0 0 0 0 0 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 Speaker 3 0 0 63 30 0 0 15 20 1 1 0 4 4 0 0 0 64 11 0 70 1 1 1 0 0 0 289 Strobe 3 4 24 68 24 11 4 15 63 8 1 4 4 4 6 1 0 434 11 134 70 1 2 2 12 0 0 910 A/V 0 6 20 3 0 3 10 0 7 156 0 52 0 0 3 1 0 973 0 215 7 34 35 35 30 0 0 1590 Door control 0 0 8 0 4 0 0 0 5 15 0 0 0 0 0 0 0 165 0 11 5 2 1 1 7 0 0 224 Battery testing 2 2 2 10 6 0 2 2 2 34 2 8 2 2 0 2 0 132 2 34 10 8 6 6 2 2 2 282

Notes: *Building 11 is slaved to Building 7's fire alarm control panel **Builidngs 109 and 115 are slaved to Building 113's fire alarm control panel

Building Number

Fire Alarm Data