BIL Funded Materials Electrical Distribution System Refurbishment Project SOW revised 07.08.2024.pdf

PDF 118 KB Posted

Attached to
BIL Funded-Electrical Equipment for Electrical Distribution System Refurbishment Project
Solicitation number
697DCK-24-R-00497
Issued by

About this file

This document is a Statement of Work (SOW) for a federal contract opportunity to procure materials required to refurbish the electrical distribution system at the San Juan CERAP - FMP Yard in Carolina, Puerto Rico. The required materials include replacement of electrical components such as meter bases, distribution panels, surge protectors, lamp fixtures, and various electrical hardware and supplies.

The associated federal contract opportunity is a request for proposal (RFP) issued by the Federal Aviation Administration (FAA) Southwestern Region. This is a set-aside for small disadvantaged businesses, with an anticipated award of a single firm fixed-price contract. Proposals are due by July 26, 2024 at 5:00 PM EDT and must be submitted via email. Questions can be submitted up to July 24, 2024 and will be responded to publicly. The North American Industry Classification System (NAICS) code is 335999 with a small business size standard of 600 employees.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FEDERAL AVIATION ADMINISTRATION SCOPE OF WORK

BIL Funded-Electrical Equipment for Electrical Distribution System

Refurbishment Project San Juan Environmental SSC

FMP Yard Buildings Carr 190 # 5000

Carolina, PR 00979

STATEMENT OF WORK

Material required to replace Meter base, replace main distribution panel with circuit breakers, replace TVSS with a RAYVOSS TVSS, replace Sub-panel D and D-1 with circuit breakers, replace General Duty Disconnect Switches with Heavy Duty Disconnect Switches, (30) replace lamp fixtures located on the exterior walls of the (4) buildings, replace the lamp fixtures (16) located in the office areas, replace (40) lamp fixtures in the interior of each Bay area, used in oil building and Hurricane Shelter.

Materials Required:

(1) Meter Base 200Amps with Main Breaker 200amp

(16) EA LITHONIA (ACUITY) BLT Series LED Luminaire, 2x4, Static, 4000

(40) EA LITHONIA LTG CSVT L48 ALO3 MVOLT SWW3 80CRI

LED 4FT

(30) EA LITHONIA LTG TWX2 LED ALO 40K MVOLT PE

DDBTXD LED WALL 4000K 6500LM 120-277V TXD BRNZ

(20) ABB (THOMAS AND BETTS) Blackburn® Long Barrel

Copper Splice, Copper, Tin-Plated, 350 kcmil, Red

(4) EA B-LINE (EATON) 4-Hole Closed Angle

(200) L. H. DOTTIE 3/8 x 2 in. Zinc Plated Steel Hex Head Tap

Bolts

(200) L. H. DOTTIE Flat Washers, Stainless Steel, 3/8 in.

(200) L. H. DOTTIE

(200) Lock Washers, Zinc Plated Steel, 3/8 in.

(2) IDEAL INDUSTRIES 16 Hole Step Drill Bits

(14) 3M™ Comfort Grip General Gloves, Medium

(4) KLEIN TOOLS Cable Splicer Snip Stainless Steel

(1) GREENLEE Cable Stripper, Ergonomic, 8 AWG to 1250 MCM

THHN and 0.18 to 1.57 in. dia. Cable

(10) Conduit Coupling, Rigid Galvanized, Steel, 1-1/4 in.

(10) Galvanized Rigid Steel Conduit, 1-1/4 in.

(1) GREENLEE Hole Saw Kit, Bi-Metal, 13 pc.

(10) Hal-Sealers™ Hole Seal, 3 pc. Gasketed, Stainless Steel, 3/4 in.

(1) KLEIN TOOLS Large Cable Stripper (2/0-250 MCM)

(1) SQUARED (SCHNEIDER ELECTRIC) Load Centers, Main Lug, 225 A, 120/240 V, 1-Phase Phase, 80, 40, NEMA 1

(2) SQUARED (SCHNEIDER ELECTRIC) IEC Certified QO™

Load Center, Type 1(Indoor), Main Breaker, 200A, Max. 42 Spaces

(6) CROUSE HINDS (EATON) Myers™ Conduit Grounding Hub, Zinc, Insulated, Rigid/IMC Conduit, 1-1/4 in.

(10) ABB (THOMAS AND BETTS) Non-Metallic Red End Cap for use with Series B Channel

(20) BURNDY One Hole Hylug™ Code Conductor Long Barrel, 6

AWG

(10) UNISTRUT P1000 Series Pre-Galvanized Steel Solid Channel, 10 ft., 12 ga.

(1) KLEIN TOOLS Parallel Jaw Grip 4500 Series for ACSR

(40) SQUARED (SCHNEIDER ELECTRIC) QOB Miniature Circuit

Breaker, Bolt On, 1 Pole, 20A, 120/240V, 10kA

(10) LEVITON SmartlockPro® Slim Self-Test GFCI Receptacle, Weather-Resistant, 20A, 125V, Monochromatic, White

(1) 3M Residential Wire Connector, Tan/Yellow, 500 per Jug

(10) KIDDE Smoke Alarm, White, Interconnected Photoelectric, 1

Lithium Ion Battery, 5.59 in. Dia. x 1.91 in. D

(40) CADDY (NVENT) Spring Steel EM-M Series Conduit/Pipe to

Flange Clip For 1/2 or 3/4 in. EMT or Rigid Conduit and 1/8 to 1/4

in. Flange

(10) B-LINE (EATON) Square Post Base, Zinc Plated, 3-1/2 in. H

(40) B-LINE (EATON) Square Washer, zinc plated steel, 1/2 in.

(30) ABB (THOMAS AND BETTS) Steel City® Conduit Bushing, Thermoplastic, Insulated 105° Rigid/IMC Conduit, 3/4 in.

(20) B-LINE (EATON) Steel Strut Beam Clamp, Zinc Plated, 3-3/8

in. Jaw Capacity

(100) ABB (THOMAS AND BETTS) Superstrut® Series Steel

Spring Nut With SilverGalv Finish, 3/8 in.

(10) Hot-Dip Galvanized Steel 90-Degree Rigid Conduit Elbow, 4 in., 24 in. Radius

(8) Hot-Dip Galvanized 4” Rigid Conduit

(16) ABB (THOMAS AND BETTS) Hub Connector, Zinc, Rigid/IMC Conduit, Insulated 105°, 4 in.

(1) FLUKE Non Contact Voltage True-RMS AC/DC Clamp Meter with iFlex

(2) SQUARED (SCHNEIDER ELECTRIC) QOB Miniature Circuit

Breaker, Bolt On, 2 Pole, 60A, 120/240V, 10kA

(1) SQUARED (SCHNEIDER ELECTRIC) QOB Miniature Circuit

Breaker, High Interrupting Capacity, Bolt On, 2 Pole, 125A, 120/240 Vac, 22kA

(18) SQUARED (SCHNEIDER ELECTRIC) QOB Miniature Circuit Breaker, High Interrupting Capacity, Bolt On, 2 Pole, 20A, 120/240 Vac, 22kA

(5) SQUARED (SCHNEIDER ELECTRIC) QOB Miniature Circuit Breaker, High Interrupting Capacity, Bolt On, 2 Pole, 50A, 120/240 Vac, 22kA

(5) SQUARED (SCHNEIDER ELECTRIC) Safety switch, heavy duty, unfused, viewing window, NEMA 3R, 600V, 30A, 3 pole

(40) 10’ CONDUIT 3/4-EMT 3/4-STEEL THINWALL CONDUIT

(40) COOPER CROUSE-HINDS 651S 3/4 EMT CMP CONN

(40) COOPER CROUSE-HINDS 661S 3/4 STL COMP EMT CPLG

(100) COOPER CROUSE-HINDS 201 3/4 1H STL EMT STRAP

(12) COOPER CROUSE-HINDS RAC200HD 2-IN 90D GLV CLMP

(500’) THHN-1/0-SOLBLK THHN/THWN-2 SOL 600V CU

(2) THHN-12-SOLBLK 500S THHN/THWN-2 SOL 600V CU

(2) THHN-12-SOLRED-500S THHN/THWN-2 SOL 600V CU

(2) THHN-12-SOLWHT-500S THHN/THWN-2 SOL 600V CU

(2) THHN-12-SOLGRN-500S THHN/THWN-2 SOL 600V CU

(1) THHN-350MCM-SOLBLK-250S THHN/THWN

(1) Thompson Beard 4/0 100’

(1) TVSS Rayvoss

(4) Short-Barrel Splice: STD Barrel size, Red Color, 350 Kcmil

Max Wire Size. (Grainger Item # 3LM24

(10) Grounding Bushing: Iron, Zinc Plated, 2 in Trade Size

(Granger Item # 2AX6)

(10) Grounding Bushing: Iron, Zinc Plated, 3 in Trade Size

(Granger Item # 3LN9)

(10) One-Hole Lug Compression Connector: 2 AWG Max Wire

Size, 3/8 in Stud Size (Grainger Item # 3LM86)

(20) Wedge Anchor: 6 in Overall Lg, 0.625 in Dia, 5/8” -11 Thread

Size. (Grainger Item # 2U924) Hubbell Connector: Female Connector, 400 A, Brown (Grainger

Item # 20TR8)

(2) Hubbell Connector: Female Connector, 400 A, Yellow

(Grainger Item # 20TR57)

(2) Hubbell Connector: Female Connector, 400 A, Orange

(Grainger Item # 20TR56)

(2) Hubbell Connector: Female Connector, 400 A, Green

(Grainger Item # 2XB37)

(2) Hubbell Receptacle: For Female Connectors, 400A, Straight, Green, Square, Though Hole Mounting (Grainger Item # 2XB7)

(2) Hubbell Receptacle: For Female Connectors, 400A, Straight, Yellow, Square, Though Hole Mounting (Grainger Item # 20TR63)

(2) Hubbell Receptacle: For Female Connectors, 400A, Straight, Orange, Square, Though Hole Mounting (Grainger Item #

20TR62)

(2) Hubbell Receptacle: For Female Connectors, 400A, Straight, Brown, Square, Though Hole Mounting (Grainger Item # 20TR64)

(2) Hubbell Single Pole Connector: 400 A Compatible Device Current, Green. ( Grainger Item # 20TT81)

(2) Hubbell Single Pole Connector: 400 A Compatible Device Current, Orange. ( Grainger Item # 20TT82)

(2) Hubbell Single Pole Connector: 400 A Compatible Device Current, Yellow. ( Grainger Item # 20TT85)

(2) Hubbell Single Pole Connector: 400 A Compatible Device Current, Brown. ( Grainger Item # 20TT80)

CONTACT/LOCATION INFORMATION

A. Location of Work:

San Juan CERAP FMP Yard Buildings

Carr 190 # 5000

B. FAA Point of Contact:

SSC Manager Name: Antonio Torres 787-253- 8979 Address: ZSU CERAP

5000 Carr 190

STATEMENT OF WORK