Tower Foundation Drawing.pdf
PDF 26 KB Posted
- Solicitation number
- 6973GH-19-R-00079
About this file
Tower Foundation Drawing (pdf)
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 6973GH-19-R-00079 0001.pdf | ||
| Questions from contractors.docx | DOCX document | |
| Experience Information Form.pdf | ||
| Existing Tower Guy Anchor and Foundation Details.pdf | ||
| Contractor's Release Form DOT F 4220.4.doc | DOC document | |
| Wage Determination KY180092 as of 1-4-2019.pdf | ||
| Specifications.pdf | ||
| SCOPE of Work.doc | DOC document | |
| Copy of CAI Punchlist.xls | XLS spreadsheet | |
| Construction Drawings.pdf | ||
| SIR 6973GH-19-R-00079 Final.pdf | ||
| Construction Drawings.pdf | ||
| Wage Determination KY180092 as of 1-4-2019.pdf | ||
| Experience Information Form.pdf | ||
| Contractor's Release Form DOT F 4220.4.doc | DOC document | |
| Specifications.pdf | ||
| SIR 6973GH-19-R-00079 Final.pdf | ||
| SCOPE of Work.doc | DOC document |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SkyTower Box 1929
Montrose, CO 81402 Phone: 970-209-0041
FAX: myoung@skytower.biz
Job: West Paducah, KY Project: 120' 100 MPH Tower Client: FAA Drawn by: Mark Young App'd:
Code: TIA-222-G Date: 09/11/18 Scale: NTS Path:
C:\Users\Mark Young\Dropbox\Files\SkyTower Corp\FAA\Master Drawings\3 New STC 120-100 GK\120-100 GK.eri Dwg No. E-1
120.0 ft
100.0 ft
80.0 ft
60.0 ft
40.0 ft
20.0 ft
10.0 ft
5.0 ft
0.0 ft
REACTIONS - 100 mph WIND TORQUE 1 lb-ft
24469 lb
SHEAR
1571281 lb-ft
MOMENT
13234 lb
AXIAL
30 mph WIND - 1.0000 in ICE TORQUE 0 lb-ft
2322 lb
SHEAR
165083 lb-ft
MOMENT
68279 lb
AXIAL
SHEAR: 6399 lb UPLIFT: -170802 lb
SHEAR: 4663 lb DOWN: 162985 lb
MAX. CORNER REACTIONS AT BASE:
ARE FACTORED
ALL REACTIONS
S ec tio n
T1 T2
T3 T4
T5 T6
T7 T8
L eg s L3 x3 x3
/1
L3 x3 x1 /4
L3
/2 x3
/2 x5 /1
L4 x4 x3
/8 L5 x5 x3
/8 L6 x6 x7
/1
L eg
G ra de A
2-
D ia go na ls L1
/2 x1
/2 x1
/8 L2 x2 x1
/8 L2 x2 x3
/1
2L 2x
2x 3/
D ia go na l G ra de A
T op
G irt s L3 x3 x1
/4 N
.A
H or iz on ta ls
N .A
2L
2x 2x
1/
F ac e W id th
(f t)
6.
P an el s
(f t)
.8
.7
.5
W ei gh t ( lb
0.
5.
.7
.3
.5
.5
9.
9.
.1
Platform 120 - 118 BA1010 120 - 118 (2) BA1010 120 - 118 BA1010 120 - 118 (2) BA1010 120 - 118 (2) 7'x2 1/2" Pipe Mount 120 - 118 7'x2 1/2" Pipe Mount 120 - 118 (2) 7'x2 1/2" Pipe Mount 120 - 118 7'x2 1/2" Pipe Mount 120 - 118 RMU (Remote Units) 120 - 118 RMU (Remote Units) 120 - 118 (2) Lightning Rod 120 - 118 DESIGNED APPURTENANCE LOADING
TYPE TYPEELEVATION ELEVATION
Platform 120 - 118
BA1010 120 - 118
(2) BA1010 120 - 118
BA1010 120 - 118
(2) BA1010 120 - 118
(2) 7'x2 1/2" Pipe Mount 120 - 118
7'x2 1/2" Pipe Mount 120 - 118
(2) 7'x2 1/2" Pipe Mount 120 - 118 7'x2 1/2" Pipe Mount 120 - 118 RMU (Remote Units) 120 - 118 RMU (Remote Units) 120 - 118
(2) Lightning Rod 120 - 118
TOWER DESIGN NOTES
1. Tower is located in Mccracken County, Kentucky.
2. Tower designed for Exposure C to the TIA-222-G Standard.
3. Tower designed for a 100 mph basic wind in accordance with the TIA-222-G Standard.
4. Tower is also designed for a 30 mph basic wind with 1.00 in ice. Ice is considered to increase in thickness with height.
5. Deflections are based upon a 60 mph wind.
6. Tower Structure Class III.
7. Topographic Category 1 with Crest Height of 0.00 ft
8. Weld together tower sections have flange connections.
9. Connections use galvanized A325 bolts, nuts and locking devices. Installation per TIA/EIA-222 and AISC Specifications.
10. Tower members are "hot dipped" galvanized in accordance with ASTM A123 and ASTM A153 Standards.
11. Welds are fabricated with ER-70S-6 electrodes.
12. TOWER RATING: 99.9%
Company : SkyTower Corp September 11, 2018 Designer : Mark Young
120' 100 MPH TowerJob Number : Checked By:_____
Sketch
23 ft f t
8.25 ft f t
78 in i n
A B
CD
x z 5 i n
CD
Details x z
A B
CD
#8@15 in
23 ft f t
#8@15 in
Bottom Rebar Plan i n i n i n
CD Footing Elevation
A B
CD
#8@15 in
23 ft f t
#8@15 in x Dir. Steel: 14.14 in2 (18 #8) z Dir. Steel: 14.14 in2 (18 #8)
Top Rebar Plan
Geometry, Materials and Criteria Length : eX : Net Allowable Bearing : Steel fy :
Width : eZ : Concrete Weight : Minimum Steel :
Thickness : pX : Concrete f'c : Maximum Steel :
Height : pZ : Design Code :
Footing Top Bar Cover : Overturning / Sliding SF : Phi for Flexure :
Footing Bottom Bar Cover : Coefficient of Friction : Phi for Shear :
Pedestal Longitudinal Bar Cover : Passive Resistance of Soil : Phi for Bearing :
23 ft 0 in 2300 psf (net) 60 ksi 23 ft 0 in 145 pcf .0018 54 in 78 in 3 ksi .0075 0 in 78 in ACI 318-05
3 in 1.5 0.9 3 in 0.3 0.75 3 in 0 k 0.65
RISAFoot Version 4.00 [C:\...\...\...\...\...\...\...\...\Gravity Block.rft] Page 1
Mark Young Typewritten Text
PB