QUESTIONS AND ANWSERS that need to be attached to the SIR on FAACO
1. MTO-D-VOR C001 has a note to remove the metal roof. There are no other notes or details regarding this that I can find in the plans or SOW, could you please clarify intent or scope?
The whole facility shall be demolished. The Antenna or “TeePee” on top of the roof is to be carefully removed and returned to the SSC. All else shall be disposed of.
2. Are their details or spec for the new concrete staircase?
The dimensions to the concrete steps are shown in drawing MTO-D-RCO-C002. It can be precast or cast in place with 5 #4 bent bars equally spaced and #4 horizontal bars spaced at 12” O.C.
3. Are there any site pictures available?
See attached