6933A220Q000005 - Attachment 0003 Revised Quote Pricing Sheet.xlsx

XLSX spreadsheet 416 KB Posted

Attached to
T. S. KENNEDY - FY20 Drydocking Repairs and ABS Intermediate Survey
Solicitation number
6933A220Q000005-0003
Issued by

About this file

This is a quote pricing sheet and solicitation for drydocking repairs and an ABS intermediate survey of the T.S. Kennedy. The solicitation was issued by the Department of Transportation Maritime Administration and seeks quotes for repairs and inspections to be completed during the drydocking of the T.S. Kennedy in fiscal year 2020. The quote pricing sheet breaks down pricing for general services, drydocking requirements, repair items, and optional and unit priced items. Pricing is provided for tasks such as internal structural exams and testing of fuel and ballast tanks, steel and piping renewals, and optional items like supplemental labor and material. The total proposed price is $80,000 which includes $80,000 for optional supplemental material. The quote due date was extended to February 4, 2020.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Quote Pricing Sheet

6933A220Q000005 Amendment 0003
ATTACHMENT 1 - QUOTE PRICING SHEET
T.S. KENNEDY - FY20 DRYDOCK REPAIRS
ITEMDESCRIPTION OF SERVICESManHours/QuantityUnitRateAmountMaterialTotal
100SECTION 100: GENERAL SERVICES REQUIREMENTS
101APPLICABILITY OF RULES AND REGULATION
102ACCURACY OF INFORMATION
103SECURITY$ - 0$ - 0
104FIRE PROTECTION AND SAFETY$ - 0$ - 0
105OFFICE AND ADMINISTRATIVE SERVICES$ - 0$ - 0
106WHARFAGE$ - 0$ - 0
107SURVEYS AND INSPECTIONS
108ON-SITE CONTRACTOR'S REPRESENTATIVE
109DOCUMENTATION OF OPENINGS, BLANKS AND PLUGS$ - 0$ - 0
110ALLOWANCE FOR SCRAP MATERIAL
111MAINTAIN SHIP'S LIGHTING$ - 0$ - 0
112HAZARDOUS MATERIALS IDENTIFICATION AND DISPOSAL (See MCL.H-2 Supplemental Work Requests)
113USE OF SHIP'S PARTS AND EQUIPMENT
114PROVIDE SHORE POWER - ELECTRICAL CONSUMPTION- @ $________per KWH300,000kWh$ - 0$ - 0
0114-1PROVIDE SERVICE TO CONNECT$ - 0$ - 0
0114-2PROVIDE SERVICE TO REMOVE$ - 0$ - 0
115DISABLE CO2 AND HALON SYSTEMS.$ - 0$ - 0
116MAINTAINING SHIP'S CLEANLINESS$ - 0$ - 0
117MAINTAIN CLEAN BILGES AND DRAIN WELLS$ - 0$ - 0
118PROTECTIVE FLOOR COVERING$ - 0$ - 0
119SURFACE PREPARATION AND PAINTING/COATING GUIDELINE
120SAFE FOR ENTRY AND SAFE FOR HOT WORK CERTIFICATES$ - 0$ - 0
121PRODUCTION REPORTING$ - 0$ - 0
122CRANE SERVICE$ - 0$ - 0
123STAGING
124OIL BOOM$ - 0$ - 0
125WELDING / BRAZING PROCEDURES
126SOUNDINGS$ - 0$ - 0
127SANITARY SYSTEM$ - 0$ - 0
128WASTE WATER AND OILSGal.$ - 0$ - 0
129SHORE STEAMday$ - 0$ - 0
130PORTABLE TOILETS/TEMPORARY FACILITIES$ - 0$ - 0
SUBTOTAL - SECTION 100$ - 0
200SECTION 200: DRYDOCKING REQUIREMENTS
201DRY DOCK SHIP$ - 0$ - 0
202TAILSHAFT EXAMINATION$ - 0$ - 0
0202-01OPTION - TAILSHAFT EXAMINATION - SHAFT WITHDRAWAL$ - 0$ - 0
203OPEN AND INSPECT LINE SHAFT BEARINGS$ - 0$ - 0
204RUDDER PINTLE CLEARANCES$ - 0$ - 0
205RUDDER TEST$ - 0$ - 0
206SEA CHESTS$ - 0$ - 0
207SEA VALVES$ - 0$ - 0
208BLASTING & COATING OF HULL$ - 0$ - 0
209ULTRASONIC THICKNESS GAUGINGS$ - 0$ - 0
210PROPELLER CLEANING AND INSPECTION$ - 0$ - 0
211INTERNAL STRUCTURAL EXAMS AND TESTING OF IFO 180 FUEL TANKS.
0211-1FO Settler Port Capacity, 736 bbl, Fames 119-128$ - 0$ - 0
0211-2FO settler Stbd Capacity, 736 bbls Location frames 119-128$ - 0$ - 0
0211-3Aux Machinery Rm Day tank Capacity 100 bbls Location frames 117-119$ - 0$ - 0
0211-4DB 3 Inbd Port Capacity 580. bbls Location frames 66-92$ - 0$ - 0
0211-5DB 3 Inbd Stbd Capacity 598 bbls Location frames 66-92$ - 0$ - 0
0211-6DB 3 Outbd Port Capacity 802 bbls Location frames 66-92$ - 0$ - 0
0211-7DB 3 Outbd Stbd Capacity 802 bbls Location frames 66-92$ - 0$ - 0
0211-8DB 4 Outbd Port Capacity 1198 bbls Location frames 92-119$ - 0$ - 0
0211-9DB 4 Outbd Stbd Capacity 1198 bbls Location frames 92-119$ - 0$ - 0
0211-10DB 5 Fwd Ctr (slops - remove and dispose) Capacity 496 bbls Location frames 120-129$ - 0$ - 0
0211-11DB 5 Fwd Port Capacity 394 bbls Location frames 119-129$ - 0$ - 0
0211-12DB 5 Fwd Stbd Capacity 394 bbls Location frames 119-129$ - 0$ - 0
0211-13Deep Tank II Fwd Capacity 1430 bbls Location frames 22-33$ - 0$ - 0
0211-14Deep tank II Aft Capacity 1716 bbls Location frames 33-42$ - 0$ - 0
0211-15Deep Tank V Port Capacity 1134 bbls Location frames 171-187$ - 0$ - 0
0211-16Deep Tank V Stbd Capacity 980 bbls Location frames 171-187$ - 0$ - 0
212INTERNAL STRUCTURAL EXAMS OF SALT WATER BALLAST TANKS
0212-1Forepeak (fresh water), Capacity 150 stem-14$ - 0$ - 0
0212-2DB 2 Port Capacity 101 Location 42-46$ - 0$ - 0
0212-3DB 2 Stbd Capacity 101 Location 42-46$ - 0$ - 0
0212-4DB 6 Port Capacity 189 Location 140-171$ - 0$ - 0
0212-5DB 6 Stbd Capacity 190 Location 140-171$ - 0$ - 0
0212-6Aftpeak (freshwater) Capacity 196 Location 196-212$ - 0$ - 0
0212-7Double Bottom #4 Port, Location 92-119, mud balast open for coupon inspection only$ - 0$ - 0
0212-8Double Bottom #4 Port, Location 92-119, mud balast open for coupon inspection only$ - 0$ - 0
213INTERNAL STRUCTURAL EXAMS OF FEED WATER TANKS
0213-1DB 5 aft ctr Capacity 65 Location 130-139$ - 0$ - 0
0213-2DB 5 aft Port Capacity 43 Location 130-139$ - 0$ - 0
0213-3DB 5 Aft Stbd Capacity 36 Location 130-139$ - 0$ - 0
0213-4Distilled Water Stbd Capacity 11 Location 140-171$ - 0$ - 0
0213-5Distilled Water Port Capacity 11 Location 110-122$ - 0$ - 0
214INTERNAL STRUCTURAL EXAMS OF POTABLE WATER TANKS
0214-1Potable Stbd (upper 'tween deck) Capacity 40 Location 119-125$ - 0$ - 0
0214-2Deep Tank III Port Capacity 308 Location 140-157$ - 0$ - 0
0214-3Deep Tank III Stbd Capacity 288 Location 140-157$ - 0$ - 0
0214-4Deep Tank IV Port (sewage modification tank) Capacity 162 Location 158-171$ - 0$ - 0
0214-5Deep Tank IV Stbd (sewage ank modification) Capacity 147 Location 158-171$ - 0$ - 0
0214-6AMR Sewage lift station, Capacity 1550 gallons, Location frame 100-110$ - 0$ - 0
0214-7Engine room Sewage lift station, Capacity 500 gallons, Location frame 130-132$ - 0$ - 0
0214-8#6 hold Sewage lift station, Capacity 600 gallons, Location frame 172-175$ - 0$ - 0
215INTERNAL STRUCTURAL EXAMS OF VOIDS AND COFFERDAMS
0215-1FWD Engine room Cofferdam Location 119-120$ - 0$ - 0
0215-2Mid Engine room cofferdam Location 129-130$ - 0$ - 0
0215-3ECHO Sounding Void Space Location 66-68$ - 0$ - 0
0215-4Shaft Alley Void Space Port (cofferdam) Location 157-158$ - 0$ - 0
0215-5Aft Engine Room Cofferdam Location 134-140$ - 0$ - 0
0215-6Shaft Alley Void Space STBD Location 157-158$ - 0$ - 0
0215-7Shaft Alley void space STBD- cofferdam Location 171-172$ - 0$ - 0
0215-8Shaft Alley Void Space Port – cofferdam Location 171-172$ - 0$ - 0
0215-9Aft Void Space Location 187-196$ - 0$ - 0
0215-10Pipe Tunnel, Location 42 to 132$ - 0$ - 0
0215-11DP Tank IV Port cofferdam Location 158-171$ - 0$ - 0
0215-12DP Tank IV Stbd cofferdam Location 158-171$ - 0$ - 0
0215-13DP Tank III Stbd cofferdam Location 140-157$ - 0$ - 0
0215-14DP Tank III Port cofferdam Location 140-157$ - 0$ - 0
216INTERNAL STRUCTURAL EXAMS AND TESTING OF DIESEL OIL TANKS
0216-1AMR Diesel Tank(gallons) Capacity 985 Location 106-107$ - 0$ - 0
0216-2EDG Diesel Tank Capacity 878 Location 112-114$ - 0$ - 0
217INTERNAL STRUCTURAL EXAMS AND TESTING OF AMR SLUDGE TANK
0217-1AMR Sludge Tank Capacity 405 Location 114-116$ - 0$ - 0
218FATHOMETER TRUNKS AND SPEED LOG$ - 0$ - 0
219ANCHOR CHAINS & LOCKERS$ - 0$ - 0
220ZINC ANODES$ - 0$ - 0
221CATHODIC PROTECTION SYSTEM$ - 0$ - 0
222BOW THRUSTER$ - 0$ - 0
223BILGE COATINGS$ - 0$ - 0
224MUD BALLAST INSPECTION$ - 0$ - 0
225RIVETS$ - 0$ - 0
SUBTOTAL - SECTION 200$ - 0
300SECTION 300: REPAIR ITEMS
301CROP AND RENEW MICISELANIOUS PIPING AND STRUCTURE IN THE ENGINE ROOM$ - 0$ - 0
302CROP AND RENEW MICISELANIOUS SECTIONS OF CAP RAIL, BULWARKS AND MINOR STEEL STRUCTURE ON THE WEATHERDECKS$ - 0$ - 0
303CROP AND RENEW VARIOUS OVERBOARD HULL CONNECTIONS INCLUDING THE PIPE, FLANGE AND GUSSETS.$ - 0$ - 0
304INSTALL NEW DOPPLER SPEED LOG, CONTRACTOR FURNISHED FURUNO, MODEL: DS-80$ - 0$ - 0
305PIPING RENEWALS- SEA CHEST VENTS$ - 0$ - 0
306REPAIR OR REPLACE NAV LAB AC VENT PORT SIDE OF NAV LAB$ - 0$ - 0
307OVERHAUL WARPING WINCH$ - 0$ - 0
308CANCELED ITEM$ - 0
309STEEL RENEWALS- AFTER PEAK TANK AND STEERING GEAR FLAT$ - 0$ - 0
310STEEL RENEWALS- PORT SEA CHEST FRAME 129-130$ - 0$ - 0
311STEEL RENEWALS, ENGINE ROOM FWD COFFERDAM AND TANK TOP$ - 0$ - 0
312STEEL RENEWALS, FORE PEAK TANK AND CHAIN LOCKER$ - 0$ - 0
SUBTOTAL - SECTION 300$ - 0
400SECTION 400: OPTIONAL AND UNIT PRICED ITEMS
401OPTION - MOVE SHIP FROM PILOT STATION AND PLACE IN DRY DOCK$ - 0$ - 0
402OPTION - SHIFT TO WET LAYBERTH FOLLOWING DRY DOCKING$ - 0$ - 0
403OPTION - PROVIDE WET LAY BERTH10DAY$ - 0$ - 0
404OPTION - SUPPLEMENTAL LABOR1200HRS$ - 0$ - 0
405OPTION - SUPPLEMENTAL MATERIAL$ - 0$ 80,000.00$ 80,000.00
406OPTION - SUPPLEMENTAL STEEL
0406-1KTR Provide A Quote for Estimated 5,000 lbs of Flat Steel5000LBS$ - 0$ - 0
0406-2KTR Provide A Quote for Estimated 2,000 lbs of Rolled Steel2000LBS$ - 0$ - 0
0406-3KTR provide a quotation to weld 20 rivets.20EA$ - 0$ - 0
0406-4KTR provide a quotation to renew 60 rivets.60EA$ - 0$ - 0
0406-5KTR provide a quotation to prep and re-weld external hull weld seams, of an estimated length of 100 feet of weld.100FT$ - 0$ - 0
407OPTION - BOW THRUSTER REFURBISHMENT$ - 0$ - 0
408OPTION - ULTRASONIC GAUGINGS ADDITIONAL5UNIT$ - 0$ - 0
409OPTION - SWITCHBOARDS, LOAD CENTERS/POWER PANELS; CLEAN, INSPECT AND REPAIR$ - 0$ - 0
410OPTION - REPLACE RUBBER SCUPPER EXTENSIONS$ - 0$ - 0
411OPTION - CROP AND RENEW HAND RAILS, STANCHIONS AND SEA-RAILS$ - 0
0411-1Top Railing (1-1/4” pipe)150FT$ - 0$ - 0
0411-2Middle and Bottom railing (3/4” pipe)”300FT$ - 0$ - 0
0411-3Sea-Rail (1-1/4” pipe)90FT$ - 0$ - 0
412OPTION - CROP AND RENEW FOUNDATIONS, STANTIONS AND PIPE STOOLS
0412-01Pipe stools between 1” and 5”50EA$ - 0$ - 0
0412-02Stanchions (2”x2” up to 4”x4”x 12” long) angle iron10EA$ - 0$ - 0
0412-03Foundations (4”x4” up to 6”x6”x 12” long)5EA$ - 0$ - 0
413OPTION - ASBESTOS ABATEMENT, MAIN FEED WATER TO THE ECONIMIZER ON BOTH BOILERS AND REINSULATION$ - 0$ - 0
414OPTION - REPLACE SALT WATER FLUSHING PIPING LISTED ON THE ATTACHED REFRENCES WITH CuNi$ - 0$ - 0
415OPTION - TANK VENT OVERHAUL$ - 0$ - 0
416OPTION - REPAIR FIBREGLASS SHOWER PANS IN RATE ROOMS$ - 0$ - 0
417OPTION - HYDROTORQUE HINGE INSTALLATION$ - 0$ - 0
418OPTION - OVERHAUL TWO (2) SHIPS SERVICE TURBINE GENERATOR GLAND SEAL REGULATORS$ - 0$ - 0
419OPTION - FORE PEAK TANK PRESERVATION$ - 0$ - 0
420OPTION - AFTER PEAK TANK PRESERVATION$ - 0$ - 0
TotalSUBTOTAL - SECTION 400 OPTION ITEMS$ 80,000.00
SECTION 100: GENERAL SERVICES REQUIREMENTS$ - 0
SECTION 200: DRYDOCKING REQUIREMENTS$ - 0
SECTION 300: REPAIR ITEMS$ - 0
SECTION 400: OPTIONAL AND UNIT PRICED ITEMS$ 80,000.00
DRYDOCK TOTAL$ 80,000.00

File details come from the government source that posted it. Updated .