About this file

This document is a Request for Quotation (RFQ) for a Supplemental Phase II Environmental Site Assessment, Risk-Based Cleanup and Disposal Plan, and Risk Characterization Sampling at 495 Dorchester Avenue in Boston, MA. The U.S. Department of Transportation, John A. Volpe National Transportation Systems Center (Volpe Center) is providing support to the U.S. Environmental Protection Agency (EPA) Targeted Brownfields Assessments (TBA) program for this effort. The contract will be a firm-fixed price purchase order with a period of performance from date of award through 12/31/2024. The NAICS code is 238910 with a $19.0M small business size standard. Offerors must provide a firm-fixed price quote on the attached Statement of Work and complete required representations via SAM.gov. The Government will not pay for any information received.

View the file

Other files for this federal contract opportunity

Other files attached to Supplemental Phase II Environmental Site Assessment, Risk-Based Cleanup and Disposal Plan, and Risk Characterization Sampling, newest first.
File Type Posted
6 - Questions and Answers Documentdocx.pdf PDF
3 - 495_DotAve_DrillerSOW_8-27-24_Revised_3.pdf PDF
5 - Sam.Gov - Wage Determination.pdf PDF
1 - Instructions to Offerors and Evaluation Criteria.pdf PDF
4 - SAP Commercial Terms and Conditions.pdf PDF
2 - Request for Quote (Line Items).pdf PDF
3 - 495_DotAve_DrillerSOW_8-23-24_Revised.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Table 1 - Soil Samples

495 Dorchester Ave TBA Sampling Scope - Soil Boring & Soil Sampling
on map?Location495 Dorchester Ave Data GapSample ID
(Gray = HOLD pending other results)Drill Depth
(ft bgs)Sample Interval(s)
(ft bgs)Number of Samples
Proposed for AnalysisNumber of Samples

to HOLD -

pending resultsLaboratory AnalysisNOTESInternal NotesVolpe Internal Notesn staffDayScope
y10ft NW of C29C29 CVOC ImpactsV-495D-VOC-C29-10NW (6-8)

V-495D-VOC-C29-10NW (8-10)

V-495D-VOC-C29-10NW (10-12.6) 12.6 6-8

8-10

10-12.63-VOCs--15ft below final grade in this location is El. 5ft. Current GS is El. 17.6ft. Collect 2-ft interval samples from 6ft below current grade (El. 11.6ft) down to El. 5ft (12.6ft below current grade).1Targeted Contaminant Investigation Locations
y10ft NE of C29C29 CVOC ImpactsV-495D-VOC-C29-10NE (6-8)

V-495D-VOC-C29-10NE (8-10)

V-495D-VOC-C29-10NE (10-12.6) 12.6 6-8

8-10

10-12.63-VOCs--1
y10ft SW of C29C29 CVOC ImpactsV-495D-VOC-C29-10SW (6-8)

V-495D-VOC-C29-10SW (8-10)

V-495D-VOC-C29-10SW (10-12.6) 12.6 6-8

8-10

10-12.63-VOCs--1
y10ft SE of C29C29 CVOC ImpactsV-495D-VOC-C29-10SE (6-8)

V-495D-VOC-C29-10SE (8-10)

V-495D-VOC-C29-10SE (10-12.6) 12.6 6-8

8-10

10-12.63-VOCs--1
yE20I21 NAPL ExtentV-495D-PET-E20-B (insert sample interval ft bgs)
V-495D-PET-E20-B (insert sample interval ft bgs)20.5Based on field observations
(see notes).2-TPHCollect 2-foot discrete samples. One sample from the interval with the highest PID screening and/or observed evidence of petroleum from between El. 10.0 and 0.0 ft BCB, and one sample from the interval where PID screening and/or observed petroleum impacts appear to reduce/clean up. If sheen or PID reading >100 ppm is observed at the bottom of the boring, continue drilling until sheen is not longer observed and/or PID reading is <100 ppm. Characterize soil starting from grade.
yE22I21 NAPL ExtentV-495D-PET-E22-B (insert sample interval ft bgs)
V-495D-PET-E22-B (insert sample interval ft bgs)20.5Based on field observations
(see notes).2-TPHCollect 2-foot discrete samples. One sample from the interval with the highest PID screening and/or observed evidence of petroleum from between El. 10.0 and 0.0 ft BCB, and one sample from the interval where PID screening and/or observed petroleum impacts appear to reduce/clean up. If sheen or PID reading >100 ppm is observed at the bottom of the boring, continue drilling until sheen is not longer observed and/or PID reading is <100 ppm. Characterize soil starting from grade.
yG20I21 NAPL ExtentV-495D-PET-G20-B (insert sample interval ft bgs)
V-495D-PET-G20-B (insert sample interval ft bgs)21Based on field observations
(see notes).2-TPHCollect 2-foot discrete samples. One sample from the interval with the highest PID screening and/or observed evidence of petroleum from between El. 10.0 and 0.0 ft BCB, and one sample from the interval where PID screening and/or observed petroleum impacts appear to reduce/clean up. If sheen or PID reading >100 ppm is observed at the bottom of the boring, continue drilling until sheen is not longer observed and/or PID reading is <100 ppm. Characterize soil starting from grade.
yG23I21 NAPL ExtentV-495D-PET-G23-B (insert sample interval ft bgs)
V-495D-PET-G23-B (insert sample interval ft bgs)21Based on field observations
(see notes).2-TPHCollect 2-foot discrete samples. One sample from the interval with the highest PID screening and/or observed evidence of petroleum from between El. 10.0 and 0.0 ft BCB, and one sample from the interval where PID screening and/or observed petroleum impacts appear to reduce/clean up. If sheen or PID reading >100 ppm is observed at the bottom of the boring, continue drilling until sheen is not longer observed and/or PID reading is <100 ppm. Characterize soil starting from grade.
yI21I21 NAPL ExtentV-495D-PET-I21-B (insert sample interval ft bgs)
V-495D-PET-I21-B (insert sample interval ft bgs)21Based on field observations
(see notes).2-TPHCollect 2-foot discrete samples. One sample from the interval with the highest PID screening and/or observed evidence of petroleum from between El. 10.0 and 0.0 ft BCB, and one sample from the interval where PID screening and/or observed petroleum impacts appear to reduce/clean up. If sheen or PID reading >100 ppm is observed at the bottom of the boring, continue drilling until sheen is not longer observed and/or PID reading is <100 ppm. Characterize soil starting from grade.
yJ20I21 NAPL ExtentV-495D-PET-J20-B (insert sample interval ft bgs)
V-495D-PET-J20-B (insert sample interval ft bgs)21Based on field observations
(see notes).2-TPHCollect 2-foot discrete samples. One sample from the interval with the highest PID screening and/or observed evidence of petroleum from between El. 10.0 and 0.0 ft BCB, and one sample from the interval where PID screening and/or observed petroleum impacts appear to reduce/clean up. If sheen or PID reading >100 ppm is observed at the bottom of the boring, continue drilling until sheen is not longer observed and/or PID reading is <100 ppm. Characterize soil starting from grade.
yH28CVOC Extents in PeatV-495D-CVOC-H28 (insert sample interval ft bgs)~20Based on field observations
(see notes).-1VOCs &
SPLP (TCE, PCE, vinyl chloride, & cis-1,2-DCE)HOLD - Pending results.
Collect 2-foot discrete sample. Sample only the peat interval. If the peat interval is observed greater than 3 ft thick, collect two discrete samples. If peat is not observed, collect sample from the interval with the highest PID result between El. 5 and -5 ft.Notes column says we will need to potentially account for 2 optional samples. Chat w/ team
yH30CVOC Extents in PeatV-495D-CVOC-H30-A (insert sample interval ft bgs)~20Based on field observations
(see notes).-1VOCs &
SPLP (TCE, PCE, vinyl chloride, & cis-1,2-DCE)HOLD - Pending results.

Collect 2-foot discrete sample. Sample only the peat interval. If the peat interval is observed greater than 3 ft thick, collect two discrete samples. If peat is not observed, collect sample from the interval with the highest PID result between El. 5 and -5 ft.

yH32CVOC Extents in PeatV-495D-CVOC-H32-A (insert sample interval ft bgs)~20Based on field observations
(see notes).-1VOCs &
SPLP (TCE, PCE, vinyl chloride, & cis-1,2-DCE)HOLD - Pending results.

Collect 2-foot discrete sample. Sample only the peat interval. If the peat interval is observed greater than 3 ft thick, collect two discrete samples. If peat is not observed, collect sample from the interval with the highest PID result between El. 5 and -5 ft.

yI28CVOC Extents in PeatV-495D-CVOC-I28-B (insert sample interval ft bgs)~20Based on field observations
(see notes).1-VOCs &
SPLP (TCE, PCE, vinyl chloride, & cis-1,2-DCE)Collect 2-foot discrete sample. Sample only the peat interval. If the peat interval is observed greater than 3 ft thick, collect two discrete samples. If peat is not observed, collect sample from the interval with the highest PID result between El. 5 and -5 ft.
yI30CVOC Extents in PeatV-495D-CVOC-I30 (insert sample interval ft bgs)~20Based on field observations
(see notes).1-VOCs &
SPLP (TCE, PCE, vinyl chloride, & cis-1,2-DCE)Collect 2-foot discrete sample. Sample only the peat interval. If the peat interval is observed greater than 3 ft thick, collect two discrete samples. If peat is not observed, collect sample from the interval with the highest PID result between El. 5 and -5 ft.
yI32CVOC Extents in PeatV-495D-CVOC-I32 (insert sample interval ft bgs)~20Based on field observations
(see notes).1-VOCs &
SPLP (TCE, PCE, vinyl chloride, & cis-1,2-DCE)Collect 2-foot discrete sample. Sample only the peat interval. If the peat interval is observed greater than 3 ft thick, collect two discrete samples. If peat is not observed, collect sample from the interval with the highest PID result between El. 5 and -5 ft.
yJ30CVOC Extents in PeatV-495D-CVOC-J30-A (insert sample interval ft bgs)~20Based on field observations
(see notes).1-VOCsCollect 2-foot discrete sample. Sample only the peat interval. If the peat interval is observed greater than 3 ft thick, collect two discrete samples. If peat is not observed, collect sample from the interval with the highest PID result between El. 5 and -5 ft.
yJ33CVOC Extents in PeatV-495D-CVOC-J33 (insert sample interval ft bgs)~20Based on field observations
(see notes).1-VOCs &
SPLP (TCE, PCE, vinyl chloride, & cis-1,2-DCE)Collect 2-foot discrete sample. Sample only the peat interval. If the peat interval is observed greater than 3 ft thick, collect two discrete samples. If peat is not observed, collect sample from the interval with the highest PID result between El. 5 and -5 ft.
yJ34CVOC Extents in PeatV-495D-CVOC-J34 (insert sample interval ft bgs)~20Based on field observations
(see notes).-1VOCs &
SPLP (TCE, PCE, vinyl chloride, & cis-1,2-DCE)HOLD - Pending results.

Collect 2-foot discrete sample. Sample only the peat interval. If the peat interval is observed greater than 3 ft thick, collect two discrete samples. If peat is not observed, collect sample from the interval with the highest PID result between El. 5 and -5 ft.

yK30CVOC Extents in PeatV-495D-CVOC-K30-B (insert sample interval ft bgs)~20Based on field observations
(see notes).1-VOCsCollect 2-foot discrete sample. Sample only the peat interval. If the peat interval is observed greater than 3 ft thick, collect two discrete samples. If peat is not observed, collect sample from the interval with the highest PID result between El. 5 and -5 ft.
yK31/32CVOC Extents in PeatV-495D-CVOC-K31/32 (insert sample interval ft bgs)~20Based on field observations
(see notes).1-VOCsCollect 2-foot discrete sample. Sample only the peat interval. If the peat interval is observed greater than 3 ft thick, collect two discrete samples. If peat is not observed, collect sample from the interval with the highest PID result between El. 5 and -5 ft.
yL33CVOC Extents in PeatV-495D-CVOC-L33 (insert sample interval ft bgs)~20Based on field observations
(see notes).1-VOCs &
SPLP (TCE, PCE, vinyl chloride, & cis-1,2-DCE)Collect 2-foot discrete sample. Sample only the peat interval. If the peat interval is observed greater than 3 ft thick, collect two discrete samples. If peat is not observed, collect sample from the interval with the highest PID result between El. 5 and -5 ft.
yL34CVOC Extents in PeatV-495D-CVOC-L34 (insert sample interval ft bgs)~20Based on field observations (see notes).-1VOCs &
SPLP (TCE, PCE, vinyl chloride, & cis-1,2-DCE)HOLD - Pending results.

Collect 2-foot discrete sample. Sample only the peat interval. If the peat interval is observed greater than 3 ft thick, collect two discrete samples. If peat is not observed, collect sample from the interval with the highest PID result between El. 5 and -5 ft.

yM/N35CVOC Extents in PeatV-495D-CVOC-M/N35 (insert sample interval ft bgs)~20Based on field observations
(see notes).1-VOCs &
SPLP (TCE, PCE, vinyl chloride, & cis-1,2-DCE)Collect 2-foot discrete sample. Sample only the peat interval. If the peat interval is observed greater than 3 ft thick, collect two discrete samples. If peat is not observed, collect sample from the interval with the highest PID result between El. 5 and -5 ft.
yM31CVOC Extents in PeatV-495D-CVOC-M31-C (insert sample interval ft bgs)~20Based on field observations
(see notes).1-VOCsCollect 2-foot discrete sample. Sample only the peat interval. If the peat interval is observed greater than 3 ft thick, collect two discrete samples. If peat is not observed, collect sample from the interval with the highest PID result between El. 5 and -5 ft.
yN33CVOC Extents in PeatV-495D-CVOC-N33 (insert sample interval ft bgs)~20Based on field observations
(see notes).1-VOCs &
SPLP (TCE, PCE, vinyl chloride, & cis-1,2-DCE)Collect 2-foot discrete sample. Sample only the peat interval. If the peat interval is observed greater than 3 ft thick, collect two discrete samples. If peat is not observed, collect sample from the interval with the highest PID result between El. 5 and -5 ft.
yN34CVOC Extents in PeatV-495D-CVOC-N34-A (insert sample interval ft bgs)~20Based on field observations
(see notes).-1VOCs &
SPLP (TCE, PCE, vinyl chloride, & cis-1,2-DCE)HOLD - Pending results.

Collect 2-foot discrete sample. Sample only the peat interval. If the peat interval is observed greater than 3 ft thick, collect two discrete samples. If peat is not observed, collect sample from the interval with the highest PID result between El. 5 and -5 ft.

y Adjacent to well MW-14DR Cyanide Impacts in Soil as potential source to GW V-MW-14DR (insert sample interval ft bgs) 29.5 9.5-12.5 12.5-15.5 15.5-18.5 18.5-21.5 21.5-24.5 24.5-27.5

27.5-29.57-PAC CyanideSampling intervals may be adjusted based on field observersations (do not mix strata).
Number of samples may change based on field observations.GS @ MW-14DR = El. 17.5ft.

Sampling from El 8 (bottom of current cut) to El. -12 ft (bottom of impacted well screen) Sampling from 9.5 to 29.5 ft bgs.

20ft of soil to be sampled.

MW-14DRs screen interval is from approx. El. -6 to -11ft. AUL cut in this area is to El. 8 ft.2
y10ft NW of well MW-14DRCyanide Impacts in Soil as potential source to GWV-MW-14DR-10NW (insert sample interval ft bgs)29.5Match sample intervals from soil boring "V-(MW-14DR)"-7PAC CyanideHOLD - Pending results2
y10ft NE of well MW-14DRCyanide Impacts in Soil as potential source to GWV-MW-14DR-10NE (insert sample interval ft bgs)29.5Match sample intervals from soil boring "V-(MW-14DR)"-7PAC CyanideHOLD - Pending results2
y10ft SW of well MW-14DRCyanide Impacts in Soil as potential source to GWV-MW-14DR-10NW (insert sample interval ft bgs)29.5Match sample intervals from soil boring "V-(MW-14DR)"-7PAC CyanideHOLD - Pending results2
y10ft SE of well MW-14DRCyanide Impacts in Soil as potential source to GWV-MW-14DR-10NW (insert sample interval ft bgs)29.5Match sample intervals from soil boring "V-(MW-14DR)"-7PAC CyanideHOLD - Pending results2
yK30MCP Risk SampleV-495D-MCP-K30-B (20.5-22.5)22.520.5-22.51-EPH carbon fractions

VPH carbon fractions VOCs SVOCs MCP 14 Total Metals PAC Cyanide

Total Solids--Supplemental MCP Risk Sampling and Hot Spot Evaluations
yC33Supplemental MCP Risk Data - PAC CyanideV-495D-MCP-C33-A (7-9)97-91-PAC CyanideProposed depth intervals based on anticipated generalized remedial excavation cuts by the Contractor, subject to change.C33 GS = El. 16.8. Cuts to 15.5, 14.6, 11.7, 11.6. Collect sample from El 10-8ft (6.8-8.8ft). Round to 7-9ft bgs.
yC35Supplemental MCP Risk Data - PAC CyanideV-495D-MCP-C35-B (7.5-9.5)9.57.5-9.51-PAC CyanideProposed depth intervals based on anticipated generalized remedial excavation cuts by the Contractor, subject to change.C35 GS = El. 16.6ft. Cuts to El. 15.5 and 13.5ft. So collect risk from El. 9-7ft (7.6-9.6ft bgs). Round 7.5-9.5ft.
yE33Supplemental MCP Risk Data - PAC CyanideV-495D-MCP-E33-A (8-10)108-101-PAC CyanideProposed depth intervals based on anticipated generalized remedial excavation cuts by the Contractor, subject to change.E33 GS = 16.7ft. Cuts to 13.5,12.8,10.7,10. Collect sample from El. 9-7ft (7.7-9.7ft bgs). Round 8-10ft bgs.
yE35Supplemental MCP Risk Data - PAC CyanideV-495D-MCP-E35-A (7.5-9.5)9.57.5-9.51-PAC CyanideProposed depth intervals based on anticipated generalized remedial excavation cuts by the Contractor, subject to change.E35 GS = 16.2ft. Cuts to 10.5,10. Collect sample from El. 9-7ft (7.2-9.2ft bgs). Round 7.5-9.5ft.
yG27Supplemental MCP Risk Data - PAC CyanideV-495D-MCP-G27-A (4-6)
V-495D-MCP-G27-A (7.5-9.5)9.54-6
7.5-9.52-PAC CyanideProposed depth intervals based on anticipated generalized remedial excavation cuts by the Contractor, subject to change.G27 GS = 18.4ft. Cuts to 15.5, 12. Collect sample from El. 14.5-12.5 & 11-9ft (3.9-5.9ft bgs, 7.4-9.4ft bgs). Round 4-6ft & 7.5-9.5ft.
yG29Supplemental MCP Risk Data - PAC CyanideV-495D-MCP-G29-A (3.5-5.5)5.53.5-5.51-PAC CyanideProposed depth intervals based on anticipated generalized remedial excavation cuts by the Contractor, subject to change.G29 GS = 17.8ft. Cuts to 15.5ft. Collect sample from El. 14.5-12.5ft (3.3-5.3ft bgs). Round 3.5-5.5ft bgs.
yG31Supplemental MCP Risk Data - PAC CyanideV-495D-MCP-G31-B (3-5)
V-495D-MCP-G31-B (9-11)113-5
9-112-PAC CyanideProposed depth intervals based on anticipated generalized remedial excavation cuts by the Contractor, subject to change.G31 GS = 17.4ft. Cuts to 15.5, 9.8ft. Collect sample from El. 14.5-12.5 & 8.5-6.5ft (2.9-4.9ft bgs & 8.9-10.9ft bgs). Round 3-5ft & 9-11ft.
yG35Supplemental MCP Risk Data - PAC CyanideV-495D-MCP-G35-B (7-9)
V-495D-MCP-G35-B (10-12)127-9
10-122-PAC CyanideProposed depth intervals based on anticipated generalized remedial excavation cuts by the Contractor, subject to change.G35 GS = 16.3. Cuts to El. 10.5,7.5ft. Collect sample from El. 9.5-7.5ft & 6.5-4.5ft (6.8-8.8ft bgs, 9.8-11.8ft bgs). Round 7-9ft & 10-12ft.
yG36/G37Supplemental MCP Risk Data - PAC CyanideV-495D-MCP-G36/37-A (7.5-9.5)
V-495D-MCP-G36/37-A (10-12)127.5-9.5
10-122-PAC CyanideProposed depth intervals based on anticipated generalized remedial excavation cuts by the Contractor, subject to change.G36/37 GS = El. 16.3ft. Cuts to El. 16.1,10,7.5 ft. Collect sample from El. 9-7ft & 6.5-4.5ft (7.3-9.3ft bgs & 9.8-11.8ftbgs). Round to 7.5-9.5ft bgs & 10-12ft bgs.
yI27Supplemental MCP Risk Data - PAC CyanideV-495D-MCP-I27-C (7.5-9.5)
V-495D-MCP-I27-C (20-22)227.5-9.5
20-222-PAC CyanideProposed depth intervals based on anticipated generalized remedial excavation cuts by the Contractor, subject to change.I27 GS = El. 22.1ft. Cuts to El. 15.5, 3, &-1.5ft. Collect sample from El. 14.5-12.5 & 2-4ft) (7.6-9.6ft bgs &20.1-22.1ft bgs). Round to 7.5-9.5ft bgs & 20-22ft bgs.
yI29Supplemental MCP Risk Data - PAC CyanideV-495D-MCP-I29-C (10.5-12.5)12.510.5-12.51-PAC CyanideProposed depth intervals based on anticipated generalized remedial excavation cuts by the Contractor, subject to change.I29 GS = El. 18.2ft. Cuts to El. 9 & -1.5ft. Collect sample from El. 8-6ft (10.2-12.2ft bgs). Round to 10.5-12.5ft bgs.
yI31Supplemental MCP Risk Data - PAC CyanideV-495D-MCP-I31-B (3.5-5.5)
V-495D-MCP-I31-B (20-22)223.5-5.5
20-222-PAC CyanideProposed depth intervals based on anticipated generalized remedial excavation cuts by the Contractor, subject to change.I31 GS = El. 17.8ft. Cuts to El. 15.5, -1.5ft.Collect sample from El. 14.5-12.5ft & -2.0-(-4.0) (3.3-5.3ft bgs & 19.8-21.8ft bgs). Round 3.5-5.5ft & 20-22ft bgs).
yA32Total Barium hot spot delineation (main area)V-495D-BA-A32 (0-5)50-51-Total BariumHorizontal delineation sample
yB32Total Barium hot spot delineation (main area)V-495D-BA-B32 (0-5)50-51-Total BariumHorizontal delineation sample
yF32Total Barium hot spot delineation (main area)V-495D-BA-F32 (0-5)50-51-Total BariumHorizontal delineation sample
yG33Total Barium hot spot delineation (main area)V-495D-BA-G33-B (0-5)50-51-Total BariumHorizontal delineation sample
y5N-14 (former Roux Sample Location)Total Barium hot spot delineation (main area)V-(5N-14) (6-7)76-71-Total BariumVertical delineation sampleOriginal 5N-14 deepest M3CL exceedance was from 4-5ft bgs at time of collection (El. 11.6-10.6). No sample collected deeper, so need to vertically delineate. Need to collect sample from El. 10.6-9.6ft. Current GS at this area is ~16.2ft. Collect sample from 5.6-6.6ft below current grade. Rounded down to nearest 0.5ft interval = 6-7 ft below currnt grade.
y5N-12 (former Roux Sample Location)Total Barium hot spot delineation (main area)V-(5N-12) (6-7)76-71-Total BariumVertical delineation sampleOriginal 5N-12 deepest M3CL exceedance was from 4-5ft bgs at time of collection (El. 11.5-10.5). No sample collected deeper, so need to vertically delineate. Need to collect sample from El. 10.5-9.5ft. Current GS at this area is ~16.2ft. Collect sample from 5.7-6.7ft below current grade. rounded down to nearest 0.5ft interval = 6 to 7ft below current grade.
y6-12 (former Roux Sample Location)Total Barium hot spot delineation (main area)V-(6-12) (5-6)65-61-Total BariumVertical delineation sampleOriginal 6-12 deepest M3CL exceedance was from 4-5ft bgs at time of collection (El. 12.7-11.7). No sample collected deeper, so need to vertically delineate. Need to collect sample from El. 11.7-10.7ft. Current GS at this area is ~16.5ft. Collect sample from 4.8-5.8ft below current grade. Rounded down to nearest 0.5ft interval = 5 to 6ft below current grade.
yRX-8 (former Roux Sample Location)Total Barium hot spot delineation (main area)V-(RX-8) (2-4)42-41-Total BariumVertical delineation sampleOriginal RX-8 deepest M3CL exceedance was from 0-2ft bgs at time of collection (El. 16.6-14.6ft). RX-8 does have a sample at 4-5ft bgs that is below M3CL. Need to collect sample from El. 14.6-12.6ft. Current GS at this area is 16.6ft. Collect sample from 2-4ft below current grade.
y5ft NW of SOUTH-3Total Barium hot spot delineation (SOUTH-3)V-(SOUTH-3)-5NW (3-4)43-41-Total Barium--Original SOUTH-3

At time of collection 1-2ft (7,800mg/kg - RCS-1 exceed) & 2-3ft bgs (15,000mg/kg - M3CL exceed).

Elevations = 15.4-14.4ft and 14.4-13.4ft Current ground surface in this area = El. 17.6ft Current feet below ground surface for samples = 2-3ft and 3-4ft

y5ft NE of SOUTH-3Total Barium hot spot delineation (SOUTH-3)V-(SOUTH-3)-5NE (3-4)43-41-Total Barium--If shallower sample is hot spot, its EPC won't exceed M3CLs so it can stay, don't need to delineate/evaluate it further
y5ft SE of SOUTH-3Total Barium hot spot delineation (SOUTH-3)V-(SOUTH-3)-5SE (3-4)43-41-Total Barium--We're sampling 3-4 to match their 2-3 interval
y5ft SW of SOUTH-3Total Barium hot spot delineation (SOUTH-3)V-(SOUTH-3)-5SW (3-4)43-41-Total Barium--
y10ft NW of SOUTH-3Total Barium hot spot delineation (SOUTH-3)V-(SOUTH-3)-10NW (3-4)43-4-1Total BariumHOLD - Pending results
y10ft NE of SOUTH-3Total Barium hot spot delineation (SOUTH-3)V-(SOUTH-3)-10NE (3-4)43-4-1Total BariumHOLD - Pending results
y10ft SE of SOUTH-3Total Barium hot spot delineation (SOUTH-3)V-(SOUTH-3)-10SE (3-4)43-4-1Total BariumHOLD - Pending results
y10ft SW of SOUTH-3Total Barium hot spot delineation (SOUTH-3)V-(SOUTH-3)-10SW (3-4)43-4-1Total BariumHOLD - Pending results
y5ft NW of SOUTH-4Total Barium hot spot delineation (SOUTH-4)V-(SOUTH-4)-5NW (1-3)31-31-Total Barium--Original SOUTH-4

At time of collection 0-2ft exceeded M3CL Elevation = 16.6-14.6 Current ground surface in this area ~=17.6 Current feet below ground surface for samples = 1-3ft bgs

y5ft NE of SOUTH-4Total Barium hot spot delineation (SOUTH-4)V-(SOUTH-4)-5NE (1-3)31-31-Total Barium--
y5ft SE of SOUTH-4Total Barium hot spot delineation (SOUTH-4)V-(SOUTH-4)-5SE (1-3)31-31-Total Barium--
y5ft SW of SOUTH-4Total Barium hot spot delineation (SOUTH-4)V-(SOUTH-4)-5SW (1-3)31-31-Total Barium--
y10ft NW of SOUTH-4Total Barium hot spot delineation (SOUTH-4)V-(SOUTH-4)-10NW (1-3)31-3-1Total BariumHOLD - Pending results
y10ft NE of SOUTH-4Total Barium hot spot delineation (SOUTH-4)V-(SOUTH-4)-10NE (1-3)31-3-1Total BariumHOLD - Pending results
y10ft SE of SOUTH-4Total Barium hot spot delineation (SOUTH-4)V-(SOUTH-4)-10SE (1-3)31-3-1Total BariumHOLD - Pending results
y10ft SW of SOUTH-4Total Barium hot spot delineation (SOUTH-4)V-(SOUTH-4)-10SW (1-3)31-3-1Total BariumHOLD - Pending results
y5ft NW of K23K23 - Total lead potential hot spotV-495D-WC-K23-5NW (1-6)61-61-Total Lead--
y5ft NE of K23K23 - Total lead potential hot spotV-495D-WC-K23-5NE (1-6)61-61-Total Lead--
y5ft SE of K23K23 - Total lead potential hot spotV-495D-WC-K23-5SE (1-6)61-61-Total Lead--
y5ft SW of K23K23 - Total lead potential hot spotV-495D-WC-K23-5SW (1-6)61-61-Total Lead--
y10ft NW of K23K23 - Total lead potential hot spotV-495D-WC-K23-10NW (1-6)61-6-1Total LeadHOLD - Pending results
y10ft NE of K23K23 - Total lead potential hot spotV-495D-WC-K23-10NE (1-6)61-6-1Total LeadHOLD - Pending results
y10ft SE of K23K23 - Total lead potential hot spotV-495D-WC-K23-10SE (1-6)61-6-1Total LeadHOLD - Pending results
y10ft SW of K23K23 - Total lead potential hot spotV-495D-WC-K23-10SW (1-6)61-6-1Total LeadHOLD - Pending results
y5ft NW of C23C23 - Total chromium potential hot spotV-495D-WC-C23-5NW (1-6)61-61-Total Chromium--
y5ft NE of C23C23 - Total chromium potential hot spotV-495D-WC-C23-5NE (1-6)61-61-Total Chromium--
y5ft SE of C23C23 - Total chromium potential hot spotV-495D-WC-C23-5SE (1-6)61-61-Total Chromium--
y5ft SW of C23C23 - Total chromium potential hot spotV-495D-WC-C23-5SW (1-6)61-61-Total Chromium--
y10ft NW of C23C23 - Total chromium potential hot spotV-495D-WC-C23-10NW (1-6)61-6-1Total ChromiumHOLD - Pending results
y10ft NE of C23C23 - Total chromium potential hot spotV-495D-WC-C23-10NE (1-6)61-6-1Total ChromiumHOLD - Pending results
y10ft SE of C23C23 - Total chromium potential hot spotV-495D-WC-C23-10SE (1-6)61-6-1Total ChromiumHOLD - Pending results
y10ft SW of C23C23 - Total chromium potential hot spotV-495D-WC-C23-10SW (1-6)61-6-1Total ChromiumHOLD - Pending results
yE19Waste Characterization (for additional depth)V-495D-WC-E19-A (11-16)1611-16-1Disposal CharacterizationHOLD - Pending results of I21 NAPL Extent InvestigationSupplemental Disposal Characterization & TCLP Delineation
yE21Waste Characterization (for additional depth)V-495D-WC-E21-B (11-16)
V-495D-WC-E21-B (12-16)1611-16 (no PCBs)
12-16 (PCB Only)-211-16' interval - Disposal Characterization (no PCBs)
12-16' interval - PCB analysis onlyHOLD - Pending results of I21 NAPL Extent Investigation
yE23Waste Characterization (for additional depth)V-495D-WC-E23-B (12-17)1712-17-1Disposal CharacterizationHOLD - Pending results of I21 NAPL Extent Investigation
yG19Waste Characterization (for additional depth)V-495D-WC-G19-B (12-17)1712-17-1Disposal CharacterizationHOLD - Pending results of I21 NAPL Extent Investigation
yG21Waste Characterization (for additional depth)V-495D-WC-G21-B (11-16)
V-495D-WC-G21-B (12-16)1611-16 (no PCBs)
12-16 (PCB only)-211-16' interval - Disposal Characterization (no PCBs)
12-16' interval - PCB analysis onlyHOLD - Pending results of I21 NAPL Extent Investigation
yI19Waste Characterization (for additional depth)V-495D-WC-I19-A (11-16)
V-495D-WC-I19-A (12-16)1611-16 (no PCBs)
12-16 (PCB only)-211-16' interval - Disposal Characterization (no PCBs)
12-16' interval - PCB analysis onlyHOLD - Pending results of I21 NAPL Extent Investigation
yK21Waste Characterization (for additional depth)V-95D-WC-K21-B (12-17)1711-17-1Disposal CharacterizationHOLD - Pending results of I21 NAPL Extent Investigation
yI25Waste Characterization (for additional depth)V-495D-WC-I25-B (16-21)2116-211-Disposal Characterization--
yI27Waste Characterization (for additional depth)V-495D-WC-I27-C (23-28)2823-281-Disposal Characterization + Total Cyanide--
yM29Waste Characterization (for additional depth)V-495D-WC-M29-C (20-25)2520-251-Disposal Characterization--
yM31Waste Characterization (for additional depth)V-495D-WC-M31-C (20-25)2320-251-Disposal Characterization + Total Cyanide--
yA27Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-A27-A (1-6)61-61-Total Cyanide--
yA29Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-A29-A (1-6)61-61-Total Cyanide--
yA31Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-A31-A (1-6)61-61-Total Cyanide--
yA33Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-A33-B (1-6)61-61-Total Cyanide--
yA35Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-A35-A (1-6)61-61-Total Cyanide--
yA36/37Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-A36/37-A (1-6)61-61-Total Cyanide--
yC27Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-C27-A (1-6)
V-495D-WC-C27-A (6-11)111 - 6
6 - 112-Total Cyanide--
yC29Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-C29-B (1-6)

V-495D-WC-C29-B (6-11)

V-495D-WC-C29-B (11-16)

V-495D-WC-C29-B (16-20) 20 1 - 6

6 - 11 11 - 16

16 - 204-Total Cyanide--
yC31Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-C31-B (1-6)61-61-Total Cyanide--
yC33Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-C33-A (1-6)61-61-Total Cyanide--
yC35Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-C35-B (1-6)61-61-Total Cyanide--
yC36/37Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-C36/37-A (1-6)61-61-Total Cyanide--
yE27Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-E27-B (1-6)61-61-Total Cyanide--
yE29Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-E29-A (1-6)
V-495D-WC-E29-A (6-11)111 - 6
6 - 112-Total Cyanide--
yE31Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-E31-A (1-6)61-61-Total Cyanide--
yE33Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-E33-A (1-6)
V-495D-WC-E33-A (6-11)111 - 6
6 - 112-Total Cyanide--
yE35Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-E35-A (1-6)
V-495D-WC-E35-A (6-11)111 - 6
6 - 112-Total Cyanide--
yE36/37Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-E36/37-A (1-6)
V-495D-WC-E33/37-A (6-11)111 - 6
6 - 112-Total Cyanide--
yG27Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-G27-A (1-6)
V-495D-WC-G27-A (6-11)111 - 6
6 - 112-Total Cyanide--
yG29Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-G29-A (1-6)61-61-Total Cyanide--
yG31Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-G31-B (1-6)
V-495D-WC-G31-B (6-11)111 - 6
6 - 112-Total Cyanide--
yG33Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-G33-B (1-6)
V-495D-WC-G33-B (6-11)111 - 6
6 - 112-Total Cyanide--
yG35Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-G35-B (1-6)
V-495D-WC-G35-B (6-11)111 - 6
6 - 112-Total Cyanide--
yG36/G37Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-G36/37-A (1-6)
V-495D-WC-G36/37-A (6-11)111 - 6
6 - 112-Total Cyanide--
yI27Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-I27-C (1-6)

V-495D-WC-I27-C (6-11)

V-495D-WC-I27-C (11-16)

V-495D-WC-I27-C (16-20)

V-495D-WC-I27-C (20-23) 23 1 - 6

6 - 11 11 - 16 16 - 20

20 - 235-Total Cyanide--
yI29Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-I29-C (1-6)

V-495D-WC-I29-C (6-11)

V-495D-WC-I29-C (11-16)

V-495D-WC-I29-C (16-20) 20 1 - 6

6 - 11 11 - 16

16 - 204-Total Cyanide--
yI31Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-I31-B (1-6)

V-495D-WC-I31-B (6-11)

V-495D-WC-I31-B (11-16)

V-495D-WC-I31-B (16-20) 20 1 - 6

6 - 11 11 - 16

16 - 204-Total Cyanide--
yI33Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-I33-C (1-6)

V-495D-WC-I33-C (6-11)

V-495D-WC-I33-C (11-16)

V-495D-WC-I33-C (16-20) 20 1 - 6

6 - 11 11 - 16

16 - 204-Total Cyanide--
yI35Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-I35-A (1-6)
V-495D-WC-I35-A (6-11)111 - 6
6 - 112-Total Cyanide--
yI36/37Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-I36/37-A (1-6)61 - 61-Total Cyanide--
yK29Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-K29-B (1-6)

V-495D-WC-K29-B (6-11)

V-495D-WC-K29-B (11-16)

V-495D-WC-K29-B (16-20) 20 1 - 6

6 - 11 11 - 16

16 - 204-Total Cyanide--
yK31Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-K31-B (1-6)

V-495D-WC-K31-B (6-11)

V-495D-WC-K31-B (11-16)

V-495D-WC-K31-B (16-20) 20 1 - 6

6 - 11 11 - 16

16 - 204-Total Cyanide--
yK33Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-K33-B (1-6)

V-495D-WC-K33-B (6-11)

V-495D-WC-K33-B (11-16)

V-495D-WC-K33-B (16-20) 20 1 - 6

6 - 11 11 - 16

16 - 204-Total Cyanide--
yK35Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-K35-B (1-6)61 - 61-Total Cyanide--
yK36/37Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-K36/37-B (1-6)61 - 61-Total Cyanide--
yM31Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-M31-C (1-6)

V-495D-WC-M31-C (6-11)

V-495D-WC-M31-C (11-16)

V-495D-WC-M31-C (16-20) 20 1 - 6

6 - 11 11 - 16

16 - 204-Total Cyanide--
yM33Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-M33-A (1-5)

V-495D-WC-M33-A (5-10)

V-495D-WC-M33-A (10-15)

V-495D-WC-M33-A (15-20) 20 1 - 5

5 - 10 10 - 15

15 - 204-Total Cyanide--
yM35Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-M35-C (1-6)
V-495D-WC-M35-C (6-11)111 - 6
6 - 112-Total Cyanide--
yM36/37Supplemental Disp Characterization - Total Cyanide (475 Dot Ave)V-495D-WC-M36/37-A (1-6)

V-495D-WC-M36/37-A (6-11)

V-495D-WC-M36/37-A (11-16) 16 1 - 6

6 - 11

11 - 162-Total Cyanide--Roux sample interval ElevationCurrent GS ElevationCurrent Depth BgsRound
yB35TCLP Barium DelineationV-495D-TCLP-B35 (0-5)50-51-TCLP BariumSample depth intended to match previous Roux soil sample intervals accounting for changes in surface elevation.
Exclude surface asphalt pavement from the soil sample collected for analysis.16.5-11.516.50-50-5
yD34TCLP Barium DelineationV-495D-TCLP-D34 (0-5)50-51-TCLP BariumSample depth intended to match previous Roux soil sample intervals accounting for changes in surface elevation.
Exclude surface asphalt pavement from the soil sample collected for analysis.16.5-11.516.50-50-5
yE/F/35/36TCLP Barium DelineationV-495D-TCLP-E/F35/36 (1-6)61-61-TCLP BariumSample depth intended to match previous Roux soil sample intervals accounting for changes in surface elevation.
Sample should be a 5-foot composite starting below the cap.15.5-10.516.20.7-5.71-6
yF/36/37TCLP Barium DelineationV-495D-TCLP-F36/37 (1-6)61-61-TCLP BariumSample depth intended to match previous Roux soil sample intervals accounting for changes in surface elevation.
Sample should be a 5-foot composite starting below the cap.15.5-10.516.20.7-5.71-6
yF/G/35/36TCLP Barium DelineationV-495D-TCLP-F/G35/36 (1-6)61-61-TCLP BariumSample depth intended to match previous Roux soil sample intervals accounting for changes in surface elevation.
Sample should be a 5-foot composite starting below the cap.15.5-10.516.30.8-5.81-6
yF33TCLP Barium DelineationV-495D-TCLP-F33 (0.5-5.5)5.50.5-5.51-TCLP BariumSample depth intended to match previous Roux soil sample intervals accounting for changes in surface elevation.
Sample should be a 5-foot composite starting below the cap.16.5-11.516.90.4-5.40.5-5.5
yG/H/35/36TCLP Barium DelineationV-495D-TCLP-G/H35/36 (1-6)61-61-TCLP BariumSample depth intended to match previous Roux soil sample intervals accounting for changes in surface elevation.
Sample should be a 5-foot composite starting below the cap.15.5-10.516.30.8-5.81-6
yH34TCLP Barium DelineationV-495D-TCLP-H34 (1.5-6.5)6.51.5-6.51-TCLP BariumSample depth intended to match previous Roux soil sample intervals accounting for changes in surface elevation.
Sample should be a 5-foot composite starting below the cap.15.5-10.5171.5-6.51.5-6.5
yG28TCLP Lead DelineationV-495D-TCLP-G28 (1-6)61-6-1TCLP LeadHOLD - Pending resultsmap says total VOCs and SPLP VOCs but these are not included here
yH21TCLP Lead DelineationV-495D-TCLP-H21-A (1-6)61-61-TCLP Lead--
yH27TCLP Lead DelineationV-495D-TCLP-H27-A (1-6)61-61-TCLP Lead--
yH28TCLP Lead DelineationV-495D-TCLP-H28 (1-6)61-61-TCLP Lead--
yJ32TCLP Lead DelineationV-495D-TCLP-J32 (1-6)61-6-1TCLP LeadHOLD - Pending results
yK31TCLP Lead DelineationV-495D-TCLP-K31-B (1-6)61-61-TCLP Lead--
yK32TCLP Lead DelineationV-495D-TCLP-K32 (1-6)61-61-TCLP Lead--
yL32TCLP Lead DelineationV-495D-TCLP-L32 (1-6)61-61-TCLP Lead--
yL33TCLP Lead DelineationV-495D-TCLP-L33 (1-6)61-6-1TCLP LeadHOLD - Pending resultsmap says total VOCs and SPLP VOCs but these are not included here
yM32TCLP Lead DelineationV-495D-TCLP-M32 (1-6)61-61-TCLP Lead--
yN31TCLP Lead DelineationV-495D-TCLP-N31-B (1-6)61-61-TCLP Lead--
yN32TCLP Lead DelineationV-495D-TCLP-N32 (1-6)61-6-1TCLP LeadHOLD - Pending results
Total Number of Samples18864
borings155
Notes:borings/day10total days15.5
• Full disposal characterization includes analysis for TPH, VOCs, SVOCs, MCP 14 Metals, PCBs (where indicated), general chemistry, and pesticides/herbicides (approximately 10% of samples).
• General chemistry includes corrosivity, conductivity, reactivity, ignitability, and total solid analysis.
• Total petroleum hydrocarbons (TPH) by USEPA Method 8015.
• VOCs by USEPA Method 8260.
• SVOCs by USEPA Method 8270.
• Massachusetts Contingency Plan (MCP) 14 total metals by USEPA Methods 6010 and 7471.
• Polychlorinated biphenyls (PCBs) by USEPA Method 8082 with soxhlet extraction.
• Extractable petroleum hydrocarbons (EPH) by MassDEP Methods.
• Volatile petroleum hydrocarbons (VPH) by MassDEP Methods.
• Physiologically available cyanide (PAC) by USEPA Method 9014.
• Pesticides by USEPA Method 8081.
• Herbicides by USEPA Method 8151.
• Corrosivity (pH) by USEPA Method 9045.
• Conductivity by USEPA Method 9050.
• Reactivity (cyanide and sulfide) by USEPA Methods 125, 7.3.
• Ignitability by USEPA Method 1030.
• Total solids by USEPA Methods 121, 2540G.
• Toxicity characteristic leaching produecure (TCLP) barium, lead, or VOCs by USEPA Method 1311.
• Synthetic precipitation leaching produecure (SPLP) cis-1,2-dichloroethene, (cis-1,2-DCE), vinyl chloride, tetrachloroethylene (PCE), and trichloroethylene (TCE) by USEPA Method 1312.
• Synthetic precipitation leaching produecure (SPLP) EPH by MassDEP Methods.

&"-,Bold"&14Table 1 Summary of Soil Boring && Soil Sampling Investigation Scope 495 Development Area Former 511 and 475 Dorchester Avenue South Boston, Massachusetts VERTEX Project No. 80979

&G &"-,Bold"&10Page &P of &N image1.png

File details come from the government source that posted it. Updated .