667-081 OUTPATIENT MH IMPR_BSMNT AND 1st FLOOR AS-BUILTS A101.pdf
PDF 204 KB Posted
- Solicitation number
- 667-24-120
About this file
This document appears to be an as-built drawing set for the outpatient mental health improvements to the Overton Brooks Veterans Administration Medical Center in Shreveport, Louisiana. The drawing set includes a basement floor plan with detailed room labels, dimensions, and notes describing the renovation work. Key details include:
The renovation involves improvements to the basement and 1st floor of the outpatient mental health facility. Scope includes new wall partitions, flooring, ceiling, and other interior finishes. Special features noted are a dry erase presentation wall, glass bulletin board, and canopy column. The drawings incorporate several revisions based on RFIs and addenda. This appears to be an as-built set documenting the completed construction.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25624R0055 0001.docx | DOCX document | |
| SOW - Renovate for VA Kids Care 6-10-24.docx | DOCX document | |
| 667-24-120 VA Kids Care RFI Register 06132024.docx | DOCX document | |
| SOW Attachment 2 - VA Kids Care Space Design Guide.pdf | ||
| 36C25624R0055 SOW 667-24-120 022224.docx | DOCX document | |
| SOW Attachment 3 - Final Response to VCAP PSRDM Deviation Request.pdf | ||
| 36C25624R0055 EXHIBIT A.docx | DOCX document | |
| 36C25624R0055 EXHIBIT B.docx | DOCX document | |
| 36C25624R0055 EXHIBIT E.docx | DOCX document | |
| 36C25624R0055 EXHIBIT F.docx | DOCX document | |
| 36C25624R0055 EXHIBIT C.docx | DOCX document | |
| SOW Attachment 1 - Program for Design.pdf | ||
| 36C25624R0055 RFP.docx | DOCX document | |
| 36C25624R0055 WD LA20240031 Mod 01052024.pdf | ||
| 36C25624R0055 EXHIBIT D.docx | DOCX document |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
UP
F1 A204
Social Worker
BS-46
Nurse
BS-24M
HI
CM
St o.
BS
-2
Corridor BS-90 Social
Worker
BS-14
Read BS-58 Check-in
BS-54
Read
BS-56
Coord.
BS-38
ADD
Therapist
BS-51
Men
BS-62
Social Worker
BS-16
Stair #10
BS-34
Peer
BS-18
Social Worker
BS-26
Res.
M.D.
BS-28
RN
BS-30
Women
BS-64
Check-in
BS-66
Nurse
BS-17
Nurse
BS-19
Intake
BS-63
Unisex
BS-42
Observation
BS-32
H G F E D C B
J A
Elev.
BS-08
Stair #9
BS-06
MD
BS-60 Nurse
BS-52
Exam/ Med
BS-21
Director
BS-20
Mech.
BS-23
C1 A204
B
Check-In
BS-67
Sto.
BS-65
Exam/Med
BS-35
Group
BS-45
St af f
BS
-2 7A
Corridor
BS-93
Ja n
BS
-0
C
C
ADD
Therapist
BS-53
B re ak
BS
-2 7 036
ADD
Therapist
BS-44
Rec.
Therapist
BS-48
LPN
BS-50
Corridor
BS-96
C
OH Projector by owner
W ai tin g
BS
-1
W ai tin g
BS
-1
Elect.
BS-03
A301 F6
A303 F7
A701 F7
A701 D5
B8 A607
F4 A302
003 004 005 006 007 008 010 011
025 024 022 021 020 019
018 017
032 035
041 039
A A A
A A A B
E
E
KL
Elevator Lobby
BS-91
Corridor
BS-92
Corridor
BS-95
Corridor
BS-94
A608 D3
A608 B3
A608 F1
A608 F5
S. Utility
BS-40
C. Utility
BS-36
A701 F2
A702 D7
A703 F7
B4 A703
D
D
A608 D1
F1 A601 tv tv
Fu tu re
Fu tu re
C hi lle r
Xf or m er
049 050 051 052
F8 A604
IT
BS-04
cl ea r
6'
0"
1'
6" cl ea r
7'
8"
6' - 0" 15' - 4" 8" 20' - 0" 8" 7' - 4" 6' - 6" 7' - 6" 5' - 4" clear
6' - 0"
9'
6"
6'
0" clear
6' - 0" 11' - 2" 10' - 8"
1' - 4"
21' - 4" 21' - 4" 21' - 4" 21' - 4" 21' - 4" 21' - 4" 1' - 4"
10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 2' - 8"
8' - 0" 10' - 8" 10' - 8" 10' - 8" 10' - 8" 10' - 8"
10' - 8" 10' - 8" 14' - 3" 7' - 1" 3' - 7" 10' - 8" 7' - 1" 3' - 7" 10' - 8"
7' - 1" 5' - 4" 16' - 0" 21' - 4"
1'
4"
1'
4"
10' - 0"
1'
4"
6'
0"
1'
0"
/8
7'
5/ 8"
7'
8"
2' - 2"3' - 6" vif
9' - 4 5/8"
2 2
10' - 8" 10' - 8"
F5 A601
Clo.
BS-45B
1' - 10"
EWC
Existing retaining wall
E E E
E EE
SPD
B-E-28
Elect.
BS-04A
D5 A607
J.3
F
Face of brick existing building
Face of brick bsm't wall
Centerline of col
Face of brick
2'
5"
4' - 7"
A704 C3
Face of existing brick
Working point, intersection of grid lines "K" & "1"
13 13
Vest.
BS-01
130' - 8"37' - 0"
1' - 4"
1' - 4" verify in field 21' - 11"
1' - 0" verify in field 14' - 1"
FEC14
14 EJC #7
EJ #1
5'
0"
EJ
062ladder to sub-basement re: F2/A301
FEC
FEC
Pipe Chase
BS-93
/8
8'
/8
/8
1'
6"
/8 fa ce o f co nc fa ce o f e xi st b ld g
8' - 4"
28' - 8" 8' - 4" vif
5' - 4 7/16"6' - 0 5/16"6' - 11 11/16"
1'
1/
8"
6 1/4" refer to F4/C104 for in-ground canopy lighting line of canopy above
A610 F1 bench
EJ #1
EJ #9
EJ #1
Typical x 4
2' - 8"
RFI #51
8" w all -
RFI #50
4 1/2"
2 1/2"
17' - 0 3/8"16'-8 3/8"
W all in cre as ed to
RFI #
W al l r em ov ed
R em ov e si nk
R em ov e si nk
R em ov e si nk
R em ov e si nk
R em ov e si nk
Remove door
N or th
1/8" = 1'-0" F7 Basement Plan
6" thr ee in ch es on e f oo t thr ee qu ar ter s i nc h = on e f oo t on e a nd on e h alf in ch on e f oo t
6" on e h alf in ch on e f oo t on e q ua rte r in ch on e f oo t on e e igh th inc h = on e f o o t
Project Number
Building Number
Drawing Number
Project Title
Location
Date Checked Drawn
2 3 4 5 6 7
Drawing Title
Approved: Project Director
ARCHITECT/ENGINEERS:
Tompkins Architects, LLC
612 N.W. Kay Drive Lee's Summit, Missouri 64063 Phone: (816) 525-9833 Fax: (816) 524-9005 Email: jet@tom-arch.com 1308 South Main Street
Little Rock, Arkansas 72202 Phone: (501) 378-0059 www.stuckarch.com
CONSULTANTS:
Dwg. of
F
E
D
C
B
A
Jacobs Engineering Office of Facility
Management
10816 EXECUTIVE CENTER DRIVE, SUITE 300
LITTLE ROCK, ARKANSAS 7211-4383
PHONE (501 223-0515 FAX (501) 223-2470
JACOBS PROJECT NO: F3W81800
REVISIONS DATE
AS-BUILT SET 06/25/2012
AS-BUILT DRAWINGS
This document has been prepared based on As-
Built information provided by others. Those relying on this document are advised to obtain independent verification of its accuracy before using it for any purpose.10 /2
2/
:0 4:
P
M
Shreveport, Louisiana
01/20/2010
Outpatient Mental Health Improvements Overton BrooksBasement Plan
667-081
100% SubmittalA101
Bldg. 1, South Wing
11 123
Veterans Administration Medical Center
Checker Author
Floor Plan General Notes A All construction shall be in accordance with the requirements of the applicable codes, engineering shall conform with all applucable municipal, state and federal regulationd having jurisdiction including accessibility standards and requirements of "Americans with Disabilities Act."
B Each trade is advised that information pertinent to its work may occur in variuos sections of the contract documents. Refer to every sheet of drawings for notes and symbols. Notes shall be reviewed and applied to related building components regardless of their locations in the drawings and specifications.
C Unless noted otherwise, any note, detail, or feature indicated for one condition shall be applicable for all alike and similar conditions
D The contractor shall furnish and install all stiffeners, bracing, backing plated and supporting brackets required for the proper installation of all building components as recommended by the manufacturer and required by code.
E All dissimilar metals shall be effectively isolated from each other to avoid molecular breakdown.
F All exterior joints around window and door frames, between walls and founds, between walls and roof, between wall panels, at penetration of utilities through the envelope shall be sealed or weather-stripped to prevent air and moisture leakeage and infiltration.
G Finish floor elevations are to the top of concrete, unless noted otherwise.
H Provide firestopping at all column penetrations - reference specifications.
J Where partitions are removed, patch floor with floor stone as required.
Floor Plan Key Notes 1 Extend partition to centerline of window mullion 2 8" metal stud partition 3 2 hour partition 4 2 hour floor expansion joint cover 5 Not used 6 Not used 7 Dry erase presentation wallcovering full length and height of wall. Top of marker tray mounted at
3'-0". Seams shall be kept to a minimum, and a drawing showing proposed locations of the seams shall be submitted to the Architect for approval.
8 Smoke barrier- one hour rating 9 Provide blocking for TV bracket, coordinate size and height with owner 10 Provide 5/8" gyp bd on 1 7/8" furring channels at 16"oc over existing wall 11 Canopy column 12 Convex mirror, verify exact location with COTR 13 Handrail 14 Existing window to remain in place. Provide 5/8" gyp bd on metal framing infill at window recess.
Apply 5/8" gyp bd over existing plaster wall from inside corner to inside corner. Paint entire south wall. Rework ceiling and flooring to receive new work; replace base.
15 Provide approx 1 1/2" topping slab. Level with first floor slab at door 16 Verify exact location of partition with owner to surround duct work 17 Rework existing carpet at new construction. Reinstall base.
18 Not used 19 6" met. stud partition 20 Glass enclosed bulletin board; Refer to specifications for more information.
21 Smoke partition 22 Provide 20 ga. aluminum cover plate over floor EJ. Attach to one side of floor only & provide 2 hr.
fire barrier at e.j.
23 Work surface at 30" with 4" splash and supports as needed.
0' 4' 8' 16'
Scale: 1/8"=1'-0"
Dimension Notes A Interior partitions are dimensioned to the outside face or centerline of partition, unless noted otherwise. Do not scale drawings. Questions regarding dimensions shall be reported to the architect.
B Refer to large plans for possible continuation of dimensions.
FLOOR PLAN LEGEND
EWC electric water cooler FEC fire extinguisher cabinets TV television bracket by owner, blocking by general contractor EJ expansion joint EJC expansion joint cover
Addendum #6 - 07/27/09 11/24/091
Addendum #6: Concrete floor slab to be blocked out in Chase Room BS93 on first floor to accommodate chase. Reinforcing steel displaced by block out to be equally distributed on remaining sides of opening. Edges of opening to be notched and have a continuous galvanized L1.5x1.5x1/4 edge angle with 1/2" diameter headed studs at 24" o.c. to support removable 1.5" galvanized metal grating to cover entire opening area.
Opening shall not interfere with concrete beam along Grid 3.
Refer to B4/A610 for knock out panel
@ elev. doors.
RFI, #5 - 01/07/10 01/20/102
5"
3 "As-Built" Document Revisions
8" wall - R
FI #50 3
3 3
06/11/12
4 "As-Built" Document Revisions 10/08/12