654-18-807 -SNVAMC - Elec set.pdf

PDF 1 MB Posted

Attached to
Y1DA--NRM: 654-18-807; Water Monitoring and Treatment
Solicitation number
36C26121R0087
Issued by

About this file

This document package includes electrical plans and drawings for a water monitoring and treatment project at the Sierra Nevada VA Health Care System in Reno, Nevada. The drawings provide specifications for new and existing electrical systems in several buildings, including panel schedules, circuit information, notes and symbols. Relevant details include water monitoring equipment to be installed, provisions for transient voltage surge protection and data connections to the existing building management system. The related federal contract opportunity is solicitation number 36C26121R0087 for the water monitoring and treatment project, issued through the Department of Veterans Affairs Veterans Health Administration VISN 21. The response due date and award date are not provided.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

V.A.C.

ELECTRICAL SYMBOLS, NOTES AND

ABBREVIATIONS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

WATER MONITORING

AND TREATMENT

975 KIRMAN AVE.

RENO, NEVADA 89502

654-18-807

02/18/2021Revisions: Date: D.L.E.

SIERRA NEVADA VA HEALTH

CARE SYSTEM

A

E-001

AutoCAD SHX Text ELECTRICAL DEMOLITION NOTES REMOVE ALL OBSOLETE ELECTRICAL EQUIPMENT, FIXTURES, CONDUIT, WIRING, CONTROLS, HANGERS, PADS, AND SUPPORTS UNLESS OTHERWISE INDICATED TO REMAIN. DISCONNECT CIRCUIT AND WIRING FROM EQUIPMENT WHICH IS TO BE REMOVED BY OTHERS. WIRING MADE OBSOLETE BY THE NEW CONSTRUCTION SHALL BE REMOVED. CONDUIT MADE OBSOLETE BY THE NEW CONSTRUCTION SHALL BE REMOVED OR SECURELY SEALED AND CAPPED ABOVE CEILINGS, BELOW FLOORS, GRADE OR IN WALLS SO THAT IT IS COMPLETELY CONCEALED AT THE COMPLETION OF THE PROJECT. PIPING AND WIRING REMOVED FROM THE EXISTING ELECTRICAL SYSTEMS SHALL NOT BE USED IN THE INSTALLATION OF THE NEW SYSTEMS. DEMOLITION INCLUDES, BUT IS NOT LIMITED TO, REMOVAL AND LEGAL DISPOSAL OF EQUIPMENT AND SYSTEMS MADE OBSOLETE AND/OR REPLACED BY NEW WORK. DEMOLITION INCLUDES RELOCATION OR REINSTALLATION, DISCONNECTIONS AND RECONNECTIONS OF SERVICES, SUPPORTS, AND SUBSEQUENT FINAL SUPPORTS, TEMPORARY CAPPING, AND REROUTING OF TEMPORARY SERVICES TO PERMIT NEW OR RENOVATION WORK TO PROCEED. THE DEMOLITION WORK INDICATED ON THE DRAWING IS INTENDED TO ASSIST THE CONTRACTOR AND GIVE GENERAL INFORMATION. NOT ALL DEMOLITION OR TEMPORARY CONNECTIONS ARE SHOWN. PRIOR TO SUBMITTING BID, THE CONTRACTOR SHALL VISIT THE PROJECT SITE AND REVIEW ORIGINAL DRAWINGS IF AVAILABLE. CONTRACTOR IS RESPONSIBLE TO DETERMINE THE FULL EXTENT OF DEMOLITION, AND INCLUDE ALL REQUIRED DEMOLITION WORK IN HIS BID, WHETHER OR NOT SPECIFICALLY SHOWN ON DRAWINGS. NO ADDITIONAL COST WILL BE GRANTED FOR DEMOLITION. LEGALLY DISPOSE OF ALL ITEMS AND MATERIALS, EXCEPT ANY ITEMS SPECIFICALLY DESIGNATED BY THE OWNER TO BE SALVAGED. REMOVE AND REPLACE THE DESIGNATED SALVAGED EQUIPMENT IN A LOCATION DIRECTED BY THE OWNER AT NO ADDITIONAL EXPENSE. IN ALL AREAS WHERE PATCHING IS REQUIRED, THE CONTRACTOR SHALL PATCH THE SUBSURFACE WHERE THE NEW SURFACE IS TO BE FINISHED. A NEW FINISH WILL BE PROVIDED BY THE CONTRACTOR AND THE CONTRACTOR IS RESPONSIBLE TO PATCH THE SURROUNDING SURFACE TO MATCH EXISTING. CONTRACTOR IS RESPONSIBLE FOR ALL REQUIRED CUTTING AND PATCHING OF EXISTING SURFACES. CONTRACTOR SHALL REMOVE/REPLACE EXISTING CEILING TILES AND GRID AS REQUIRED TO ACCOMPLISH INDICATED ELECTRICAL WORK, UNLESS SPECIFICALLY INDICATED OTHERWISE. MAINTAIN CONTINUITY OF EXISTING CIRCUITS FOR EQUIPMENT AND DEVICES TO REMAIN. IF A DEVICE OR EQUIPMENT IS REMOVED AND IS PART OF AN EXISTING CIRCUIT TO REMAIN, THE CIRCUIT SHALL BE RESTORED TO IT'S ORIGINAL CONDITION.

AutoCAD SHX Text T

AutoCAD SHX Text

POWER

AutoCAD SHX Text

208/120V BRANCH CIRCUIT PANELBOARD

AutoCAD SHX Text

480/277V BRANCH CIRCUIT PANELBOARD

AutoCAD SHX Text

TRANSFORMER

AutoCAD SHX Text

MOTOR CONNECTION. NUMBER INDICATES HORSEPOWER

AutoCAD SHX Text

UNFUSED DISCONNECT SWITCH. SIZE AS NOTED

AutoCAD SHX Text

FUSED DISCONNECT SWITCH, SIZE AS NOTED

AutoCAD SHX Text

COMBINATION DISCONNECT SWITCH AND MAGNETIC MOTOR CONTROLLER, SIZE AS NOTED

AutoCAD SHX Text

FLUSH WALL JUNCTION BOX OR JUNCTION BOX ABOVE CEILING

AutoCAD SHX Text ABBREVIATIONS AMP./A. AMPERE AMPERE AC. ALTERNATING CURRENT ALTERNATING CURRENT A/C. AIR CONDITION AIR CONDITION A.F.F. ABOVE FINISHED FLOOR ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE ABOVE FINISHED GRADE A.I.C. AMPERES INTERRUPTING CAPACITY AMPERES INTERRUPTING CAPACITY AL ALUMINUM ALUMINUM ARCH. ARCHITECTURAL ARCHITECTURAL A.R.F. ABOVE RAISED FLOOR ABOVE RAISED FLOOR ASY. ASYMMETRICAL ASYMMETRICAL A.T.C. AUTOMATIC TEMPERATURE CONTROL AUTOMATIC TEMPERATURE CONTROL ATS AUTOMATIC TRANSFER SWITCH AUTOMATIC TRANSFER SWITCH AUX. AUXILIARY AUXILIARY B.F.S. BELOW FINISHED CEILING BELOW FINISHED CEILING BLDG. BUILDING BUILDING BKR. BREAKER BREAKER BSMT. BASEMENT BASEMENT .C. CENTIGRADE DEGREES CENTIGRADE DEGREES CLG. CEILING CEILING CKT. CIRCUIT CIRCUIT CB CIRCUIT BREAKER CIRCUIT BREAKER CW CLOCKWISE CLOCKWISE COL. COLUMN COLUMN CONC. CONCRETE CONCRETE CCTV CLOSED CIRCUIT TELEVISION CLOSED CIRCUIT TELEVISION C. CONDUIT CONDUIT CONDR. CONDUCTOR CONDUCTOR CU. FT. CUBIC FEET CUBIC FEET CONTR. CONTRACTOR CONTRACTOR CU. COPPER COPPER CONST. CONSTRUCTION CONSTRUCTION COAX. COAXIAL COAXIAL COORD. COORDINATE COORDINATE CONT. CONTINUATION CONTINUATION CMU CONCRETE MASONRY UNIT CONCRETE MASONRY UNIT C.T. CURRENT TRANSFORMER CURRENT TRANSFORMER DEMO DEMOLITION DEMOLITION DISC. DISCONNECT SWITCH DISCONNECT SWITCH DIV. DIVISION DIVISION DN. DOWN DOWN EA. EACH EACH E.F. EXHAUST FAN EXHAUST FAN ELEC. CL. ELECTRICAL CLOSET ELECTRICAL CLOSET ELEC. ELECTRICAL ELECTRICAL E.C. ELECTRICAL CONTRACTOR ELECTRICAL CONTRACTOR ELEV/EL. ELEVATION/ELEVATOR ELEVATION/ELEVATOR E.M.A. ELECTRICAL METALLIC TUBING ELECTRICAL METALLIC TUBING ENT. ENTRANCE ENTRANCE ENCL. ENCLOSURE ENCLOSURE EQ. EQUAL EQUAL EQUIP. EQUIPMENT EQUIPMENT E.W. EACH WAY EACH WAY EXT. EXTERNAL/EXTERIOR EXTERNAL/EXTERIOR F.A. FIRE ALARM FIRE ALARM FACP FIRE ALARM CONTROL PANEL FIRE ALARM CONTROL PANEL .F. FAHRENHEIT DEGREES FAHRENHEIT DEGREES FC FOOTCANDLE FOOTCANDLE FT. FEET FEET F.E. FIRE EXTINGUISHER FIRE EXTINGUISHER FDN. FOUNDATION FOUNDATION FIN. FINISH/FINISHED FINISH/FINISHED FIXT. FIXTURE FIXTURE FLEX. FLEXIBLE FLEXIBLE FL. FLOOR FLOOR FLA FULL LOAD AMPERES FULL LOAD AMPERES FLUOR. FLUORESCENT FLUORESCENT GA. GAGE/GAUGE GAGE/GAUGE GALV. GALVANIZED GALVANIZED G.C. GENERAL CONTRACTOR GENERAL CONTRACTOR GEN. GENERATOR GENERATOR GND. GROUND GROUND G.F.I. GROUND FAULT INTERRUPTER GROUND FAULT INTERRUPTER G.R.S.C. GALVANIZED RIGID STEEL CONDUIT GALVANIZED RIGID STEEL CONDUIT HT. HEIGHT HEIGHT H.I.D. HIGH INTENSITY DISCHARGE HIGH INTENSITY DISCHARGE HORIZ. HORIZONTAL HORIZONTAL H.O.A. HAND OFF AUTO HAND OFF AUTO HP. HORSEPOWER HORSEPOWER H.P.S. HIGH PRESSURE SODIUM HIGH PRESSURE SODIUM HZ. HERTZ HERTZ INC. INCANDESCENT INCANDESCENT IMC INTERMEDIATE CONDUIT INTERMEDIATE CONDUIT ISOL. ISOLATED ISOLATED INSUL. INSULATION/INSULATED INSULATION/INSULATED J JUNCTION BOX JUNCTION BOX KHZ KILOHERTZ KILOHERTZ KW KILOWATT KILOWATT KWH KILOWATT HOUR KILOWATT HOUR KVA KILOVOLT-AMPERE KILOVOLT-AMPERE KVAR KILOVAR KILOVAR KV KILOVOLT KILOVOLT LAN LOCAL AREA NETWORK LOCAL AREA NETWORK LG. LENGTH LENGTH LF LINEAR FEET LINEAR FEET LT LIGHT LIGHT LTG LIGHTING LIGHTING LRA LOCKED ROTOR AMPERES LOCKED ROTOR AMPERES LG LONG LONG MCC MOTOR CONTROL CENTER MOTOR CONTROL CENTER M.C. MECHANICAL CONTRACTOR MECHANICAL CONTRACTOR M/C MULTI-CONDUCTOR MULTI-CONDUCTOR MDS MAIN DISTRIBUTION SWITCHBOARD MAIN DISTRIBUTION SWITCHBOARD MDP MAIN DISTRIBUTION PANEL MAIN DISTRIBUTION PANEL MANUF. MANUFACTURER MANUFACTURER MF MAINTENANCE FACTOR MAINTENANCE FACTOR MAX. MAXIMUM MAXIMUM MB MAIN BREAKER MAIN BREAKER MECH. MECHANICAL MECHANICAL MCM THOUSAND CIRCULAR MILLS THOUSAND CIRCULAR MILLS MG MOTOR GENERATOR MOTOR GENERATOR MTD. MOUNTED MOUNTED MIN. MINIMUM MINIMUM M.L.O. MAIN LUGS ONLY MAIN LUGS ONLY MTS MANUAL TRANSFER SWITCH MANUAL TRANSFER SWITCH N. NEUTRAL NEUTRAL NC NORMAL CLOSED NORMAL CLOSED N.E.C. NATIONAL ELECTRICAL CODE NATIONAL ELECTRICAL CODE NEMA NATIONAL ELECTRICAL NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION MANUFACTURERS ASSOCIATION NIC NOT IN CONTRACT NOT IN CONTRACT NO NORMALLY OPEN NORMALLY OPEN NTS NOT TO SCALE NOT TO SCALE NO./# NUMBER NUMBER ɸ PHASE PHASE P.V.C. POLYVINYLCHLORIDE POLYVINYLCHLORIDE PB PULL BOX PULL BOX PNL. PANELBOARD PANELBOARD P.C. PLUMBING CONTRACTOR PLUMBING CONTRACTOR PRI. PRIMARY PRIMARY R. RADIUS RADIUS RF RADIO FREQUENCY RADIO FREQUENCY REBAR. REINFORCING BAR REINFORCING BAR RECEPT. RECEPTACLE RECEPTACLE REQ'D REQUIRED REQUIRED REV. REVISE/REVISION REVISE/REVISION REC. RECESSED RECESSED R..SW. REMOTE CONTROL SWITCH REMOTE CONTROL SWITCH RGS RIGID GALVANIZED STEEL CONDUIT RIGID GALVANIZED STEEL CONDUIT SECT. SECTION SECTION SEC. SECONDARY SECONDARY SERV. SERVICE SERVICE 1/C SINGLE CONDUCTOR SINGLE CONDUCTOR SK. SKETCH SKETCH SPECS. SPECIFICATIONS SPECIFICATIONS SQ. SQUARE SQUARE S.F. SQUARE FEET SQUARE FEET STA. STATION STATION SW. SWITCH SWITCH S.S. STAINLESS STEEL STAINLESS STEEL SW'BD SWITCHBOARD SWITCHBOARD SYM. SYMMETRICAL SYMMETRICAL SUSP. SUSPENDED SUSPENDED SEP. SEPARATE SEPARATE SHT. SHEET SHEET SIG. SIGNAL SIGNAL SN SOLID NEUTRAL SOLID NEUTRAL SURF. SURFACE SURFACE THRU THROUGH THROUGH TEL. TELEPHONE TELEPHONE TRANSF./XFMR TRANSFORMER TRANSFORMER TYP. TYPICAL TYPICAL U.O.C. UNLESS OTHERWISE NOTED UNLESS OTHERWISE NOTED U.R.F. UNDER RAISED FLOOR UNDER RAISED FLOOR VS. VERSUS VERSUS VERT. VERTICAL VERTICAL VD VOLTAGE DROP VOLTAGE DROP V. VOLTAGE/VOLTS VOLTAGE/VOLTS WP WEATHERPROOF WEATHERPROOF WD. WIDE WIDE W/ WITH WITH W/O WITHOUT WITHOUT W/I WROUGHT IRONWROUGHT IRON

AutoCAD SHX Text

DEMOLITION

AutoCAD SHX Text

RECEPTACLE

AutoCAD SHX Text

EMERGENCY LIGHT WITH BATTERY BACKUP

AutoCAD SHX Text

EXISTING

AutoCAD SHX Text

NEW WORK

AutoCAD SHX Text

GENERAL

AutoCAD SHX Text S

AutoCAD SHX Text M

AutoCAD SHX Text S

AutoCAD SHX Text

SINGLE-POLE SWITCH

AutoCAD SHX Text

MOTOR STARTER SWITCH

AutoCAD SHX Text

GFCI RECEPTACLE

AutoCAD SHX Text

GFCI

AutoCAD SHX Text M

AutoCAD SHX Text

XX-XX

AutoCAD SHX Text

(CIRCUIT DESIGNATION)

AutoCAD SHX Text

SINGLE-POLE KEYED SWITCH

AutoCAD SHX Text S

AutoCAD SHX Text K

AutoCAD SHX Text

DATA CONNECTION

AutoCAD SHX Text 1100 CHURCH STREET HONESDALE, PA 18431 570-253-0846 OFFICE 570-253-1935 FAX WWW.NEINFRA.COM

AutoCAD SHX Text

1. NO LIVE ELECTRICAL WORK IS PERMITTED. ALL ELECTRICAL SHUT DOWNS NO LIVE ELECTRICAL WORK IS PERMITTED. ALL ELECTRICAL SHUT DOWNS FOR CONNECTIONS MUST BE REQUESTED AND COORDINATED 2 WEEKS IN ADVANCE. 2. ALL INSTALLATIONS SHALL MEET ALL REQUIREMENTS OF THE LATEST ALL INSTALLATIONS SHALL MEET ALL REQUIREMENTS OF THE LATEST VERSION OF THE VA ELECTRICAL DESIGN MANUAL, NEC, AND NFPA 101. 3. AIC RATING OF PROVIDED CIRCUIT BREAKERS SHALL AT A MINIMUM AIC RATING OF PROVIDED CIRCUIT BREAKERS SHALL AT A MINIMUM MATCH THE AIC RATING OF THE PANEL IN WHICH IT IS INSTALLED.

AutoCAD SHX Text

GENERAL NOTE

AutoCAD SHX Text

TRANSIENT VOLTAGE SURGE SUPPRESSOR RECEPTACLE

AutoCAD SHX Text

TVSS

AutoCAD SHX Text L

AutoCAD SHX Text

DALE ENGLEHART

AutoCAD SHX Text

PROFESSIONAL

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text Y

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text L

AutoCAD SHX Text V

AutoCAD SHX Text M

AutoCAD SHX Text P

AutoCAD SHX Text C

AutoCAD SHX Text O

AutoCAD SHX Text No. PE045114E

AutoCAD SHX Text

ENGINEER

AutoCAD SHX Text

REGISTERED

AutoCAD SHX Text M

AutoCAD SHX Text W

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text I

AutoCAD SHX Text F

AutoCAD SHX Text H

AutoCAD SHX Text O

BUILDINGS 1D AND 10 NEW WORK

ELECTRICAL PLANS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

WATER MONITORING

AND TREATMENT

975 KIRMAN AVE.

RENO, NEVADA 89502

654-18-807

02/18/2021Revisions: Date: D.L.E.

SIERRA NEVADA VA HEALTH

CARE SYSTEM

A

1D & 10

EP-100

AutoCAD SHX Text

MECH L1XD12

AutoCAD SHX Text

TVSS

AutoCAD SHX Text

MSF-14

AutoCAD SHX Text

TVSS

AutoCAD SHX Text

LEC1B-20

AutoCAD SHX Text

TELEPHONE

AutoCAD SHX Text 2652B

AutoCAD SHX Text

MECH RM

AutoCAD SHX Text G2652A

AutoCAD SHX Text

ELECTRICAL

AutoCAD SHX Text G2652C

AutoCAD SHX Text 1100 CHURCH STREET HONESDALE, PA 18431 570-253-0846 OFFICE 570-253-1935 FAX WWW.NEINFRA.COM

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

L1902 NEW WORK ELECTRICAL PLAN

AutoCAD SHX Text 1/4"=1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

BUILDING 10 FIRST FLOOR MECH ROOM

AutoCAD SHX Text

EP-100

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

G1542 NEW WORK ELECTRICAL PLAN

AutoCAD SHX Text 1/2"=1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

BUILDING 1D FIRST FLOOR MECH ROOM

AutoCAD SHX Text

EP-100

AutoCAD SHX Text

GENERAL NOTE:

AutoCAD SHX Text 1.

AutoCAD SHX Text ALL INSTALLED CIRCUIT BREAKERS SHALL BE OF THE SAME MANUFACTURER AND SHALL MATCH OR EXCEED THE AIC RATING OF THE PANEL IN WHICH THEY ARE BEING INSTALLED OR THAT OF THE FEEDER CIRCUIT BREAKER

AutoCAD SHX Text 2.

AutoCAD SHX Text CONTRACTOR SHALL FIELD VERIFY ALL CONNECTIONS TO THE BMS SYSTEM PRIOR TO INSTALLATION. ALL WORK SHALL BE COORDINATED WITH THE COR.

AutoCAD SHX Text

KEYED NOTES:

AutoCAD SHX Text

WATER MONITORING PANEL. SEE PLUMBING NEW WORK PLANS.

AutoCAD SHX Text PROVIDE ONE (1) TVSS DUPLEX RECEPTACLE FOR WATER MONITORING PANEL. PROVIDE 20A SINGLE POLE CIRCUIT BREAKER IN LOCAL EMERGENCY PANELBOARD. PROVIDE 2-#12 CONDUCTORS AND 1-#12 GROUND IN 3/4" CONDUIT.

AutoCAD SHX Text

PROVIDE DATA CONNECTION FOR WATER MONITORING PANEL. TIE INTO LOCAL BMS SYSTEM.

AutoCAD SHX Text

EXISTING JOHNSON CONTROL PANEL

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

BUILDING 1D FIRST FLOOR KEY PLAN

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text

TRUE NORTH

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

BUILDING 10 FIRST FLOOR KEY PLAN

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text

TRUE NORTH

AutoCAD SHX Text N

AutoCAD SHX Text

PROJECT NORTH

AutoCAD SHX Text N

AutoCAD SHX Text

PROJECT NORTH

AutoCAD SHX Text

KEYED ELECTRICAL PANEL NOTES

AutoCAD SHX Text

PANEL LEC1B 120/208V

AutoCAD SHX Text

PANEL MSF 120/208V

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

G2652C ELECTRICAL ROOM PLAN

AutoCAD SHX Text 1/4"=1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

BUILDING 1D SECOND FLOOR ROOM

AutoCAD SHX Text

EP-100

AutoCAD SHX Text

PROJECT NORTH

AutoCAD SHX Text N

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

BUILDING 1D SECOND FLOOR KEY PLAN

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text

TRUE NORTH

AutoCAD SHX Text L

AutoCAD SHX Text

DALE ENGLEHART

AutoCAD SHX Text

PROFESSIONAL

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text Y

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text L

AutoCAD SHX Text V

AutoCAD SHX Text M

AutoCAD SHX Text P

AutoCAD SHX Text C

AutoCAD SHX Text O

AutoCAD SHX Text No. PE045114E

AutoCAD SHX Text

ENGINEER

AutoCAD SHX Text

REGISTERED

AutoCAD SHX Text M

AutoCAD SHX Text W

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text I

AutoCAD SHX Text F

AutoCAD SHX Text H

BUILDING 12 NEW WORK ELECTRICAL PLANS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

WATER MONITORING

AND TREATMENT

975 KIRMAN AVE.

RENO, NEVADA 89502

654-18-807

02/18/2021Revisions: Date: D.L.E.

SIERRA NEVADA VA HEALTH

CARE SYSTEM

A

EP-101

AutoCAD SHX Text

ELECTRICAL B1165

AutoCAD SHX Text

EXAM B1163

AutoCAD SHX Text

EXAM B1136

AutoCAD SHX Text

TELE B1167

AutoCAD SHX Text

TVSS

AutoCAD SHX Text

GELA-22

AutoCAD SHX Text 1100 CHURCH STREET HONESDALE, PA 18431 570-253-0846 OFFICE 570-253-1935 FAX WWW.NEINFRA.COM

AutoCAD SHX Text

GENERAL NOTE:

AutoCAD SHX Text 1.

AutoCAD SHX Text ALL INSTALLED CIRCUIT BREAKERS SHALL BE OF THE SAME MANUFACTURER AND SHALL MATCH OR EXCEED THE AIC RATING OF THE PANEL IN WHICH THEY ARE BEING INSTALLED OR THAT OF THE FEEDER CIRCUIT BREAKER

AutoCAD SHX Text 2.

AutoCAD SHX Text CONTRACTOR SHALL FIELD VERIFY ALL CONNECTIONS TO THE BMS SYSTEM PRIOR TO INSTALLATION. ALL WORK SHALL BE COORDINATED WITH THE COR.

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

BUILDING 12 FIRST FLOOR KEY PLAN

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text

TRUE NORTH

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

B1165 NEW WORK ELECTRICAL PLAN

AutoCAD SHX Text 1/4"=1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

BUILDING 12 FIRST FLOOR ROOM

AutoCAD SHX Text

EP-101

AutoCAD SHX Text N

AutoCAD SHX Text

PROJECT NORTH

AutoCAD SHX Text

KEYED ELECTRICAL PANEL NOTES

AutoCAD SHX Text

PANEL GELA 120/208V

AutoCAD SHX Text

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

NEW WORK ELECTRICAL PLAN

AutoCAD SHX Text 1/4"=1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

BUILDING 12 BASEMENT ROOM B0100

AutoCAD SHX Text

EP-101

AutoCAD SHX Text N

AutoCAD SHX Text

PROJECT NORTH

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

BUILDING 12 BASEMENT KEY PLAN

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text

TRUE NORTH

AutoCAD SHX Text

KEYED NOTES:

AutoCAD SHX Text

WATER MONITORING PANEL. SEE PLUMBING NEW WORK PLANS.

AutoCAD SHX Text PROVIDE ONE (1) TVSS DUPLEX RECEPTACLE FOR WATER MONITORING PANEL. PROVIDE 20A SINGLE POLE CIRCUIT BREAKER IN LOCAL EMERGENCY PANELBOARD. PROVIDE 2-#12 CONDUCTORS AND 1-#12 GROUND IN 3/4" CONDUIT.

AutoCAD SHX Text

PROVIDE DATA CONNECTION FOR WATER MONITORING PANEL. TIE INTO LOCAL BMS SYSTEM.

AutoCAD SHX Text

EXISTING JOHNSON CONTROL PANEL

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text L

AutoCAD SHX Text

DALE ENGLEHART

AutoCAD SHX Text

PROFESSIONAL

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text Y

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text L

AutoCAD SHX Text V

AutoCAD SHX Text M

AutoCAD SHX Text P

AutoCAD SHX Text C

AutoCAD SHX Text O

AutoCAD SHX Text No. PE045114E

AutoCAD SHX Text

ENGINEER

AutoCAD SHX Text

REGISTERED

AutoCAD SHX Text M

AutoCAD SHX Text W

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text I

AutoCAD SHX Text F

AutoCAD SHX Text H

Sheets and Views
654-18-807 -SNVAMC-006-1-E-001- SYMB, NOTES, ABBREV-E-001
654-18-807 -SNVAMC-006-1-E-100-NEW WORK-EP-100
654-18-807 -SNVAMC-006-1-E-100-NEW WORK-EP-101

File details come from the government source that posted it. Updated .