This document provides details on a forthcoming federal contract solicitation for mechanical deficiency corrections at a Department of Veterans Affairs medical center. The solicitation will require installation of three new boilers and demolition of existing boilers within 425 calendar days. The contract is set aside for Service-Disabled Veteran Owned Small Businesses and has an estimated value between $5-10 million. Responses are due in August 2021 according to the pre-solicitation notice. Offerors must be SDVOSB-certified, registered in SAM, and complete various veteran ownership representations. The work involves providing all equipment, labor and supervision to replace boilers serving the Omaha VA Medical Center while maintaining steam production capabilities.
View the file
Other files for this federal contract opportunity
Show all 22
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2-CTP
2-CTP
2-FWP
2-FWP2 (E)
2-FWP1 (E)
CONDENSATE
TANK (E)
CONCRETE
PAD (N)
CONCRETE
PAD (N)
2-CTP
2-CTP
GATE VALVE (N)
(TYP.)
CHECK VALVE (N)
(TYP.)
3" CT (N)
FLEX CONNECTION (N)
(TYP.)
4" CT
3" CT
3" CT (N)
BF
CONCRET PAD, VERIFY SIZE
WITH EQUIPMENT PROVIDED (N)
FLEX CONNECTION (N)
(TYP.)
GATE VALVE (E)
(TYP.)
STRAINER (E)
GATE VALVE (E)
2-FWP
2-FWP-2
2-FWP-1
3" BFW1
3" BFW1 3" BFW1
EXISTING
CONC. PAD
2MP301
3___
2MP301
2___
2-CTP
2-CTP
2-FWP
32-FWP-22-FWP-1
CONDENSATE
TANK (E)
3" CT
4" CT
3" CT
3" BFW1
3" BFW1
2-FWP
(N)
2-FWP2 (E)
2-FWP1 (E)
CONCRETE
PAD (E)
2-CTP
2-CTP
OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY
FARRIS ENGINEERING
farris-usa.com
FE#:202013
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
ARCHITECT/ENGINEERS:STAMPCONSULTANTS:
321 4 5 6 7 8 9 10
OMAHA VAMC - CORRECT
MECHANICAL DEFICIENCIES
05-14-2021 GTK CWK
OMAHA, NE
636-19-301
100% CD SUBMITTAL
C U s e rs
\c w k \D o c u m e n ts
\2
M E
C e n tr a l
R c k e ff e r@ fa rr is -u s a .c o m
.r v t
/1
/2
:5
:3
A
M
2MP301
MECHANICAL PARITAL PLAN,
SECTIONS AND ISOMETRIC
SCALE:
4 MECHANICAL PIPING ISOMETRIC - CTP
SCALE: 1/2" = 1'-0"
2 SECTION AT PUMPS 2-CTP1 & 2
SCALE: 1/2" = 1'-0"
3 SECTION AT PUMP 2-FWP-3
SCALE: 1/4" = 1'-0"
1 FIRST FLOOR PLAN
SCALE:
5 MECHANICAL PIPING ISOMETRIC -FWP
Revisions: Date: