This Statement of Work (SOW) details a procurement for the United States Coast Guard Training Center Yorktown to replace 33 Self-Contained Breathing Apparatus (SCBA) cylinders used in Damage Controlman (DC) firefighting training schools. The requirement is specifically for 33 G1 low profile cylinders with dove tail configuration, rated at 4,500 PSI, to support Terminal Performance Objectives (TPO) 8.1 through 8.9, 1.3 and 3.1. The cylinders must match the specifications of current equipment in use, as specified in Maintenance Procedure Card R-Q-17849 and Naval Ships Technical Manual 077.
The government will provide a forklift with a licensed operator for offloading the equipment upon delivery. The Contracting Officer's Representative (COR) will review deliverables within 30 days and has the right to reject or require correction of any deficiencies. The contractor is responsible for freight transportation to Training Center Yorktown (TCY), and no other government resources will be furnished in support of this contract. The procurement is focused solely on replacing end-of-life SCBA cylinders to maintain firefighting training capabilities.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 12a. Provisions and Clauses.pdf | ||
| 12a. Maintenance Procedure Card.pdf | ||
| 12a. Naval Ships Technical Manual 077.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PR# 63100PR260007463
STATEMENT OF WORK DC SCHOOL SCBA CYLINDERS
STATEMENT OF WORK (SOW)
FOR
PURCHASE REPLACEMENT SCBA CYLINDERS WITH DOVE TAIL CONFIGURATION
1.0 GENERAL
1.1 BACKGROUND
United States Coast Guard Training Center Yorktown hosts Damage Controlman (DC) schools for firefighting in both “A” and “C” schools. DC school has 42 SCBA cylinders to conduct training in Terminal Performance Objectives (TPO) 8.1 through 8.9, 1.3 and 3.1; 33 of which need to be replaced due to end-of-life service requirements.
1.2 OBJECTIVE
The main objective for this statement of work is to have the 33 cylinders that have reached the end-of-life service requirements replaced with matching configurations of the G1 fire responder packs. These cylinders are required to support the above TPO’s in firefighting.
These specifications match the current cylinders in use and will provide the needed on-air rating and dove tail configuration as specified per Maintenance Procedure Card R-Q-17849 and Naval Ships Technical Manual 077, Personal Protective Equipment.
1.3 APPLICABLE DOCUMENTS
1.3.1 Attachment 1: Naval Ships Technical Manual 077, Personal Protective Equipment
1.3.2 Attachment 2: Maintenance Procedure Card R-Q-17849
2.0 SPECIFIC REQUIREMENTS/TASKS
2.1 Contractor will supply thirty-three (33) G1 low profile cylinders with the dove tail configuration and rated at 4,500 PSI.
2.2 FOB Destination: Contractor will be responsible for freight transportation to TRAINING
CENTER YORKTOWN (TCY).
3.3 KEY PERSONNEL
N/A
4.0 OTHER APPLICABLE CONDITIONS
N/A
PR# 63100PR260007463
STATEMENT OF WORK DC SCHOOL SCBA CYLINDERS
5.0 GOVERNMENT FURNISHED RESOURCES
Training Center Yorktown will furnish a forklift with a licensed operator to offload equipment upon delivery. No other resources will be furnished to the Contractor in support of this contract.
6.0 CONTRACTOR FURNISHED PROPERTY
N/A
7.0 GOVERNMENT ACCEPTANCE PERIOD
The COR will review deliverables prior to acceptance, within 30 days. The COR will have the right to reject or require correction of any deficiencies found in the deliverables.
8.0 DELIVERABLES