620A4 18 212 Bid Docs Drawings.pdf
PDF 26 MB Posted
- Attached to
- Y1DA--620A4-18-212 Pharmacy USP 800 Renovation
- Solicitation number
- 36C24223B0001
About this file
This solicitation is for a Pharmacy USP 800 Renovation project for the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 2. The solicitation seeks bids for construction services to renovate pharmacy spaces in accordance with USP 800 standards for hazardous drugs. Small businesses are encouraged to respond. Bids are due by April 15, 2022 and the contract is expected to be awarded by May 15, 2022. The renovation scope includes construction of a new containment segregated compounding area, hazardous drug storage room, and anteroom with interlocking doors. Facility upgrades such as HVAC, plumbing and electrical work are also required. The project is to be completed within 180 calendar days of the award date.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24223B0001 0001.docx | DOCX document | |
| 620A4 18 212 Bid Docs Specs Volume II.pdf | ||
| 620A4 18 212 Bid Docs Specs Volume I.pdf | ||
| Salient Characteristics 620A4 18 212.pdf | ||
| WAGE DETERMINATION 02.pdf | ||
| 36C24223B0001_1.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LOCATION MAP SITE MAP
DRAWING INDEX
AREA OF WORK
BUILDING #15H
PROJECT LOCATION
COVER SHEET
& DRAWING INDEX
GI001
HWRMP
NO. DESCRIPTION DATE
B
A
C
D
E
F
1 2 3 4 5 6 87 9
97 8654321
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0116
B
A
C
D
E
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ENGINEER OF RECORDCONSULTANT PHARMACY USP 800 RENOVATION 620A4-18-212
15H
Project Director
2022-08-24
CASTLE POINT CAMPUS
WAPPINGERS FALLS, NY
NORTH
PULL
A .F
.F M
A X
RADIOLOGY
RECORDS
RECOVERY
RECEPTION
M
MAINT
MECH
MACH MACHINE ROOM
MALE
MAINTENANCE
RECD
RECP
RECOV
RAD
ROOM
STAFF
REHABILITATION
SHOWER
SUPPLY
STAFF TOILET
SOILED UTILITY
SECRETARY
STAIRS
SUPPORT
STATION
STERILIZER
SERVICE
SWITCHGEAR
SUPERVISOR
SURGERY/ ICAL
STORAGE
MGR
MED
MRI
OFF
OR
ORTHO
OH
OB/GYN
OPERATING ROOM
MANAGER
OFFICE
MEDICATION/ MEDICAL
ORTHOPEDICS
OBSTETRICS/ GYNECOLOGY
ORAL HYGIENIST
MAGNETIC RESONANCE
IMAGING
SWGR
ST
STA
RM
S TLT
SVCE
SHR
S
STOR
SUPVR
SPRT
SPLY
SOIL
SECY
REHAB
STER
SURG
MECHANIC(AL)
EDUCATION
ELEVATOR
ELECTRIC(AL)
ED
ELEV
EMG
ELEC
ADMIN
ASSY
AUD
AMB
ASSEMBLY
ADMINISTRATION(OR)
AMBULATORY
AUDIOLOGY
"DN"
S
SIMILARSIM
SPEC
SF
SOUTH/ SINK
SQUARE FEET/ STOREFRONT
(NON - NCS ABBREVIATIONS ARE SHOWN
UNDERLINED) EXAMPLE:
ENDOSCOPY
EQUIPMENT
EXECUTIVE
ENDO
ENT
EQUIP
EXEC
FREEZER
FEMALE
FRZ
F
BALCONYBALC
CHEMICALCHEM
CHGN
CLASSCL
CHIRO CHIROPRACTOR
CHARGE NURSE
GENERAL
GYMNASIUM
GEN
GYM
HEAD
HOUSEKEEPINGHSKPG
HD
ICCU
HAZ MAT
CLERICAL
CLN
CLER
CLOSETCLO
CLRM CLASSROOM
CLEAN (ING)/ CLEAN UTILITY
COMM
CONF
CORRIDORCORR
COPY
COMMUNICATIONS
CONFERENCE
COPY/ WORK ROOM
COMMANDER/ COMMANDCMD
SQUARESQ
SST
STEEL
STC
STL
TREADT
THROUGHTHRU
TEMP
SOUND TRANSMISSION CLASS
STAINLESS STEEL
TEMPERATURE/ TEMPORARY
TOP OF
TOC
TO
TOF
TOM
TYPICALTYP
U
UC
TOS
HEAT TRANSFER COEFFICIENT
TOP OF FOOTING
TOP OF CONCRETE (CURB)
UNDERCUT
TOP OF MASONRY
TOP OF STEEL
SPECIFICATION(S)
HAZARDOUS MATERIALS
EAR NOSE THROAT
ELECTROMYOGRAPHY
INTENSIVE CARDIAC CARE UNIT
TECHNICIAN
TELEPHONE
TOILET
URINAL
TREATMENT
WAITING
WAREHOUSE
WATER CLOSET
WEIGHTS AND MEASURES
WEIGHT
WORK STATION, WORK ROOM
EXECUTIVE OFFICER
VESTIBULE
P
PHAR
PHYS
PEDS
PO
PYSCH
PRIN
PREP
POST OFFICE
PRINCIPAL
PHARMACY
PATIENT
PREPARATION
PEDIATRICS
PHYSICAL
PSYCHOLOGY
PROCTO
PROC
PUB
PT/OT
PULMO
PUBLIC
PHYSICAL / OCCUPATIONAL
THERAPY
PROCTOLOGY
PROCEDURE
PULMONARY
PARKINGPRKG
WT
WHSE
WAIT
VEST
UR
WORK
TRT
TECH
XO
WC
W & M
TEL
TLT
INFORMATION
ISOLATION
INJECTION
INFO
ICU
ISO
INJ
JANITOR
KITCHEN
JAN
JC
KIT
CSR
CT
CONTROLCTRL
CENTRAL STERILE ROOM
CAT SCAN
DRESSING
DEPT
D
DIRECTOR
DICTATION
DIR
DICT
DEPARTMENT
LAUNDRY
LABORATORY
LAU
LAB
LDRP
LCPO
LIBRARY
LOCKER
LIT/ FORMS
LIB
LPO
LKR
L/W
L/F
DOCTORDR
DOR
DRK
DTR
DARKROOM
DENTAL TREATMENT ROOM
DENTAL OPERATORY ROOM
DISP DISPENSING
UL
U/C/B
VACUUMV
U0N
VARIESVAR
VCT
VERTICAL
VTR
VERT
VENT THRU ROOF
UNLESS OTHERWISE NOTED
UNDERWRITERS LABORATORY
VINYL COMPOSITION TILE
UNDER COUNTER BASE
W
WITHW/
W
WITHOUT
WOOD
W/0
WD
WEIGHTWT
WP
WH WALL HUNG/ WATER HEATER
WEST /WATT
WATERPROOF / WORKING POINT
WIDTH /WIDE FLANGE
VWC VINYL WALL COVERING
WWF WELDED WIRE FABRIC
JANITOR'S CLOSET
LABOR DELIVERY RECOVERY POST PARTUM
LEADING CHIEF PETTY OFFICER
LEADING PETTY OFFICER
LITTER WHEELCHAIR
INTENSIVE CARE UNIT
KILOPASCAL
POUND
ANGLE
KPA
L
LB
EACH
ELEVATION
EACH END
EXPANSION JOINT
EA
EJ
EL
EE
AND&
DOLLAR (USD)
@ AT
NUMBER / POUND
NATIONAL CAD STANDARD ABBREVIATIONS
LINEAR FEET
METERS
MAXIMUM
LF
M
MAX
MINIMUM
MILLIMETERS
MISCELLANEOUS
MASONRY OPENING
MIN
MM
MISC
MO
ET CETERA
EQUAL
EYE WASH STATION
ELECTRIC WATER COOLER
EXISTING
FILLER
NORTH
NOT APPLICABLE
NUMBER
NOT IN CONTRACT
NA
N
NO
NIC
NOT TO SCALE
OXYGEN
ON CENTER
NTS
OC
O
NOMINALNOM
FACSIMILE
FIRE EXTINGUISHER
FINISHED FLOOR
FIRE EXTINGUISHER CABINET
FLOOR
FACE OF
FIBERGLASS REINFORCED POLYMER
FACE OF SLAB (STUD)
FIRE HOSE CABINET
EQ
F
A/C
A/E
ADA
ACT
AHJ
AHU
AFF
ALUM
AUTHORITY HAVING JURISDICTION
AMERICANS WITH DISABILITY ACT
ACOUSTICAL CEILING TILE
ABOVE FINISHED FLOOR
AIR HANDLING UNIT
ALUMINUM
ARCHITECT-ENGINEER
AIR CONDITIONED
FE
FF
FLR
FO
FRP
BEAM
BLDG
BM
BOS
BO
CG
CCT
CL
CJ
BUILDING
BOTTOM OF STEEL
CENTER LINE
CONTROL/ CONSTRUCTION JOINT
CORNER GUARD
BY OWNER/ BOTTOM OF
CUBICLE CURTAIN TRACK
FOS
FAX
EWS
ETC
FEC
FHC
EXIST
EWC
OPPOSITE HAND
OUTSIDE DIAMETER
PLATE
OPENING
OPH
OD
PL
OPNG
PAIR
PLASTIC LAMINATEPLAM
PR
PSI
PSF
GAS
GRAB BAR
GALVANIZED
GAGE
HIGH
GYPSUM BOARD
GENERAL CONTRACTOR
QUANTITY
PTS
QTY
RISER/RADIUS
REQUIRED
ROUGH OPENING
RENOVATE(TION)
R
RAL
RO
REQ
RENOHARDWARE
HOUR
HOLLOW METAL
INTERCOM
INTRAVENOUS
INCH(ES)
INSIDE DIAMETER
PT
HANDICAP
G
GB
GA
GC
H
CLL
CLG
CM
CMU
CLR CLEAR
CONC
CO2
CONT
CTJ
CENTIMETER
CONCRETE
COLUMN LINE
CONTINUED (OUS)
CONCRETE MASONRY UNIT
CEILING
CONTRACTION JOINT
CARBON DIOXIDE
HM
HR
ID
IC
IV
INCTR
DBA
D
DEG
DIA
DR
DWG
DN DOWN
DEGREE
UNIT OF SOUND
CENTER
DEEP/ DEPTH
DIAMETER
DOOR/
DRAWING(S)
COORDINATECOORD
HC
HDW
GALV
GYP BD
ROICC
JOINTJT
DWR DRAWER
PAINT
POUNDS/SQUARE FOOT
POUNDS/SQUARE INCH
RESIDENT OFFICER IN CHARGE
OF CONST
FEDERAL COLOR PALETTE
PNEUMATIC TUBE STATION
VOL VOLUNTEER
ASSISTANTAST
COMPUTERCOMP
COORD COORDINATOR
CLIN CLINIC (AL)
PERSONNELPERS
MANAGEMENTMGNTANALYSISTANLST
COMPR COMPTROLLER
CUBICLESCBCL
DEGREE(S)°
AIR
A
/ DIVIDE BY, PER
EQUALS, EQUAL TO
' FOOT, FEET
> GREATER THAN
> GREATER THAN OR EQUAL TO
INCH(ES)"
MINUS, NEGATIVE
< LESS THAN
LESS THAN OR EQUAL TO
MULTIPLY BY, BYX
% PERCENT
PLUS
+/- PLUS OR MINUS
NATIONAL CAD STANDARD ROOM NAME ABBREVIATIONS
"DN"
(NON - NCS ABBREVIATIONS ARE SHOWN
UNDERLINED) EXAMPLE:
FOOT/FEETFT
TELEVISIONT.V.
P.T. PRESSURE TREATED
MOUNTEDMNTD
FIRE RETARDANTF.R.
SS STAINLESS STEEL
WHEELCHAIRW/C
FIRE TREATEDF.T.
ABA ARCHITECTURAL BARRIERS ACT
SAB SOUND ATTENUATION BATTS
EXPOSEDEXP
DEMO DEMOLISH
A101
SIM
A101
SIM
A101
SIM
BUILDING ELEVATION/SECTIONDetail No.
Sheet No.
Reference Label
Detail No.
Sheet No.
Reference Label
Detail No.
Sheet No.
Reference Label
Room No.
Room Area
Door/Room No.
Partition Configuration
Partition Configuration
Key Note No.
ALIGN
WALL SECTION
DETAIL SECTION/CALLOUT
ROOM TAG
DOOR TAG
PARTITION TAG
KEYNOTE
ALIGNED SURFACES
Room Name
150 SF
Room Name
Area
AREA TAG
Area NameArea Name
150 SF
WL_Type 2S 86
SCOPE OF PROJECT
Project Limit Line
Grid No.
CENTERLINE
COLUMN GRID LINE
SPOT ELEVATIONSpot Elevation AFF
Level/Datum Elevation AFF
LEVEL MARKER
Level/Datum Name
Window Type WINDOW TYPE TAG1t
CL
Highpoint @ Tail SLOPE INDICATOR
Starting Point @ Center DIMENSION CROSSHAIR
NORTH ARROW
Plan North Reference Label
Name Elevation
Revision Reference Number
Revision Cloud Depicting Area Revised
REVISION
CEILING TAG1'-0" Clg Height
0' - 8" 0' - 8"
AUDIO/VISUAL
FIRE ALARM
EXIT SIGN WALL
SWITCH
WALL
PHONE
JACK
FIRE ALARM
PULL STATION
(GENERALLY
LOCATE UNDER
A/V ALARM)
T.V./DATA/
PHONE
POWER
RECEPTACLES
LIGHT
SWITCHES
OCCUPANCY
SENSOR
CARD
READER
THERMOSTAT
POWER
DISCONNECT
REMOTE DOOR
RELEASE
" 3
TYPICAL
WORKSTATION
ASSEMBLY
3' - 3"
CLEAR
2' - 6"
D/V L
TV
D/V
TV E
E
ED/V
L L OS CR T DR
E
EM E
D/V
SOAP
DISPENSER
HAND SANITIZER
DISPENSER
GLOVE BOX
DISPENSER
M A
X
IM
U M
FIRE
EXTINGUISHE
R WALL
HUNG
FIRE
EXTINGUISHER
IN RECESSED
CABINET
METAL TRIM
LETTERS BY
CABINET
MANUFACTURER
CONTINUOUS
HINGE
SEE FLOOR
PLAN FOR
PARTITION TYPE
METAL PULL
F I
R E
E X
T I
N G
U I
S H
E R
METAL STUDS
EACH SIDE OF CABINET
GYP. BD.
PLAN ELEVATION
SIZE FIRE EXTINGUISHER CABINET LARGE ENOUGH TO
HANDLE A 2.5-GALLON PRESSURIZED WATER EXTINGUISHER.
VISION PANEL
RECESSED FIRE EXTINGUISHER
CABINET; INTERIOR DIMENSIONS:
8" X 8" X 27"
A S e rv ic e
D i s a b le d
Ve t e r an Owned S m a l l B u s iness
SDVOSB
CVE
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0116
Drawing Title
Approved: Project Director
Project Title
Issue Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANT Office of o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t 6 o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
NO. DESCRIPTION DATE
PLAN
NORTH
PHARMACY USP 800 RENOVATION 620A4-18-212
15H
U.S. Department of Veterans Affairs
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
ACTUAL
NORTH
Phase
BID DOCUMENTS
FULLY SPRINKLERED
Construction and Facilities Management
ENGINEER OF RECORD GENERAL NOTES, SYMBOLS, ABBREVIATIONS,
STANDARD & BARRIER FREE MOUNTING
HEIGHTS
G-001 2022-08-24
CASTLE POINT CAMPUS
WAPPINGERS FALLS, NY
JBS JDW
ABBREVIATIONS PLAN SYMBOLS
COLOR & MATERIAL ABBREV.
ACT ACOUSTIC CEILING TILE & GRID
ACT (SC) ACOUSTIC CEILING TILE & GRID (SPECIALTY COATING)
ACT (SP) ACOUSTIC CEILING TILE & GRID (WITH SPRAYED PLASTIC FINISH)
C CONCRETE
CC CUBICLE CURTAIN
CG CORNER GUARD
CPT MODULAR CARPET TILE
CS CONCRETE SEALER
CT CERAMIC TILE
CWT CERAMIC WALL TILE
EF ENTRANCE FLOORING
EFTR EXISTING FINISH TO REMAIN
EPY EPOXY FLOOR
EX EXISTING
EXP EXPOSED
GL GLASS (GLAZING)
GRT GROUT
GT GLASS TILE
GWB GYPSUM BOARD
GWB (SC) GYPSUM BOARD (WITH SPECIAL COATING)
ME MATCH EXISTING
MP METAL PAINT
PBT PORCELAIN TILE - COVE BASE
PFT PORCELAIN FLOOR TILE
PL PLASTIC LAMINATE
PT PAINT
PT(A) PAINT - FLAT FINISH
PT(B) PAINT - EGGSHELL FINISH
PT(C) PAINT - ALKYD/ ENAMEL FINISH
PT(D) PAINT - EPOXY
PWT PORCELAIN WALL TILE
QT QUARRY TILE
RB RUBBER BASE
RS RUBBER SHEET
RT RUBBER TILE
SDT STATIC DISSIPATIVE TILE
SQA SOLID QUARTZ AGGREGATE
SS SOLID SURFACE
TP TOILET PARTITION
TS TRANSITION STRIP
VCT VINYL COMPOSITION TILE
WD WOOD DOOR
WF WALL FABRIC
WP WALL PROTECTION - SHEET
WT WINDOW TREATMENT
WV WALL VINYL
PLAN SYMBOLS
ELECTRICAL CONTROL DEVICES
STANDARD & BARRIER FREE MOUNTING HEIGHTS
EQUIPMENT AND ACCESSORIES FIRE PROTECTION EQUIPMENT
1 1/2" = 1'-0"F8 FEC
H A
N D
IC
A
P S
P A
C E
S
WOODED AREA
WOODED AREA
O/S 16
O/S 03
O/S 04
WOODED AREA
PARCEL 1
112.851 ACRES
APPROXIMATE
PROJECT LIMITS
X X
X X
X X
X X
X
X
X
X X
X
X
X
X
X
NO. DESCRIPTION DATE
B
A
C
D
E
F
1 2 3 4 5 6 87 9
97 8654321
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0116
B
A
C
D
E
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ENGINEER OF RECORDCONSULTANT PHARMACY USP 800 RENOVATION 620A4-18-212
15H
Project Director
2022-08-24
CASTLE POINT CAMPUS
WAPPINGERS FALLS, NY
CONSTRUCTION SITE
LOGISTICS PLAN
G-002
ARFDJ
DN
UP
PATH OF TRAVEL (FEET)
EXIT FLOW
START OF TRAVEL
WALL MOUNTED EXIT SIGN
(COORDINATE W/ ELECTRICAL)
RECESSED CABINET FIRE EXTINGUISHER
(COORDINATE W/ FIRE MARSHAL)
TWO HOUR FIRE WALL CONSTRUCTION
BUSINESS OCCUPANCY
ONE HOUR FIRE WALL CONSTRUCTION
EXISTING ELECTRICAL EXIT SIGN
125 SF
ADMIN OFFICE
251C
66 SF
ADMIN OFFICE
251B
154 SF
ADMIN OFFICE
251D
155 SF
RECEPTION
341 SF
ROLLING SHELF
STORAGE
246C
551 SF
PRESCRIPTION
AREA
246B
52 SF
COMM. CLOSET
61 SF
ELECT. CLOSET
220 SF
RECEIVING
STAGING
246A
444 SF
RECEIVING
STAGING
90 SF
ADMIN OFFICE
129 SF
PRESCRIPTION
RECEPTION
45 SF
STORAGE
100 SF
CLINIC EXAM
223 SF
BULK STORAGE
251F
53 SF
MENS TOILET
52 SF
WOMENS TOILET
292 SF
STAFF LOUNGE
251E
134 SF
CLINIC EXAM
144 SF
NEG. BUFFER
250D
140 SF
NEG. ANTE
250C-B
186 SF
POS. ANTE
103 SF
POS. BUFFER
250A
44 SF
RECEIVING /
BREAK DOWN
249B
147 SF
PRESCRIPTION
VAULT
171 SF
SECURED
DISPENSING
249A
761 SF
MECHANICAL
ROOM
87 SF
ELEVATOR
95 SF
ELEVATOR
199 SF
STAIR
H-01
882 SF
LOBBY AREA
C2-03A
80 SF
WOMENS TOILET
49 SF
EMS CLOSET
73 SF
MENS TOILET
339 SF
CONFERENCE
ROOM
58 SF
WOMENS TOILET
52 SF
MENS TOILET
1019 SF
CORRIDOR
C2-03B
212 SF
ELEVTOR LOBBY
C2-01
887 SF
CORRIDOR
C2-02
130 SF
CLINIC EXAM
140 SF
CLINIC EXAM
103 SF
CLINIC EXAM
129 SF
CLINIC EXAM
H-228
129 SF
CLINIC EXAM
H-227
99 SF
CHEMO PREP
H-226
103 SF
CLINIC EXAM
H-225
104 SF
CLINIC EXAM
H-224
89 SF
CLINIC EXAM
H-223
146 SF
CLINIC EXAM
H-242
119 SF
CLINIC EXAM
H-241
113 SF
CLINIC EXAM
H240
93 SF
CLINIC EXAM
97 SF
CLINIC EXAM
93 SF
CLINIC EXAM
311 SF
CORRIDOR
C2-08
343 SF
CORRIDOR
C2-07
219 SF
CORRIDOR
C2-06
219 SF
SPECIALTY
CLINIC
RECEPTION
84 SF
CLINIC EXAM
1275 SF
OPTI-FILL 2 AREA
246D
201 SF
CHEMO NURSE
STATION
H-220
142 SF
PRIVATE
TREATMENT
H-220C
94 SF
ONCOLOGY EXAM
H-221 21 SF
STOR.
H-222A
461 SF
CORRIDOR
C2-04
187 SF
STAIR
H-02
111 SF
ONCOLOGY EXAM
H-213
246I
117 SF
ONCOLOGY EXAM
H-214
120 SF
ONCOLOGY EXAM
H-215
103 SF
ONCOLOGY EXAM
H-216
213 SF
CORRIDOR
C2-05
77 SF
PATIENT TOILET
H-220B
409 SF
CHEMO
TREATMENT
ROOM
H-220A 10 SF
STOR.
220D
10 SF
ELEC. CL.
H-222B
6 SF
M.C.03
6 SF
M.C.02
8 SF
M.C.01
106 SF
ONCOLOGY EXAM
H-218
93 SF
ONCOLOGY EXAM
H-217
59 SF
ONCOLOGY EXAM
H-219
PATH
"COMMON"
PATH "A"
PATH "B"
PATH "A"
CLEAN
AGENT
49 SF
AIRLOCK
250C
PROJECT LOCATION
A S e rv ic e
D i s a b le d
Ve t e r an Owned S m a l l B u s iness
SDVOSB
CVE
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0116
Drawing Title
Approved: Project Director
Project Title
Issue Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANT Office of o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t 6 o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
NO. DESCRIPTION DATE
PLAN
NORTH
PHARMACY USP 800 RENOVATION 620A4-18-212
15H
U.S. Department of Veterans Affairs
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
ACTUAL
NORTH
Phase
BID DOCUMENTS
FULLY SPRINKLERED
Construction and Facilities Management
ENGINEER OF RECORD LIFE SAFETY SHEET
G-003 2022-08-24
CASTLE POINT CAMPUS
WAPPINGERS FALLS, NY
JBS JDW
Path ID Common Path
Distance Allowable Common
Path Actual Travel
Distance Allowable Travel
Distance
A 0' - 0" 100' - 0" 131' - 6" 300' - 0"
B 0' - 0" 100' - 0" 209' - 1" 300' - 0"
COMMON 48' - 1" 100' - 0" 0' - 0" 300' - 0"
GENERAL SHEET NOTES
LIFE SAFETY LEGEND
EXIT ACCESS TRAVEL DISTANCE
1. PROVIDE EGRESS DOORS WITH CODE COMPLIANT EXIT DEVICES.
2. PROVIDE MINIMUM 1-FT CANDLE ILLUMINATION AT MEANS OF EGRESS
AND EXIT DISCHARGE WHEN BUILDING IS OCCUPIED.
3. KEEP EGRESS PATH FREE OF OBSTRUCTIONS.
4. PROVIDE FIRE EXTINGUISHERS AT LOCATIONS IN ACCORDANCE WITH
NFPA 10 PG18-3 AND AS DIRECTED BY LOCAL AUTHORITY.
5. LIFE SAFETY PLANS APPLY TO THE PROJECT SCOPE OF WORK ONLY
AND ARE PROVIDED FOR REFERENCE ONLY. INFORMATION IS BASED
ON OWNER PROVIDED DATA. CONTACT VAMC FOR ADDITIONAL LIFE
SAFETY INFORMATION OUTSIDE THE SCOPE OF WORK.
PROJECT SUMMARY:
THIS PROJECT CONSISTS OF AN ONCOLOGY RENOVATION OF THE SECOND FLOOR, BUILDING 15H, ROOMS 251A AND 250A-D . THIS PROJECT IS TO INCORPORATE INTERIOR PARTITIONS, FINISHES, MEDICAL EQUIPMENT, AND MEPFP SYSTEMS TO BRING THE EXISTING COMPOUNDING AREA INTO USP 800 COMPLIANCE. THE CONSTRUCTION SCOPE
INCLUDES COMPLIANCE WITH THE SUITE REQUIREMENTS AS FOLLOWS:
APPLICABLE CODES
VA HAS ADOPTED THE LATEST EDITION OF THE FOLLOWING CODES AND STANDARDS AS A MINIMUM FOR ALL PROJECTS PERFORMED IN THE MODERNIZATION, ALTERATION, ADDITION OR IMPROVEMENT OR ITS REAL PROPERTY AND THE CONSTRUCTION OF NEW STRUCTURES. VA DESIGN MANUALS AND MATER SPECIFICATIONS SPECIFY OTHER CODES AND STANDARDS THAT VA FOLLOWS ON ITS PROJECTS:
VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE IN
THE TECHNICAL INFORMATION LIBRARY (TIL)
NFPA 101 LIFE SAFETY CODE 2018 EDITION
VA FIRE PROTECTION DESIGN GUIDE 7TH EDITION
NFPA NATIONAL FIRE CODE (EXCEPTION OF NFPA 5000 AND NFPA 900)
USP 797
USP 800
VA SEISMIC DESIGN REQUIREMENTS, H-18-8
NATIONAL ELECTRICAL CODE (NEC)
INTERNATIONAL PLUMBING CODE (IPC)
ENERGY POLICY ACT OF 2005 (EPACT)
FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE BUILDINGS: MEMORANDUM OF UNDERSTANDING (MOU) EXECUTIVE ORDER 13423: STRENGTHENING FEDERAL ENVIRONMENTAL, ENERGY, AND TRANSPORTATION MANAGEMENT
THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGN
VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY - ASHRAE STANDARD 62.1 -2004
SAFETY STANDARD FOR REFRIGERATION SYSTEMS - ASHRAE STANDARD 15-2007
OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS
ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS)
TRAVEL DISTANCE AND COMMON PATH OF TRAVEL (38.2.5 & 38.2.6):
BUSINESS (CHAPTER 38): MAX TRAVEL DISTANCE MAX COMMON PATH OF TRAVEL MAX DEAD END CORRIDOR
SPRINKLED = 300' - 0" SPRINKLED = 100' - 0" SPRINKLED = 50' - 0"
INTERIOR WALLS :
• NONCOMBUSTIBLE PARTITIONS (4.6.13)
• LIMITED-COMBUSTIBLE PARTITIONS (4.6.14)
1. PARTITIONS CONSTRUCTED WITH FIRE-RETARDANT, TREATED WOOD ENCLOSED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE
MATERIALS
2. SUCH PARTITIONS SHALL NOT BE REQUIRED TO BE FIRE RATED
EXIT ACCESS:
• CORRIDOR EXIT ACCESS - MINIMUM OF (1) (38.2.4.3)
• CORRIDOR WIDTH - MINIMUM OF 44" (38.2.3.2)
HAZARDOUS CLASSIFICATION
THE CLASSIFICATION OF "HAZARDOUS" IN THE NFPA 100 DIFFERS FROM USP 800. ROOMS LABELED "HAZARDOUS" IN THE CONSTRUCTION DOCUMENTS REFER TO USP 800 REQUIREMENTS. "HAZARDOUS" REGARDING USP 800 RELATES TO THE TYPE OF DRUGS COMPOUNDED IN THE
PHARMACY AND NOT THE COMBUSTIBILITY OF THE MATERIALS IN THE PHARMACY.
PROJECT CODE SUMMARY
1/8" = 1'-0"F1 LIFE SAFETY PLAN
OCCUPANCY LEGEND
NO. DESCRIPTION DATE
B
A
C
D
E
F
1 2 3 4 5 6 87 9
97 8654321
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0116
B
A
C
D
E
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ENGINEER OF RECORDCONSULTANT PHARMACY USP 800 RENOVATION 620A4-18-212
15H
Project Director
2022-08-24
CASTLE POINT CAMPUS
WAPPINGERS FALLS, NY
STRUCTURAL
ABBREVIATIONS & NOTES
S-001
DSER
STOR
H-3
STOR
H-3
D
C
B
A
1 2 3 4 5 6 7
NO. DESCRIPTION DATE
B
A
C
D
E
F
1 2 3 4 5 6 87 9
97 8654321
PLAN
NORTH
ACTUAL
NORTH
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0116
B
A
C
D
E
F
KEYPLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ENGINEER OF RECORDCONSULTANT PHARMACY USP 800 RENOVATION 620A4-18-212
15H
Project Director
2022-08-24
CASTLE POINT CAMPUS
WAPPINGERS FALLS, NY
STRUCTURAL
ROOF PLAN
SF131
SGCER
S-501
STRUCTURAL
SECTIONS & DETAILS
ER RP
NO. DESCRIPTION DATE
B
A
C
D
E
F
1 2 3 4 5 6 87 9
97 8654321
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0116
B
A
C
D
E
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ENGINEER OF RECORDCONSULTANT PHARMACY USP 800 RENOVATION 620A4-18-212
15H
Project Director
2022-08-24
CASTLE POINT CAMPUS
WAPPINGERS FALLS, NY
EF
V
V V
V
V
HP
RC
HP
HP
HP
HP
HP
R .V
R .V
R .V
V
VTR
EF
EF
EF
EF
EF
EF
EF
HP
RO
OF
B
EL
OW
RD
RD
r 4
RD
r 5
ELEVATOR 01 ELEVATOR 02
STORAGE
H-300
E
LE
V
ATO
R
LO
BBY
C 3-
RD
r 5
EXISTING CONSTRUCTION TO BE
DEMOLISHED
EXISTING CONSTRUCTION TO
REMAIN
EXISTING DOOR TO REMAIN
EXISTING DOOR TO BE REMOVED
(DEMO)
EXISTING LIGHT TO BE SALVAGED
1. VERIFY EXISTING CONDITIONS PRIOR TO COMMENCING WORK.
DEMOLITION WORK HAS BEEN DERIVED FROM EXISTING DRAWINGS
AND ARE INTENDED TO REASONABLY REPRESENT CURRENT
CONDITIONS. ACTUAL CONDITIONS MAY VARY. NOTIFY COR IF
MATERIAL DISCREPANCIES ARE ENCOUNTERED.
2. SHADED AREAS ARE NOT IN CONTRACT EXCEPT AS NEEDED TO
PROVIDE SERVICES OR ACCESS FOR WORK.
3. COORDINATE WORK INDICATED WITH SPECIALTY DEMOLITION WORK
INDICATED IN OTHER CONSTRUCTION DOCUMENTS.
4. PROTECT EXISTING CONDITIONS INDICATED TO REMAIN FROM
DAMAGE OR DETERIORATION DUE TO PERFORMANCE OF WORK.
PATCH AND REPAIR EXISTING WORK IN MANNER TO ELIMINATE
EVIDENCE OF REPAIR WORK.
5. CEASE WORK, SECURE AREA AND NOTIFY COR IF POTENTIALLY
HAZARDOUS MATERIALS ARE ENCOUNTERED.
6. DO NOT CUT STRUCTURAL COMPONENTS UNLESS INDICATED
OTHERWISE.
7. COORDINATE REMOVAL OF DEMOLISHED MATERIALS WITH COR.
PREVENT DUST AND DEBRIS FROM INFILTRATING OCCUPIED AREAS.
PROVIDE ENCLOSED CHUTES AND NEGATIVE AIR PRESSURE AS
REQUIRED TO PREVENT CONTAMINATION. DISPOSE OF DEMOLISHED
MATERIALS IN LAWFUL MANNER, OFF SITE.
8. PROVIDE AND MAINTAIN TEMPORARY PARTITIONS, PROTECTIVE
BARRIERS AND SECURITY DEVICES AS REQUIRED TO PROTECT
BUILDING, CONTENTS AND OCCUPANTS FROM HARM DUE TO
DEMOLITION ACTIVITIES.
9. MATERIALS AND COMPONENTS TO BE SALVAGED ARE INDICATED.
REMOVE SALVAGE ITEMS AS COMPLETE UNITS TO THE EXTENT
POSSIBLE AND PROTECT FROM FURTHER DAMAGE. CLEAN
COMPONENTS OF DUST AND DIRT. STORE ON SITE AS DIRECTED BY
COR.
10. COORDINATE SCHEDULE WITH COR PRIOR TO COMMENCING
DEMOLITION WORK THAT MAY INTERRUPT SERVICES. SCHEDULE
WORK AND PROVIDE TEMPORARY CONNECTIONS OR NEW SERVICES
AS NECESSARY TO ELIMINATE DISRUPTIONS AFFECTING THE
OWNER'S OPERATIONS.
11. LOCATE AND MARK UTILITIES TO REMAIN WITH TAGS INDICATING
UTILITY TYPE. PROTECT UTILITIES FROM DAMAGE.
12. TO EXTENT POSSIBLE, DEMOLISH INDICATED ITEMS IN THEIR
ENTIRETY. REMOVE PARTITIONS TO DECK ABOVE. DEMOLISH
SERVICES SERVING EQUIPMENT AND UTILITIES TO THEIR SOURCE,
UNLESS INDICATED OTHERWISE.
13. DEMOLITION OF PARTITIONS INCLUDES WALL MOUNTED ITEMS,
ACCESSORIES AND SERVICES.
14. ACCESS FOR EXTERIOR CONSTRUCTION IS SHOWN FOR REFERENCE
ONLY AND DEMONSTRATING VAMC'S PREFERRED OPTION.
COORDINATE EXTERIOR ACCESS WITH COR.
B
A
2 3 4
EXST. OPEN OFFICE
251A
EXST. I.V. ROOM B
250D
EXST. ANTE ROOM
250A
EXST. I.V. ROOM A
250C
EXIST. FREEZER AND
SUPPLIES
250B
001 001
3' - 4"3' - 6"3' - 2"11"2' - 5"5' - 7"
019 019 019
019 018 019
X-CPT
X-EPY
X-EPY
X-EPY
X-EPY
AREA OF CONSTRUCTION
026026 025
3' - 4" 2' - 8"
B
A
2 3 4
EXST. OPEN OFFICE
251A
EXST. I.V. ROOM B
250D
EXST. ANTE ROOM
250A
EXST. I.V. ROOM A
250B
EXIST. FREEZER AND
SUPPLIES
250C
013 013
013 013 013
013 013
X-ACT
8' - 6"A.F.F.
X-ACT
8' - 6"A.F.F.
X-ACT
8' - 6"A.F.F. X-ACT
8' - 6"A.F.F.
X-ACT
8' - 3"A.F.F.
AREA OF CONSTRUCTION
1234567
LEVEL 3
30' - 0"
LEVEL 1
10' - 0"
LEVEL 2
20' - 0"
BASEMENT FLOOR
(GROUND FLOOR)
2' - 0"
025 002
D
C
B
A
3 4 5 6 7 N 9
Q R
T
C.1
D.1
032032032032
032032032
DEMOLITION SHEET NOTES
LEGEND
# NOTE
001 DEMO FLOORING AND WALL BASE. PREP SUBFLOOR TO RECEIVE NEW FLOOR FINISH. LEVEL
FLOOR AS REQUIRED.
002 DEMO GLAZING PANEL AND PREPARE OPENING TO RECEIVE NEW SPANDREL PANEL.
004 DEMO CEILING TILE, CEILING GRID, SUSPENSION SYSTEM AND CEILING COMPONENTS IN ITS
ENTIRETY. REFER TO MEP/FP DRAWINGS FOR ADDITIONAL INFORMATION.
005 REMOVE EXISTING PLUMBING FIXTURE(S) IN THEIR ENTIRETY. REFER TO DRAWING P-121 FOR
ADDITIONAL INFORMATION.
006 DEMO DOOR FRAME AND HARDWARE. INFILL OPENING WITH CONSTRUCTION TO MATCH
EXISTING WALL CONSTRUCTION. PREP WALLS TO RECEIVE FINISH INDICATED.
007 DEMO PARTITION. PATCH AND REPAIR ADJACENT SURFACES TO REMAIN IN MANNER TO
ELIMINATE EVIDENCE OF REPAIR.
013 SALVAGE LIGHT FIXTURES. CLEAN FIXTURES THEN WRAP PACKAGE AND MARK CONTAINER
WITH CONTENTS. STORE ON SITE AS DIRECTED BY COR.
014 DEMO SINK.
018 DEMO PORTION OF EXISTING PARTITION AS REQUIRED TO ACCOMODATE NEW DOOR AND
FRAME. PATCH AND REPAIR ADJACENT CONSTRUCTION AS REQUIRED TO ELIMINATE
EVIDENCE OF REPAIR. PREP WALLS TO RECEIVE NEW WALL FINISH.
019 PATCH AND PREP WALLS AS REQUIRED TO RECEIVE NEW FINISHES.
025 DEMOLITION OF WINDOW SHOWN AS PREFERRED LOCATION FOR DEMOLITION MATERIAL
WASTE CHUTE. COORDINATE REQUIREMENTS WITH COR. IF USED, PREP OPENING FOR NEW
INFILL.
026 DEMO WINDOW TRIM. PREP AREA FOR INFILL.
027 DEMOLISH EXISTING CEILING MOUNTED EXIT SIGNS
028 DEMO DOOR, FRAME AND HARDWARE.
029 INFILL EXISTING OPENING TO MATCH ADJACENT CONSTRUCTION. PREP WALLS TO RECEIVE
NEW WALL FINISHES.
030 EXISTING ROOF EXHAUST FAN TO REMAIN
031 EXISTING ROOF EXHAUST FAN TO BE DEMOLISHED AND EXISTING CURB TO BE CAPPED.
032 EXISTING PLUMBING VENT TO BE DMEOLISHED; PATCH AND REPAIR ROOF TO MEET ROOF
MANUFACTURER'S WARRANTY, REQUIREMENTS AND STANDARDS.
KEYNOTES
A S e rv ic e
D i s a b le d
Ve t e r an Owned S m a l l B u s iness
SDVOSB
CVE
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0116
Drawing Title
Approved: Project Director
Project Title
Issue Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANT Office of o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t 6 o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
NO. DESCRIPTION DATE
PLAN
NORTH
PHARMACY USP 800 RENOVATION 620A4-18-212
15H
U.S. Department of Veterans Affairs
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
ACTUAL
NORTH
Phase
BID DOCUMENTS
FULLY SPRINKLERED
Construction and Facilities Management
ENGINEER OF RECORD DEMOLITION SECOND FLOOR PLAN
,ELEVATION & ROOF PLAN
AD-100
2022-08-24
CASTLE POINT CAMPUS
WAPPINGERS FALLS, NY
JBS JTK
1/4" = 1'-0"B1 COMPOUNDING SUITE DEMO PLAN
1/4" = 1'-0"B4 COMPOUNDING SUITED DEMO RCP
AREA OF DEMOLITION
1/8" = 1'-0"E1 PARTAIL DEMOLITION NORTH ELEVATION
1" = 10'-0"F1 ENLARGED DEMOLITION ROOF PLAN
ROOF PROTECTION NOTES
1. PROTECT EXISTING ROOFING FROM DAMAGE OR DETERIORATION
DURING PERFORMANCE OF THE WORK.
2. PROVIDE BARRIERS AS REQUIRED TO PREVENT TRAFFIC ON ROOFING.
IF ROOF MUST BE ACCESSED, PROVIDE PROTECTIVE COVERING
SUFFICIENT TO PREVENT PUNCTURES, WEAR AND OTHER DAMAGE TO
ROOFING.
3. PERFORM NO WORK ON ROOFING THAT MAY JEOPARDIZE OR VOID
EXISTING WARRANTIES.
4. REPAIR OR REPLACE ROOFING DAMAGED BY PERFORMANCE OF THE
WORK. PROVIDE ANY REPAIRS OF REPLACEMENTS IN MANNER TO
PROTECT EXISTING WARRANTIES.
5. USE MATERIALS, METHODS AND SYSTEMS TO MATCH EXISTING AND AS
APPROVED BY ORIGINAL ROOFING MANUFACTURER.
D
C
B
A
3 4 5 6
M
N 9
Q
R
T
23222119
A-100
C6
299 SF
EDUCATION
OFFICE
H-047A
143 SF
OFFICE
H-048
1034 SF
EMPLOYEE
FITNESS AND
WELLNESS
CENTER
H-047
478 SF
PT OFFICE
H-046J
142 SF
KT OFFICE
H-046E
403 SF
OT OFFICES
H-046D
59 SF
OFFICE
H-046C
160 SF
PT STORAGE
H-046D1
64 SF
TOILET
H-046B
111 SF
CHIEF OFFICE
046I
58 SF
LEAD OFFICE
046H
3295 SF
PHYSICAL
THERAPY CLINIC
H-046
147 SF
AGENT CASHIER
H-042
123 SF
TRAVEL CLERK
H-041
55 SF
VACANT TOILET
H-045
78 SF
TOILET
H-043
13 SF
TELE. CL.
H-044
1003 SF
CORRIDOR
CB-02
591 SF
TRAVEL ROOM
H022
253 SF
MULTI-PURPOSE
ROOM
H022A
46 SF
TOILET
H-046A
222 SF
ELECTRICAL
ROOM
H-051A
88 SF
ELECTRICAL
ROOM
H-051
133 SF
OFFICE
H-052
148 SF
ELEVATOR MECH.
ROOM
H-053
473 SF
ELEVATOR
LOBBY
CB-01
95 SF
ELEVATOR
87 SF
ELEVATOR
81 SF
STOR.
H-001
101 SF
DATA-TELE
H-049
46 SF
E.M.S. CLOSET
H-050
ELECTRICAL
ROOM
H-051A
OFFICE
H-052
ELECTRICAL
ROOM
H-051
E.M.S. CLOSET
H-050
DATA-TELE
H-049
PROJECT LIMIT LINE
D
C
B
A
3 4 5 6 7
N 9
Q
R
T
2221194.1
275 SF
2 BEDROOM
H-125
273 SF
2 BEDROOM
H-126
70 SF
BATHROOM
H-126A
41 SF
W/C STORAGE
H-127
360 SF
2 BEDROOM
H-128
25 SF
TOILET
H-128A
1158 SF
DAYROOM
H-129
361 SF
2 BEDROOM
H-130
26 SF
TOILET
H-130A
44 SF
W/C STORAGE
H-131
274 SF
2 BEDROOM
H-132
71 SF
BATHROOM
H-132A
275 SF
2 BEDROOM
H-133
70 SF
BATHROOM
H-133A
25 SF
STORAGE
H-134
298 SF
2 BEDROOM
H-135
323 SF
2 BEDROOM
H-136
70 SF
BATHROOM
H-136A
70 SF
BATHROOM
H-135A
532 SF
4 BEDROOM
H-138
37 SF
TOILET
H-138A
69 SF
ELECTRICAL
H-137 114 SF
DATA CLOSET
H-139
276 SF
LOUNGE
H-100
408 SF
CORRIDOR
C1-02
209 SF
ELEVATOR
LOBBY
C1-01
95 SF
CLEAN LINEN
H-101
695 SF
MECH. EQUIP.
ROOM
H-103
102 SF
EQUIP. STORAGE
H-102
30 SF
E.M.S CLOSET
H-141
99 SF
SOILED UTILITY
H-104
119 SF
OFFICE
H-106
144 SF
EXAM ROOM
H-106A
55 SF
NUTRITION ROOM
H-110
67 SF
MED. ROOM
H-112
199 SF
STAIR HALL
NO. 01
145 SF
CORRIDOR
C1-04
712 SF
CORRIDOR
C1-07
629 SF
CORRIDOR
C1-06
A-100
F6
4 BEDROOM
H-138
DATA CLOSET
H-139
TOILET
H-138A
ELECTRICAL
H-137
BATHROOM
H-136A
2 BEDROOM
H-136
CORRIDOR
C1-02
PROJECT LIMIT LINE
A S e rv ic e
D i s a b le d
Ve t e r an Owned S m a l l B u s iness
SDVOSB
CVE
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0116
Drawing Title
Approved: Project Director
Project Title
Issue Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANT Office of o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t 6 o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
NO. DESCRIPTION DATE
PLAN
NORTH
PHARMACY USP 800 RENOVATION 620A4-18-212
15H
U.S. Department of Veterans Affairs
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
ACTUAL
NORTH
Phase
BID DOCUMENTS
FULLY SPRINKLERED
Construction and Facilities Management
ENGINEER OF RECORD BASEMENT AND FIRST FLOOR PLANS
A-100 2022-08-24
CASTLE POINT CAMPUS
WAPPINGERS FALLS, NY
JBS JDW
1/8" = 1'-0"C1 PARTIAL BASEMENT FLOOR PLAN (GROUND FLOOR)
1/4" = 1'-0"C6 ENLARGED ELECTRICAL/DATA ROOM PLAN
SHEET NOTES
1/8" = 1'-0"F1 PARTIAL FIRST FLOOR PLAN
1/4" = 1'-0"F6 ENLARGED ELECTRICAL/DATA ROOM PLAN
1. SHADED AREAS ARE NIC, EXCEPT AS NEEDED TO PROVIDE SERVICES FOR
WORK.
2. ALL DIMENSIONS ARE TO FACE OF STUD OR BLOCK FACE.
3. WHERE INDICATED TO MATCH EXISTING FINISH, NEW FINISH TO MATCH IN
MANUFACTURER, PRODUCT, COLOR, STYLE, SIZE AND ALL OTHER
ATTRIBUTES.
4. ALL DIMENSIONS ARE TO FINISHED FACE OF WALL OR GRIDLINE. DO NOT
SCALE DRAWINGS.
5. PROTECT EXISTING SURFACES AND MATERIALS INDICATED TO REMAIN FROM
DAMAGE OR DETERIORATION DUE TO PERFORMANCE OF WORK. PATCH AND
REPAIR EXISTING MATERIALS AND SURFACES DAMAGES OR AFFECTED BY
PERFORMANCE OF THE WORK.
6. WORK INCLUDES PREPARATION OF EXISTING SURFACES TO RECEIVE NEW
WORK WHERE INDICATED.
7. ALL ANGLES ARE 90 DEGREES UNLESS NOTED OTHERWISE.
8. COORDINATE FIRE EXTINGUISHER, FIRE ALARM STROBES AND PULL STATION
LOCATIONS WITH COR. MOUNT IN ACCORDANCE WITH FEDERAL ABA
STANDARDS.
9. VERIFY DIMENSIONS AND LOCATIONS OF OPENINGS, BASES AND SUPPORTS
FOR EQUIPMENTS, DUCTS, PIPING , CONDUITS, ETC. WHERE REQUIRED FOR
NEW WORK, NEATLY CUT OPENINGS IN EXISTING CONSTRUCTION USING
POWER SAWS OR CORE DRILLS. DO NOT USE IMPACT TOOLS. REVIEW
OPENING LOCATIONS WITH COR PRIOR TO STARTING WORK. KEEP
OPENINGS TO MINIMUM REQUIRED TO ALLOW FOR NEW WORK. PROVIDE
FIRE STOPPING AS REQUIRED.
10. OBTAIN BURN PERMIT FROM COR PRIOR TO PERFORMING ANY WORK
REQUIRING OPEN FLAME.
11. PROVED FIRE RETARDANT TREATED WOOD FOR BLOCKING AND ROUGH
BUCKS. COORDINATE LOCATIONS WITH EQUIPMENT INSTALLER. INSTALL
PRIOR TO CLOSING WALLS.
12. EXAMINE EXISTING SUBSTRATES TO RECEIVE NEW MATERIAL OR FINISH.
PREPARE SUBSTRATE AS REQUIRED TO MEET MANUFACTURER'S
INSTRUCTIONS OR RECOMMENDATIONS FOR PROPER APPLICATION OF NEW
MATERIALS.
13. WHERE FLOOR FINISHES CHANGE AT COMMUNICATING ROOMS, PLACE
TRANSITION UNDER CENTER OF DOOR OR FINISHED OPENING.
14. PROVIDE SMOKE-TIGHT, NON-COMBUSTIBLE 1-HR RATED TEMPORARY
PARTITIONS TO DECK WHERE REQUIRED TO SEPARATE AREAS WHERE
WORK IS BEING PERFORMED FROM OTHER SPACES.
15. IF ANY FIRE RATED PARTITION FALLS DIRECTLY BENEATH AND PARALLEL TO
A FLOOR JOIST OR BEAM, NOTIFY THE ARCHITECT PRIOR TO FRAMING THE
PARTITION.
16. VERIFY THAT ALL BUILDING CORE PARTITIONS AND COLUMNS SHOWN AS
EXISTING CONSTRUCTION ARE READY TO RECEIVE NEW FINISHES AS
SPECIFIED. IF NOT, PROVIDE DRYWALL FINISH AS REQUIRED. DRYWALL
THICKNESS TO MATCH BUILDING STANDARD NOTED ON PARTITION TYPES. AT
ALL EXISTING GYPSUM BOARD CORNERS, VERIFY THAT ALL CORNER BEADS
ARE STRAIGHT, UNBROKEN AND NOT DAMAGED. PROVIDE NEW CORNER
BEADS AS REQUIRED.
KEYNOTES
# NOTE
149 EXISTING CEILING TILES TO BE REMOVED AND PROTECTED DURING
CONSTRUCTION. TILES TO BE REINSTALLED WHEN CONSTRUCTION IS COMPLETED.
NEW PARTITION
EXISTING PARTITION TO REMAIN
RATED PARTITION
EXISTING DOOR
NEW CONSTRUCTION
DOOR
NEW CONSTRUCTION
SLIDING DOOR
B
A
2 3
PPE
TR
ST
PPE
INT
TR
SAN
LP
IV
S
H
SH1
REF
NHD
SHOE
IVSH
SAN
DISP
SAN
INT
CH1
A-200
B2
A-200
A1
A-200 D1
A-200
C3
E2
E1
D2 B4
B1B5
A2
C1
C2
AREA OF CONSTRUCTION
PASS
B
-A
-A
B
-A
250A-A
140 SF
NEG. ANTE
250C-B144 SF
NEG. BUFFER
250D
103 SF
POS. BUFFER
250A
186 SF
POS. ANTE
44 SF
RECEIVING /
BREAK DOWN
249B
C7
A-200
WS
A-200
A6
A5
A3
INT
INT
IN
TR
ST
D E
M A
R K
LH
D E
M A
R K
C
-B
49 SF
AIRLOCK
250C
HW/EW
HW/EW
SHOE
FEC
SH1
PIVPIV
DS
FILE
WKT1
SOAP
PT
PT
SOAP
SS500
A-200
C5
ST
TR
PH
STO
WKT1
WKT2
REF
WKT4
NOTE: ITEMS/TAGS SHOWN IN GREY REPRESENT VA FURNISHED/INSTALLED EQUIPMENT AND ARE FOR REFERENCE ONLY
SAN
SAN
WKT2
/4
9'
1"
CS600
CS500
WKT3
STO
A-200
D3
A-200 D3
COM
LH
DSDS
DS
DSDS
DS
DS
250C-A
B
A
2 3 4
NEG. BUFFER
250D
NEG. ANTE
250C-B
POS. BUFFER
250A
POS. ANTE
RECEIVING /
BREAK DOWN
249B
EQ.7' - 0"EQ
AIRLOCK
250C
EQEQ
AREA OF CONSTRUCTION
E Q
4'
0" E
Q
2' - 0" 2' - 0"
2'
1/
4" 2'
0"
EQ4' - 0"EQE
Q
E Q
EQ 4' - 0" 4' - 0" EQ
2'
0" 4'
6"
1' - 8"1' - 6"1' - 6"1' - 8"
E Q
1'
6" 1'
6"
E Q
GYP. CLG.
9' - 0"A.F.F.
GYP. CLG.
9' - 0"A.F.F.
GYP. CLG.
9' - 0"A.F.F.
GYP. CLG.
9' - 0"A.F.F.
GYP. CLG.
9' - 0"A.F.F.
GYP. CLG.
9' - 0"A.F.F.
B
A
2 3 4
16' - 1"
35' - 9 1/4"
37' - 2"
2' - 8"3' - 4" R.O.
4"
4' - 10 1/4"3' - 4" R.O.3' - 8 3/4"3' - 4" INFILL3' - 6"3' - 2" INFILL8' - 11"
-A
NEG. BUFFER
250D
NEG. ANTE
250C-B
POS. ANTE
POS. BUFFER
250A RECEIVING /
BREAK DOWN
249B
250A-A
B
-A
B
-A
EPY-1
EPY-1
EPY-1
EPY-1
EPY-1
A 1 a
A 2 a
A 1 a
A 2 a A 1 a
B 1 a B 1 a
7' - 6 1/4"
MASONRY INFILL
3' - 10"
3'
1/
2" 9'
1"
AREA OF CONSTRUCTION
132 132
C7
A-200
AIRLOCK
250C
IN
EPY-1
D E
M A
R K
D E
M A
R K
C
-BC L
ALIGN
10' - 3 1/4" 19' - 4 1/4"
9'
1"
/4
9'
3/
4"
6'
/2
/2
1/
4"
1' - 3" C L
CLEAR
3' - 2"
5' - 11"CL
10' - 5" 1' - 4 1/4"
B 5 a B 5 a
5' - 5" 13' - 1"
6' - 4"6' - 9"
E7
A-200
A 1 a
CL
3' - 6"
4'
144144
144 144144
4'
250C-A
FEC
150 150
NOT TO SCALE. ARCHITECTURAL INFORMATION SHOWN FOR REFERENCE ONLY. MEP/HVAC DRAWINGS
SHALL GOVERN.
WALL MOUNTED EXIT
SIGN
RECESSED TROFFER
(1x4,2X2, 2X4, ETC)
SEE ELECTRICAL
RETURN AIR
RECESSED CAN
ACOUSTICAL
CEILING AND GRID
MS MOTION SENSOR
SUPPLY AIR
LINEAR DIFFUSER
EXHAUST FAN
GYPSUM BOARD CEILING
12" X 12" ACCESS PANEL
PROJECT LOCATION
5/8" GYPSUM
BOARD
ACCESS PANEL
ATTACH PER MFR
RECOMMENDATIONS
1" x 1-9/16" x 1"
KNURLED CHANNEL
MOLDING
MAX.
0' - 3"
CROSS TEE
SHEET NOTES
PLAN LEGENDKEYNOTES
# NOTE
128 RES-3, 6" FLOORING STRIPE ON FLOOR TO INDICATE PHARMACY DEMARK LINE. DEMARK LINE TO BE CONTRASTING COLOR FROM EXISTING FLOOR. COORDINATE FINAL LOCATION, COLOR AND/OR MARKINGS WITH PHARMACY DIRECTOR.
129 PROVIDE SPANDREL PANEL. COLOR TO MATCH BUILDING STANDARD.
132 WALL INFILL TO MATCH EXISTING CONSTRUCTION.
141 VA TO PROVIDE USP COMPLIANT HAZARDOUS DRUG HANDLING SIGNAGE IN THIS ROOM
142 VA TO PROVIDE SPILL KIT FOR RECEIVING AND BREAKDOWN ROOM
143 NEW MASONRY INFILL TO MATCH ADJACENT EXTERIOR CONSTRUCTION. SEE C8/A-200.
144 MECHANICAL RETURN GRILLE; REF. MECHANICAL DRAWINGS MH121 & M702 FOR ADDITIONAL INFORMATION AND SIZING.
150 ROOM IDENTIFICATION SIGNAGE LOCATION. CONFIRM FINAL COPY WITH COR. REFERENCE A501 FOR SIGNAGE SCHEDULE.
1/4" = 1'-0"E1 COMPOUNDING SUITE EQUIPMENT PLAN
1/4" = 1'-0"C4 COMPOUNDING SUITE NEW WORK RCP
1/4" = 1'-0"C1 COMPOUNDING SUITE NEW WORK PLAN
RCP LEGEND
A S e rv ic e
D i s a b le d
Ve t e r an Owned S m a l l B u s iness
SDVOSB
CVE
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0116
Drawing Title
Approved: Project Director
Project Title
Issue Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANT Office of o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t 6 o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
NO. DESCRIPTION DATE
PLAN
NORTH
PHARMACY USP 800 RENOVATION 620A4-18-212
15H
U.S. Department of Veterans Affairs
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
ACTUAL
NORTH
Phase
BID DOCUMENTS
FULLY SPRINKLERED
Construction and Facilities Management
ENGINEER OF RECORD COMPOUNDING SUITE NEW WORK PLANS
A-101 2022-08-24
CASTLE POINT CAMPUS
WAPPINGERS FALLS, NY
JBS JDW
QTY
TYPE
MARK DESCRIPTION PRODUCT #
FURNISH
ED BY
INSTALLED
BY REMARK
1 CH1 CHAIR ON CASTERS WITH CUSHIONED BACK N/A VA VA
1 COM COMPUTER, REQUIRES POWER AND DATA N/A VA VA
1 CS500 CLASS II BIOLOGICAL SAFETY CABINET WITH
TOUCHSCREEN MONITOR, DUAL POWER OUTLETS, AND
CLOSED CONTAINMENT SYSTEM FOR HAZARDOUS WASTE.
CS500 VA CON. COORDINATE WITH CORE AND PHARMACY
1 CS600 CLASS II BIOLOGICAL SAFETY CABINET WITH
TOUCHSCREEN MONITOR, DUAL POWER OUTLETS, AND
CLOSED CONTAINMENT SYSTEM FOR HAZARDOUS WASTE.
CS600 VA CON. COORDINATE WITH CORE AND PHARMACY
1 DISP WALL MOUNT MASK, BEARD, HAIR COVER DISPENSER. N/A VA VA
8 DS WALL MOUNTED DOOR SENSOR - HAND WAVED N/A CON. CON.
1 FE SURFACE MOUNTED FIRE EXTINGUISHER N/A CON. CON. LOCATED IN ROOFTOP AHU. SEE MECH. DRAWINGS
FOR ADDITIONAL INFORMATION
1 FEC FULLY RECESSED FIRE EXTINGUISHER CABINET N/A CON. CON.
1 FILE FILE CABINET N/A VA VA
2 HW/EW HAND WASHING SINK WITH EYE WASH - STAINLESS STEEL JPH-ADA-22
24-CT
CON. CON. PLUMBING CONNECTION REQUIRED.
4 INT INTERCOM, HANDS FREE N/A VA CON.
2 IVSH IV SUPPLY STORAGE WIRE SHELVING UNIT ON CASTORS. N/A VA VA
2 LH LADDER HANGER, STAINLESS STEEL N/A VA VA COORDINATE FINAL LOCATION IN THE FIELD WITH
COR.
1 LP IV LABEL MAKER 105SL VA VA
1 NHD WIRE SHELVING UNIT N/A VA VA
1 PASS WALL MOUNTED PASS-THROUGH WINDOW. CAP25WX2
4HX25XD
CON. CON. BASIS OF DESIGN - CLEAN AIR CAP18WHF-SST.
WITH HEPA FILTRATION.
1 PH TELEPHONE N/A VA VA
2 PIV ELECTRONIC CARD READER N/A CON. CON.
2 PPE WIRE RACK ON CASTORS WITH PLASTIC BINS FOR
SUPPLIES
N/A VA VA
2 PT AUTOMATIC PAPER TOWEL DISPENCER, WALL MOUNTED N/A VA CON.
2 REF SINGLE GLASS DOOR MEDICAL GRADE REFRIGERATOR FOR
HD STORAGE.
00926378 VA VA 29.75" W x 35" D x 79.5" H
5 SAN AUTOMATIC HAND SANITIZER DISPENSER N/A VA CON.
2 SH1 WIRE SHELVING, STAINLESS STEEL N/A VA VA
2 SHOE AUTOMATIC SHOE COVER DISPENSER N/A VA VA 12.5" W x 27" D x 8.5" H
2 SOAP AUTOMATIC SOAP DISPENSER, WALL MOUNTED N/A VA CON.
1 SS500 STERILSHIELD 500 BIOLOGICAL SAFETY CABINET WITH
TOUCHSCREEN
SS500 VA CON. COORDINATE WITH CORE AND PHARMACY
5 ST STAINLESS STEEL WORK STOOL WITH FOOTREST N/A VA VA
2 STO MOBILE STORAGE CART N/A VA VA
5 TR HAZARDOUS WASTE RECEPTACLE FOR CONTAMINATED
GARB MATERIALS, STAINLESS STEEL
N/A VA VA
3 WKT1 7' STAINLESS STEEL WORKTABLE N/A VA VA
2 WKT2 6' STAINLESS STEEL WORKTABLE N/A VA VA
1 WKT3 5' STAINLESS STEEL WORKTABLE N/A VA VA
1 WKT4 2'-6" STAINLESS STEEL WORKTABLE N/A VA VA
1 WS STAINLESS STEEL STORAGE CABINET WITH GLASS DOORS
AND SHELVES
N/A VA VA
EQUIPMENT SCHEDULE
1. TO THE GREATEST EXTENTS POSSIBLE, PHARMACY BUFFER AND
COMPOUNDING ROOMS MUST HAVE SMOOTH SURFACES TO PROVIDE FOR
PROPER AND THOROUGH CLEANING. TO THE GREATEST EXTENTS
POSSIBLE, ELIMINATE UNNECESSARY JOINTS AND GAPS IN THE
CONSTRUCTION MATERIALS.
2. SEE SHEET A-500 FOR PARTITION TYPES AND DOOR SCHEDULE.
FINISH SCHEDULE
Number RM NAME
FLOOR
FINISH
BASE
FINISH
WALL FINISH CEILING
FINISH COMMENTSNORTH EAST WEST SOUTH
249B RECEIVING / BREAK
DOWN
RES-3 RES-3 P-1 P-1 P-1 P-1 P-1
250 POS. ANTE RES-3 RES-3 P-1 P-1 P-1 P-1 P-1
250A POS. BUFFER RES-3 RES-3 P-1 P-1 P-1 P-1 P-1
250C AIRLOCK RES-3 RES-3 P-1 P-1 P-1 P-1 P-1
250C-B NEG. ANTE RES-3 RES-3 P-1 P-1 P-1 P-1 P-1
250D NEG. BUFFER RES-3 RES-3 P-1 P-1 P-1 P-1 P-1
P-1 RESINOUS SPECIALTY GLAZED
COATING SYSTEMS FOR WALLS,
CEILINGS, WALLBOARD, AND BLOCK
CMU
RES-3 EPOXY FLOORING
RESINOUS (WITH INTEGRAL COVE
BASE) HIGH PERFORMANCE
DECORATIVE MORTAR FLOORING.
SS-1 STAINLESS STEEL
INTERIOR FINISH NOTES
REFLECTED CEILING NOTES
1. WHERE COLOR IS SHOWN AS BEING SPECIFIC TO ONE MANUFACTURER, AN EQUIVALENT COLOR BY
ANOTHER MANUFACTURER MAY BE SUBMITTED FOR APPROVAL. MANUFACTURERS AND MATERIALS
SPECIFIED ARE NOT INTENDED TO LIMIT THE SELECTION OF EQUAL COLORS FROM OTHER MANUFACTURERS.
THE WORD "COLOR" AS USED HEREIN INCLUDES SURFACE COLOR PATTERN.
2. ALL DOOR FRAMES AND METAL DOORS ARE TO BE PAINTED PTC1.
3. ALL VENTS AND ACCESS PANELS TO BE PAINTED TO MATCH ADJACENT SURFACE WITH ALKYD ENAMEL
PAINT.
4. ALL FLOORING TO BE INSTALLED FLUSH WITH ADJACENT FLOORING FINISH, UNLESS NOTED OTHERWISE.
5. WHERE FLOOR FINISHES CHANGE AT COMMUNICATING ROOMS, PLACE TRANSITION UNDER CENTER OF
DOOR OR FINISHED OPENING.
6. DEMARK LINE TO BE CONTRASTING COLOR TO ADJACENT RESINOUS FLOORING COLOR. COLOR TO BE HIGH
VISIBILITY YELLOW.
1. SEE SPECIALTY DOCUMENTS FOR WORK AFFECTING CEILINGS.
2. COORDINATE SEQUENCE OF SPECIALTY WORK TO ENSURE ORDERLY
INSTALLATION. ALLOW FOR CEILING HANGERS AND ADEQUATE ACCESS TO
VALVES, TURNING VANES, JUNCTION BOXES AND SIMILAR ITEMS THAT MAY
REQUIRE ADJUSTMENT OR SERVICE. INSTALL ABOVE CEILING HEIGHTS
INDICATED.
3. INDEPENDENTLY SUPPORT CEILING MOUNTED EQUIPMENT AND LOCATE
CENTERED ON CEILING TILE. PROVIDE TRIM OR ESCUTCHEONS AROUND
TILE PENETRATIONS.
4. EXCEPT AS INDICATED OTHERWISE, LOCATE SOFFITS AND BULKHEADS 2"
BELOW ADJOINING ACOUSTICAL CEILING.
5. SEE SHEET A-500 FOR CEILING DETAILS.
6. ALL CEILINGS TO BE CLG-1 @ 9'-0" AFF UNLESS NOTED OTHERWISE.
7. "EQ" DIMENSIONS INDICATE EQUAL DIMENSIONS ON A CONTINUOUS
DIMENSION STRINGER AND ARE NOT INTENDED TO REPRESENT EQUAL
DIMENSIONS ACROSS DISCONTINUOUS DIMENSION STRINGERS.
ACCESS PANEL DETAIL
6" = 1'-0"C7 ACCESS PANEL DETAIL
(N)VTR
(N)VTR
(N)VTR
HP HP
HP
HP
HP
H P
H P
RC
HP
HP
HP
HP
HP
R .V
R .V
R .V
R .V
R .V
R .V
R .V
R .V
R .V
R .V
R .V
R .V
V
V V
V V
V
V
VT
R VT
R
VT
R
V
V
V
V
V
EF
EF
EF
EF
EF
EF
E F
EF
EF
EF
EF
EF
EF
EF
EF
ECEC
ECEC
SF
PP
PP
HP
RO
OF
B
ELO
W
RD
R D
RD
RD
r 4
RD
r 5
ELEVATOR 01 ELEVATOR 02
STORAGE
H-300
ELE
VATO
R
LO
BBY
C 3-
RD
r 5
D
D
1.7
GPM
HP HP
HP
HP
HP
H P
H P
RC
HP
HP
HP
HP
HP
R .V
R .V
R .V
R .V
R .V
R .V
R .V
R .V
R .V
R .V
R .V
R .V
V
V V
V V
V
V
VT
R VT
R
VT
R
V
V
V
V
V
EF
EF
EF
EF
EF
EF
E F
EF
EF
EF
EF
EF
EF
EF
EF
ECEC
ECEC
SF
PP
PP
HP
RO
OF
B
ELO
W
RD
R D
RD
RD
r 4
RD
r 5
ELEVATOR 01 ELEVATOR 02
STORAGE
H-300
ELE
VATO
R
LO
BBY
C 3-
RD
r 5
K
J
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7
N 9
Q R
T
C.1
D.1
4.13.12.1S
FE
PROJECT LOCATION
A S e rv ic e
D i s a b le d
Ve t e r an Owned S m a l l B u s iness
SDVOSB
CVE
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0116
Drawing Title
Approved: Project Director
Project Title
Issue Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANT Office of o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t 6 o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
NO. DESCRIPTION DATE
PLAN
NORTH
PHARMACY USP 800 RENOVATION 620A4-18-212
15H
U.S. Department of Veterans Affairs
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
ACTUAL
NORTH
Phase
BID DOCUMENTS
FULLY SPRINKLERED
Construction and Facilities Management
ENGINEER OF RECORD ROOF PLAN
A-102 2022-08-24
CASTLE POINT CAMPUS
WAPPINGERS FALLS, NY
JBS JTK
1/8" = 1'-0"F2 ROOF PLAN
1. PERFORM ROOF WORK IN MANNER TO MAINTAIN ANY ROOF WARRANTIES
THAT MAY STILL BE IN EFFECT. COORDINATE WITH COR.
2. PATCH AND REPAIR ROOF MEMBRANE AND SUBSTRATE DAMAGED BY
PERFORMANCE OF WORK INDICATED.
3. PROVIDE FIRESTOPPING AT PENETRATIONS AS REQUIRED TO MAINTAIN
RATED ROOF ASSEMBLY.
4. LEAVE ROOF IN WATERTIGHT CONDITION AT THE END OF EACH WORKDAY.
5. EXCEPT AS INDICATED OTHERWISE, INSTALL NEW FLASHINGS TO MINIMUM
8" ABOVE ROOF LEVEL.
SHEET NOTES
KEYNOTES
# NOTE
140 NEW MECHANICAL ROOF EQUIPMENT; REF: MECHANICAL DRAWING M-131 FOR
ADDITIONAL INFORMATION
145 SOLID EQUIPMENT COVER; REF. MECHANICAL FOR ADDITIONAL INFORMATION
146 NEW ROOF WALKWAY PADS TO MECHANICAL ACCESS AREAS; REF. MECHANICAL
SHEET M131 FOR ADDITIONAL INFORMATION.
147 NEW 42" RAILING BY GC
148 PROVIDE NEW SURFACE MOUNTED FIRE EXTINGUISHER CABINET INSIDE NEW
ROOFTOP AHU. REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION.
151 ROOF ACCESS SIGNAGE TO BE LOCATED ON THE INTERIOR SIDE OF ROOF ACCESS
DOOR LEAVING ELEVATOR LOBBY C3-01 AND READ, "NO ROOF ACCESS WITHOUT
PRIOR NOTIFICATION TO PHARMACY." FINAL LOCATION DETERMINED BY V.A.
ROOF PROTECTION NOTES
1. PROTECT EXISTING ROOFING FROM DAMAGE OR DETERIORATION
DURING PERFORMANCE OF THE WORK.
2. PROVIDE BARRIERS AS REQUIRED TO PREVENT TRAFFIC ON ROOFING.
IF ROOF MUST BE ACCESSED, PROVIDE PROTECTIVE COVERING
SUFFICIENT TO PREVENT PUNCTURES, WEAR AND OTHER DAMAGE TO
ROOFING.
3. PERFORM NO WORK ON ROOFING THAT MAY JEOPARDIZE OR VOID
EXISTING WARRANTIES.
4. REPAIR OR REPLACE ROOFING DAMAGED BY PERFORMANCE OF THE
WORK. PROVIDE ANY REPAIRS OF REPLACEMENTS IN MANNER TO
PROTECT EXISTING WARRANTIES.
5. USE MATERIALS, METHODS AND SYSTEMS TO MATCH EXISTING AND
AS APPROVED BY ORIGINAL ROOFING MANUFACTURER.
ROOFELEVATORADMIN. ANTEFREEZER &SECUREDROLLINGRECEPTION RECEIVINGB
PROJECT LOCATION
REF
WKT1
WS
PT-1
EPY-1
PASS
TR
250B-A
INT
SAN
DS
EPY-1
PT-1
CS500
STO
ST
S.S. ANGLE
SHROUD;TERMINATES
AT TOP OF HOOD
EXHAUST RISER
LH
NHD
EPY-1
PT-1
LP
CH1
250B-AIVSH
PT
SOAP
HW/EW
FILE
INT
EPY-1
PT-1
SHOE
SAN
PH
WKT2
COM
DS
NHD
REF250-AFEC SAN PPE
ST
EPY-1
PT-1
WKT4
TR
250A-A
PPE
HW/EW
ST
PT
EPY-1
PT-1
WKT4
DS
A
LEVEL 3
30' - 0"
LEVEL 2
20' - 0"
MASONRY VENEER WALL INTERLOCKING SYSTEM WITH 9 GA.
WIRE REINFORCING AND WIRE TIE CONSTRUCTION. BRICK INFILL
TO MATCH EXISTING ADJACENT. SAW-TOOTH IN NEW BRICK TO
CREATE EVEN TRANSITION BETWEEN NEW AND EXISTING BRICK
6" METAL STUD
M
IN
6" 9'
0"
BATT INSULATION FILL
1/2" PLYWOOD SHEATHING
CONT WEATHER RESISTANT BARRIER.
TIE-IN TO EXISTING WRB SYSTEM.
6" METAL STUD FURRING
EXISTING WALL CONSTRUCTION;
MASONRY VENEER WALL, 1" RIGID
INSULATION, 8" CMU BLOCK, METAL
STUD WALL AND GYPSUM BOARD FINISH
INTERIOR GYP BD FINISH
3'
0" 4'
0"
2'
0"
GWB ON SUSPENDED CEILING GRID SYSTEM
250C-B
TR
PT-1
DS
PPE
SHOE
EPY-1
PT-1
EPY-1
PT-1
PT
SOAP
HW/EW
SAN
TR
INT
EPY-1
PT-1
250C-A
DS
EPY-1
PT-1
WKT3 TR
CS600
S.S. ANGLE
SHROUD;TERMINATES AT TOP
OF HOOD EXHAUST RISER
250A-A
DISP
TR
SANINT
EPY-1
PT-1
DS
TR
EPY-1
PT-1
WKT1
LH
SS500
EPY-1
PT-1
SS500
WKT1
CLEAN AIR PASS THRU
SEE FLOOR PLAN FOR PARTITION TYPE
CONT. SEALANT AT PERIMETER, BOTH SIDES, TYP.
CONT. SEALANT AT PERIMETER, BOTH SIDES, TYP.
STAINLESS STEEL FLUSH MOUNT HINGES
RECEIVING/BREAK DOWNNEG. ANTE
METAL STUD HEADER
T O
P A
S S
T H
R O
U G
H S
U R
F A
C E
3'
2"
PASS
INT
EPY-1
PT-1
WKT2
EXHAUST DUCT RISER
CS500 HOOD
PARTITION AS SCHED.
APPROX. POWER CORD
LOCATION
SEALANT, CONT. EACH
SIDE
ADHESIVE APPLIED S.S. SHEET
METAL ANGLE; ANGLES TO BE ON
ALL (4) SIDES OF EXHAUST RISER
1' - 1"
2"
NOTE: STAINLESS STEEL SHEET METAL ANGLE DEPTH TO BE DETERMINED IN FIELD WHEN
HOODS ARE ON SITE.
A S e rv ic e
D i s a b le d
Ve t e r an Owned S m a l l B u s iness
SDVOSB
CVE
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
M.E.P. & Structural Engineering
A Service Disabled Veteran Owned Small Business
MR PROJECT NO: 0499-0116
Drawing Title
Approved: Project Director
Project Title
Issue Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANT Office of o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t 6 o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231
1 2 3 4 5 6 87 9
97 8654321
B
A
C
D
E
F
NO. DESCRIPTION DATE
PLAN
NORTH
PHARMACY USP 800 RENOVATION 620A4-18-212
15H
U.S. Department of Veterans Affairs
MILLER-REMICK LLC
PROFESSIONAL ENGINEER
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE
WHATSOEVER WITHOUT THE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER.
ACTUAL
NORTH
Phase
BID DOCUMENTS
FULLY SPRINKLERED
Construction and Facilities Management
ENGINEER OF RECORD INTERIOR ELEVATIONS,SECTIONS & DETAILS
A-200 2022-08-24
CASTLE POINT CAMPUS
WAPPINGERS FALLS, NY
JBS JDW
INTERIOR ELEVATIONS
1/4" = 1'-0"A1 NEG. ANTE RM - NORTH
1/4" = 1'-0"A2 NEG. ANTE RM - SOUTH
1/4" = 1'-0"C1 NEG. BUFFER RM - SOUTH
1/4" = 1'-0"B1 POS. ANTE RM - EAST
1/4" = 1'-0"B2 POS. ANTE RM - NORTH
1/4" = 1'-0"B4 POS. ANTE RM - SOUTH
1/4" = 1'-0"B5 POS. ANTE RM - WEST
3/4" = 1'-0"C7 WALL INFILL SECTION AT EXISTING WINDOW
1/4" = 1'-0"A3 NEG. ANTE RM - WEST
1/4" = 1'-0"A5 AIRLOCK - NORTH
1/4" = 1'-0"A6 AIRLOCK - SOUTH
1/4" = 1'-0"C2 NEG. BUFFER RM - EAST
1/4" = 1'-0"C3 NEG. BUFFER RM - NORTH
1/4" = 1'-0"D1 POS. BUFFER RM - EAST
1/4" = 1'-0"E1 POS. BUFFER RM - NORTH
1/4" = 1'-0"D2 POS. BUFFER RM - SOUTH
1/4" = 1'-0"E2 POS. BUFFER RM - WEST
SECTIONS
3/4" = 1'-0"E7 PASS THRU SECTION
1/4" = 1'-0"C5 RECEIVING/ BREAK DOWN-NORTH
QTY
TYPE
MARK DESCRIPTION PRODUCT #
FURNISH
ED BY
INSTALLED
BY REMARK
1 CH1 CHAIR ON CASTERS WITH CUSHIONED BACK N/A VA VA
1 COM COMPUTER, REQUIRES POWER AND DATA N/A VA VA
1 CS500 CLASS II BIOLOGICAL SAFETY CABINET WITH
TOUCHSCREEN MONITOR, DUAL POWER OUTLETS, AND
CLOSED CONTAINMENT SYSTEM FOR HAZARDOUS WASTE.
CS500 VA CON. COORDINATE WITH CORE AND PHARMACY
1 CS600 CLASS II BIOLOGICAL SAFETY CABINET WITH
TOUCHSCREEN MONITOR, DUAL POWER OUTLETS, AND
CLOSED CONTAINMENT SYSTEM FOR HAZARDOUS WASTE.
CS600 VA CON. COORDINATE WITH CORE AND PHARMACY
1 DISP WALL MOUNT MASK, BEARD, HAIR COVER DISPENSER. N/A VA VA
8 DS WALL MOUNTED DOOR SENSOR - HAND WAVED N/A CON. CON.
1 FE SURFACE MOUNTED FIRE EXTINGUISHER N/A CON. CON.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .