This document is a product specification sheet for the EPOCH 650 Digital Ultrasonic Flaw Detector, model P/N EP650-BX-UE-K, a portable nondestructive testing instrument designed for materials inspection and flaw detection applications.

The device features ISO 22232-1 compliance with a digital high dynamic range receiver, Perfect Square tunable square wave pulser, and thirty digital filters to optimize signal-to-noise ratio with automated calibration. Testing capabilities include pulse echo, dual, and through transmission modes with two fully independent measurement gates for amplitude and Time of Flight measurements. The instrument offers a measurement range of 0.132 to 527.10 inches, velocity range of 0.0250 to 0.6000 in./µs, and refracted angle adjustments from 0° to 90° in 0.1° increments, with a 2 kHz pulse repetition frequency for rapid scanning. Standard sizing software includes dynamic DAC/TCG and onboard DGS/AVG capabilities, and a one-touch gain setting automatically positions peak signal to 80% screen height. The display is a large, full VGA sunlight-readable screen (640 x 480 pixels, 4.62 x 3.49 inches) with full-screen A-scan viewing mode, knob configuration, and English keypad controls. Power is provided by a single rechargeable lithium-ion battery delivering 15+ hours of operational life, with 100-120VAC, 50-60 Hz input power capability. Connectivity includes BNC transducer connection, alarm output, and VGA data outputs for external display or recording.

View the file

Other files

File Type Posted
Solicitation SPMYM226Q0148.pdf PDF
Solicitation SPMYM226Q0148.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EPOCH 650 DIGITAL ULTRASONIC FLAW DETECTOR, P/N

EP650-BX-UE-K

1. Standards Compliance & Core Architecture

• ISO 22232-1 Compliance: Formally meets the international standard for digital ultrasonic instrument characterization and verification.

• Receiver: Digital high dynamic range receiver.

• Pulser: Perfect Square™ tunable square wave pulser.

• Signal Processing: Thirty digital filters for enhanced signal-to-noise ratio.

• Calibration: Automated calibration.

2. Testing & Measurement Capabilities

• Test Modes: Pulse echo, dual, or through transmission.

• Measurement Gates: 2 fully independent gates for amplitude and Time of Flight

(TOF) measurements.

• Sizing Software: Standard dynamic DAC/TCG and onboard DGS/AVG.

• Pulse Repetition Frequency (PRF): 2 kHz for rapid scanning.

• Refracted Angle: 0° to 90° in 0.1° increments.

• Gain Setting: one-touch feature that sets peak signal automatically to 80% screen height

3. Range & Calibration Parameters

• Measurement Range: 0.132 in. to 527.10 in. (at 0.2320 in./μs).

• Velocity Range: 0.0250 in./µs to 0.6000 in./µs.

• Zero Offset: 0 µs to 750 µs.

• Display Delay: -2.320 in. to 526.97 in. (at longitudinal velocity in steel).

4. Display & User Interface

• Screen Type: Large, full VGA sunlight-readable display (640 x 480 pixels).

• Display Dimensions: 4.62 in x 3.49 in (5.76 in diagonal).

• Viewing Modes: Full-screen A-scan mode.

• Hardware Control: knob configuration and English Keypad.

5. Power & Connectivity

• Battery: Single rechargeable lithium-ion battery providing 15+ hours of life.

• Input Power: 100 - 120VAC, 50 - 60 Hz.

• Transducer Connection: BNC connection.

• Data Outputs: Alarm and VGA outputs.