60-A2-32-Mall Roof Plan.pdf
PDF 3 MB Posted
- Attached to
- Gutter Repairs on B307 Federal contract opportunity
- Solicitation number
- W50S8V-25-B-A011
- Issued by
- Department of the Army National Guard
About this file
The document is a detailed roof plan (A2.32) for the West Virginia Air National Guard's C-5 Maintenance Hangar and Shops located in Martinsburg, WV. The roof plan covers Areas E, F, G, and H, showing a complex layout with multiple roof sections featuring varying slopes (ranging from 1:12 to 3:12), metal standing seam roofing, and numerous roof penetrations including gas vents, goosenecks, downspouts, and an NDI (Non-Destructive Inspection) warning light. The plan includes specific technical details such as heat trace requirements at valley gutters, internal and external gutter specifications, snow guard rail systems, and lightning rod placements. The drawing is part of a comprehensive set of project record drawings prepared by CH2MHILL and DMJM design, with involvement from multiple consultants including Paragon Structural Design and LPDA Inc., dated September 10, 2007 as a project record drawing.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| B307 Gutter Repair_Bid Opening Attendance Sheet.pdf | ||
| Abstract of Offers - B-A011.pdf | ||
| Solicitation Amendment W50S8V25BA0110001 SF 30.pdf | ||
| Solicitation Amendment - W50S8V25BA0110001.pdf | ||
| Construction Information for Bidders.pdf | ||
| Site Visit PP - Renovate B307 Gutter Repair.pptx | PPTX presentation | |
| B307 GUTTER REPAIR - SITE VISIT_Attendees List.pdf | ||
| Construction Wage Determination - WV20250034.pdf | ||
| 20241212 - NEW VISTOR AND CONTRACTOR BACKGROUND FORM APRIL 2024.docx | DOCX document | |
| SOW 250290 - Repair Internal Gutters (2ea).pdf | ||
| Solicitation - W50S8V25BA011.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D
C
B
A
@ 577'-6" @ [176022]
24'-6"
[7468]
MATCHLINE, SEE
SHEET A2.31
25'-Q"
[7620]
22'-6"
[6858]
'° I N
2'- "
~ ,I
I ----7' 16;-------.......__
' 0 I
"o .,.., I I
I r-- -
MALL
ROOF PLAN AREAS E,F,G,H
A2.32 REF. SCALE: 1/16" = 1'-0"
• 0 I
I, L
27'-6" 25'-Q" 5'-10 1/2" 17'-7"
[8382] [7620] [1784 [5353]
L~
.. N 1.1.J -:-:
o,_ 0 Oc,, __, .
C/l N
' See RFI 57 on top right of page
~ l
SLOPE:
3:12
N o,_ g -.,.., "o (/) I
"' <1/
• 0
I
MATCH LINE,
SEE SHEET
A2.31 lYP.
'° I
4'-0" 30'-o"
21 J-----.l.
8 ,-----" lYP. t
I jf SLOPE:
• 0 I
I I
I I
I I
X I I
I I
I I
I I
I I
I I
I I
I I
Ji( , I I
I I
I I
I I
I I
I I
I I
2'- II
1[ I I
27'-10"
[848'\l
SLOPE:
3:12
'° I
2'- I
'.+--,\-\- I+-t~I SLOPE: &l I;,.; I 3: 2
3'-0"
SLOPE:
3:12
'° I
19'-10"
[6045]
SLOPE:
1 :12
SLOPE:
1 :12
@) Q] 19'-10"
[6045]
- \ - A '---\V
SLOPE:
1 :12
SLOPE:
1 :12
Option not accepted
3'-0 6
' 00 I
N
2'-6" - +Lii"iJ-..-.:3'-Q"
SLOPE: SLOPE:
3:1 1:12
8 ,>----. ____
SLOPE:
1 :12
27'-10" 30•-o· 30•-o·
[8484] [9144] [9144]
---- X~~~~~~, SLOPE:
3:12
SLOPE:
3:12 lYP.
L 5-0
4'-8"
IK-----------< 1
lYP.
2'-6"
I lYP.
I
I
I
I
I
I
I . I
I
I
I -----<- 7
I
, 3'-Q" 25'-Q"
I
I
I
N
½
SLOPE:
3:12
! I lv --------'- 1
# bl ,l>=--<>==-<>===>--=<>=-=<>==-"<--0 = == ~ ~ 22 ~~ .,.., I ---....1y 8
SLOPE:
3:12
------<: 8
• 0 I
,.._ 0 lo
• N '° ~ -- 1 . ~I "' "' I :Jl
• N 00 ~
- a, ,-
- -1'0 z=...
'o ,:::,1'
- a, I a,
• N "' ~
,-"o °'I '° "' ,.._ N~ i i N I
• i i .... - , I ~ f l ·' "' N ~ f l 0 I
"' N ~ f l 0 I
"' N ~
I ~ .,.., N - 0 "' .,.., i i 0 I
"' N ~
' ~I 0 I
"' N ~
"o i i I
"' N ~
' ~I 0 I
"' N ~
"o i i I
"' N ~
°f~I .,.., ,.._
~~l ~j .:::. \ I L _____ _
9 L ______ _ lYP. l
3 0 4
p. 1
CD
Q)
GENERAL NOTES:
1. ALL ROOFS ARE STANDING SEAM METAL.
2. SEE ELEVATIONS FOR RIDGE AND SOFFIT HEIGHTS .
3. SEE SHEETS AB.20 - AB.24 FOR ROOF DETAILS
4. ROOF INSTALLATION FOR THE SHOPS AND SECOND FLOOR SHALL BE R-20.
RFI 57
Information Requested Drawing A2.32 note 13 references a NDI Warning Light. There are no indications for:
-haw this is to be powered and controlled -how to mount -specification of fixture
Please provide feeder circuit and control pathway (or location), desired mounting scheme, and fixture specification.
Response Refer to: E5.05 Detail 4. Note that ,n Note 5, " ... --NS" is misspelled d h Id b " N5" an s ou e ... - .
E2. 15 Key Note 18 A2.32 Key Note 1 3 A8.23 D5, Roof Penetration The purpose of this beacon is to warn any personnel working on the roof of a potentially dangerous problem. Mount the beacon a minimum of 12 inches above the roof surface.
KEY NOTES:
0 METAL CANOPY, OPTION 7 v--,,~Option not accepted.
HEAT TRACE AT VALLEY GUTTER, SEE A5/A8.22.
0 HEAT TRACE BELOW ROOF AT VALLEY GUillR. SEE A5/A8.22.
0 18" DIA. GAS VENT, SEE M3.D1
0 FLTURE ROOF, CORROSION CONTROL HANGAR
0 ROOF RIDGE, SEE B2/A8.23
0 INTERNAL GUTTER 9'W x 6"H MIN., SLOPE 1/8 : 12 TO DOWNSPOUT. SEE
SHEET AB.20 FOR HANGAR CONDITION AND A8.22 FOR LOW BAY CONDITION.
0 EXTERNAL GUTTER 6"W x 6"H MIN., SLOPE 1/8 : 12 TO DRAIN
0 DOWNSPOUT, lYP. DOWNSPOUTS TO BE PLACED NO MORE THAN 40' -0" O.C. MAX.
APART AND AS INDICATED.
0 LINE OF SOFFIT BELOW, SEE C5/A8.20
0 EDGE OF WALL BELOW
0 FLUES, SEE PLUMBING DWGS AND D5/A8.23.
,...--....._,.Sheet 4/E5.05, E2.15 Keynote
NA, GFci 8, D5/A8.23.
M SHED ROOF BELOW CANOPY, SEE ELEVATIONS AND
V 2/A5.15 0 4" lYPE B VENT PIPE AND CAP.
0 (2) 1 O' DIA. GOOSENECKS
0 14" DIA. GOOSENECK
0 12" DIA. GOOSENECK
<3> 8" DIA. GOOSENECK
0 6" DIA. GOOSENECK
0 3" VENT THROUGH ROOF
0 4" VENT THROUGH ROOF
LEGEND:
X LIGHTNING ROD, lYP. SEE SHEET E2.30.
SNOW GUARD RAIL SYSTEM, SEE
SPEC. SECTION 07610
PLAN
NORTH
0 8 16 32 48 -==i~_i----1 ____ ~ 1 /16" = 1' c::::::..._ I
CLIENT
VIRGINIA AIR WEST
NATIONAL GUARD
C- 5 MAINTENANCE HANGAR AND SHOPS
167th AIRLIFT WING - MARTINSBURG, 'IN
PROJECT NUMBER: PJVY009073
DESIGNER
CH2MHILL
13921 Park Center Road, Suite 600. Herndon, VA 20171 T: 703-471-1441 F: 703-471-1508 www.ch2mhi1l.com design
405 HOWARD ST. 4TH FLOOR, SAN FRANCISCO CALIFORNIA 94105
T: 415-986-1373 F: 415-986-4886 www.dmjm.com
CONSULTANTS
PARAGON
STRUCTURAL DESIGN, INC.
411 North Central Avenue, Suite 800 Phoenix, Arizona 85004-2134
PHONE: 602-2S8-0011 FAX: 602-258-0033
www.paragonstr.com
LPDA Inc.
LAND PLANNING & DESIGN ASSOCIATES, INC. ~ RIA®
310 EAST MAIN ST. SUITE 200, CHARLOTTESVILLE, VA 22902
T: 434-296-2108 F: -43-4-296-2109 www.lpda.net
IOOWEST RlTON STREIT, !UTE i,J, CHrJ..GO, IL 606il T: 312-879-7200 F: ]12-Bn-7110 -.w,w.~up.com
REGISTRATION
PROJECT RECORD
DRAWINGS
7500 Old Georgetown Road. Bethesda, MD 20814-6133 T: 301-272-8100 F: 301-272-1928 www.clarkconstruclion.com
ISSUE
09/10/07 PROJECT RECORD DRAWING
02/21/05 FINAL
MARK DATE DESCRIPTION
PROJECT NO: 032151053.0070.0001.005
DRAWN BY:
CHECKED BY:
KEY PLAN
AREAS
C
SHEET TITLE
E,F,G,H
(I) (I)
(I) (D
MALL
ROOF PLAN
A2.32
JY
OP
- e
SHEET 060 OF 481
@ 2004 Dt.tJt.tH+N, Inc. Rev. 2004-1 _J
1388435220N Highlight Apply tyvex coating or approved equivalent to two each internal gutters to ensure water tight seal
File details come from the government source that posted it. Updated .