6-Repair Report 1 - Wade Road.pdf
PDF 238 KB Posted
- Attached to
- ITB - Hydraulic Lift Replacement, Maintenance and Related Items for Harris County Precinct 2
- Solicitation number
- 25/0188
- Issued by
- Harris County, Texas
About this file
This document is a Certified Lift Inspectors report for Harris County Wade Rd, conducted by an Automotive Lift Institute (ALI) certified inspector on 9-25-24. The inspection report details the assessment of three American-brand automotive lifts located at Rd. 8103 Wade Rd. in Baytown, TX, with the inspector identifying significant safety and functional deficiencies in all three lifts.
The inspection reveals critical failures across two A30 model lifts and one A-12K model lift, with specific issues including: lack of rear automatic wheel stops, missing safety placards, non-lubricated chains, no wheel chocks available, and power supply problems. The report emphatically states that the two A30 lifts will not pass an ALI inspection without automatic engaging wheel stops. Additionally, the report notes that one 4-post lift and one 2-post lift located outside are in poor condition, having been disassembled and degraded from exposure to weather, with the lifts described as older, outdated, and missing parts.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Certified Lift
Inspectors
Company Name: Harris County Wade Rd Inspection Date: 9-25-24
Address: Rd. 8103 Wade Rd.
City, State, Zip: Baytown, TX. ALI Inspector: Jeff Buchanan #2067
Attention:
Reference:
# BRAND MODEL S/N P/F COMMENTS and OBSERVATION NOTES
1 American A30 042 202 Q FAIL Runways do not have rear automatic wheel stops. Lift is older and was not designed with automatic engaging wheel stops. There are no wheel chocks available. Missing safety placard and chains need to be lubricated.
2 American A30 042 402 FAIL Runways do not have rear automatic wheel stops. Lift is older and was not designed with automatic engaging wheel stops. There are no wheel chocks available. Missing safety placard and chains need to be lubricated.
THESE 2 LIFTS WILL NOT PASS AN ALI INSPECTION WITHOUT AUTOMATIC
ENGAGING WHEEL STOPS
3 American A-12K 090297-1 FAIL There is no power going to this lift
One 4 post lift/ one 2 post lift outside taken apart and are in bad shape due to sitting in weather and lifts are older/ outdated Missing parts.
Docusign Envelope ID: 33624330-2D7A-44AD-9DF4-CA70BAF4C6C3
| 2024-10-02T13:28:17-0700 | |
| Digitally verifiable PDF exported from www.docusign.com |