6 Inch Trash Pump Revised Specifications 10282024~1.docx

DOCX document 14 KB Posted

Attached to
DNR - 6" Trash Flow Pump Re-Bid - Rend Lake SFWA
Solicitation number
25-422DNR-RESCO-B-45453
Issued by
Illinois

About this file

This document contains the revised specifications for a 6-inch heavy duty trash flow pump. The pump is required to be diesel-powered with a DOT-approved trailer, an 80-gallon on-board fuel tank, and 200 feet of suction hose and 100 feet of discharge hose with 6-inch ANSI flanged connections. The pump has a maximum speed of 2,200 RPM, a maximum flow of 3,000 GPM, a maximum head of 202 feet, a maximum static priming lift of 28 feet, and a temperature limit of 160°F. The pump can handle solids up to 3 inches in size.

The document does not provide any information about a state or local contract opportunity. It only outlines the technical specifications for the 6-inch trash flow pump.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Heavy Duty 6" Trash Flow Pump Revised Specifications

· Diesel Engine

· DOT Approved Trailer w/ LED lights or on wheels and can be hooked to any truck or tractor.

· 80 Gallon On-Board Fuel tank

· 200 ft of Camlock Suction Hose & 100 ft of Discharge Hose

· Connections 6” (150 mm)

· ANSI Flanges Max Pump Speed 2,200 rpm

· Max Flow 3,000 gpm (681 m3 /h)

· Max Head 202’ (61.6 m)

· Max Static Priming Lift 28’ (8.5 m)

· Temperature Limit 160° F (70° C)

· Solids Handling Capability 3” (76.2 mm)

File details come from the government source that posted it. Updated .